Fred Richard Beyette
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fred Richard Beyette has a total of 218 co-authors. Here are the top co-authors by number of shared publications:
C.W. Wilmsen
18 shared publicationsS.A. Feld
17 shared publications- Vignesh Subbian
Department of Biomedical Engineering Department of Biomedical Engineering University of Arizona University of Arizona
14 shared publications K.M. Geib
11 shared publicationsProsenjit Mal
Microprocessor Res. & Dev., Intel Corp., Hillsboro, OR
11 shared publicationsX. An
11 shared publications
Latest Publications
- 4 September 2020
- Published by American Society for Engineering Education
- p. 24.1300.1-24.1300.9
UnLecture: A Novel Active Learning Based Pedagogical Strategy for Engineering Courses
- 4 September 2020
- Published by American Society for Engineering Education
- p. 24.1300.1-24.1300.9
UnLecture: A Novel Active Learning Based Pedagogical Strategy for Engineering Courses
- Open Access
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1168-1171
Physiological health assessment and hazard monitoring patch for firefighters
The objective of this project is to create a novel device to monitor and report back with comprehensive physiological status and alerts of hazards encountered by the firefighter. The device is a band-aid like device that would be attached to the firefighter's skin positioned on the upper arm. The device would monitor the firefighter's physiological health including heart rate and blood oxygen level, carboxyhemoglobin, and hyperthermia. Not only will the device monitor the firefighter's physiological health, it will also monitor and report back on the temperature and humidity inside the firefighter's suit, and monitor for impacts, falls, impact from objects or contact with objects.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1168-1171
Open AccessPhysiological health assessment and hazard monitoring patch for firefighters
The objective of this project is to create a novel device to monitor and report back with comprehensive physiological status and alerts of hazards encountered by the firefighter. The device is a band-aid like device that would be attached to the firefighter's skin positioned on the upper arm. The device would monitor the firefighter's physiological health including heart rate and blood oxygen level, carboxyhemoglobin, and hyperthermia. Not only will the device monitor the firefighter's physiological health, it will also monitor and report back on the temperature and humidity inside the firefighter's suit, and monitor for impacts, falls, impact from objects or contact with objects.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1469-1472
Electrochemical impedance spectroscopy circuitry for biosensor applications
Electrochemical Impedance Spectroscopy is widely popular in the medical field where it is often referred to as bioelectrical impedance analysis (BIA) used to analyze biological materials as well as characterization of body fluids. It is a complex technique requiring expensive equipment that is also large making it difficult to integrate into small form-factor systems that are hand-held, wearable and intended for use in point-of-care testing. This paper presents a prototype design of a miniaturized and low cost EIS module aimed to render effective point-of-care testing of biomarkers from body fluids. The proposed system is based on an embedded system design to be factored to achieve small valuation time for results along with being compact and portable enough to be used outside laboratory bench setting.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1469-1472
Electrochemical impedance spectroscopy circuitry for biosensor applications
Electrochemical Impedance Spectroscopy is widely popular in the medical field where it is often referred to as bioelectrical impedance analysis (BIA) used to analyze biological materials as well as characterization of body fluids. It is a complex technique requiring expensive equipment that is also large making it difficult to integrate into small form-factor systems that are hand-held, wearable and intended for use in point-of-care testing. This paper presents a prototype design of a miniaturized and low cost EIS module aimed to render effective point-of-care testing of biomarkers from body fluids. The proposed system is based on an embedded system design to be factored to achieve small valuation time for results along with being compact and portable enough to be used outside laboratory bench setting.
- Open Access
- 25 January 2016
- Published by Wiley in Academic Emergency Medicine
- Vol. 23 (4) , 382-392
A Novel Tool for Evaluation of Mild Traumatic Brain Injury Patients in the Emergency Department: Does Robotic Assessment of Neuromotor Performance Following Injury Predict the Presence of Postconcussion Symptoms at Follow‐up?
