Ying Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ying Jiang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Xiangyang Xing
Shandong University, Jinan, China
6 shared publications - Changwei Qin
School of Information and Electrical Engineering and Shandong Key Laboratory of Smart Buildings and Energy Efficiency, Shandong Jianzhu University, Jinan, China
4 shared publications - Xiaoyan Li
School of Information and Electrical Engineering and Shandong Key Laboratory of Smart Buildings and Energy Efficiency, Shandong Jianzhu University, Jinan, China
4 shared publications - Chenghui Zhang
Shandong University
3 shared publications - Chang Liu
School of Control Science and Engineering, Shandong University, Jinan, China
2 shared publications Boxue Zhang
School of Control Science and Engineering, Shandong University, Jinan, China
1 shared publication
Latest Publications
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1469-1474
Open-Circuit Fault-Tolerant Operation for Three-Level Quasi-Z-Source Active Neutral Point Clamped Inverter
The article proposes a novel topology of three-level quasi-Z-source active neutral point clamped (qZS-ANPC) inverter that connects the dc power supply to an active neutral point clamped (ANPC) three-level inverter through an intermediate network. Besides the buck-boost function, this topology also provides the potential for fault tolerance. It has great importance for the safety and dependability of the system in practical industrial applications. In this context, the article studies some fault-tolerant strategies of the proposed qZS-ANPC inverter under $S_{a1}, S_{a2}$ , or $S_{a5}$ open-circuit fault. The relevant fault-tolerant strategy is designed for each device fault, including reconstructing the topology, changing the modulation signals, and adjusting the values of shoot-through duty cycle and modulation index. This enables the inverter to operate continuously under open-circuit fault conditions, substantially improving the reliability and robustness of the system. Moreover, the proposed solution does not add extra components to the three-level qZS-ANPC inverter, which has low robust operating cost and is convenient for engineering implementation. Finally, the validity of proposed strategies and high reliability of this inverter topology are confirmed by simulations.- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1469-1474
Open-Circuit Fault-Tolerant Operation for Three-Level Quasi-Z-Source Active Neutral Point Clamped Inverter
The article proposes a novel topology of three-level quasi-Z-source active neutral point clamped (qZS-ANPC) inverter that connects the dc power supply to an active neutral point clamped (ANPC) three-level inverter through an intermediate network. Besides the buck-boost function, this topology also provides the potential for fault tolerance. It has great importance for the safety and dependability of the system in practical industrial applications. In this context, the article studies some fault-tolerant strategies of the proposed qZS-ANPC inverter under $S_{a1}, S_{a2}$ , or $S_{a5}$ open-circuit fault. The relevant fault-tolerant strategy is designed for each device fault, including reconstructing the topology, changing the modulation signals, and adjusting the values of shoot-through duty cycle and modulation index. This enables the inverter to operate continuously under open-circuit fault conditions, substantially improving the reliability and robustness of the system. Moreover, the proposed solution does not add extra components to the three-level qZS-ANPC inverter, which has low robust operating cost and is convenient for engineering implementation. Finally, the validity of proposed strategies and high reliability of this inverter topology are confirmed by simulations.- 4 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 19 (9) , 9733-9744
Passivity-Based Control Method for Three-Level Photovoltaic Inverter to Mitigate Common-Mode Resonant Current
In transformerless three-level photovoltaic inverter systems, the modified LC filter, which directly connects the dc-side neutral point to the common point of filter capacitors, is considered to be an ideal scheme to suppress the troublesome leakage current. However, a new common-mode (CM) resonant current is emerged, which leads to inverter-side current distortion and even system instability. Therefore, a second-order passivity-based controller in the time domain featuring excellent system stability is proposed for the CM resonant current mitigation. First, the reason for the CM resonant current generation with the modified LC filter is analyzed in detail. Then, the CM current model is derived, which reveals that it is a second-order system. The passivity of this second-order model is strictly proved. Moreover, based on the passive control theory, zero state detectable theory, and Lyapunov stability theorem, a second-order passivity-based controller is designed step by step to suppress the CM resonant current, and the system global asymptotic stability is also proved. The proposed controller is based on the time domain, which is more intuitive and avoids the error amplification in the conversion from frequency domain to time domain. Finally, the effectiveness and the correctness of the theoretical derivation of the passivity-based control method are validated by experiments. Compared with the passive damping resistor method, the proposed method not only has better performance but also avoids the use of real resistors and reduces the cost by using software instead of hardware.
