Srisailam Sreedhar
Srisailam Sreedhar has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Venkatesh Srinivasan
School of Electrical Engg., Vellore institute of Technology,Vellore,India
3 shared publications- Anjana Jain
Department of Electrical and Electronics Engineering Amrita School of Engineering, Amrita Vishwa Vidyapeetham Bengaluru India
1 shared publication Arulmozhivarman P
Vellore Institute of Technology,Dept. of Instrumentation,Vellore,India
1 shared publicationG. Srilekha
B.Tech, Deptarment of EEE, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Bengaluru, India
1 shared publicationJ.R.S.S. Kumara
University of Peradeniya,Dept. of Electrical & Electronics Engg.,Sri Lanka
1 shared publication- Kunal Kakria
School of Civil Engineering, Vellore Institute of Technology, Vellore 632014, India
1 shared publication
Latest Publications
- Open Access
A Comprehensive Framework for Direct Lightning-Structure-Human Interaction Modelling in Heritage Monuments and Safety Assessment
Lightning is a perilous and unavoidable event of nature that presents major deleterious consequences on humans, tall structures, electrical power systems, forests, etc. Though several research studies have been carried out to analyse the sufficiency of a Lightning Protection System (LPS), very few research findings have been reported to assess the extent of risk due to lightning-human interaction in the vicinity of tall structures. This research aims at carrying out detailed modelling and simulation studies of LPS for heritage structure. Several current waveshapes as stipulated in IEC 62305 are modelled appropriately and presented to the electrical equivalent circuit representation of a heritage monument in South India (Brihadisvara Temple) to ascertain the impact of lightning parameters on heritage monuments. In addition, to assess the effectiveness of the earthing system, detailed earthing models during lightning is developed to assess the role played by aspects such as soil resistivity (single and double), earth electrode dimensions, nature of elements in the equivalent circuit, etc. Further, the role of lightning strikes on human due to step and touch potential is ascertained by formulating a lumped electrical equivalent model of human to assess its role and impact on dry and wet skin.
Open AccessA Comprehensive Framework for Direct Lightning-Structure-Human Interaction Modelling in Heritage Monuments and Safety Assessment
Lightning is a perilous and unavoidable event of nature that presents major deleterious consequences on humans, tall structures, electrical power systems, forests, etc. Though several research studies have been carried out to analyse the sufficiency of a Lightning Protection System (LPS), very few research findings have been reported to assess the extent of risk due to lightning-human interaction in the vicinity of tall structures. This research aims at carrying out detailed modelling and simulation studies of LPS for heritage structure. Several current waveshapes as stipulated in IEC 62305 are modelled appropriately and presented to the electrical equivalent circuit representation of a heritage monument in South India (Brihadisvara Temple) to ascertain the impact of lightning parameters on heritage monuments. In addition, to assess the effectiveness of the earthing system, detailed earthing models during lightning is developed to assess the role played by aspects such as soil resistivity (single and double), earth electrode dimensions, nature of elements in the equivalent circuit, etc. Further, the role of lightning strikes on human due to step and touch potential is ascertained by formulating a lumped electrical equivalent model of human to assess its role and impact on dry and wet skin.
- 27 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Reliability Assessment of Lightning Protection of Renaissance Architecture Based Heritage Church in India Using Electrogeometric Methods
With growing concerns due to climate change, lightning has become a perceptible natural disaster that has triggered large-scale damages to tall structures, including heritage monuments. Several researchers have implemented and utilized various methods of Lightning Protection Systems (LPS) to safeguard the structures from direct lightning strokes. However, several occurrences of damages caused due to lightning strokes on heritage monuments and structures of significance continue to be reported worldwide. The main objectives of this research are to analyze the adequacy and reliability of the existing LPS installed in a famous ‘renaissance architecture’ heritage church i.e., Sé Cathedral, Goa and carry out detailed lightning protection studies for gable roofs using variants of electro-geometric methods. Further, recommendations are summarized wherein locations of critical points of strikes to the structure from direct lightning strikes are identified to avoid consequent damages.
- 27 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Reliability Assessment of Lightning Protection of Renaissance Architecture Based Heritage Church in India Using Electrogeometric Methods
With growing concerns due to climate change, lightning has become a perceptible natural disaster that has triggered large-scale damages to tall structures, including heritage monuments. Several researchers have implemented and utilized various methods of Lightning Protection Systems (LPS) to safeguard the structures from direct lightning strokes. However, several occurrences of damages caused due to lightning strokes on heritage monuments and structures of significance continue to be reported worldwide. The main objectives of this research are to analyze the adequacy and reliability of the existing LPS installed in a famous ‘renaissance architecture’ heritage church i.e., Sé Cathedral, Goa and carry out detailed lightning protection studies for gable roofs using variants of electro-geometric methods. Further, recommendations are summarized wherein locations of critical points of strikes to the structure from direct lightning strikes are identified to avoid consequent damages.