Objectives: Postconcussion symptoms (PCS) are a common complication of mild traumatic brain injury (TBI). Currently, there is no validated clinically available method to reliably predict at the time of injury who will subsequently develop PCS. The purpose of this study was to determine if PCS following mild TBI can be predicted during the initial presentation to an emergency department (ED) using a novel robotic‐assisted assessment of neurologic function.Methods: All patients presenting to an urban ED with a chief complaint of head injury within the preceding 24 hours were screened for inclusion from March 2013 to April 2014. The enrollment criteria were as follows: 1) age of 18 years or greater, 2) ability and willingness to provide written informed consent, 3) blunt head trauma and clinical diagnosis of isolated mild TBI by the treating physician, and 4) blood alcohol level of <100 mg/dL. Eligible mild TBI patients were enrolled and their neuromotor function was assessed in the ED using a battery of five tests that cover a range of proprioceptive, visuomotor, visuospatial, and executive function performance metrics. At 3 weeks postinjury, participants were contacted via telephone to complete the Rivermead Post‐Concussion Symptoms Questionnaire to assess the presence of significant PCS.Results: A total of 66 mild TBI patients were enrolled in the study with 42 of them completing both the ED assessment and the follow‐up; 40 patients were included in the analyses. The area under the receiver operating characteristic curve (AUC) for the entire test battery was 0.72 (95% confidence interval [CI] = 0.54 to 0.90). The AUC for tests that primarily measure visuomotor and proprioceptive performance were 0.80 (95% CI = 0.65 to 0.95) and 0.71 (95% CI = 0.53 to 0.89), respectively.Conclusions: The robotic‐assisted test battery has the ability to discriminate between subjects who developed PCS and those who did not. Additionally, poor visuomotor and proprioceptive performance were most strongly associated with subsequent PCS.
- 25 January 2016
- Published by Wiley in Academic Emergency Medicine
- Vol. 23 (4) , 382-392
Open AccessA Novel Tool for Evaluation of Mild Traumatic Brain Injury Patients in the Emergency Department: Does Robotic Assessment of Neuromotor Performance Following Injury Predict the Presence of Postconcussion Symptoms at Follow‐up?
Objectives: Postconcussion symptoms (PCS) are a common complication of mild traumatic brain injury (TBI). Currently, there is no validated clinically available method to reliably predict at the time of injury who will subsequently develop PCS. The purpose of this study was to determine if PCS following mild TBI can be predicted during the initial presentation to an emergency department (ED) using a novel robotic‐assisted assessment of neurologic function.Methods: All patients presenting to an urban ED with a chief complaint of head injury within the preceding 24 hours were screened for inclusion from March 2013 to April 2014. The enrollment criteria were as follows: 1) age of 18 years or greater, 2) ability and willingness to provide written informed consent, 3) blunt head trauma and clinical diagnosis of isolated mild TBI by the treating physician, and 4) blood alcohol level of <100 mg/dL. Eligible mild TBI patients were enrolled and their neuromotor function was assessed in the ED using a battery of five tests that cover a range of proprioceptive, visuomotor, visuospatial, and executive function performance metrics. At 3 weeks postinjury, participants were contacted via telephone to complete the Rivermead Post‐Concussion Symptoms Questionnaire to assess the presence of significant PCS.Results: A total of 66 mild TBI patients were enrolled in the study with 42 of them completing both the ED assessment and the follow‐up; 40 patients were included in the analyses. The area under the receiver operating characteristic curve (AUC) for the entire test battery was 0.72 (95% confidence interval [CI] = 0.54 to 0.90). The AUC for tests that primarily measure visuomotor and proprioceptive performance were 0.80 (95% CI = 0.65 to 0.95) and 0.71 (95% CI = 0.53 to 0.89), respectively.Conclusions: The robotic‐assisted test battery has the ability to discriminate between subjects who developed PCS and those who did not. Additionally, poor visuomotor and proprioceptive performance were most strongly associated with subsequent PCS.