- 4 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 19 (9) , 9733-9744
Passivity-Based Control Method for Three-Level Photovoltaic Inverter to Mitigate Common-Mode Resonant Current
In transformerless three-level photovoltaic inverter systems, the modified LC filter, which directly connects the dc-side neutral point to the common point of filter capacitors, is considered to be an ideal scheme to suppress the troublesome leakage current. However, a new common-mode (CM) resonant current is emerged, which leads to inverter-side current distortion and even system instability. Therefore, a second-order passivity-based controller in the time domain featuring excellent system stability is proposed for the CM resonant current mitigation. First, the reason for the CM resonant current generation with the modified LC filter is analyzed in detail. Then, the CM current model is derived, which reveals that it is a second-order system. The passivity of this second-order model is strictly proved. Moreover, based on the passive control theory, zero state detectable theory, and Lyapunov stability theorem, a second-order passivity-based controller is designed step by step to suppress the CM resonant current, and the system global asymptotic stability is also proved. The proposed controller is based on the time domain, which is more intuitive and avoids the error amplification in the conversion from frequency domain to time domain. Finally, the effectiveness and the correctness of the theoretical derivation of the passivity-based control method are validated by experiments. Compared with the passive damping resistor method, the proposed method not only has better performance but also avoids the use of real resistors and reduces the cost by using software instead of hardware.
- 30 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 6297-6309
Leakage Current Suppression of Transformerless 5L-ANPC Inverter With Lower Ripple Model Predictive Control
The five-level active neutral-point-clamped (5L-ANPC) inverter has been applied to increase the power capacity of photovoltaic (PV) systems. However, this type of configuration requires to balance neutral point (NP) voltage and flying capacitor (FC) voltage properly. For the operation of the transformerless five-level inverter, another requirement is to suppress the leakage current associated with the common-mode voltage (CMV) vectors. Due to the mutually coupled issues, the conventional model predictive control (MPC) methods reported so far cannot deal with them properly at the same time. To address these problems, a novel double-vector MPC (DV-MPC) strategy with zero CMV vector is proposed in this article. First, 19 voltage vectors with zero CMV are implemented as candidate vectors. Then, for the purpose to reduce output current ripples, two voltage vectors are penalized by the cost function without weighting factors to track the reference voltage. In addition, the dwell times are optimized to further mitigate current ripples. Finally, to avoid the sharply increasing computational burden of the online iteration caused by the introduction of the second vector and its corresponding redundant switching states, a voltage-balance strategy is presented for the DV-MPC method, which can determine the suitable switching combinations directly and adapt them to the selected vectors to balance the voltages of the NP and FCs together. The effectiveness of the proposed method is verified by the simulation and experiment at the end of this article.
- 30 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 6297-6309
Leakage Current Suppression of Transformerless 5L-ANPC Inverter With Lower Ripple Model Predictive Control
The five-level active neutral-point-clamped (5L-ANPC) inverter has been applied to increase the power capacity of photovoltaic (PV) systems. However, this type of configuration requires to balance neutral point (NP) voltage and flying capacitor (FC) voltage properly. For the operation of the transformerless five-level inverter, another requirement is to suppress the leakage current associated with the common-mode voltage (CMV) vectors. Due to the mutually coupled issues, the conventional model predictive control (MPC) methods reported so far cannot deal with them properly at the same time. To address these problems, a novel double-vector MPC (DV-MPC) strategy with zero CMV vector is proposed in this article. First, 19 voltage vectors with zero CMV are implemented as candidate vectors. Then, for the purpose to reduce output current ripples, two voltage vectors are penalized by the cost function without weighting factors to track the reference voltage. In addition, the dwell times are optimized to further mitigate current ripples. Finally, to avoid the sharply increasing computational burden of the online iteration caused by the introduction of the second vector and its corresponding redundant switching states, a voltage-balance strategy is presented for the DV-MPC method, which can determine the suitable switching combinations directly and adapt them to the selected vectors to balance the voltages of the NP and FCs together. The effectiveness of the proposed method is verified by the simulation and experiment at the end of this article.
