Andrzej Mrowiec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andrzej Mrowiec has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Artur Andruszkiewicz
Wrocław University of Science and Technology
2 shared publications - Piotr Piechota
Wrocław University of Science and Technology
2 shared publications - Anna Golijanek-Jędrzejczyk
Gdansk University of Technology
1 shared publication - Dariusz Heim
Lodz University of Technology
1 shared publication - Dieter Heymann
Departments of Chemistry and Earth Science, Mails Stop 126, Rice University, Houston, TX 77251-1892, USA
1 shared publication - Elżbieta Wróblewska
Department of Thermal Science, Faculty of Mechanical and Power Engineering, Wrocław University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wrocław, Poland
1 shared publication
Latest Publications
- 22 June 2026
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Pomiary Automatyka Robotyka
- Vol. 30 (2) , 43-46
Determining the Flow Coefficient of Non-Standard Orifices and ISA Orifices
The article determined the value of the flow coefficient C for two types of orifices with the same ratio of orifice diameter to pipe diameter of 50 mm based on the results of experiments and numerical simulations. Equations were also proposed to determine the value of this coefficient in an engineering manner (with an accuracy not exceeding 1.5%) in the range of Reynolds numbers from 10,000 to 20,000.
- 22 June 2026
- Published by PIAP - Industrial Research Institute for Automation and Measurements in Pomiary Automatyka Robotyka
- Vol. 30 (2) , 43-46
Determining the Flow Coefficient of Non-Standard Orifices and ISA Orifices
The article determined the value of the flow coefficient C for two types of orifices with the same ratio of orifice diameter to pipe diameter of 50 mm based on the results of experiments and numerical simulations. Equations were also proposed to determine the value of this coefficient in an engineering manner (with an accuracy not exceeding 1.5%) in the range of Reynolds numbers from 10,000 to 20,000.
- Open Access
- 7 August 2023
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 17 (4) , 150-161
Effect of Changes in the Roughness of the Inflow Surface of a Sloping Segmental Orifice with Point Pressure Reception on Its Characteristics
The subject of this paper is the effect of changing the roughness of the inflow surface of an orifice on its characteristics. A sloping segmental orifice was chosen as the reducer and its surface roughness was changed by lining its inflow surface with sandpaper of different roughness parameters....
- 7 August 2023
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Advances in Science and Technology Research Journal
- Vol. 17 (4) , 150-161
Open AccessEffect of Changes in the Roughness of the Inflow Surface of a Sloping Segmental Orifice with Point Pressure Reception on Its Characteristics
The subject of this paper is the effect of changing the roughness of the inflow surface of an orifice on its characteristics. A sloping segmental orifice was chosen as the reducer and its surface roughness was changed by lining its inflow surface with sandpaper of different roughness parameters....
- Open Access
Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
The aim of this work is to experimentally determine and evaluate the value of the correction factor for ultrasonic flow meters in order to improve their accuracy. This article concerns flow velocity measurement with the use of an ultrasonic flow meter in the area of disturbed flow behind the distorting element. Clamp-on ultrasonic flow meters are popular among measurement technologies due to their high accuracy and easy, non-invasive installation, because the sensors are mounted directly on the outer surface of the pipe. In industrial applications, installation space is usually limited and, therefore, flow meters frequently have to be mounted directly behind flow disturbances. In such cases, it is necessary to determine the value of the correction factor. The disturbing element was a knife gate valve, a valve often used in flow installations. Water flow velocity tests were performed using an ultrasonic flow meter with clamp-on sensors on the pipeline. The research was performed in 2 series of measurements with different Reynolds numbers of 35,000 and 70,000, which correspond to a velocity of approximately 0.9 m/s and 1.8 m/s. The tests were carried out at different distances from the source of interference, within the range of 3–15 DN (pipe nominal diameter). The position of the sensors at successive measurement points on the circuit of the pipeline was changed by 30 degrees. Flow velocity measurements were carried out for two different levels of the valve’s closure: 1/3 and 1/2 of the valve’s height. For the collected velocity values at single measurement points, the values of the correction coefficient, K, were determined. The results of the tests and calculations prove that compensation error of measurement performed behind the disturbance without keeping the required straight sections of the pipeline is possible by using the factor K*. The analysis of the results made it possible to identify the optimal measuring point at a distance from the knife gate valve as being smaller than specified in the standards and recommendations.
