Tobias Böck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tobias Böck has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Ulrich Löhnert
University of Cologne, Pohligstr. 3, 50969 Köln, Germany
19 shared publications - Bernhard Pospichal
Institute for Geophysics and Meteorology, University of Cologne, 50969 Cologne, Germany
17 shared publications - Tobias Marke
University of Cologne, Pohligstr. 3, 50969 Köln, Germany
9 shared publications Christine Knist
German Meteorological Service (DWD), Meteorological Observatory Lindenberg – Richard Aßmann Observatory, 15848 Tauche OT Lindenberg, Germany
6 shared publicationsMoritz Löffler
Institute for Geophysics and Meteorology, University of Cologne, 50923 Cologne, Germany
5 shared publications- Adriana Bailey
Climate and Space Sciences and Engineering, University of Michigan
3 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-24
Comment on egusphere-2026-4994
Advection plays a fundamental role in the transport of heat and moisture within the Atmospheric Boundary Layer (ABL). Recently, horizontal advection has been quantified using ground-based remote sensing networks deployed at multiple locations. This study presents a novel single-site methodology to estimate horizontal temperature and humidity advection. Horizontal gradients are derived from a microwave radiometer (MWR) by exploiting its azimuthal scanning capability, while wind components are obtained from a Doppler wind lidar (DWL). Advection is estimated and a comprehensive uncertainty quantification framework is developed, based on standard error propagation and a Monte Carlo approach that accounts for correlated uncertainties in the MWR's observations. The resulting uncertainties are evaluated relative to the magnitude of advection over a range of horizontal gradients and wind speeds. For typical ABL conditions, the uncertainty associated with humidity advection is approximately 60 % of its estimated value, while temperature advection uncertainties reach 140 %. However, under conditions characterized by strong horizontal gradients and high wind speeds, the observed magnitude of advection exceeds its uncertainties, enabling the detection of significant events such as frontal passages. As proof of concept, two strong advection episodes are analyzed. On 19 June 2022, a pronounced cold advection event was observed, and the current estimation captured intense cooling throughout the ABL, with vertically averaged values reaching −10 K h-1, with relative uncertainties generally below 40 %. A second case, on 8 October 2021, highlights humidity advection, with dominant zonal contribution at around 2300 UTC. The height-averaged estimated humidity advection reached -10 g kg-1 h-1, with uncertainties typically below 30 %. The present study provides a novel advection estimate and its robust assessment of capabilities and limitations, highlighting the clear identification of strong advection events in the ABL, reducing the logistic complexity of capturing this variable.
- 3 November 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-24
Open AccessComment on egusphere-2026-4994
Advection plays a fundamental role in the transport of heat and moisture within the Atmospheric Boundary Layer (ABL). Recently, horizontal advection has been quantified using ground-based remote sensing networks deployed at multiple locations. This study presents a novel single-site methodology to estimate horizontal temperature and humidity advection. Horizontal gradients are derived from a microwave radiometer (MWR) by exploiting its azimuthal scanning capability, while wind components are obtained from a Doppler wind lidar (DWL). Advection is estimated and a comprehensive uncertainty quantification framework is developed, based on standard error propagation and a Monte Carlo approach that accounts for correlated uncertainties in the MWR's observations. The resulting uncertainties are evaluated relative to the magnitude of advection over a range of horizontal gradients and wind speeds. For typical ABL conditions, the uncertainty associated with humidity advection is approximately 60 % of its estimated value, while temperature advection uncertainties reach 140 %. However, under conditions characterized by strong horizontal gradients and high wind speeds, the observed magnitude of advection exceeds its uncertainties, enabling the detection of significant events such as frontal passages. As proof of concept, two strong advection episodes are analyzed. On 19 June 2022, a pronounced cold advection event was observed, and the current estimation captured intense cooling throughout the ABL, with vertically averaged values reaching −10 K h-1, with relative uncertainties generally below 40 %. A second case, on 8 October 2021, highlights humidity advection, with dominant zonal contribution at around 2300 UTC. The height-averaged estimated humidity advection reached -10 g kg-1 h-1, with uncertainties typically below 30 %. The present study provides a novel advection estimate and its robust assessment of capabilities and limitations, highlighting the clear identification of strong advection events in the ABL, reducing the logistic complexity of capturing this variable.