- 17 August 2015
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 21 (5) , 528-534
Experimental desktop 3D printing using dual extrusion and water-soluble polyvinyl alcohol
Purpose: – This paper aims to discuss the use of polyvinyl alcohol (PVA) as a water-soluble support material in desktop three-dimensional (3D) printing. Using a water-soluble material as one of the printing filaments in a dual-extrusion 3D printer provides the flexibility of printing support structures and rafts in complex components and prototypes. This paper focuses on the challenges of acrylonitrile butadiene styrene (ABS)–PVA dual-extrusion printing, and optimal settings and techniques for such hybrid printing. Design/methodology/approach: – Several hybrid ABS–PVA parts were printed using a commercial desktop 3D printer. An experimental study was designed to examine the solubility of the PVA support in water by varying four different parameters: length of time in water, water temperature, stirring rate and PVA surface area. The rate of PVA solubility in water was then used to examine its relationship with each parameter. Findings: – Numerous problems were encountered while printing ABS–PVA printing parts, including storing the spool of PVA in a dry environment, determining optimal extrusion and build plate temperatures and ABS–PVA adherence during dual extrusion printing. There is no strong literature to address these challenges. Hence, optimal settings and techniques for effective hybrid ABS–PVA were determined. Print yields were also recorded to examine the reliability of ABS–PVA printing. Research limitations/implications: – The tendency of PVA to absorb moisture resulted in a number of build fails and prevented build times longer than 40 minutes. Future work can explore how to print PVA directly from a dry environment. Practical implications: – The optimal settings and techniques for dual-extrusion ABS–PVA printing that are presented in this paper can effectively be used to explore prototyping of geometrically complex parts with PVA as support material. Originality/value: – In addition to the practical implications, the results from this work are a valuable addition to the literature related to printing using water-soluble polymers such as PVA. The experimental methods and techniques of this paper can be used to assess the reliability of similar 3D printing technologies.
- 17 August 2015
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 21 (5) , 528-534
Experimental desktop 3D printing using dual extrusion and water-soluble polyvinyl alcohol
Purpose: – This paper aims to discuss the use of polyvinyl alcohol (PVA) as a water-soluble support material in desktop three-dimensional (3D) printing. Using a water-soluble material as one of the printing filaments in a dual-extrusion 3D printer provides the flexibility of printing support structures and rafts in complex components and prototypes. This paper focuses on the challenges of acrylonitrile butadiene styrene (ABS)–PVA dual-extrusion printing, and optimal settings and techniques for such hybrid printing. Design/methodology/approach: – Several hybrid ABS–PVA parts were printed using a commercial desktop 3D printer. An experimental study was designed to examine the solubility of the PVA support in water by varying four different parameters: length of time in water, water temperature, stirring rate and PVA surface area. The rate of PVA solubility in water was then used to examine its relationship with each parameter. Findings: – Numerous problems were encountered while printing ABS–PVA printing parts, including storing the spool of PVA in a dry environment, determining optimal extrusion and build plate temperatures and ABS–PVA adherence during dual extrusion printing. There is no strong literature to address these challenges. Hence, optimal settings and techniques for effective hybrid ABS–PVA were determined. Print yields were also recorded to examine the reliability of ABS–PVA printing. Research limitations/implications: – The tendency of PVA to absorb moisture resulted in a number of build fails and prevented build times longer than 40 minutes. Future work can explore how to print PVA directly from a dry environment. Practical implications: – The optimal settings and techniques for dual-extrusion ABS–PVA printing that are presented in this paper can effectively be used to explore prototyping of geometrically complex parts with PVA as support material. Originality/value: – In addition to the practical implications, the results from this work are a valuable addition to the literature related to printing using water-soluble polymers such as PVA. The experimental methods and techniques of this paper can be used to assess the reliability of similar 3D printing technologies.
- Open Access
- 23 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 3, 1
Integration of New Technology for Research in the Emergency Department: Feasibility of Deploying a Robotic Assessment Tool for Mild Traumatic Brain Injury Evaluation
The objective of this paper is to demonstrate the effective deployment of a robotic assessment tool for the evaluation of mild traumatic brain injury (mTBI) patients in a busy, resource-constrained, urban emergency department (ED). Methods: Functional integration of new robotic technology for research in the ED presented several obstacles that required a multidisciplinary approach, including participation from electrical and computer engineers, emergency medicine clinicians, and clinical operations staff of the hospital. Our team addressed many challenges in deployment of this advanced technology including: 1) adapting the investigational device for the unique clinical environment; 2) acquisition and maintenance of appropriate testing space for point-of-care assessment; and 3) dedicated technical support and upkeep of the device. Upon successful placement of the robotic device in the ED, the clinical study required screening of all patients presenting to the ED with complaints of head injury. Eligible patients were enrolled and tested using a robot-assisted test battery. Three weeks after the injury, patients were contacted to complete follow-up assessments. Results: Adapting the existing technology to meet anticipated physical constraints of the ED was performed by engineering a mobile platform. Due to the large footprint of the device, it was frequently moved before ultimately being fully integrated into the ED. Over 14 months, 1423 patients were screened. Twenty-eight patients could not be enrolled because the device was unavailable due to operations limitations. Technical problems with the device resulted in failure to include 20 patients. A total of 66 mTBI patients were enrolled and 42 of them completed both robot-assisted testing and follow-up assessment. Successful completion of screening and enrollment demonstrated that the challenges associated with integration of investigational devices into the ED can be effectively addressed through a collaborative patient-oriented research model. Conclusion: Effective deployment and use of new robotic technology for research in an urban academic ED required significant planning, coordination, and collaboration with key personnel from multiple disciplines. Clinical Impact: A pilot clinical study on mTBI patients using the robotic device provided useful data without disrupting the ED workflow. Integration of this technology into the ED serves as an important step toward pursing active clinical research in an acute care setting.
