Jegyasu Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jegyasu Gupta has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Debabrata Sikdar
Department of Electronics and Electrical Engineering Indian Institute of Technology Guwahati Guwahati India
4 shared publications Debabrata Sikdar
Department of Electronics and Electrical Engineering, Indian Institute of Technology, Guwahati, Assam, India
3 shared publicationsRatnajit Bhattacharjee
Department of Electronics and Electrical Engineering, Indian Institute of Technology, Guwahati, Assam, India
3 shared publications- Ratnajit Bhattacharjee
IIT Guwahati
3 shared publications Priyanka Das
Department of Electronics and Electrical Engineering, Indian Institute of Technology Guwahati, Guwahati, India
2 shared publications- Subramani Kanagaraj
Department of Mechanical Engineering Indian Institute of Technology Guwahati Guwahati India
2 shared publications
Latest Publications
- 6 February 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (3) , 149
Smart and flexible metasurface-inspired wraps as “Add-ons” for enhanced magnetic resonance imaging
- 6 February 2026
- Published by Springer Nature in Applied Physics A
- Vol. 132 (3) , 149
Smart and flexible metasurface-inspired wraps as “Add-ons” for enhanced magnetic resonance imaging
- 16 July 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (16)
Flexible and Wearable Metasurfaces of Spiral Quartet Arrays for Boosting Signal‐to‐Noise Ratio of 1.5T Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) has established itself as a cornerstone imaging modality in modern radiology, delivering high‐resolution insights for comprehensive disease detection and therapeutic monitoring. Metamaterials have significantly advanced MRI imaging capabilities by enhancing signal‐to‐noise ratio (SNR) through their remarkable ability to confine and amplify electromagnetic fields when placed as clinical add‐ons between patients and transceiver arrays. However, considerable obstacles continue to hinder the widespread clinical adoption of conventional metamaterials, mainly because of their bulky and rigid designs, along with inability to adapt to varying anatomies of different subjects. Herein, to resolve these limitations, this study introduces a flexible metasurface (MS) of spiral quartet arrays for boosting SNR of 1.5T MRI, enabling efficient imaging of body‐parts with varying curvatures. Numerical analyses reveal that the MS provides high magnetic field localization within phantom and human biomodel. Laboratory experiments of developed MS demonstrate a peak enhancement of sixfold in the magnetic fields inside phantom wrapped with MS. In addition, MRI scans acquired using designed MS achieve a fourfold boost in SNR compared to those obtained using only receiver coils. Thus, the developed flexible MS presents an opportunity for creating metamaterial‐based devices as clinical accessories, facilitating more efficient, faster, and cost‐effective MRI scans.
- 16 July 2025
- Published by Wiley in Advanced Engineering Materials
- Vol. 27 (16)
Flexible and Wearable Metasurfaces of Spiral Quartet Arrays for Boosting Signal‐to‐Noise Ratio of 1.5T Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) has established itself as a cornerstone imaging modality in modern radiology, delivering high‐resolution insights for comprehensive disease detection and therapeutic monitoring. Metamaterials have significantly advanced MRI imaging capabilities by enhancing signal‐to‐noise ratio (SNR) through their remarkable ability to confine and amplify electromagnetic fields when placed as clinical add‐ons between patients and transceiver arrays. However, considerable obstacles continue to hinder the widespread clinical adoption of conventional metamaterials, mainly because of their bulky and rigid designs, along with inability to adapt to varying anatomies of different subjects. Herein, to resolve these limitations, this study introduces a flexible metasurface (MS) of spiral quartet arrays for boosting SNR of 1.5T MRI, enabling efficient imaging of body‐parts with varying curvatures. Numerical analyses reveal that the MS provides high magnetic field localization within phantom and human biomodel. Laboratory experiments of developed MS demonstrate a peak enhancement of sixfold in the magnetic fields inside phantom wrapped with MS. In addition, MRI scans acquired using designed MS achieve a fourfold boost in SNR compared to those obtained using only receiver coils. Thus, the developed flexible MS presents an opportunity for creating metamaterial‐based devices as clinical accessories, facilitating more efficient, faster, and cost‐effective MRI scans.
