BLBjorn Ludwig

Bjorn Ludwig

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bjorn Ludwig has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of post‐printing curing time on cytotoxicity of direct printed aligners: A pilot study

    by Giorgio Iodice, Bjorn Ludwig, Elena Polishchuk, Raffaella Petruzzelli, Roberto Di Cunto, Soboh Husam, Mauro Farella

    Introduction: The aim of this in vitro study was to examine the potential impact of different curing times of 3D‐printed orthodontic aligners on their cytotoxicity.Method: Some 60 samples of aligner material were directly 3D printed using Tera Harz TC‐85 DAC resin and randomly allocated to three different curing time groups (14, 24 and 50 min). Zendura FLX samples were used as control. The samples were incubated in saliva for 14 days, and then the supernatant was collected. Human gingival fibroblasts (HGF‐1)‐CRL2014 were used to evaluate potential cytotoxicity. Furthermore, HGF‐1 cells were plated on the samples as well as on a glass control sample. After 72 h of growth, their viability was tested.Results: Compared with the glass, only the 50‐min curing time markedly reduced fibroblast cell growth. Additionally, a negative linear trend was observed between curing time and fibroblast growth. In comparison with the aligner control group, all samples, including the aligner control samples, exhibited a significant reduction in the viability of human fibroblasts when exposed to saliva.Conclusions: 3D directly printed aligners showed a cytotoxic effect similar to that of thermoformed conventional aligners in terms of fibroblasts growth. A linear trend was found between curing time and cells growth, indicating that directly printed aligners could exhibit higher cytotoxicity if exposed to a longer curing time. This dependence on curing time underscores the importance of following a strict manufacturing process.


  • Patient-specific pre-operative simulation of the surgically assisted rapid maxillary expansion using finite element method and Latin hypercube sampling: workflow and first clinical results

    by L. Bonitz, A. Volf, S. Hassfeld, A. Pugachev, B. Ludwig, S. Chhatwani, A. Bicsák

    Asymmetric distraction with different expansions of left and right maxillary parts is a serious complication of surgically assisted rapid maxillary expansion. An individual, highly standardized surgical intervention based on three-dimensional finite element analysis (FEA) is a new method to improve the quality of therapy. We describe a fundamental simulation-based workflow for preoperative evaluation of the osteotomies in a pilot study to achieve symmetry. A CT scan of the skull was used for analysis. Many feasible osteotomy configurations were generated and optimized using Latin hypercube sampling method and FEA choosing an individual osteotomy and maxillary movement. We successfully applied this workflow to 14 patients with symmetrical distraction.


  • Open Access

    The Effects of Additional Filtration on Image Quality and Radiation Dose in Cone Beam CT: An In Vivo Preliminary Investigation

    by Jan Houfrar, Bjorn Ludwig, Dirk Bister, Manuel Nienkemper, Ciamak Abkai, Adith Venugopal

    Purpose. The aim of this study was to investigate the effect of reduced radiation doses on the image quality of cone‐beam computed tomography scans and the suitability of such imaging for orthodontics, oral surgery, dental implantology, periodontology, and endodontology. Materials and Methods. Cone‐beam computed tomography scans of a live patient were performed using seven attenuation filters with increased thickness to decrease the effective radiation dose from 22.4 to 1.8 μSv, and the effects of different radiation doses on image quality were further analysed. Quantitative image quality was calculated using dedicated measures, such as signal and contrast‐to‐noise ratio and sharpness. A panel of five certified raters assessed the cone‐beam computed tomography scans qualitatively. Nine anatomical structures relevant to dentistry were identified, and the overall acceptance was assessed. Results. Linear reduction of the effective radiation dose had a nonlinear effect on image quality. A 5‐fold reduction in the effective dose led to acceptable quantitative and qualitative image quality measures, and the identification rate of dental anatomical structures was 80% or greater. The use of less than 40% of the reference dose was unacceptable for all dental specialties. Conclusions. The ideal radiation dose for specific diagnostic requirements remains a patient‐related and specialty‐related decision that must be made on an individual basis. Based on the results of this study, it is possible to reduce exposure in selected patients, and at the same time obtain sufficient quality of images for clinical purposes.


  • Molar protraction on an adult with severe high-angle Class III malocclusion and knife-edge residual ridges

    by Adith Venugopal, Mona Sayegh Ghoussoub, Paolo Manzano, Prateek Mehta, Anand Marya, Nikhilesh R Vaid, Björn Ludwig, S. Jay Bowman

    Outcome: This case reports the successful treatment of a 40-year-old female with a skeletal Class III malocclusion and knife-edge residual ridges by successfully protracting the lower molars orthodontically.Objectives: On a long-standing extraction space, resorption results in a decrease in the vertical height of the bone, but more importantly, remodelling produces a buccolingual narrowing of the alveolar process as well. Moving teeth into this area is considered almost impossible due to the anatomical limitations. This case places special emphasis on factors to be considered while levelling the curve of Spee on a patient with a very steep mandibular plane, by controlling posterior teeth extrusion, and at the same time elaborates on the biomechanics of molar protraction.Conclusion: In all, the apt use of calculated biomechanical strategies helped in achieving an acceptable, functional and esthetic occlusion in a conservative non-surgical line of treatment.