MYM. Ali Youssoufi

M. Ali Youssoufi

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


M. Ali Youssoufi has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • A Mribah

    Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco

    1 shared publication
  • A. Bardane

    Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco

    1 shared publication
  • A. Dadouch

    Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco

    1 shared publication
  • A. El Hajami

    Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco

    1 shared publication
  • A. Maghnouj

    Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco

    1 shared publication
  • ElMahjoub Chakir

    Ibn Tofail University

    1 shared publication

Latest Publications

  • Open Access

    Establishment of local diagnostic reference levels for breast cancer CT protocols in radiotherapy in a single Moroccan center

    by O. Nhila, M. Talbi, M.A. Youssoufi, M. El Mansouri, Z. Tahiri, E.M. Chakir, M. Azougagh

    The objective of this study was to establish local diagnostic reference levels (LDRLs) for breast cancer computed tomography imaging in radiotherapy (CT-RT) at a single hospital in Morocco. Data were collected from 106 adult breast cancer patients aged between 33 and 78 yr during five months. Data were obtained using a Hitachi Supria 16-slice CT simulator at a regional oncology center in Morocco. CT-RT images are intended for 3D conformal radiotherapy treatment planning. Dose length product (DLP) and volumetric computed tomography dose index (CTDIvol) were evaluated by determining the 75th percentile as diagnostic reference levels for CT-RT breast cancer. LDRLs for CT-RT breast cancer have been determined in terms of DLP and CTDIvol, and they were 330.4 mGy.cm and 6.8 mGy, respectively. The DRLs were compared with other Europeans study. DRLs for this study were lower than those for the United Kingdom (UK), Croatia and Slovenia. The results of this study can be a reference for the establishment of local and national DRLs in Morocco and the optimization of CT-RT breast cancer procedures.


  • Evaluation of PTV margins in IMRT for head and neck cancer and prostate cancer

    by M. A. Youssoufi, M. Bougtib, S. Douama, M. Ait Erraisse, F. Z. Abboud, K. Hassouni, F. Bentayeb

    Purpose: The aim of this study was to evaluate planning target volume (PTV) margins for two different locations using an electronic portal imaging device (EPID) to ensure that the correct radiation dose is delivered to the tumour when using intensity-modulated radiation therapy (IMRT). Materials and methods: Setup data were collected from 40 patients treated with IMRT for head and neck cancer (HN) (20 patients) and prostate cancer (20 patients). Setup errors from 720 registration images were analysed to evaluate systematic and random errors. Thereafter, optimal PTV margins were calculated based on International Commission on Radiation Units and Measurements 62 (ICRU), Stroom and Parker formulas compared with the Van Herk’s recipe. Results: To calculate the margins around the PTV, several different formulas have been used. Setup margins ranged between 2–4·3, 2·2–4·6 and 2·1–4·7 mm in X, Y and Z directions, respectively, for HN cases. Similarly, for the prostate site, setup margins ranged between 3·7–8·3, 3·2–6·8 and 3·3–8·2 mm in X, Y and Z directions. Conclusion: To ensure better coverage of target volume, we adopted a PTV margin of 5 mm for HN PTVs and 10 mm for prostate PTVs in our department.


  • Open Access

    Evaluation of the performance of an ionization chamber cylindrical (PTW) by the ELEKTA linear accelerator: Case of pulsed radiation

    by A. El Hajami, A. Dadouch, J. Tajmouati, A. Maghnouj, M. Ali Youssoufi, M. El Baraka, A. Bardane, H. El Bekouri, F. Moussahim, A Mribah

    The performance evaluation of cavity cylindrical ionization chamber dosimeters is the basis for the evolution of radiotherapy treatment processes. Studies focused on the statistical and physical performances of the ionization chamber dosimeter used in the radiotherapy department at the hospital oncology CHU-Fez-Morocco. This allowed having a qualitative and quantitative critical view, which is based on previous studies and works. The diagnostic of the dispersion results was calculated between measurements that were taken by the same dosimeter under different test conditions. These tests were then rechecked against two different operators. The general purpose of our study is to optimize measurement and treatment processes, with the desired level of quality according to international standards and protocols. The evaluation of this dosimeter is made by a source of pulsed radiation. This evaluation is carried out using an ELEKTA linear accelerator, using photon beams (6, 10 and 18 Mev). Experimental Results confirmed that the response of the cylindrical ionization chamber depends on several parameters, which influence the performance of the device/machine. The study reveals a total dosimeter uncertainty of the order 3.25 %, which is in the international standards. Even, this can cause an effect on the performance of the ionization chamber detector.

  • A planning study to optimise a simultaneously integrated boost treatment of larynx cancer with seven intensity-modulated radiation therapy (IMRT) beams

    by M. Erraoudi, M. A. Youssoufi, F. Bentayeb, M. R. Malisan

    Background: Intensity-modulated radiation therapy (IMRT) is one of the most reported techniques for head and neck cancer treatment, as it allows a good coverage of the planning target volume (PTV) while sparing the surrounding organs at risk (OAR) better than conventional conformal radiotherapy. The objective of this work is to optimise an IMRT technique for the simultaneously integrated boost (SIB) treatment of larynx cancer delivering a total dose of 69-96 Gy to the boost volume and 54.45 Gy to the elective volume in 33 fractions. Methods: Three IMRT techniques, each using seven equally spaced beams, were planned for a sample of 10 patients. The first two techniques (IMRT-0 and IMRT-26) differ only for the starting angle of the seven beams, whereas the third (IMRT-CT) combines both these techniques by delivering IMRT-0 in the first half of treatment, and IMRT-26 in the second half, thus taking advantage of using 14 beams in total while using seven at a time only. The planning results were compared according to the dose coverage, homogeneity and conformity of the two PTVs, as well as to the dose to OARs, that is, spinal cord, parotids, mandible, brainstem and healthy tissue (defined as the body volume minus the sum of PTVs). Results: Basically the PTV coverage resulted acceptable and comparable with all the three techniques. Concerning OARs, statistically better results are obtained in IMRT-CT when compared with IMRT-26 and IMRT-0. Conclusion: The IMRT-CT technique, combining two different seven-beam setups, delivered in two treatment phases, improves dose distribution without increasing delivery time.