Open AccessExperimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
The aim of this work is to experimentally determine and evaluate the value of the correction factor for ultrasonic flow meters in order to improve their accuracy. This article concerns flow velocity measurement with the use of an ultrasonic flow meter in the area of disturbed flow behind the distorting element. Clamp-on ultrasonic flow meters are popular among measurement technologies due to their high accuracy and easy, non-invasive installation, because the sensors are mounted directly on the outer surface of the pipe. In industrial applications, installation space is usually limited and, therefore, flow meters frequently have to be mounted directly behind flow disturbances. In such cases, it is necessary to determine the value of the correction factor. The disturbing element was a knife gate valve, a valve often used in flow installations. Water flow velocity tests were performed using an ultrasonic flow meter with clamp-on sensors on the pipeline. The research was performed in 2 series of measurements with different Reynolds numbers of 35,000 and 70,000, which correspond to a velocity of approximately 0.9 m/s and 1.8 m/s. The tests were carried out at different distances from the source of interference, within the range of 3–15 DN (pipe nominal diameter). The position of the sensors at successive measurement points on the circuit of the pipeline was changed by 30 degrees. Flow velocity measurements were carried out for two different levels of the valve’s closure: 1/3 and 1/2 of the valve’s height. For the collected velocity values at single measurement points, the values of the correction coefficient, K, were determined. The results of the tests and calculations prove that compensation error of measurement performed behind the disturbance without keeping the required straight sections of the pipeline is possible by using the factor K*. The analysis of the results made it possible to identify the optimal measuring point at a distance from the knife gate valve as being smaller than specified in the standards and recommendations.
- Open Access
- 28 November 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (23) , 8503
Uncertainty Assessment for Determining the Discharge Coefficient C for a Multi-Opening Orifice
This article contains the results of experimental studies of a multi-opening orifice with substitute constriction factor of β = 0.5 (m = 0.25), mounted in a DN50 hydraulic measuring flume. Flow measurements were taken from a progressing turbulent flow within Reynolds numbers (Re = 4700–19,500). Based on conducted experimental data, flow characteristics, and discharge coefficient C characteristics were determined. Relative expanded uncertainty of determining a discharge coefficient C was estimated within the changes of volume flow qv from 0.35 to 0.68 dm3/s, based on rules from the GUM international standard. The value, determined from uncertainty analysis, did not exceed 1.25% within the changes of Reynolds numbers 9800 ≤ Re ≤ 19,500.
- 28 November 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (23) , 8503
Open AccessUncertainty Assessment for Determining the Discharge Coefficient C for a Multi-Opening Orifice
This article contains the results of experimental studies of a multi-opening orifice with substitute constriction factor of β = 0.5 (m = 0.25), mounted in a DN50 hydraulic measuring flume. Flow measurements were taken from a progressing turbulent flow within Reynolds numbers (Re = 4700–19,500). Based on conducted experimental data, flow characteristics, and discharge coefficient C characteristics were determined. Relative expanded uncertainty of determining a discharge coefficient C was estimated within the changes of volume flow qv from 0.35 to 0.68 dm3/s, based on rules from the GUM international standard. The value, determined from uncertainty analysis, did not exceed 1.25% within the changes of Reynolds numbers 9800 ≤ Re ≤ 19,500.
