Akihiko Kato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akihiko Kato has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Satoru Kato
Toyota Central Research and Development Laboratories (Japan)
13 shared publications - Satoshi Yamaguchi
Toyota Central R&D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192, Japan
10 shared publications - Wataru Yoshimune
Toyota Central R&D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192, Japan
8 shared publications - Takahisa Suzuki
Toyota Central R&D Labs., Inc
5 shared publications - Yasutaka Nagai
Toyota Central R&D Labs., Inc., Nagakute, Japan
5 shared publications Satoshi Yamaguchi
4 shared publications
Latest Publications
- Open Access
- 4 May 2026
- Published by Elsevier in SSRN Electronic Journal
Liquid Water Transport by Cross-Flow in Polymer Electrolyte Fuel Cells Evaluated by Time-Resolved Operando X-ray Computed Tomography
Cross-flow in polymer electrolyte fuel cells (PEFCs) enhances oxygen transport and suppresses liquid water accumulation in gas diffusion layers (GDLs); however, the existence of liquid-phase transport induced by cross-flow has not been experimentally verified. In this study, operando synchrotron X-ray computed tomography (CT) with an effective temporal resolution of 4 s was employed to visualize the three-dimensional liquid water distribution in a specially designed cell that induces cross-flow. After increasing the cathode flow rate, the liquid water in the cathode GDL decreased predominantly on the cross-flow inlet side, whereas liquid emerging in the outlet channel remained continuously connected to the water in the GDL. A cluster connectivity analysis revealed that the water cluster volume remained at 96% before and after liquid emergence in the channel. Experimental evidence suggests, for the first time, that liquid water transport is driven by cross-flow. The transient liquid transport rate was estimated to be of the same order of magnitude as the water production rate from the oxygen reduction reaction (ORR), indicating that liquid transport plays a major role in water removal from the GDL. These findings offer mechanistic insights into water redistribution induced by cross-flow.
- 4 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessLiquid Water Transport by Cross-Flow in Polymer Electrolyte Fuel Cells Evaluated by Time-Resolved Operando X-ray Computed Tomography
Cross-flow in polymer electrolyte fuel cells (PEFCs) enhances oxygen transport and suppresses liquid water accumulation in gas diffusion layers (GDLs); however, the existence of liquid-phase transport induced by cross-flow has not been experimentally verified. In this study, operando synchrotron X-ray computed tomography (CT) with an effective temporal resolution of 4 s was employed to visualize the three-dimensional liquid water distribution in a specially designed cell that induces cross-flow. After increasing the cathode flow rate, the liquid water in the cathode GDL decreased predominantly on the cross-flow inlet side, whereas liquid emerging in the outlet channel remained continuously connected to the water in the GDL. A cluster connectivity analysis revealed that the water cluster volume remained at 96% before and after liquid emergence in the channel. Experimental evidence suggests, for the first time, that liquid water transport is driven by cross-flow. The transient liquid transport rate was estimated to be of the same order of magnitude as the water production rate from the oxygen reduction reaction (ORR), indicating that liquid transport plays a major role in water removal from the GDL. These findings offer mechanistic insights into water redistribution induced by cross-flow.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (41) , 2068
Gas Purge for Water Evaporation in a Gas Diffusion Layer for Polymer Electrolyte Fuel Cells