- Open Access
- 5 October 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-24
Evaluating the scanning capabilities of an MWR to estimate temperature and humidity advection from a single site
Advection plays a fundamental role in the transport of heat and moisture within the Atmospheric Boundary Layer (ABL). Recently, horizontal advection has been quantified using ground-based remote sensing networks deployed at multiple locations. This study presents a novel single-site methodology to estimate horizontal temperature and humidity advection. Horizontal gradients are derived from a microwave radiometer (MWR) by exploiting its azimuthal scanning capability, while wind components are obtained from a Doppler wind lidar (DWL). Advection is estimated and a comprehensive uncertainty quantification framework is developed, based on standard error propagation and a Monte Carlo approach that accounts for correlated uncertainties in the MWR's observations. The resulting uncertainties are evaluated relative to the magnitude of advection over a range of horizontal gradients and wind speeds. For typical ABL conditions, the uncertainty associated with humidity advection is approximately 60 % of its estimated value, while temperature advection uncertainties reach 140 %. However, under conditions characterized by strong horizontal gradients and high wind speeds, the observed magnitude of advection exceeds its uncertainties, enabling the detection of significant events such as frontal passages. As proof of concept, two strong advection episodes are analyzed. On 19 June 2022, a pronounced cold advection event was observed, and the current estimation captured intense cooling throughout the ABL, with vertically averaged values reaching −10 K h-1, with relative uncertainties generally below 40 %. A second case, on 8 October 2021, highlights humidity advection, with dominant zonal contribution at around 2300 UTC. The height-averaged estimated humidity advection reached -10 g kg-1 h-1, with uncertainties typically below 30 %. The present study provides a novel advection estimate and its robust assessment of capabilities and limitations, highlighting the clear identification of strong advection events in the ABL, reducing the logistic complexity of capturing this variable.
- 5 October 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-24
Open AccessEvaluating the scanning capabilities of an MWR to estimate temperature and humidity advection from a single site
Advection plays a fundamental role in the transport of heat and moisture within the Atmospheric Boundary Layer (ABL). Recently, horizontal advection has been quantified using ground-based remote sensing networks deployed at multiple locations. This study presents a novel single-site methodology to estimate horizontal temperature and humidity advection. Horizontal gradients are derived from a microwave radiometer (MWR) by exploiting its azimuthal scanning capability, while wind components are obtained from a Doppler wind lidar (DWL). Advection is estimated and a comprehensive uncertainty quantification framework is developed, based on standard error propagation and a Monte Carlo approach that accounts for correlated uncertainties in the MWR's observations. The resulting uncertainties are evaluated relative to the magnitude of advection over a range of horizontal gradients and wind speeds. For typical ABL conditions, the uncertainty associated with humidity advection is approximately 60 % of its estimated value, while temperature advection uncertainties reach 140 %. However, under conditions characterized by strong horizontal gradients and high wind speeds, the observed magnitude of advection exceeds its uncertainties, enabling the detection of significant events such as frontal passages. As proof of concept, two strong advection episodes are analyzed. On 19 June 2022, a pronounced cold advection event was observed, and the current estimation captured intense cooling throughout the ABL, with vertically averaged values reaching −10 K h-1, with relative uncertainties generally below 40 %. A second case, on 8 October 2021, highlights humidity advection, with dominant zonal contribution at around 2300 UTC. The height-averaged estimated humidity advection reached -10 g kg-1 h-1, with uncertainties typically below 30 %. The present study provides a novel advection estimate and its robust assessment of capabilities and limitations, highlighting the clear identification of strong advection events in the ABL, reducing the logistic complexity of capturing this variable.
