Bingzhi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Bingzhi Li has a total of 232 co-authors. Here are the top co-authors by number of shared publications:
- Liang Li
Shanghai Jiao Tong University
5 shared publications - Ce Zhang
University of Liverpool
4 shared publications - On Kim
University of Washington
4 shared publications - Saskia Charity
University of Liverpool
4 shared publications - Zejia Lu
Shanghai Jiao Tong University
4 shared publications - A. Chapelain
Cornell University
3 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11) , 1292
Canton-$\mu $ proposal: a next-generation muon $g\!-\!2$ measurement at sub-0.1 ppm precisionWe propose a next-generation precision measurement of the muon anomalous magnetic moment (muon $$g\!-\!2$$ ) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON- $$\mu $$ ( Coherent Anomalous magNetic momenT ObservatioN with muon ). HIAF’s intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the $$0.05~\textrm{ppm}$$ level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the $$10^{-24}\ \textrm{GeV}$$ level, an order of magnitude beyond current limits.- 9 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11) , 1292
Open AccessCanton-$\mu $ proposal: a next-generation muon $g\!-\!2$ measurement at sub-0.1 ppm precisionWe propose a next-generation precision measurement of the muon anomalous magnetic moment (muon $$g\!-\!2$$ ) at the High Intensity Heavy-Ion Accelerator Facility (HIAF) in Huizhou, China. We refer to this proposed experimental programme as CANTON- $$\mu $$ ( Coherent Anomalous magNetic momenT ObservatioN with muon ). HIAF’s intense, pulsed GeV-scale muon beams, particularly for negative muons, provide a promising basis for this programme. Building on two previously proposed storage-ring concepts, this work develops HIAF-specific experimental schemes that relax the conventional magic-momentum constraint and allow greater flexibility in the choice of beam momentum. We assess the expected muon intensity at HIAF and the corresponding statistical sensitivity. For each scheme, we identify its distinctive systematic effects, examine feasible control strategies, and propose quantitative systematic-uncertainty targets. Together, the statistical projections and systematic-uncertainty targets indicate prospective total precisions of 0.1 ppm in Phase-I, comparable to the current Fermilab precision, with the potential to reach the $$0.05~\textrm{ppm}$$ level in Phase-II following the planned HIAF upgrade. At the ultimate projected precision, the measurement would provide a stringent test of the Standard Model and probe new physics at multi-TeV scales. A focus on negative-muon measurements would enable direct comparison with existing high-precision positive-muon results and strengthen tests of CPT symmetry in the muon sector within the Standard-Model Extension, with a projected sensitivity at the $$10^{-24}\ \textrm{GeV}$$ level, an order of magnitude beyond current limits. - Open Access
- 13 February 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (7) , eaeb9234
Nanoscale temperature mapping through thermal vibration characterization using scanning precession electron diffraction
Accurate temperature measurement with a high spatial resolution is essential for understanding thermal behavior in integrated nanoscale devices and especially at heterogeneous interfaces. However, existing techniques are often limited by insufficient spatial resolution. Here, we showcase the direct and noncontact temperature measurement with a nanometer spatial resolution using transmission electron microscopy. The experimental probe is the combination of a scanning nanobeam with precession electron diffraction, which offers the collection of kinematic diffraction intensity from a local area at the nanometer scale. With a precalculated, sample- and geometry-specific structure factor–based correction, the linear fitting of diffraction intensities allows the determination of the Debye-Waller factor and, thus, temperature with a precision of 10 −4 square angstrom per °C. Using graphene as a model material, this work reveals the influence of sample tilt, lattice thermal expansion, and sample thickness on Debye-Waller factor and offers a route to improving the measurement precision along with spatial resolution. The approach establishes a broadly applicable strategy for nanoscale thermometry in low-dimensional and heterogeneous materials.
- 13 February 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (7) , eaeb9234
Open AccessNanoscale temperature mapping through thermal vibration characterization using scanning precession electron diffraction
Accurate temperature measurement with a high spatial resolution is essential for understanding thermal behavior in integrated nanoscale devices and especially at heterogeneous interfaces. However, existing techniques are often limited by insufficient spatial resolution. Here, we showcase the direct and noncontact temperature measurement with a nanometer spatial resolution using transmission electron microscopy. The experimental probe is the combination of a scanning nanobeam with precession electron diffraction, which offers the collection of kinematic diffraction intensity from a local area at the nanometer scale. With a precalculated, sample- and geometry-specific structure factor–based correction, the linear fitting of diffraction intensities allows the determination of the Debye-Waller factor and, thus, temperature with a precision of 10 −4 square angstrom per °C. Using graphene as a model material, this work reveals the influence of sample tilt, lattice thermal expansion, and sample thickness on Debye-Waller factor and offers a route to improving the measurement precision along with spatial resolution. The approach establishes a broadly applicable strategy for nanoscale thermometry in low-dimensional and heterogeneous materials.
- Top Cited PapersOpen Access
- 9 July 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (10) , 101802
Measurement of the positive muon anomalous magnetic moment to 127 ppb
A new measurement of the magnetic anomaly a μ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon g − 2 Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine a μ = 1 165 920 710 ( 162 ) × 10 − 12 (139 ppb) for the new datasets, and a μ = 1 165 920 705 ( 148 ) × 10 − 12 (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is a μ ( exp ) = 1 165 920 715 ( 145 ) × 10 − 12 (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of 4.
- 9 July 2025
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 135 (10) , 101802
Top Cited PapersOpen AccessMeasurement of the positive muon anomalous magnetic moment to 127 ppb
A new measurement of the magnetic anomaly a μ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon g − 2 Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine a μ = 1 165 920 710 ( 162 ) × 10 − 12 (139 ppb) for the new datasets, and a μ = 1 165 920 705 ( 148 ) × 10 − 12 (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is a μ ( exp ) = 1 165 920 715 ( 145 ) × 10 − 12 (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of 4.
- Top Cited PapersOpen Access
- 8 August 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (3) , 032009
Detailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm
We present details on a new measurement of the muon magnetic anomaly, . The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is (0.19 ppm).- 8 August 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (3) , 032009
Top Cited PapersOpen AccessDetailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm
We present details on a new measurement of the muon magnetic anomaly, . The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is (0.19 ppm). - 24 May 2024
- Published by Elsevier in Nuclear and Particle Physics Proceedings
- Vol. 345, 18-21
Deep learning based tracking reconstruction and magnetic field measurement research in the muon g-2 experiment
- 24 May 2024
- Published by Elsevier in Nuclear and Particle Physics Proceedings
- Vol. 345, 18-21
Deep learning based tracking reconstruction and magnetic field measurement research in the muon g-2 experiment
- Top Cited PapersOpen Access
- 17 October 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (16) , 161802
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
We present a new measurement of the positive muon magnetic anomaly, , from the Fermilab Muon Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, , and of the anomalous precession frequency corrected for beam dynamics effects, . From the ratio , together with precisely determined external parameters, we determine (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain (0.20 ppm). The new experimental world average is (0.19 ppm), which represents a factor of 2 improvement in precision.- 17 October 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (16) , 161802
Top Cited PapersOpen AccessMeasurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
We present a new measurement of the positive muon magnetic anomaly, , from the Fermilab Muon Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, , and of the anomalous precession frequency corrected for beam dynamics effects, . From the ratio , together with precisely determined external parameters, we determine (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain (0.20 ppm). The new experimental world average is (0.19 ppm), which represents a factor of 2 improvement in precision.