Fuel cell electric vehicles (FCEVs) employ a gas purging process during shutdown to minimize the presence of residual water within the fuel cell stack. If not properly removed, residual water can freeze under subzero conditions, leading to cold start failure and potential damage to cell components [1]. Ice accumulation in the membrane electrode assembly (MEA) obstructs air flow to the cathode, which can hinder safe cold starts, while repeated freeze/thaw cycles may permanently deform electrode materials [2]. Gas purging eliminates water slugs in the flow field channels, dries out the gas diffusion layer (GDL), and eventually dehydrates the perfluorosulfonic (PFSA) ionomer in the catalyst layer (CL) and the proton exchange membrane (PEM). For reliable cold starts, it is essential to retain adequate hydration within the PEM while ensuring that excess water is removed from the GDL pores and flow field channels. To meet customer demands, the entire purging process must typically be completed in under 60 seconds [1]. Although higher temperatures, higher flow rates, and longer purge durations can enhance water evaporation, they also raise energy consumption. Previous studies have explored various strategies to optimize purging efficiency. Kocher et al. examined how purge duration affects cold start performance [3]. St-Pierre et al. emphasized that dry gas purging should be performed above freezing but below normal operating temperatures [4]. Sinha and Wang developed a model to predict purging behavior by analyzing water transport in the cathode GDL [5]. The residual water in the flow field channels and PEM dehydration have been studied by optical imaging [6] and high-frequency resistance (HFR) monitoring [7], respectively. However, limited attention has been given to water evaporation within GDL pores. Based on our prior work using operando synchrotron X-ray imaging to visualize water distribution in polymer electrolyte fuel cells [8,9], we recognize that accumulated water in the GDL requires extended purging to fully evaporate. In this work, we performed a series of purge tests to gain a deeper understanding of water evaporation using operando synchrotron X-ray radiography, as well as using simultaneous HFR monitoring. References [1] A. A. Amamou, S. Kelouwani, L. Boulon, and K. Agbossou, IEEE Access 4 (2016) 4989–5002. [2] J. Liang, L. Fan, Q. Du, Y. Yin, and K. Jiao, Adv. Sci. 10 (2023) 2302151. [3] K. Kocher, S. Kolar, W. Ladreiter, and V. Hacker, Fuel Cells 21 (2021) 363–372. [4] J. St-Pierre, J. Roberts, K. Colbow, S. Campbell, and A. Nelson, J. New Mater. Electrochem. Syst. 8 (2005) 163–176. [5] P. K. Sinha and C.-Y. Wang, J. Electrochem. Soc. 154 (2007) B1158–B1166. [6] Y. Ishikawa, H. Hamada, M. Uehara, and M. Shiozawa, J. Power Sources 179 (2008) 547–552. [7] K. Tajiri, C.-Y. Wang, and Y. Tabuchi, Electrochim. Acta 53 (2008) 6337–6343. [8] W. Yoshimune, Y. Higuchi, A. Kato, S. Hibi, S. Yamaguchi, Y. Matsumoto, H. Hayashida, H. Nozaki, T. Shinohara, and S. Kato, ACS Energy Lett. 8 (2023) 3485–3487. [9] W. Yoshimune, Y. Higuchi, F. Song, S. Hibi, Y. Matsumoto, H. Hayashida, H. Nozaki, T. Shinohara, and S. Kato, Phys. Chem. Chem. Phys. 26 (2024) 29466–29474.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (41) , 2068
Gas Purge for Water Evaporation in a Gas Diffusion Layer for Polymer Electrolyte Fuel Cells
Fuel cell electric vehicles (FCEVs) employ a gas purging process during shutdown to minimize the presence of residual water within the fuel cell stack. If not properly removed, residual water can freeze under subzero conditions, leading to cold start failure and potential damage to cell components [1]. Ice accumulation in the membrane electrode assembly (MEA) obstructs air flow to the cathode, which can hinder safe cold starts, while repeated freeze/thaw cycles may permanently deform electrode materials [2]. Gas purging eliminates water slugs in the flow field channels, dries out the gas diffusion layer (GDL), and eventually dehydrates the perfluorosulfonic (PFSA) ionomer in the catalyst layer (CL) and the proton exchange membrane (PEM). For reliable cold starts, it is essential to retain adequate hydration within the PEM while ensuring that excess water is removed from the GDL pores and flow field channels. To meet customer demands, the entire purging process must typically be completed