- Open Access
- 6 November 2025
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 18 (21) , 6251-6270
Instrument uncertainties of network-suitable ground-based microwave radiometers: overview, quantification, and mitigation strategies
To enhance observations of the atmospheric boundary layer (ABL), the European Meteorological Network (EUMETNET), and the Aerosol, Clouds, and Trace Gases Research Infrastructure (ACTRIS) are currently collaborating to establish networks of microwave radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs are therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, the Generation 5 Humidity and Temperature Profiler, HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤0.11 K). Long-term drifts or jumps between calibrations, which are at least 2 months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every 6 months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band in the zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K, compared with a dry radome.
- 6 November 2025
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 18 (21) , 6251-6270
Open AccessInstrument uncertainties of network-suitable ground-based microwave radiometers: overview, quantification, and mitigation strategies
To enhance observations of the atmospheric boundary layer (ABL), the European Meteorological Network (EUMETNET), and the Aerosol, Clouds, and Trace Gases Research Infrastructure (ACTRIS) are currently collaborating to establish networks of microwave radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs are therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, the Generation 5 Humidity and Temperature Profiler, HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤0.11 K). Long-term drifts or jumps between calibrations, which are at least 2 months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every 6 months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band in the zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K, compared with a dry radome.
- Open Access
- 27 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-32
Reply on RC1
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- 27 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-32
Open AccessReply on RC1
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- Open Access
- 27 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-32
Reply on RC2
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- 27 June 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-32
Open AccessReply on RC2
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- Open Access
- 21 May 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-32
Comment on egusphere-2025-1727
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- 21 May 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-32
Open AccessComment on egusphere-2025-1727
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- Open Access
- 15 May 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-32
Comment on egusphere-2025-1727
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- 15 May 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-32
Open AccessComment on egusphere-2025-1727
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- Open Access
- 25 April 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-32
Instrument uncertainties of network-suitable ground-based microwave radiometers: overview, quantification, and mitigation strategies
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- 25 April 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-32
Open AccessInstrument uncertainties of network-suitable ground-based microwave radiometers: overview, quantification, and mitigation strategies
To enhance observations of the Atmospheric Boundary Layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently collaborating to establish networks of MicroWave Radiometers (MWRs). MWRs can be used to derive thermodynamic profiles within the ABL. Understanding and assessing instrument uncertainties of state-of-the-art MWRs is therefore crucial for accurate observations and also data assimilation purposes. Some national weather services are currently exploring the potential of MWR networks to improve short-term weather forecasts. In this paper, we discuss uncertainties inherent to the MWR instrument itself, namely (1) radiometric noise, (2) long-term drifts and jumps, (3) calibration repeatability, (4) biases/systematic differences between instruments, and (5) radome degradation. These uncertainties are expressed in brightness temperatures. For state-of-the-art MWRs (here, Generation 5 Humidity and Temperature PROfiler HATPRO-Gen5), radiometric noise at ambient temperatures is a maximum of 0.32 K in the V-band but usually lower, especially near cold load temperature ranges in the K-band (≤ 0.11 K). Long-term drifts or jumps between calibrations, which are at least two months apart, are usually below 0.4 K in the K-band and 1.0 K in the V-band but can also be higher. Drifts do not follow a discernable timely pattern and are therefore not easily quantifiable in a meaningful way. Calibrating at least every six months is thus advised. Calibration repeatability is shown to be well under 0.16 K. Mean brightness temperature differences between two HATPRO-Gen5 instruments are shown to be as high as 0.15 K in the K-band and 0.58 K in the V-band at zenith viewing direction. The radome has significantly degraded due to weathering and needs to be replaced if, 10 min after a rain event, residual water on its surface still causes a temperature deviation of more than 2 K compared to a dry radome.