- 7 November 2024
- Published by Wiley in Advanced Theory and Simulations
- Vol. 8 (2)
Improving Signal‐to‐Noise Ratio of 1.5T MRI Scans Using High‐Q Resonators Based on Coupled Octa‐Spirals
Metamaterials or metamaterial‐inspired structures/resonators have yielded significant advancement in the imaging capabilities of Magnetic Resonance Imaging (MRI) by boosting its performance parameter, i.e., signal‐to‐noise ratio (SNR). Metamaterials have a distinctive ability to boost and redistribute magnetic fields inside the subject undergoing scan when integrated as accessories between receive arrays and the subject. However, the translation of most reported metamaterials into a clinical accessory is still limited and challenging due to their low sensitivity, sub‐optimal performance, and bulky footprints for integration inside MRI scanners. Herein, a metamaterial‐inspired structure is developed using coupled octa‐spiral resonators to boost magnetic field localization inside the scanned region. In addition, the high‐Q resonance of the metamaterial‐inspired structure improves impedance matching and enhances the transmit/receive efficiency of MRI coils. Theoretical analysis of electromagnetic responses and full‐wave simulations show a homogeneous boost in SNR by over times throughout a human‐properties mimicking phantom using the resonator with a maximum SNR enhancement factor (EF) of . The spatial distribution of SNR EF inside the phantom is also validated by preliminary laboratory experiments. Thus, the developed coupled octa‐spirals resonator can pave the way for developing and adopting metamaterial‐inspired devices as clinical accessories for facilitating better, faster, and cost‐effective MRI scans.
- 7 November 2024
- Published by Wiley in Advanced Theory and Simulations
- Vol. 8 (2)
Improving Signal‐to‐Noise Ratio of 1.5T MRI Scans Using High‐Q Resonators Based on Coupled Octa‐Spirals
Metamaterials or metamaterial‐inspired structures/resonators have yielded significant advancement in the imaging capabilities of Magnetic Resonance Imaging (MRI) by boosting its performance parameter, i.e., signal‐to‐noise ratio (SNR). Metamaterials have a distinctive ability to boost and redistribute magnetic fields inside the subject undergoing scan when integrated as accessories between receive arrays and the subject. However, the translation of most reported metamaterials into a clinical accessory is still limited and challenging due to their low sensitivity, sub‐optimal performance, and bulky footprints for integration inside MRI scanners. Herein, a metamaterial‐inspired structure is developed using coupled octa‐spiral resonators to boost magnetic field localization inside the scanned region. In addition, the high‐Q resonance of the metamaterial‐inspired structure improves impedance matching and enhances the transmit/receive efficiency of MRI coils. Theoretical analysis of electromagnetic responses and full‐wave simulations show a homogeneous boost in SNR by over times throughout a human‐properties mimicking phantom using the resonator with a maximum SNR enhancement factor (EF) of . The spatial distribution of SNR EF inside the phantom is also validated by preliminary laboratory experiments. Thus, the developed coupled octa‐spirals resonator can pave the way for developing and adopting metamaterial‐inspired devices as clinical accessories for facilitating better, faster, and cost‐effective MRI scans.
- 23 September 2023
- Published by Springer Nature in Applied Physics A
- Vol. 129 (10) , 1-12
Enhancing signal-to-noise ratio of clinical 1.5T MRI using metasurface-inspired flexible wraps
- 23 September 2023
- Published by Springer Nature in Applied Physics A
- Vol. 129 (10) , 1-12
Enhancing signal-to-noise ratio of clinical 1.5T MRI using metasurface-inspired flexible wraps
- Open Access
- 20 September 2023
- Published by Elsevier in Results in Physics
- Vol. 53
Resonating sub-wavelength metallic wires based pads for boosting signal-to-noise ratio of birdcage head coils at 1.5T MRI
- 20 September 2023
- Published by Elsevier in Results in Physics
- Vol. 53
Open AccessResonating sub-wavelength metallic wires based pads for boosting signal-to-noise ratio of birdcage head coils at 1.5T MRI
- 4 July 2023
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 35 (39) , 395701
Electro-tunable metasurface for tri-state dynamic polarization switching at near-infrared wavelengths
Control of polarization states of light is crucial for any photonic system. However, conventional polarization-controlling elements are typically static and bulky. Metasurfaces open a new paradigm to realize flat optical components by engineering meta-atoms at sub-wavelength scale. Tunable metasurfaces can provide enormous degrees-of-freedom to tailor electromagnetic properties of light and thus have the potential to realize dynamic polarization control in nanoscale. In this study, we propose a novel electro-tunable metasurface to enable dynamic control of polarization states of reflected light. The proposed metasurface comprises a two-dimensional array of elliptical Ag-nanopillars deposited on indium-tin-oxide (ITO)–Al2O3–Ag stack. In unbiased condition, excitation of gap-plasmon resonance in the metasurface leads to rotation of x-polarized incident light to orthogonally polarized reflected light (i.e., y-polarized) at 1.55 μm. On the other hand, by applying bias-voltage, we can alter the amplitude and phase of the electric field components of the reflected light. With 2 V applied bias, we achieved a linearly polarized reflected light with a polarization angle of −45°. Furthermore, we can tune the epsilon-near-zero wavelength of ITO at the vicinity of 1.55 μm wavelength by increasing the bias to 5 V, which reduces y-component of the electric field to a negligible amplitude, thus, resulting in an x-polarized reflected light. Thus, with an x-polarized incident wave, we can dynamically switch among the three linear polarization states of the reflected wave, allowing a tri-state polarization switching (viz. y-polarization at 0 V, −45° linear polarization at 2 V, and x-polarization at 5 V). The Stokes parameters are also calculated to show a real-time control over light polarization. Thus, the proposed device paves the way toward the realization of dynamic polarization switching in nanophotonic applications.