- 23 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 3, 1
Open AccessIntegration of New Technology for Research in the Emergency Department: Feasibility of Deploying a Robotic Assessment Tool for Mild Traumatic Brain Injury Evaluation
The objective of this paper is to demonstrate the effective deployment of a robotic assessment tool for the evaluation of mild traumatic brain injury (mTBI) patients in a busy, resource-constrained, urban emergency department (ED). Methods: Functional integration of new robotic technology for research in the ED presented several obstacles that required a multidisciplinary approach, including participation from electrical and computer engineers, emergency medicine clinicians, and clinical operations staff of the hospital. Our team addressed many challenges in deployment of this advanced technology including: 1) adapting the investigational device for the unique clinical environment; 2) acquisition and maintenance of appropriate testing space for point-of-care assessment; and 3) dedicated technical support and upkeep of the device. Upon successful placement of the robotic device in the ED, the clinical study required screening of all patients presenting to the ED with complaints of head injury. Eligible patients were enrolled and tested using a robot-assisted test battery. Three weeks after the injury, patients were contacted to complete follow-up assessments. Results: Adapting the existing technology to meet anticipated physical constraints of the ED was performed by engineering a mobile platform. Due to the large footprint of the device, it was frequently moved before ultimately being fully integrated into the ED. Over 14 months, 1423 patients were screened. Twenty-eight patients could not be enrolled because the device was unavailable due to operations limitations. Technical problems with the device resulted in failure to include 20 patients. A total of 66 mTBI patients were enrolled and 42 of them completed both robot-assisted testing and follow-up assessment. Successful completion of screening and enrollment demonstrated that the challenges associated with integration of investigational devices into the ED can be effectively addressed through a collaborative patient-oriented research model. Conclusion: Effective deployment and use of new robotic technology for research in an urban academic ED required significant planning, coordination, and collaboration with key personnel from multiple disciplines. Clinical Impact: A pilot clinical study on mTBI patients using the robotic device provided useful data without disrupting the ED workflow. Integration of this technology into the ED serves as an important step toward pursing active clinical research in an acute care setting.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 5768-5771
An evaluation of exhaled flow measuring mouthpieces for breath sampling devices
A study is conducted to determine the dimensions of an exhaled flow measuring mouthpiece for a breath-sampling device that requires breathing for an extended period of time. Fleisch, Pitot and Venturi type differential pressure based flow measuring mouthpieces of various dimensions are evaluated. Inner diameters (IDs) of the cylinder shaped Fleisch, Pitot and Venturi mouthpieces are varied from 5mm to 25mm. Based on the study, we conclude IDs ranging from 8.75mm to 12.5mm for Fleisch type, IDs ranging from 10mm to 12.5mm for Pitot type and ID of 10mm for Venturi type are the most suitable dimensions for a breath sampling device.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 5768-5771
An evaluation of exhaled flow measuring mouthpieces for breath sampling devices
A study is conducted to determine the dimensions of an exhaled flow measuring mouthpiece for a breath-sampling device that requires breathing for an extended period of time. Fleisch, Pitot and Venturi type differential pressure based flow measuring mouthpieces of various dimensions are evaluated. Inner diameters (IDs) of the cylinder shaped Fleisch, Pitot and Venturi mouthpieces are varied from 5mm to 25mm. Based on the study, we conclude IDs ranging from 8.75mm to 12.5mm for Fleisch type, IDs ranging from 10mm to 12.5mm for Pitot type and ID of 10mm for Venturi type are the most suitable dimensions for a breath sampling device.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 5369-5372
Alveolar air Volatile Organic Compound extractor for clinical breath sampling
Alveolar air Volatile Organic Compound (VOC) extractor is a handheld breath-sampling device for clinical breath analysis. The device consists two main components: (1) An alveolar air separator, (2) A VOC extractor. The alveolar air separator splits exhaled air based on total exhaled air volume directing alveolar air towards the VOC extractor and dead space air to into an exhaust channel. The VOC extractor collects the VOCs from alveolar air into a modified Sold Phase Micro Extraction (SPME) filament. Feasibility of using the SPME filament to collect a quantifiable breath sample directly from exhaled breath is experimentally validated. Exhaled breath acetone is quantified using alveolar air VOC extractor and a GC/MS system.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 5369-5372
