Jalal Faraj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jalal Faraj has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Mahmoud Khaled
Energy and Thermo-Fluid Group, Lebanese International University LIU, Bekaa P.O. Box 146404, Lebanon
3 shared publications - Haitham Saad Ramadan
Electrical Power and Machines Department Zagazig University Zagazig Egypt
2 shared publications - Khaled Chahine
College of Engineering and Technology, American University of the Middle East, Egaila 54200, Kuwait
2 shared publications - Mostafa Mortada
Energy and Thermo-Fluid Group, Lebanese International University LIU, Bekaa Campus, Bekaa 1801, Lebanon
2 shared publications - Thierry Lemenand
LARIS EA 7315, Polytech Angers, University of Angers, 49000 Angers, France
2 shared publications - Elias Harika
Energy and Thermofluid Group, Lebanese International University (LIU), Bekaa 1801, Lebanon
1 shared publication
Latest Publications
- Open Access
Effect of Airflow Non-Uniformities on the Thermal Performance of Water–Air Heat Exchangers—Experimental Study and Analysis
The thermal performance of fin-and-tube heat exchangers (HX) is a crucial aspect in a multitude of applications and fields; several design and operational parameters influence this performance. This study focuses on the issue of flow maldistribution and its effect on the HX thermal performance. For this purpose, an experimental setup is designed and implemented to emulate the conditions under which an automotive heat exchanger operates in regard to the non-uniform upstream airflow velocity distribution over the HX surface. The setup allows obtaining various configurations of airflow velocity non-uniformity of some desired mean velocity and standard deviation. The experimental results reveal that a higher degree of non-uniformity (higher standard deviation of the velocity distribution) causes an increased deterioration of the HX thermal performance. For example, at a water flowrate of 200 L/h and a mean airflow velocity of 2 m/s, increasing the standard deviation from 0 to 2 m/s (i.e., moving from the lowest to highest degrees of non-uniformity) causes a total deterioration of 27% in the performance (3.78 to 2.75 kW, respectively), which can also be observed in the increased level of outlet water temperature (53.8 to 58.2 °C, respectively). The obtained results confirm the numerical results reported in the literature.
Open AccessEffect of Airflow Non-Uniformities on the Thermal Performance of Water–Air Heat Exchangers—Experimental Study and Analysis
The thermal performance of fin-and-tube heat exchangers (HX) is a crucial aspect in a multitude of applications and fields; several design and operational parameters influence this performance. This study focuses on the issue of flow maldistribution and its effect on the HX thermal performance. For this purpose, an experimental setup is designed and implemented to emulate the conditions under which an automotive heat exchanger operates in regard to the non-uniform upstream airflow velocity distribution over the HX surface. The setup allows obtaining various configurations of airflow velocity non-uniformity of some desired mean velocity and standard deviation. The experimental results reveal that a higher degree of non-uniformity (higher standard deviation of the velocity distribution) causes an increased deterioration of the HX thermal performance. For example, at a water flowrate of 200 L/h and a mean airflow velocity of 2 m/s, increasing the standard deviation from 0 to 2 m/s (i.e., moving from the lowest to highest degrees of non-uniformity) causes a total deterioration of 27% in the performance (3.78 to 2.75 kW, respectively), which can also be observed in the increased level of outlet water temperature (53.8 to 58.2 °C, respectively). The obtained results confirm the numerical results reported in the literature.