- 30 January 2020
- Published by Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication (BEIESP) in International Journal of Innovative Technology and Exploring Engineering
- Vol. 9 (3) , 988-994
Lightning Protection of Ancient Chola Monument in South India Based on Three-Dimensional Geometric and Electro-Geometric Techniques
Lightning is one of the most commonly occurring natural phenomena which causes irrecoverable damage toedifices which include monuments that uniquely showcase global heritage. Most monuments are usually built tall since these signify symbols of victory, whereby invariably becoming vulnerable to lightning. Though several researchers have implemented various Lightning Protection Systems (LPS) to a considerable level of success, substantial statistical variations in prospective stroke currents during lightning due to factors such as climate change,complexities in geographical topography etc., present considerable challenges in obtaining a common framework for protection of structures. Hence, this research focuses on carrying out analysis based on exhaustive case-studies for an ancient United Nations Educational, Scientific and Cultural Organization (UNESCO) monument in South India. The first objective of this research is in carrying out detailed comparison of shielding effectiveness based on 3D geometric and electro-geometric LPS strategies such as Protection Angle Method (PAM) and Rolling Sphere Method (RSM). The second aims at assessment of risk in accordance with IEC 62305 for estimation of level of risk and the role of varying lightning protection levels utilizing striking distance models to obtain the appropriate choice of the location of air terminal. The third focuses on conducting cross-validation studies to assess the adequacy of the proposed location of LPS using SESShield-3D by depicting the critical zones that necessitate additional protection. In addition, shielding failure analysis of the proposed LPS is also carried out. Inferences on unshielded zones for the three-dimensional (3D) layout models of the monuments have been summarized with appropriate recommendations.
- 30 January 2020
- Published by Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication (BEIESP) in International Journal of Innovative Technology and Exploring Engineering
- Vol. 9 (3) , 988-994
Lightning Protection of Ancient Chola Monument in South India Based on Three-Dimensional Geometric and Electro-Geometric Techniques
Lightning is one of the most commonly occurring natural phenomena which causes irrecoverable damage toedifices which include monuments that uniquely showcase global heritage. Most monuments are usually built tall since these signify symbols of victory, whereby invariably becoming vulnerable to lightning. Though several researchers have implemented various Lightning Protection Systems (LPS) to a considerable level of success, substantial statistical variations in prospective stroke currents during lightning due to factors such as climate change,complexities in geographical topography etc., present considerable challenges in obtaining a common framework for protection of structures. Hence, this research focuses on carrying out analysis based on exhaustive case-studies for an ancient United Nations Educational, Scientific and Cultural Organization (UNESCO) monument in South India. The first objective of this research is in carrying out detailed comparison of shielding effectiveness based on 3D geometric and electro-geometric LPS strategies such as Protection Angle Method (PAM) and Rolling Sphere Method (RSM). The second aims at assessment of risk in accordance with IEC 62305 for estimation of level of risk and the role of varying lightning protection levels utilizing striking distance models to obtain the appropriate choice of the location of air terminal. The third focuses on conducting cross-validation studies to assess the adequacy of the proposed location of LPS using SESShield-3D by depicting the critical zones that necessitate additional protection. In addition, shielding failure analysis of the proposed LPS is also carried out. Inferences on unshielded zones for the three-dimensional (3D) layout models of the monuments have been summarized with appropriate recommendations.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 535-540
Three-Dimensional Implementation of Modified Rolling Sphere Method for Lightning Protection of Giant Medieval Chola Monument in South India
With the advent of global warming, research studies have indicated concerns due to its impact on thunderstorm and lightning which could have detrimental impact on structures. Though there has been substantial progress related to protection of structures against lightning, research carried out during the past decades have led the lightning community to develop improved procedures for evaluating lightning exposure to structures. The location of vulnerable points struck by lightning and hence the placement of air terminals is obtained based on Rolling Sphere Method (RSM) whereby the striking distance is obtained as a function of stroke current. However, the model ignores dynamics of propagation of downward and upward leaders, geometry of the structure etc. This aspect becomes vital for smaller rolling sphere radii for tall structures with respect to several striking points. This research proposes carrying out detailed analysis based on utilizing the Modified Rolling Sphere Method (MRSM) which is based on the concept of an upward directed leader and its interaction with the downward leader during lightning strike on a tall structure. This research involves detailed analysis of lightning protection effectiveness based on MRSM for one of the tallest World Heritage Chola temple architectures in south India. Analysis based on varying lightning stroke currents has been carried out to ascertain the vulnerable points due to varying lightning protection levels. Further, a detailed failure analysis is also carried in line with the requirements of international standards to ascertain additional lightning protection requirements that would enable effective LPS for the proposed heritage monument.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 535-540