in under 60 seconds [1]. Although higher temperatures, higher flow rates, and longer purge durations can enhance water evaporation, they also raise energy consumption. Previous studies have explored various strategies to optimize purging efficiency. Kocher et al. examined how purge duration affects cold start performance [3]. St-Pierre et al. emphasized that dry gas purging should be performed above freezing but below normal operating temperatures [4]. Sinha and Wang developed a model to predict purging behavior by analyzing water transport in the cathode GDL [5]. The residual water in the flow field channels and PEM dehydration have been studied by optical imaging [6] and high-frequency resistance (HFR) monitoring [7], respectively. However, limited attention has been given to water evaporation within GDL pores. Based on our prior work using operando synchrotron X-ray imaging to visualize water distribution in polymer electrolyte fuel cells [8,9], we recognize that accumulated water in the GDL requires extended purging to fully evaporate. In this work, we performed a series of purge tests to gain a deeper understanding of water evaporation using operando synchrotron X-ray radiography, as well as using simultaneous HFR monitoring. References [1] A. A. Amamou, S. Kelouwani, L. Boulon, and K. Agbossou, IEEE Access 4 (2016) 4989–5002. [2] J. Liang, L. Fan, Q. Du, Y. Yin, and K. Jiao, Adv. Sci. 10 (2023) 2302151. [3] K. Kocher, S. Kolar, W. Ladreiter, and V. Hacker, Fuel Cells 21 (2021) 363–372. [4] J. St-Pierre, J. Roberts, K. Colbow, S. Campbell, and A. Nelson, J. New Mater. Electrochem. Syst. 8 (2005) 163–176. [5] P. K. Sinha and C.-Y. Wang, J. Electrochem. Soc. 154 (2007) B1158–B1166. [6] Y. Ishikawa, H. Hamada, M. Uehara, and M. Shiozawa, J. Power Sources 179 (2008) 547–552. [7] K. Tajiri, C.-Y. Wang, and Y. Tabuchi, Electrochim. Acta 53 (2008) 6337–6343. [8] W. Yoshimune, Y. Higuchi, A. Kato, S. Hibi, S. Yamaguchi, Y. Matsumoto, H. Hayashida, H. Nozaki, T. Shinohara, and S. Kato, ACS Energy Lett. 8 (2023) 3485–3487. [9] W. Yoshimune, Y. Higuchi, F. Song, S. Hibi, Y. Matsumoto, H. Hayashida, H. Nozaki, T. Shinohara, and S. Kato, Phys. Chem. Chem. Phys. 26 (2024) 29466–29474.
- 21 July 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 655
In situ observation of water evaporation in gas diffusion layers of polymer electrolyte fuel cells
- 21 July 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 655
In situ observation of water evaporation in gas diffusion layers of polymer electrolyte fuel cells
- Open Access
- 25 May 2025
- Published by American Chemical Society (ACS) in ChemRxiv
In situ observation of water evaporation in gas diffusion layers of polymer electrolyte fuel cells
During the shutdown processes of polymer electrolyte fuel cells (PEFCs) used in fuel cell electric vehicles, effective gas purging is essential to minimize residual water within the fuel cells and ensure safe cold starts under subzero temperatures. High-frequency resistance (HFR) measurements are commonly used to confirm the completion of the gas purging process; however, these measurements reflect only the water content in the proton exchange membrane (PEM) and overlook water accumulation in the gas diffusion layer (GDL). In this study, we employed in situ synchrotron X-ray radiography with HFR monitoring to investigate the effects of the gas flow rate and purging duration on the water evaporation behavior within the cathode GDL. The results indicated that the water accumulation in the under-rib region of the cathode GDL was evaporation resistant, even with high-flow-rate gas purging. Quantitative analysis revealed that evaporation proceeded mainly via vapor-phase diffusive transport, with convective transport playing a minor role. Importantly, water slugs remained in the flow channels acted as diffusion barriers, limiting vapor transport. Immediately after purging, residual water migrated from the GDL to the PEM, contributing to HFR relaxation. These insights support the development of more effective purging protocols to ensure reliable cold starts in PEFC systems.