- 22 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (6) , 6810-6821
Hybrid Space Vector Modulation Scheme to Reduce Common-Mode Voltage Magnitude and Frequency in Three-Level Quasi-Z-Source Inverter
The three-level quasi-Z-source inverter (TLQZSI) is an attractive topology that is suitable for voltage buck and boost operation. This paper further presents a hybrid space vector modulation (HSVM) scheme to reduce the common-mode voltage (CMV) magnitude and frequency simultaneously. At first, the selection of basic vectors is optimized. Six medium vectors, six small vectors that have low CMV magnitudes, one zero vector, and three shoot-through vectors are utilized to produce the ac output voltage. The shoot-through state is properly inserted within the zero vector without affecting the normal ac output voltage. The effective small vector is selected according to the neutral-point voltage (NPV). Duty cycles of the adopted vectors are updated accordingly, and the restriction of the duty cycle of effective small vector is also derived. When comparing with the conventional SVM method, the CMV magnitude for the proposed scheme is suppressed by half. Furthermore, the CMV frequency is reduced by comparison to the conventional CMV reduction method. The feasibility of the proposed scheme has been tested by using Simulink platform and a hardware-based test rig.
- 22 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (6) , 6810-6821
Hybrid Space Vector Modulation Scheme to Reduce Common-Mode Voltage Magnitude and Frequency in Three-Level Quasi-Z-Source Inverter
The three-level quasi-Z-source inverter (TLQZSI) is an attractive topology that is suitable for voltage buck and boost operation. This paper further presents a hybrid space vector modulation (HSVM) scheme to reduce the common-mode voltage (CMV) magnitude and frequency simultaneously. At first, the selection of basic vectors is optimized. Six medium vectors, six small vectors that have low CMV magnitudes, one zero vector, and three shoot-through vectors are utilized to produce the ac output voltage. The shoot-through state is properly inserted within the zero vector without affecting the normal ac output voltage. The effective small vector is selected according to the neutral-point voltage (NPV). Duty cycles of the adopted vectors are updated accordingly, and the restriction of the duty cycle of effective small vector is also derived. When comparing with the conventional SVM method, the CMV magnitude for the proposed scheme is suppressed by half. Furthermore, the CMV frequency is reduced by comparison to the conventional CMV reduction method. The feasibility of the proposed scheme has been tested by using Simulink platform and a hardware-based test rig.
- 1 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (1) , 642-652
Improved Particle Swarm Optimization Based Selective Harmonic Elimination and Neutral Point Balance Control for Three-Level Inverter in Low-Voltage Ride-Through Operation
In high-power applications, selective harmonic elimination pulsewidth modulation (SHEPWM) method is widely used to eliminate low-order harmonics in three-level inverters with low power losses. However, it faces the challenges that the conventional optimization methods for solving harmonic elimination equations in SHEPWM are easy to be trapped in local optimum. Moreover, the neutral point (NP) voltage of three-level inverter cannot be balanced under low-voltage ride-through (LVRT) condition with conventional SHEPWM method. To address these problems, a SHEPWM scheme is proposed, which is on the basis of an improved particle swarm optimization (IPSO) algorithm to solve the harmonic elimination equations and an enhanced NP balance control method in LVRT operation. First, an IPSO algorithm is proposed to calculate the switching angles of the transcendental equations for harmonic elimination. The IPSO algorithm defines a nonlinear negative exponential inertia weight considering the current and optimal fitness value, which can dynamically adjust the local and global searching speed and step size according to the actual situation, greatly improving the convergence speed and solution accuracy and avoiding falling into the local optimum. Then, by increasing the degree of freedom of the output current direction and combining with the NP voltage deviation, an enhanced NP voltage balance control method of SHEPWM in LVRT operation is proposed. The validity of the proposed method is proved by simulation and experimental results.
