On Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
On Kim has a total of 253 co-authors. Here are the top co-authors by number of shared publications:
- Yannis K. Semertzidis
KAIST
5 shared publications - Bingzhi Li
Zhejiang Lab
4 shared publications - Ce Zhang
University of Liverpool
4 shared publications - Liang Li
Shanghai Jiao Tong University
4 shared publications - Saskia Charity
University of Liverpool
4 shared publications - Selcuk Haciomeroglu
Center for Axion and Precision Physics Research, IBS, Daejeon 34051, Republic of Korea
4 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11) , 1292
Canton-$\mu $ proposal: a next-generation muon $g\!-\!2$ measurement at sub-0.1 ppm precisionWe propose a next-generation precision measurement of the muon anomalous magnetic moment (muon $$g\!-\!2$$ ) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON- $$\mu $$ ( Coherent Anomalous magNetic momenT ObservatioN with muon ). HIAF’s intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the $$0.05~\textrm{ppm}$$ level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the $$10^{-24}\ \textrm{GeV}$$ level, an order of magnitude beyond current limits.- 9 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11) , 1292
Open AccessCanton-$\mu $ proposal: a next-generation muon $g\!-\!2$ measurement at sub-0.1 ppm precisionWe propose a next-generation precision measurement of the muon anomalous magnetic moment (muon $$g\!-\!2$$ ) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON- $$\mu $$ ( Coherent Anomalous magNetic momenT ObservatioN with muon ). HIAF’s intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the $$0.05~\textrm{ppm}$$ level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the $$10^{-24}\ \textrm{GeV}$$ level, an order of magnitude beyond current limits. - Open Access
Cavity, Lumped Circuit, and Spin-Based Detection of Axion Dark Matter: Differences and Similarities
Axions and axion-like particles are compelling candidates for ultralight bosonic dark matter, forming coherent oscillating fields that can be probed by experiments known as haloscopes. A broad range of haloscope concepts has been developed, including resonant cavity haloscopes, lumped-element circuit detectors, and spin-based experiments, each sensitive to different axion couplings and mass ranges. Rather than attempting an exhaustive survey of all existing approaches, this comparative review provides a unified framework for the major haloscope classes, establishing a common language for the descriptions of signal generation, noise properties, analytical methodologies, and scanning strategies. Key properties of ultralight bosonic dark matter relevant for detection are summarized first, including coherence time, spectral linewidth, and stochasticity under the standard halo model. The discussion then compares cavity, Earth-scale, lumped-element, and spin haloscopes, focusing on expected signal shapes, dominant noise sources, and statistical frameworks for axion searches. Particular emphasis is placed on consistent definitions of signal-to-noise ratio and on how detector bandwidth, axion coherence, and noise characteristics determine optimal scan strategies. By systematically comparing operating principles and performance metrics across these detector families, this framework clarifies shared concepts as well as the essential differences that govern sensitivity in different mass and coupling regimes. The resulting perspective synthesizes current search methodologies and offers guidance for optimizing future haloscope experiments.
Open AccessCavity, Lumped Circuit, and Spin-Based Detection of Axion Dark Matter: Differences and Similarities
Axions and axion-like particles are compelling candidates for ultralight bosonic dark matter, forming coherent oscillating fields that can be probed by experiments known as haloscopes. A broad range of haloscope concepts has been developed, including resonant cavity haloscopes, lumped-element circuit detectors, and spin-based experiments, each sensitive to different axion couplings and mass ranges. Rather than attempting an exhaustive survey of all existing approaches, this comparative review provides a unified framework for the major haloscope classes, establishing a common language for the descriptions of signal generation, noise properties, analytical methodologies, and scanning strategies. Key properties of ultralight bosonic dark matter relevant for detection are summarized first, including coherence time, spectral linewidth, and stochasticity under the standard halo model. The discussion then compares cavity, Earth-scale, lumped-element, and spin haloscopes, focusing on expected signal shapes, dominant noise sources, and statistical frameworks for axion searches. Particular emphasis is placed on consistent definitions of signal-to-noise ratio and on how detector bandwidth, axion coherence, and noise characteristics determine optimal scan strategies. By systematically comparing operating principles and performance metrics across these detector families, this framework clarifies shared concepts as well as the essential differences that govern sensitivity in different mass and coupling regimes. The resulting perspective synthesizes current search methodologies and offers guidance for optimizing future haloscope experiments.
- Top Cited PapersOpen Access
- 9 July 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (10) , 101802
Measurement of the positive muon anomalous magnetic moment to 127 ppb
A new measurement of the magnetic anomaly a μ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon g − 2 Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine a μ = 1 165 920 710 ( 162 ) × 10 − 12 (139 ppb) for the new datasets, and a μ = 1 165 920 705 ( 148 ) × 10 − 12 (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is a μ ( exp ) = 1 165 920 715 ( 145 ) × 10 − 12 (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of 4.