- Open Access
- 6 November 2020
- Published by MDPI AG in Preprints.org
Uncertainty Assessment for Determining the Discharge Coefficient C for a Multi-Opening Orifice
The article contains the results of experimental studies for a multi-opening orifice with substitute constriction factor of β = 0.5 (m = 0.25), mounted in a DN50 hydraulic measuring flume. Flow measurements were taken for a progressing turbulent flow within Reynolds numbers (Re = 4700...19500). Based on experimental data, flow characteristics as well as discharge coefficient C characteristics were determined. Relative expanded uncertainty of determining a discharge coefficient C was estimated within the changes of volume flow qv from 0.35 dm3/s to 0.68 dm3/s. The value does not exceed 1.25% within the changes of Reynolds numbers 9800 ≤ Re ≤ 19500.
- 6 November 2020
- Published by MDPI AG in Preprints.org
Open AccessUncertainty Assessment for Determining the Discharge Coefficient C for a Multi-Opening Orifice
The article contains the results of experimental studies for a multi-opening orifice with substitute constriction factor of β = 0.5 (m = 0.25), mounted in a DN50 hydraulic measuring flume. Flow measurements were taken for a progressing turbulent flow within Reynolds numbers (Re = 4700...19500). Based on experimental data, flow characteristics as well as discharge coefficient C characteristics were determined. Relative expanded uncertainty of determining a discharge coefficient C was estimated within the changes of volume flow qv from 0.35 dm3/s to 0.68 dm3/s. The value does not exceed 1.25% within the changes of Reynolds numbers 9800 ≤ Re ≤ 19500.
- 1 March 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 30 (3)
Influence of Tylose MH1000 Content on Gypsum Thermal Conductivity
The presented work focuses on the influence of a water-soluble derivative of cellulose, hydroxyethyl methyl cellulose (HEMC), on gypsum thermal properties. The polymer is used as an additive in the weight fraction, up to 1% of pure gypsum. The water-to-gypsum ratio was taken at a level of 0.74. The study of hemihydrate calcium sulphate hydration of crystalline form was observed using own-made apparatus measuring the temperature of the system during hydration. The presence of the polymer leads to a retardation of the hydration and setting process of gypsum paste. For the purpose of conductivity measurements, an improved method with a “hot wire” setup was used. A decrease of thermal conductivity and density with added HEMC was observed because of structure modifications of the gypsum product. It was concluded that adding HEMC influences not only the water retention coefficient and the rate of setting of gypsum, it also changes the morphological structure of gypsum-polymer composite, which is reflected in the density and thermal conductivity of the final product.- 1 March 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Materials in Civil Engineering
- Vol. 30 (3)
Influence of Tylose MH1000 Content on Gypsum Thermal Conductivity
The presented work focuses on the influence of a water-soluble derivative of cellulose, hydroxyethyl methyl cellulose (HEMC), on gypsum thermal properties. The polymer is used as an additive in the weight fraction, up to 1% of pure gypsum. The water-to-gypsum ratio was taken at a level of 0.74. The study of hemihydrate calcium sulphate hydration of crystalline form was observed using own-made apparatus measuring the temperature of the system during hydration. The presence of the polymer leads to a retardation of the hydration and setting process of gypsum paste. For the purpose of conductivity measurements, an improved method with a “hot wire” setup was used. A decrease of thermal conductivity and density with added HEMC was observed because of structure modifications of the gypsum product. It was concluded that adding HEMC influences not only the water retention coefficient and the rate of setting of gypsum, it also changes the morphological structure of gypsum-polymer composite, which is reflected in the density and thermal conductivity of the final product.- Open Access
- 1 October 2002
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 37 (10) , 1391-1399
Microscopic search for the carrier phase Q of the trapped planetary noble gases in Allende, Leoville and Vigarano
- 1 October 2002
- Published by Wiley in Meteoritics & Planetary Science
- Vol. 37 (10) , 1391-1399
Open AccessMicroscopic search for the carrier phase Q of the trapped planetary noble gases in Allende, Leoville and Vigarano