- 1 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 18 (1) , 642-652
Improved Particle Swarm Optimization Based Selective Harmonic Elimination and Neutral Point Balance Control for Three-Level Inverter in Low-Voltage Ride-Through Operation
In high-power applications, selective harmonic elimination pulsewidth modulation (SHEPWM) method is widely used to eliminate low-order harmonics in three-level inverters with low power losses. However, it faces the challenges that the conventional optimization methods for solving harmonic elimination equations in SHEPWM are easy to be trapped in local optimum. Moreover, the neutral point (NP) voltage of three-level inverter cannot be balanced under low-voltage ride-through (LVRT) condition with conventional SHEPWM method. To address these problems, a SHEPWM scheme is proposed, which is on the basis of an improved particle swarm optimization (IPSO) algorithm to solve the harmonic elimination equations and an enhanced NP balance control method in LVRT operation. First, an IPSO algorithm is proposed to calculate the switching angles of the transcendental equations for harmonic elimination. The IPSO algorithm defines a nonlinear negative exponential inertia weight considering the current and optimal fitness value, which can dynamically adjust the local and global searching speed and step size according to the actual situation, greatly improving the convergence speed and solution accuracy and avoiding falling into the local optimum. Then, by increasing the degree of freedom of the output current direction and combining with the NP voltage deviation, an enhanced NP voltage balance control method of SHEPWM in LVRT operation is proposed. The validity of the proposed method is proved by simulation and experimental results.
- 15 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 4009-4024
A Hybrid Passivity-Based Control Strategy for Three-Level T-Type Inverter in LVRT Operation
Fast dynamic performance of photovoltaic (PV) inverter is one of the most important issues in low-voltage ride-through (LVRT) operation, as the voltage dip period is short. Nevertheless, it is difficult to control the output currents with conventional methods, especially during transients or under low power factor operation. In order to satisfy the LVRT requirements and improve the performances of three-level T-type inverter (3LT2I) in PV system, the hybrid passivity-based control (HPBC) strategy with fast transient response and strong robustness to system parameter changes and external disturbances is proposed in this paper. Firstly, the Euler-Lagrange model of 3LT2I under LVRT condition is derived and analyzed. Then, the 3LT2I system is theoretically proved to be strictly passive by using some ingenious arithmetic and differential calculation techniques. Furthermore, based on error energy function and Lyapunov stability criterion, a passivity-based controller including negative-sequence of grid voltage feedforward control terms is designed to suppress the negative-sequence currents effectively. The balanced grid currents are obtained, which improve the stability of the system in LVRT operation. Compared with conventional methods, the proposed HPBC scheme has the superior characteristics of fast and non-overshoot response in transient state and accurate current tracking performance in steady-state. The theoretical analysis and effectiveness of the proposed strategy have been validated by means of both simulations and experiments.
- 15 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 4009-4024
A Hybrid Passivity-Based Control Strategy for Three-Level T-Type Inverter in LVRT Operation
Fast dynamic performance of photovoltaic (PV) inverter is one of the most important issues in low-voltage ride-through (LVRT) operation, as the voltage dip period is short. Nevertheless, it is difficult to control the output currents with conventional methods, especially during transients or under low power factor operation. In order to satisfy the LVRT requirements and improve the performances of three-level T-type inverter (3LT2I) in PV system, the hybrid passivity-based control (HPBC) strategy with fast transient response and strong robustness to system parameter changes and external disturbances is proposed in this paper. Firstly, the Euler-Lagrange model of 3LT2I under LVRT condition is derived and analyzed. Then, the 3LT2I system is theoretically proved to be strictly passive by using some ingenious arithmetic and differential calculation techniques. Furthermore, based on error energy function and Lyapunov stability criterion, a passivity-based controller including negative-sequence of grid voltage feedforward control terms is designed to suppress the negative-sequence currents effectively. The balanced grid currents are obtained, which improve the stability of the system in LVRT operation. Compared with conventional methods, the proposed HPBC scheme has the superior characteristics of fast and non-overshoot response in transient state and accurate current tracking performance in steady-state. The theoretical analysis and effectiveness of the proposed strategy have been validated by means of both simulations and experiments.