- 4 July 2023
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 35 (39) , 395701
Electro-tunable metasurface for tri-state dynamic polarization switching at near-infrared wavelengths
Control of polarization states of light is crucial for any photonic system. However, conventional polarization-controlling elements are typically static and bulky. Metasurfaces open a new paradigm to realize flat optical components by engineering meta-atoms at sub-wavelength scale. Tunable metasurfaces can provide enormous degrees-of-freedom to tailor electromagnetic properties of light and thus have the potential to realize dynamic polarization control in nanoscale. In this study, we propose a novel electro-tunable metasurface to enable dynamic control of polarization states of reflected light. The proposed metasurface comprises a two-dimensional array of elliptical Ag-nanopillars deposited on indium-tin-oxide (ITO)–Al2O3–Ag stack. In unbiased condition, excitation of gap-plasmon resonance in the metasurface leads to rotation of x-polarized incident light to orthogonally polarized reflected light (i.e., y-polarized) at 1.55 μm. On the other hand, by applying bias-voltage, we can alter the amplitude and phase of the electric field components of the reflected light. With 2 V applied bias, we achieved a linearly polarized reflected light with a polarization angle of −45°. Furthermore, we can tune the epsilon-near-zero wavelength of ITO at the vicinity of 1.55 μm wavelength by increasing the bias to 5 V, which reduces y-component of the electric field to a negligible amplitude, thus, resulting in an x-polarized reflected light. Thus, with an x-polarized incident wave, we can dynamically switch among the three linear polarization states of the reflected wave, allowing a tri-state polarization switching (viz. y-polarization at 0 V, −45° linear polarization at 2 V, and x-polarization at 5 V). The Stokes parameters are also calculated to show a real-time control over light polarization. Thus, the proposed device paves the way toward the realization of dynamic polarization switching in nanophotonic applications.
- 21 September 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (11) , 114901
A thin metallo-dielectric stacked metamaterial as “add-on” for magnetic field enhancement in clinical MRI
Magnetic resonance imaging (MRI) is a widely used clinical diagnostic tool, which is based on the principle of nuclear magnetic resonance of hydrogen atoms in human body. The Larmor frequency of precession of the hydrogen atoms is determined by the strength of static magnetic field ( B0) of MRI. A higher B0 can directly improve signal-to-noise ratio (SNR) of MRI. However, this method involves expensive hardware installation, which could have adverse effects of tissue-heating and make MRI unsafe for patients with medical implants. Hence, efforts have been made to increase the SNR of MRI without increasing B0. An effective solution in this direction would be to boost the radiofrequency (RF) magnetic fields emitted by the body part undergoing scan, particularly by using metamaterials. The higher the received RF signal strength, the greater the SNR of MRI. For a metamaterial to be used as an “add-on” in commercial scanners, its dimensions need to be designed appropriately so that it fits in the available gap between the transceiver coil and the human body. In this article, a 10-mm-thick metallo-dielectric metamaterial is designed by a stacking of alternate square-shaped capacitive patches and inductive apertures for enhancing the RF magnetic flux density and hence, the SNR of a 1.5 T MRI system. The inter-layer electromagnetic coupling in the stacked structure is deployed for spatial localization of magnetic fields at the resonant frequency (∼64 MHz) which is equal to the Larmor frequency of 1.5 T MRI. An equivalent circuit model, comprising a lumped-element third order bandpass filter, validated the transmissivity characteristics of the metamaterial obtained using full-wave simulations. Magnetic flux density enhancement by a factor of 55 is obtained when the metamaterial add-on is placed between a surface coil and a bio-model of human head.