- 9 July 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (10) , 101802
Top Cited PapersOpen AccessMeasurement of the positive muon anomalous magnetic moment to 127 ppb
A new measurement of the magnetic anomaly a μ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon g − 2 Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine a μ = 1 165 920 710 ( 162 ) × 10 − 12 (139 ppb) for the new datasets, and a μ = 1 165 920 705 ( 148 ) × 10 − 12 (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is a μ ( exp ) = 1 165 920 715 ( 145 ) × 10 − 12 (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of 4.
- Top Cited PapersOpen Access
- 8 August 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (3) , 032009
Detailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm
We present details on a new measurement of the muon magnetic anomaly, . The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is (0.19 ppm).- 8 August 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (3) , 032009
Top Cited PapersOpen AccessDetailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm
We present details on a new measurement of the muon magnetic anomaly, . The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is (0.19 ppm). - Top Cited PapersOpen Access
- 17 October 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (16) , 161802
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
We present a new measurement of the positive muon magnetic anomaly, , from the Fermilab Muon Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, , and of the anomalous precession frequency corrected for beam dynamics effects, . From the ratio , together with precisely determined external parameters, we determine (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain (0.20 ppm). The new experimental world average is (0.19 ppm), which represents a factor of 2 improvement in precision.- 17 October 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (16) , 161802
Top Cited PapersOpen AccessMeasurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
We present a new measurement of the positive muon magnetic anomaly, , from the Fermilab Muon Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, , and of the anomalous precession frequency corrected for beam dynamics effects, . From the ratio , together with precisely determined external parameters, we determine (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain (0.20 ppm). The new experimental world average is (0.19 ppm), which represents a factor of 2 improvement in precision. - Open Access
- 14 July 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (1) , 015017
Searching for axion forces with precision precession in storage rings
We consider different types of storage rings as precision probes of axion-mediated monopole-dipole forces. We show that current and planned experiments aiming to measure magnetic and electric dipole moments of protons, muons. and electrons very precisely may explore new parts of the parameter space beyond existing laboratory bounds and, in some cases, beyond astrophysical constraints. Remarkably, a light axion coupled to muons may explain the FNAL/BNL anomaly as an environmental effect—the coherent axion field generated by the earth nucleons induces an extra contribution to the anomalous precession frequency of the muon explaining the discrepancy with respect to the SM prediction.- 14 July 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 108 (1) , 015017
Open AccessSearching for axion forces with precision precession in storage rings
We consider different types of storage rings as precision probes of axion-mediated monopole-dipole forces. We show that current and planned experiments aiming to measure magnetic and electric dipole moments of protons, muons. and electrons very precisely may explore new parts of the parameter space beyond existing laboratory bounds and, in some cases, beyond astrophysical constraints. Remarkably, a light axion coupled to muons may explain the FNAL/BNL anomaly as an environmental effect—the coherent axion field generated by the earth nucleons induces an extra contribution to the anomalous precession frequency of the muon explaining the discrepancy with respect to the SM prediction. - Open Access
Analytical Estimations of the Chromaticity and Corrections to the Spin Precession Frequency in Weak Focusing Magnetic Storage Rings
Understanding beam and spin dynamics are fundamental in accelerator physics, and there has been growing interest in having more precise estimations of the beam and spin dynamics variables, as more high precision particle physics experiments in the Intensity Frontier appear. The present paper provides analytical estimations of some of the important variables such as beam transverse chromaticities and the spin precession frequency bias in the simplest type of particle accelerator: a circular magnetic storage ring with weak vertical focusing. We attempt to precisely obtain the next order approximations from the small betatron oscillations or the momentum dispersion, verified by high precision spin tracking simulation. We also discuss a potential way to suppress the spin precession frequency bias which relevant experiments may find beneficial.
Open AccessAnalytical Estimations of the Chromaticity and Corrections to the Spin Precession Frequency in Weak Focusing Magnetic Storage Rings
Understanding beam and spin dynamics are fundamental in accelerator physics, and there has been growing interest in having more precise estimations of the beam and spin dynamics variables, as more high precision particle physics experiments in the Intensity Frontier appear. The present paper provides analytical estimations of some of the important variables such as beam transverse chromaticities and the spin precession frequency bias in the simplest type of particle accelerator: a circular magnetic storage ring with weak vertical focusing. We attempt to precisely obtain the next order approximations from the small betatron oscillations or the momentum dispersion, verified by high precision spin tracking simulation. We also discuss a potential way to suppress the spin precession frequency bias which relevant experiments may find beneficial.