Three-Dimensional Implementation of Modified Rolling Sphere Method for Lightning Protection of Giant Medieval Chola Monument in South India
With the advent of global warming, research studies have indicated concerns due to its impact on thunderstorm and lightning which could have detrimental impact on structures. Though there has been substantial progress related to protection of structures against lightning, research carried out during the past decades have led the lightning community to develop improved procedures for evaluating lightning exposure to structures. The location of vulnerable points struck by lightning and hence the placement of air terminals is obtained based on Rolling Sphere Method (RSM) whereby the striking distance is obtained as a function of stroke current. However, the model ignores dynamics of propagation of downward and upward leaders, geometry of the structure etc. This aspect becomes vital for smaller rolling sphere radii for tall structures with respect to several striking points. This research proposes carrying out detailed analysis based on utilizing the Modified Rolling Sphere Method (MRSM) which is based on the concept of an upward directed leader and its interaction with the downward leader during lightning strike on a tall structure. This research involves detailed analysis of lightning protection effectiveness based on MRSM for one of the tallest World Heritage Chola temple architectures in south India. Analysis based on varying lightning stroke currents has been carried out to ascertain the vulnerable points due to varying lightning protection levels. Further, a detailed failure analysis is also carried in line with the requirements of international standards to ascertain additional lightning protection requirements that would enable effective LPS for the proposed heritage monument.
- Open Access
- 4 March 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2) , 784-794
Lightning strokes and its effects on historical monuments, heritage properties and important landmarks a detailed perspective of traditional and scientific methods of lightning protection systems
Lightning is one of the inevitable disastrous natural phenomena which present serious threat to tall structures including ancient monuments and electrical systems. Though researchers have carried out a wide gamut of research studies to analyze the extent of damage due to direct lightning strikes on important buildings and structures, the focus of this research is on understanding the effects of lightning on tall structures of historical importance and landmark monuments of significance. In this context, different types of Lightning Protection Systems (LPS) are being used to protect tall structures from lightning flashes. However, several complexities related to the appropriate choice of LPS continue to confront researchers since characteristics of lightning such as stroke current, striking distance, return stroke modelling, geometry of the structure etc. pose considerable challenges. This research study presents a detailed chronological overview of lightning strikes on ancient structures, cause and effects, review on LPS strategies along with its impacts on tall structures, historical monuments and landmarks. In addition, a detailed analysis based on a specific case study of a typical historical monument is carried out to ascertain the critical significance of the stipulated zone of protection essential for historical monuments and various risks involved during implementation.
- 4 March 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (2) , 784-794
Open AccessLightning strokes and its effects on historical monuments, heritage properties and important landmarks a detailed perspective of traditional and scientific methods of lightning protection systems
Lightning is one of the inevitable disastrous natural phenomena which present serious threat to tall structures including ancient monuments and electrical systems. Though researchers have carried out a wide gamut of research studies to analyze the extent of damage due to direct lightning strikes on important buildings and structures, the focus of this research is on understanding the effects of lightning on tall structures of historical importance and landmark monuments of significance. In this context, different types of Lightning Protection Systems (LPS) are being used to protect tall structures from lightning flashes. However, several complexities related to the appropriate choice of LPS continue to confront researchers since characteristics of lightning such as stroke current, striking distance, return stroke modelling, geometry of the structure etc. pose considerable challenges. This research study presents a detailed chronological overview of lightning strikes on ancient structures, cause and effects, review on LPS strategies along with its impacts on tall structures, historical monuments and landmarks. In addition, a detailed analysis based on a specific case study of a typical historical monument is carried out to ascertain the critical significance of the stipulated zone of protection essential for historical monuments and various risks involved during implementation.
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia Technology
- Vol. 21, 619-624
Battery Charging Using Doubly Fed Induction Generator Connected to Variable Speed Wind Turbine
- 1 January 2015
- Published by Elsevier in Procedia Technology
- Vol. 21, 619-624
Open AccessBattery Charging Using Doubly Fed Induction Generator Connected to Variable Speed Wind Turbine