- 21 September 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (11) , 114901
A thin metallo-dielectric stacked metamaterial as “add-on” for magnetic field enhancement in clinical MRI
Magnetic resonance imaging (MRI) is a widely used clinical diagnostic tool, which is based on the principle of nuclear magnetic resonance of hydrogen atoms in human body. The Larmor frequency of precession of the hydrogen atoms is determined by the strength of static magnetic field ( B0) of MRI. A higher B0 can directly improve signal-to-noise ratio (SNR) of MRI. However, this method involves expensive hardware installation, which could have adverse effects of tissue-heating and make MRI unsafe for patients with medical implants. Hence, efforts have been made to increase the SNR of MRI without increasing B0. An effective solution in this direction would be to boost the radiofrequency (RF) magnetic fields emitted by the body part undergoing scan, particularly by using metamaterials. The higher the received RF signal strength, the greater the SNR of MRI. For a metamaterial to be used as an “add-on” in commercial scanners, its dimensions need to be designed appropriately so that it fits in the available gap between the transceiver coil and the human body. In this article, a 10-mm-thick metallo-dielectric metamaterial is designed by a stacking of alternate square-shaped capacitive patches and inductive apertures for enhancing the RF magnetic flux density and hence, the SNR of a 1.5 T MRI system. The inter-layer electromagnetic coupling in the stacked structure is deployed for spatial localization of magnetic fields at the resonant frequency (∼64 MHz) which is equal to the Larmor frequency of 1.5 T MRI. An equivalent circuit model, comprising a lumped-element third order bandpass filter, validated the transmissivity characteristics of the metamaterial obtained using full-wave simulations. Magnetic flux density enhancement by a factor of 55 is obtained when the metamaterial add-on is placed between a surface coil and a bio-model of human head.
- 13 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (19) , 8775-8780
Simulation and Comprehensive Analysis of Fluoride Fiber SPR Sensor With Multilayer Variants of 2D Materials (Graphene and MoS2) Under Optimum Radiation Damping in NIR
The performance of multiple variants of fluoride fiber plasmonic sensor is simulated and analyzed under optimum radiation damping (ORD) in terms of coordinated tuning of Ag layer thickness (dAg) and near infrared (NIR) wavelength (λ). The sensor variants are in terms of number of monolayers (N: 1 -5) of graphene and MoS2. The dispersion relations of all constituent layers along with transfer matrix method is utilized for sensor simulation. The sensor’s performance is evaluated in terms of figure of merit (FOM) that takes into account the shift and width of fiber power loss resonance curves originating under the plasmonic modulation. Further totality is added to performance evaluation by combining the FOM with signal scattering and power loss ratio factors. The simulation results and their comprehensive analysis indicate that a combination of λ = 925.3 nm, dAg = 48.4 nm, and MoS2 monolayer can provide considerably enhanced performance in terms of maximum FOM, small light signal scattering (and analyte photodamage), and large power loss ratio (with respect to reference resonance curve). The FOM achievable with this sensor is 4.5 times better than the previously reported chalcogenide fiber plasmonic sensor under its corresponding ORD. A deeper analysis of the proposed fluoride sensor predicts that even smaller signal scattering (and photodamage) along with nearly identical power loss ratio and FOM can be achieved with the sensor variant based on MoS2 bilayer.
- 13 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (19) , 8775-8780
Simulation and Comprehensive Analysis of Fluoride Fiber SPR Sensor With Multilayer Variants of 2D Materials (Graphene and MoS2) Under Optimum Radiation Damping in NIR
The performance of multiple variants of fluoride fiber plasmonic sensor is simulated and analyzed under optimum radiation damping (ORD) in terms of coordinated tuning of Ag layer thickness (dAg) and near infrared (NIR) wavelength (λ). The sensor variants are in terms of number of monolayers (N: 1 -5) of graphene and MoS2. The dispersion relations of all constituent layers along with transfer matrix method is utilized for sensor simulation. The sensor’s performance is evaluated in terms of figure of merit (FOM) that takes into account the shift and width of fiber power loss resonance curves originating under the plasmonic modulation. Further totality is added to performance evaluation by combining the FOM with signal scattering and power loss ratio factors. The simulation results and their comprehensive analysis indicate that a combination of λ = 925.3 nm, dAg = 48.4 nm, and MoS2 monolayer can provide considerably enhanced performance in terms of maximum FOM, small light signal scattering (and analyte photodamage), and large power loss ratio (with respect to reference resonance curve). The FOM achievable with this sensor is 4.5 times better than the previously reported chalcogenide fiber plasmonic sensor under its corresponding ORD. A deeper analysis of the proposed fluoride sensor predicts that even smaller signal scattering (and photodamage) along with nearly identical power loss ratio and FOM can be achieved with the sensor variant based on MoS2 bilayer.