Jorge García
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jorge García has a total of 161 co-authors. Here are the top co-authors by number of shared publications:
- Victoria Ramos
Telemedicine and eHealth Research Unit, Health Institute Carlos III, Madrid, Spain
3 shared publications - Alberto Pérez de Rada Fiol
CIEMAT, Madrid, Spain
2 shared publications - Daniel Cano Ott
CIEMAT, Madrid, Spain
2 shared publications - David Villamarin
CIEMAT, Madrid, Spain
2 shared publications - Emilio Mendoza
Centro de Investigaciones Energeticas Medioambientales y Tecnológicas (CIEMAT), 28040 Madrid, Spain
2 shared publications - Silvia de Miguel-Bilbao
Telemedicine and Digital Health Research Unit, Instituto de Salud Carlos III, Madrid, Spain
2 shared publications
Latest Publications
- Open Access
- 5 December 2025
- Published by Elsevier in Physics Letters B
- Vol. 872
Low-uncertainty measurement of the 239Pu(n,f) cross section at n_TOF in a very broad energy range from 0.02 eV up to 10 MeV
- 5 December 2025
- Published by Elsevier in Physics Letters B
- Vol. 872
Open AccessLow-uncertainty measurement of the 239Pu(n,f) cross section at n_TOF in a very broad energy range from 0.02 eV up to 10 MeV
- 14 November 2014
- Published by Wiley in Bioelectromagnetics
- Vol. 36 (2) , 118-132
Assessment of human body influence on exposure measurements of electric field in indoor enclosures
Personal exposure meters (PEMs) used for measuring exposure to electromagnetic fields (EMF) are typically used in epidemiological studies. As is well known, these measurement devices cause a perturbation of real EMF exposure levels due to the presence of the human body in the immediate proximity. This paper aims to model the alteration caused by the body shadow effect (BSE) in motion conditions and in indoor enclosures at the Wi‐Fi frequency of 2.4 GHz. For this purpose, simulation techniques based on ray‐tracing have been carried out, and their results have been verified experimentally. A good agreement exists between simulation and experimental results in terms of electric field (E‐field) levels, and taking into account the cumulative distribution function (CDF) of the spatial distribution of amplitude. The Kolmogorov–Smirnov (KS) test provides a P‐value greater than 0.05, in fact close to 1. It has been found that the influence of the presence of the human body can be characterized as an angle of shadow that depends on the dimensions of the indoor enclosure. The CDFs show that the E‐field levels in indoor conditions follow a lognormal distribution in the absence of the human body and under the influence of BSE. In conclusion, the perturbation caused by BSE in PEMs readings cannot be compensated for by correction factors. Although the mean value is well adjusted, BSE causes changes in CDF that would require improvements in measurement protocols and in the design of measuring devices to subsequently avoid systematic errors. Bioelectromagnetics. 36:118–132, 2015.
- 14 November 2014
- Published by Wiley in Bioelectromagnetics
- Vol. 36 (2) , 118-132
Assessment of human body influence on exposure measurements of electric field in indoor enclosures
Personal exposure meters (PEMs) used for measuring exposure to electromagnetic fields (EMF) are typically used in epidemiological studies. As is well known, these measurement devices cause a perturbation of real EMF exposure levels due to the presence of the human body in the immediate proximity. This paper aims to model the alteration caused by the body shadow effect (BSE) in motion conditions and in indoor enclosures at the Wi‐Fi frequency of 2.4 GHz. For this purpose, simulation techniques based on ray‐tracing have been carried out, and their results have been verified experimentally. A good agreement exists between simulation and experimental results in terms of electric field (E‐field) levels, and taking into account the cumulative distribution function (CDF) of the spatial distribution of amplitude. The Kolmogorov–Smirnov (KS) test provides a P‐value greater than 0.05, in fact close to 1. It has been found that the influence of the presence of the human body can be characterized as an angle of shadow that depends on the dimensions of the indoor enclosure. The CDFs show that the E‐field levels in indoor conditions follow a lognormal distribution in the absence of the human body and under the influence of BSE. In conclusion, the perturbation caused by BSE in PEMs readings cannot be compensated for by correction factors. Although the mean value is well adjusted, BSE causes changes in CDF that would require improvements in measurement protocols and in the design of measuring devices to subsequently avoid systematic errors. Bioelectromagnetics. 36:118–132, 2015.
- 1 January 2014
- Published by Springer Nature
- p. 1159-1162
Assessment of Statistical Distribution of Exposure to Electromagnetic Fields from Social Alarm Devices
- 1 January 2014
- Published by Springer Nature
- p. 1159-1162
Assessment of Statistical Distribution of Exposure to Electromagnetic Fields from Social Alarm Devices
- 1 January 2009
- Published by Springer Nature
- p. 57-60
Assessment on a Safe use of a Home Telemedicine System regarding Electromagnetic Compatibility
- 1 January 2009
- Published by Springer Nature
- p. 57-60
Assessment on a Safe use of a Home Telemedicine System regarding Electromagnetic Compatibility