- 25 May 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessIn situ observation of water evaporation in gas diffusion layers of polymer electrolyte fuel cells
During the shutdown processes of polymer electrolyte fuel cells (PEFCs) used in fuel cell electric vehicles, effective gas purging is essential to minimize residual water within the fuel cells and ensure safe cold starts under subzero temperatures. High-frequency resistance (HFR) measurements are commonly used to confirm the completion of the gas purging process; however, these measurements reflect only the water content in the proton exchange membrane (PEM) and overlook water accumulation in the gas diffusion layer (GDL). In this study, we employed in situ synchrotron X-ray radiography with HFR monitoring to investigate the effects of the gas flow rate and purging duration on the water evaporation behavior within the cathode GDL. The results indicated that the water accumulation in the under-rib region of the cathode GDL was evaporation resistant, even with high-flow-rate gas purging. Quantitative analysis revealed that evaporation proceeded mainly via vapor-phase diffusive transport, with convective transport playing a minor role. Importantly, water slugs remained in the flow channels acted as diffusion barriers, limiting vapor transport. Immediately after purging, residual water migrated from the GDL to the PEM, contributing to HFR relaxation. These insights support the development of more effective purging protocols to ensure reliable cold starts in PEFC systems.
- Open Access
- 19 May 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Effect of through-plane temperature gradient on water distribution in the anode gas diffusion layer for polymer electrolyte fuel cells
Temperature gradients across the catalyst-coated membrane influence water accumulation in the anode gas diffusion layer (GDL) of polymer electrolyte fuel cells, yet experimental investigations remain limited. This study systematically examines the impact of a through-plane temperature gradient on water distribution using operando synchrotron X-ray radiography. Lowering the anode temperature relative to the cathode causes increased water saturation in the anode GDL. This behavior is mainly due to phase-transition effects, specifically enhanced condensation and suppressed evaporation. A water saturation of 0.168 is observed in the under-rib regions of the anode GDL, which is relatively high compared to commonly reported values. These findings support the growing recognition that anode water accumulation can occur under certain temperature gradients, highlighting the crucial role of temperature gradients and the need for improved anode GDL designs in effective water management.
- 19 May 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessEffect of through-plane temperature gradient on water distribution in the anode gas diffusion layer for polymer electrolyte fuel cells
Temperature gradients across the catalyst-coated membrane influence water accumulation in the anode gas diffusion layer (GDL) of polymer electrolyte fuel cells, yet experimental investigations remain limited. This study systematically examines the impact of a through-plane temperature gradient on water distribution using operando synchrotron X-ray radiography. Lowering the anode temperature relative to the cathode causes increased water saturation in the anode GDL. This behavior is mainly due to phase-transition effects, specifically enhanced condensation and suppressed evaporation. A water saturation of 0.168 is observed in the under-rib regions of the anode GDL, which is relatively high compared to commonly reported values. These findings support the growing recognition that anode water accumulation can occur under certain temperature gradients, highlighting the crucial role of temperature gradients and the need for improved anode GDL designs in effective water management.
- Open Access
- 3 July 2024
- Published by Wiley in Advanced Energy and Sustainability Research
- Vol. 5 (10)
Liquid Water Visualization in the Pt‐Loading Cathode Catalyst Layers of Polymer Electrolyte Fuel Cells Using Operando Synchrotron X‐ray Radiography
Water management is important for addressing the challenges posed by next‐generation fuel cell electric vehicles. Although X‐ray imaging techniques are useful for probing the mechanism of water transport in the gas diffusion layer of polymer electrolyte fuel cells, they cannot be easily applied to the Pt‐loading catalyst layer because of its low X‐ray transmittance due to the high absorption coefficient of Pt. Herein, a method to realize the high‐resolution X‐ray imaging of a 30 μm‐thick cathode catalyst layer in polymer electrolyte fuel cells using synchrotron X‐ray radiography is proposed, thus bridging the above gap. The results of operando synchrotron X‐ray radiography measurements reveal that water accumulation in the cathode catalyst layer depends on the cell temperature, feed gas humidity, and cell voltage, while time‐slice analysis shows that the water accumulation rate in the cathode catalyst layer immediately after the power generation is faster than that in the cathode gas diffusion layer. The proposed imaging method can be used to evaluate the water storage capacity of the catalyst layer and thus deepen the understanding of flooding phenomena and cold‐start behavior at subzero temperatures.