- Open Access
- 16 August 2024
- Published by Copernicus GmbH
Microwave radiometer data quality monitoring and retrieval development framework for network operation
Ground-based microwave radiometers (MWR) provide valuable information on thermodynamic profiles and cloud liquid water by measuring the thermal emission, expressed as brightness temperatures (TB), of atmospheric gases and hydrometeors in several channels, and have thus become a widely used tool in atmospheric remote sensing. MWR are being deployed for process studies of boundary layer structure and development, as well as for operational data assimilation in numerical weather prediction models (NWP). Due to their robustness and ability to operate unattended in long-term deployments, MWR are currently implemented into two observation networks in Europe. EUMETNET's profiling network E-PROFILE and the European Research Infrastructure ACTRIS are both establishing centralized near-real-time processing and provision of MWR data at about 30 stations, covering different climate zones.Assessing the quality of long-term data sets in a network configuration is a crucial part for ensuring continuous operation and detecting instrument malfunctions. Near-real-time monitoring of data streams can be utilized to help station operators with instrument maintenance and statistical analysis of critical instrument parameters can unveil degradation and resulting drifts. In ACTRIS, a centralized monitoring is being developed with an online graphical interface and instrument specific alerting system, allowing for quick responses and initiation of mitigation strategies to avoid a prolonged impact of instrument failures on data quality. For MWR the stability of all receiver components, which can be prone to the environmental temperature, is an important factor in the quality assessment and needs to be monitored together with the spectral behavior of observed TB for automated data flagging. In addition, parameters of regularly performed relative calibrations (automated procedure) and absolute calibrations (with a liquid nitrogen cooled target) should be considered in any long-term operation for a better evaluation of the system status.Another tool for judging the instrument performance is the detection of systematic errors by comparing the observations to a model background (O-B). During scenes with no liquid water clouds present, TB are simulated by a radiative transfer model with input from a NWP model. The resulting differences to the observations are exploited in a statistical way to detect drifts, erroneous absolute calibrations, and for TB bias corrections. A similar approach of simulating TB will also be used to serve as training data set for developing a statistical retrieval, which is based on a common data input, needed to ensure homogeneous MWR data streams throughout the network. The performance of the retrieval method will be evaluated in an inter-comparison study, involving different retrieval algorithms, based on observations during the “PAris region urbaN Atmospheric observations and models for Multidisciplinary rEsearch” (PANAME) campaign.
- 16 August 2024
- Published by Copernicus GmbH
Open AccessMicrowave radiometer data quality monitoring and retrieval development framework for network operation
Ground-based microwave radiometers (MWR) provide valuable information on thermodynamic profiles and cloud liquid water by measuring the thermal emission, expressed as brightness temperatures (TB), of atmospheric gases and hydrometeors in several channels, and have thus become a widely used tool in atmospheric remote sensing. MWR are being deployed for process studies of boundary layer structure and development, as well as for operational data assimilation in numerical weather prediction models (NWP). Due to their robustness and ability to operate unattended in long-term deployments, MWR are currently implemented into two observation networks in Europe. EUMETNET's profiling network E-PROFILE and the European Research Infrastructure ACTRIS are both establishing centralized near-real-time processing and provision of MWR data at about 30 stations, covering different climate zones.Assessing the quality of long-term data sets in a network configuration is a crucial part for ensuring continuous operation and detecting instrument malfunctions. Near-real-time monitoring of data streams can be utilized to help station operators with instrument maintenance and statistical analysis of critical instrument parameters can unveil degradation and resulting drifts. In ACTRIS, a centralized monitoring is being developed with an online graphical interface and instrument specific alerting system, allowing for quick responses and initiation of mitigation strategies to avoid a prolonged impact of instrument failures on data quality. For MWR the stability of all receiver components, which can be prone to the environmental temperature, is an important factor in the quality assessment and needs to be monitored together with the spectral behavior of observed TB for automated data flagging. In addition, parameters of regularly performed relative calibrations (automated procedure) and absolute calibrations (with a liquid nitrogen cooled target) should be considered in any long-term operation for a better evaluation of the system status.Another tool for judging the instrument performance is the detection of systematic errors by comparing the observations to a model background (O-B). During scenes with no liquid water clouds present, TB are simulated by a radiative transfer model with input from a NWP model. The resulting differences to the observations are exploited in a statistical way to detect drifts, erroneous absolute calibrations, and for TB bias corrections. A similar approach of simulating TB will also be used to serve as training data set for developing a statistical retrieval, which is based on a common data input, needed to ensure homogeneous MWR data streams throughout the network. The performance of the retrieval method will be evaluated in an inter-comparison study, involving different retrieval algorithms, based on observations during the “PAris region urbaN Atmospheric observations and models for Multidisciplinary rEsearch” (PANAME) campaign.