- Open Access
Eco-Efficient Vehicle Cooling Modules with Integrated Diffusers—Thermal, Energy, and Environmental Analyses
The automotive domain is a very good candidate for energy management, particularly due to the huge amounts of energy lost by heat through exhaust and water-cooling systems. This makes the optimization of vehicle cooling modules directly related to energy consumption and carbon dioxide emission. In this context, contemporary designs that employ diffusers between the forward-facing of an automobile and its heat exchanger subjected to airflow are presented in this work. The ultimate aim is to reduce the fuel consumption and carbon dioxide emissions of vehicles. Based on the aforementioned design, the intensity of the air velocity would be decreased but distributed over a larger exchanger surface. Consequently, the velocity non-uniformity of the airflow upstream would decrease and therefore, the thermal performance would increase. The above-mentioned conclusion is a result of parametric numerical analysis and its associated numerical results that disclosed the enhancement of water-air heat exchanger thermal performance. To perform a parametric numerical analysis of the heat exchanger thermal performance for the new suggested configurations, a computational code was developed and validated to estimate the thermal performance for a known set of parameters. It was shown that for an automobile, with engine power ranging from 100–200 kW that is utilized for three hours a day and equipped with a diffuser, reduction of up to 2.91 kg (3.89 L) of gasoline consumption and 9.51 kg of CO2 emission can be achieved per day. The originality of the present work resides in the use of diffusers in cooling modules of vehicles, the thermal modeling of heat exchanger’s thermal performance along with its associated code, and the parametric analysis performed to prove the potential enhancement related to the use of diffusers in the cooling modules.
Open AccessEco-Efficient Vehicle Cooling Modules with Integrated Diffusers—Thermal, Energy, and Environmental Analyses
The automotive domain is a very good candidate for energy management, particularly due to the huge amounts of energy lost by heat through exhaust and water-cooling systems. This makes the optimization of vehicle cooling modules directly related to energy consumption and carbon dioxide emission. In this context, contemporary designs that employ diffusers between the forward-facing of an automobile and its heat exchanger subjected to airflow are presented in this work. The ultimate aim is to reduce the fuel consumption and carbon dioxide emissions of vehicles. Based on the aforementioned design, the intensity of the air velocity would be decreased but distributed over a larger exchanger surface. Consequently, the velocity non-uniformity of the airflow upstream would decrease and therefore, the thermal performance would increase. The above-mentioned conclusion is a result of parametric numerical analysis and its associated numerical results that disclosed the enhancement of water-air heat exchanger thermal performance. To perform a parametric numerical analysis of the heat exchanger thermal performance for the new suggested configurations, a computational code was developed and validated to estimate the thermal performance for a known set of parameters. It was shown that for an automobile, with engine power ranging from 100–200 kW that is utilized for three hours a day and equipped with a diffuser, reduction of up to 2.91 kg (3.89 L) of gasoline consumption and 9.51 kg of CO2 emission can be achieved per day. The originality of the present work resides in the use of diffusers in cooling modules of vehicles, the thermal modeling of heat exchanger’s thermal performance along with its associated code, and the parametric analysis performed to prove the potential enhancement related to the use of diffusers in the cooling modules.
- Open Access
On the Optimization of Electrical Water Heaters: Modelling Simulations and Experimentation
In the context of a world energy crisis, the only solution to control the situation is in the management of energy. One of the most important management keys is the optimization of electrical components. This article presents a complete numerical and experimental study aiming for the optimization of electrical water heaters for household use. The optimization conceives the minimization of energy consumption simultaneously with the minimization of time to heat water. Firstly, a thermal model well adapted for the case of heaters is constructed and validated experimentally and then a parametric study is conducted covering all the input power, the volume and the external area of the heater. Results are promising, showing significant energy savings are possible with an optimum setting of these parameters, thus presenting a firm tool for the optimization of heaters.
Open AccessOn the Optimization of Electrical Water Heaters: Modelling Simulations and Experimentation
In the context of a world energy crisis, the only solution to control the situation is in the management of energy. One of the most important management keys is the optimization of electrical components. This article presents a complete numerical and experimental study aiming for the optimization of electrical water heaters for household use. The optimization conceives the minimization of energy consumption simultaneously with the minimization of time to heat water. Firstly, a thermal model well adapted for the case of heaters is constructed and validated experimentally and then a parametric study is conducted covering all the input power, the volume and the external area of the heater. Results are promising, showing significant energy savings are possible with an optimum setting of these parameters, thus presenting a firm tool for the optimization of heaters.