- 3 July 2024
- Published by Wiley in Advanced Energy and Sustainability Research
- Vol. 5 (10)
Open AccessLiquid Water Visualization in the Pt‐Loading Cathode Catalyst Layers of Polymer Electrolyte Fuel Cells Using Operando Synchrotron X‐ray Radiography
Water management is important for addressing the challenges posed by next‐generation fuel cell electric vehicles. Although X‐ray imaging techniques are useful for probing the mechanism of water transport in the gas diffusion layer of polymer electrolyte fuel cells, they cannot be easily applied to the Pt‐loading catalyst layer because of its low X‐ray transmittance due to the high absorption coefficient of Pt. Herein, a method to realize the high‐resolution X‐ray imaging of a 30 μm‐thick cathode catalyst layer in polymer electrolyte fuel cells using synchrotron X‐ray radiography is proposed, thus bridging the above gap. The results of operando synchrotron X‐ray radiography measurements reveal that water accumulation in the cathode catalyst layer depends on the cell temperature, feed gas humidity, and cell voltage, while time‐slice analysis shows that the water accumulation rate in the cathode catalyst layer immediately after the power generation is faster than that in the cathode gas diffusion layer. The proposed imaging method can be used to evaluate the water storage capacity of the catalyst layer and thus deepen the understanding of flooding phenomena and cold‐start behavior at subzero temperatures.
- Open Access
- 18 June 2024
- Published by Elsevier in Electrochemistry Communications
- Vol. 165
Operando X-ray radiography of liquid water distribution in 100 mm polymer electrolyte fuel cell channels
- 18 June 2024
- Published by Elsevier in Electrochemistry Communications
- Vol. 165
Open AccessOperando X-ray radiography of liquid water distribution in 100 mm polymer electrolyte fuel cell channels
- Open Access
- 17 April 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Liquid Water Visualization in the Pt-Loading Catalyst Layers of Polymer Electrolyte Fuel Cells Using Operando Synchrotron X-ray Radiography
Water management is important for addressing the challenges posed by next-generation fuel cell electric vehicles. Although X-ray imaging techniques are useful for probing the mechanism of water transport in the gas diffusion layer of polymer electrolyte fuel cells, they cannot be easily applied to the Pt-loading catalyst layer because of its low X-ray transmittance due to the high absorption coefficient of Pt. Herein, we propose a method to realize the high-resolution X-ray imaging of the cathode catalyst layer in polymer electrolyte fuel cells using synchrotron X-ray radiography, thus bridging the above gap. The results of operando synchrotron X-ray radiography measurements reveal that water accumulation in the cathode catalyst layer depends on the cell temperature, feed gas humidity, and cell voltage, while time-slice analysis shows that the water accumulation rate in the cathode catalyst layer is approximately four times that in the cathode gas diffusion layer. The proposed imaging method can be used to evaluate the water uptake capability of the catalyst layer and thus deepen our understanding of flooding phenomena and cold-start behavior at subzero temperatures.
- 17 April 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessLiquid Water Visualization in the Pt-Loading Catalyst Layers of Polymer Electrolyte Fuel Cells Using Operando Synchrotron X-ray Radiography
Water management is important for addressing the challenges posed by next-generation fuel cell electric vehicles. Although X-ray imaging techniques are useful for probing the mechanism of water transport in the gas diffusion layer of polymer electrolyte fuel cells, they cannot be easily applied to the Pt-loading catalyst layer because of its low X-ray transmittance due to the high absorption coefficient of Pt. Herein, we propose a method to realize the high-resolution X-ray imaging of the cathode catalyst layer in polymer electrolyte fuel cells using synchrotron X-ray radiography, thus bridging the above gap. The results of operando synchrotron X-ray radiography measurements reveal that water accumulation in the cathode catalyst layer depends on the cell temperature, feed gas humidity, and cell voltage, while time-slice analysis shows that the water accumulation rate in the cathode catalyst layer is approximately four times that in the cathode gas diffusion layer. The proposed imaging method can be used to evaluate the water uptake capability of the catalyst layer and thus deepen our understanding of flooding phenomena and cold-start behavior at subzero temperatures.