- Open Access
- 15 January 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (1) , 219-233
Measurement uncertainties of scanning microwave radiometers and their influence on temperature profiling
In order to improve observations of the atmospheric boundary layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently working on building networks of microwave radiometers (MWRs). Elevation-scanning MWRs are well suited to obtain temperature profiles of the atmosphere, especially within the ABL. Understanding and assessing measurement uncertainties of state-of-the-art scanning MWRs is therefore crucial for accurate temperature profiling. In this paper, we discuss measurement uncertainties due to the instrument setup and originating from external sources, namely (1) horizontal inhomogeneities of the atmosphere, (2) pointing errors or a tilt of the instrument, (3) physical obstacles in the line of sight of the instrument, and (4) radio frequency interference (RFI). Horizontal inhomogeneities from observations at the Jülich Observatory for Cloud Evolution (JOYCE) are shown to have a small impact on retrieved temperature profiles ( in the 25th and 75th percentiles below 3000 m). Typical instrument tilts, that could be caused by uncertainties during the instrument setup, also have a very small impact on temperature profiles and are smaller than 0.1 K below 3000 m for up to 1∘ of tilt. Physical obstacles at ambient temperatures and in the line of sight and filling the complete beam of the MWR at the lowest elevation angle of 5.4∘ have to be at least 600 m away from the instrument in order to have an impact of less than 0.1 K on obtained temperature profiles. If the obstacle is 5 K warmer than its surroundings then the obstacle should be at least 2700 m away. Finally, we present an approach on how to detect RFI with an MWR with azimuth and elevation-scanning capabilities. In this study, we detect RFIs in a water vapor channel that does not influence temperature retrievals but would be relevant if the MWR were used to detect horizontal humidity inhomogeneities.- 15 January 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (1) , 219-233
Open AccessMeasurement uncertainties of scanning microwave radiometers and their influence on temperature profiling
In order to improve observations of the atmospheric boundary layer (ABL), the European Meteorological Network, EUMETNET, and the Aerosol, Clouds, and Trace Gases Research Infrastructure, ACTRIS, are currently working on building networks of microwave radiometers (MWRs). Elevation-scanning MWRs are well suited to obtain temperature profiles of the atmosphere, especially within the ABL. Understanding and assessing measurement uncertainties of state-of-the-art scanning MWRs is therefore crucial for accurate temperature profiling. In this paper, we discuss measurement uncertainties due to the instrument setup and originating from external sources, namely (1) horizontal inhomogeneities of the atmosphere, (2) pointing errors or a tilt of the instrument, (3) physical obstacles in the line of sight of the instrument, and (4) radio frequency interference (RFI). Horizontal inhomogeneities from observations at the Jülich Observatory for Cloud Evolution (JOYCE) are shown to have a small impact on retrieved temperature profiles ( in the 25th and 75th percentiles below 3000 m). Typical instrument tilts, that could be caused by uncertainties during the instrument setup, also have a very small impact on temperature profiles and are smaller than 0.1 K below 3000 m for up to 1∘ of tilt. Physical obstacles at ambient temperatures and in the line of sight and filling the complete beam of the MWR at the lowest elevation angle of 5.4∘ have to be at least 600 m away from the instrument in order to have an impact of less than 0.1 K on obtained temperature profiles. If the obstacle is 5 K warmer than its surroundings then the obstacle should be at least 2700 m away. Finally, we present an approach on how to detect RFI with an MWR with azimuth and elevation-scanning capabilities. In this study, we detect RFIs in a water vapor channel that does not influence temperature retrievals but would be relevant if the MWR were used to detect horizontal humidity inhomogeneities.