- Open Access
- 18 February 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (2) , 024001
Analytical estimations of the chromaticity and corrections to the spin precession frequency in weak focusing magnetic storage rings
Understanding beam and spin dynamics are fundamental in accelerator-based experiments concerning polarized beams. And there has been growing interest in having more precise estimations of the beam and spin dynamics variables, as more high precision particle physics experiments in the intensity frontier appear. This paper provides analytical estimations of some of the important variables such as beam transverse chromaticities and corrections to the spin precession frequency in the simplest type of particle accelerator: a circular magnetic storage ring with weak vertical focusing. We attempt to precisely obtain the next order approximations from the small betatron oscillations or the momentum dispersion, verified by high precision spin tracking simulation. We also discuss a potential way to suppress the corrections to the spin precession frequency, which relevant experiments may find beneficial.
- 18 February 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (2) , 024001
Open AccessAnalytical estimations of the chromaticity and corrections to the spin precession frequency in weak focusing magnetic storage rings
Understanding beam and spin dynamics are fundamental in accelerator-based experiments concerning polarized beams. And there has been growing interest in having more precise estimations of the beam and spin dynamics variables, as more high precision particle physics experiments in the intensity frontier appear. This paper provides analytical estimations of some of the important variables such as beam transverse chromaticities and corrections to the spin precession frequency in the simplest type of particle accelerator: a circular magnetic storage ring with weak vertical focusing. We attempt to precisely obtain the next order approximations from the small betatron oscillations or the momentum dispersion, verified by high precision spin tracking simulation. We also discuss a potential way to suppress the corrections to the spin precession frequency, which relevant experiments may find beneficial.
- Open Access
New method of probing an oscillating EDM induced by axionlike dark matter using an RF Wien Filter in storage rings
A hypothetical pseudo-scalar particle axion, which is an immediate result of the Peccei-Quinn solution to the strong CP problem, may couple to gluons and lead to an oscillating electric dipole moment (EDM) of fundamental particles. This paper proposes a novel method of probing the axion-induced oscillating EDM in storage rings, using a radiofrequency (RF) Wien Filter. The Wien Filter at the frequency of the sidebands of the axion and $g-2$ frequency, $f_\text{axion} \pm f_{g-2}$, generates a spin resonance in the presence of an oscillating EDM, as confirmed both by an analytical estimation of the spin equations and independently by simulation. A brief systematic study also shows that this method is unlikely to be limited by Wien Filter misalignment issues.Open AccessNew method of probing an oscillating EDM induced by axionlike dark matter using an RF Wien Filter in storage rings
A hypothetical pseudo-scalar particle axion, which is an immediate result of the Peccei-Quinn solution to the strong CP problem, may couple to gluons and lead to an oscillating electric dipole moment (EDM) of fundamental particles. This paper proposes a novel method of probing the axion-induced oscillating EDM in storage rings, using a radiofrequency (RF) Wien Filter. The Wien Filter at the frequency of the sidebands of the axion and $g-2$ frequency, $f_\text{axion} \pm f_{g-2}$, generates a spin resonance in the presence of an oscillating EDM, as confirmed both by an analytical estimation of the spin equations and independently by simulation. A brief systematic study also shows that this method is unlikely to be limited by Wien Filter misalignment issues. - Open Access
- 9 November 2021
- Published by American Physical Society (APS) in Physical Review D
- Vol. 104 (9) , 096006
New method of probing an oscillating EDM induced by axionlike dark matter using an rf Wien filter in storage rings
A hypothetical pseudoscalar particle axion, which is an immediate result of the Peccei-Quinn solution to the strong problem, may couple to gluons and lead to an oscillating electric dipole moment (EDM) of fundamental particles. This paper proposes a novel method of probing the axion-induced oscillating EDM in storage rings, using a radio frequency (rf) Wien filter. The Wien filter at the frequency of the sidebands of the axion and frequency, , generates a spin resonance in the presence of an oscillating EDM, as confirmed both by an analytical estimation of the spin equations and independently by simulation. A brief systematic study also shows that this method is unlikely to be limited by Wien filter misalignment issues.- 9 November 2021
- Published by American Physical Society (APS) in Physical Review D
- Vol. 104 (9) , 096006
Open AccessNew method of probing an oscillating EDM induced by axionlike dark matter using an rf Wien filter in storage rings
A hypothetical pseudoscalar particle axion, which is an immediate result of the Peccei-Quinn solution to the strong problem, may couple to gluons and lead to an oscillating electric dipole moment (EDM) of fundamental particles. This paper proposes a novel method of probing the axion-induced oscillating EDM in storage rings, using a radio frequency (rf) Wien filter. The Wien filter at the frequency of the sidebands of the axion and frequency, , generates a spin resonance in the presence of an oscillating EDM, as confirmed both by an analytical estimation of the spin equations and independently by simulation. A brief systematic study also shows that this method is unlikely to be limited by Wien filter misalignment issues.