Alveolar air Volatile Organic Compound extractor for clinical breath sampling
Alveolar air Volatile Organic Compound (VOC) extractor is a handheld breath-sampling device for clinical breath analysis. The device consists two main components: (1) An alveolar air separator, (2) A VOC extractor. The alveolar air separator splits exhaled air based on total exhaled air volume directing alveolar air towards the VOC extractor and dead space air to into an exhaust channel. The VOC extractor collects the VOCs from alveolar air into a modified Sold Phase Micro Extraction (SPME) filament. Feasibility of using the SPME filament to collect a quantifiable breath sample directly from exhaled breath is experimentally validated. Exhaled breath acetone is quantified using alveolar air VOC extractor and a GC/MS system.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2014 (1094687X) , 626-629
Feasibility of energy harvesting techniques for wearable medical devices
Wearable devices are arguably one of the most rapidly growing technologies in the computing and health care industry. These systems provide improved means of monitoring health status of humans in real-time. In order to cope with continuous sensing and transmission of biological and health status data, it is desirable to move towards energy autonomous systems that can charge batteries using passive, ambient energy. This not only ensures uninterrupted data capturing, but could also eliminate the need to frequently remove, replace, and recharge batteries. To this end, energy harvesting is a promising area that can lead to extremely power-efficient portable medical devices. This paper presents an experimental prototype to study the feasibility of harvesting two energy sources, solar and thermoelectric energy, in the context of wearable devices. Preliminary results show that such devices can be powered by transducing ambient energy that constantly surrounds us.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2014 (1094687X) , 626-629
Feasibility of energy harvesting techniques for wearable medical devices
Wearable devices are arguably one of the most rapidly growing technologies in the computing and health care industry. These systems provide improved means of monitoring health status of humans in real-time. In order to cope with continuous sensing and transmission of biological and health status data, it is desirable to move towards energy autonomous systems that can charge batteries using passive, ambient energy. This not only ensures uninterrupted data capturing, but could also eliminate the need to frequently remove, replace, and recharge batteries. To this end, energy harvesting is a promising area that can lead to extremely power-efficient portable medical devices. This paper presents an experimental prototype to study the feasibility of harvesting two energy sources, solar and thermoelectric energy, in the context of wearable devices. Preliminary results show that such devices can be powered by transducing ambient energy that constantly surrounds us.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2014 (1094687X) , 2161-2164
A programmable point-of-care device for external CSF drainage and monitoring
This paper presents a prototype of a programmable cerebrospinal fluid (CSF) external drainage system that can accurately measure the dispensed fluid volume. It is based on using a miniature spectrophotometer to collect color data to inform drain rate and pressure monitoring. The prototype was machined with 1 μm dimensional accuracy. The current device can reliably monitor the total accumulated fluid volume, the drain rate, the programmed pressure, and the pressure read from the sensor. Device requirements, fabrication processes, and preliminary results with an experimental set-up are also presented.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2014 (1094687X) , 2161-2164
A programmable point-of-care device for external CSF drainage and monitoring
This paper presents a prototype of a programmable cerebrospinal fluid (CSF) external drainage system that can accurately measure the dispensed fluid volume. It is based on using a miniature spectrophotometer to collect color data to inform drain rate and pressure monitoring. The prototype was machined with 1 μm dimensional accuracy. The current device can reliably monitor the total accumulated fluid volume, the drain rate, the programmed pressure, and the pressure read from the sensor. Device requirements, fabrication processes, and preliminary results with an experimental set-up are also presented.