Muhamad Zabidi Ahmad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Muhamad Zabidi Ahmad has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Mohamad Nazri Munawar Khan
School of Medical Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia
2 shared publicationsMohd Shafie Abdullah
Department of Radiology, School of Medical Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia
2 shared publications- Mohd Zahri Abdul Aziz
Advanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia
2 shared publications - Alex Cheen Hoe Khoo
Department of Nuclear Medicine, Penang Adventist Hospital, Pulau Pinang, Malaysia
1 shared publication Ang Soo Fan
Department of Medical Oncology, National Cancer Centre Singapore, Singapore
1 shared publication- Gokula Kumar Appalanaido
Biomedical Imaging Department/Oncology and Radiotherapy Unit, Advanced Medical & Dental Institute, Universiti Sains Malaysia, Kepala Batas, Malaysia
1 shared publication
Latest Publications
- Open Access
- 27 September 2022
- Published by Taylor & Francis in Hepatic Oncology
- Vol. 9 (3) , HEP44
Pathological complete Response with Immunotherapy and Brachytherapy to 15 Metastatic Liver Lesions in a Single Patient
Materials & methods: High dose rate interstitial brachytherapy (HDR-IBT) treatment plan for 15 metastatic liver lesions in a patient with pancreatic cancer was retrieved and analyzed for liver dose...
- 27 September 2022
- Published by Taylor & Francis in Hepatic Oncology
- Vol. 9 (3) , HEP44
Open AccessPathological complete Response with Immunotherapy and Brachytherapy to 15 Metastatic Liver Lesions in a Single Patient
Materials & methods: High dose rate interstitial brachytherapy (HDR-IBT) treatment plan for 15 metastatic liver lesions in a patient with pancreatic cancer was retrieved and analyzed for liver dose...
- Open Access
- 1 February 2021
- Published by Oxford University Press (OUP) in Oxford Medical Case Reports
- Vol. 2021 (2) , 43-46
Compensatory renal hypertrophy in reflux nephropathy presenting as hypertensive emergency
Hypertensive emergency in the paediatric population is not uncommon. However, due to its numerous etiologies, care should be taken in determining the approach of management. We report a case of a child who presented with double vision, giddiness and elevated blood pressure. Blood investigations were normal. Renal ultrasound and magnetic resonance imaging of the abdomen were performed which both showed findings suspicious of a large heterogeneous mass at the lower pole of the left kidney with dysplastic right kidney. A final diagnosis of bilateral vesicoureteric reflux with left compensatory hypertrophy was made based upon micturating cystourethrography findings and was later confirmed by 99mTc-dimercaptosuccinic acid (DMSA) study. The objective of this case is to share the importance of the appropriate choice of radiological examinations, not only in achieving an accurate diagnosis but to ensure that unnecessary investigations are avoided.
- 1 February 2021
- Published by Oxford University Press (OUP) in Oxford Medical Case Reports
- Vol. 2021 (2) , 43-46
Open AccessCompensatory renal hypertrophy in reflux nephropathy presenting as hypertensive emergency
Hypertensive emergency in the paediatric population is not uncommon. However, due to its numerous etiologies, care should be taken in determining the approach of management. We report a case of a child who presented with double vision, giddiness and elevated blood pressure. Blood investigations were normal. Renal ultrasound and magnetic resonance imaging of the abdomen were performed which both showed findings suspicious of a large heterogeneous mass at the lower pole of the left kidney with dysplastic right kidney. A final diagnosis of bilateral vesicoureteric reflux with left compensatory hypertrophy was made based upon micturating cystourethrography findings and was later confirmed by 99mTc-dimercaptosuccinic acid (DMSA) study. The objective of this case is to share the importance of the appropriate choice of radiological examinations, not only in achieving an accurate diagnosis but to ensure that unnecessary investigations are avoided.
- Open Access
- 1 June 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1248 (1) , 012067
Establishment of institutional diagnostic reference level for CT imaging associated with multiple anatomical regions
Advancement of CT technology has increased the frequency of CT scanning in diagnosis. However, the concern on dose increment that related to radiation-associated health risk from CT also improved. The aim of this study was to establish an institutional diagnostic reference level (DRL) for computed tomography (CT) imaging associated with multiple or combined anatomical regions and compared with other international DRLs. CT dose data of 705 subjects were collected retrospectively from January 2015 until December 2017 at AMDI, USM, Malaysia. The most common CT examination of combined anatomical regions were neck-thorax-abdomen-pelvis (NTAP), thorax-abdomen (TA), thorax-abdomen-pelvis (TAP), and abdomen-pelvis (AP). CT dose data such as CTDIvol, CTDIw and dose-length product (DLP) were collected including contrast, non-contrast, single-phasic, and multiphasic examinations. The 50th and 75th percentile of dose distribution were calculated and compared with other established DRLs. TAP CT was the most frequently performed examination at AMDI (73%). The local dose values of multiphasic and non-contrast examinations were higher compared to single phasic and contrast study. The results show a weak correlation between different CT sequences and DRLs for AP examination. Local dose values reported for all CT examinations were below any international DRLs except for CT TAP (multiphasic) study. The institutional DRL for combined anatomical regions was established using the third quartile values of dose distribution and is categorized based on CT sequences.
- 1 June 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1248 (1) , 012067
Open AccessEstablishment of institutional diagnostic reference level for CT imaging associated with multiple anatomical regions
Advancement of CT technology has increased the frequency of CT scanning in diagnosis. However, the concern on dose increment that related to radiation-associated health risk from CT also improved. The aim of this study was to establish an institutional diagnostic reference level (DRL) for computed tomography (CT) imaging associated with multiple or combined anatomical regions and compared with other international DRLs. CT dose data of 705 subjects were collected retrospectively from January 2015 until December 2017 at AMDI, USM, Malaysia. The most common CT examination of combined anatomical regions were neck-thorax-abdomen-pelvis (NTAP), thorax-abdomen (TA), thorax-abdomen-pelvis (TAP), and abdomen-pelvis (AP). CT dose data such as CTDIvol, CTDIw and dose-length product (DLP) were collected including contrast, non-contrast, single-phasic, and multiphasic examinations. The 50th and 75th percentile of dose distribution were calculated and compared with other established DRLs. TAP CT was the most frequently performed examination at AMDI (73%). The local dose values of multiphasic and non-contrast examinations were higher compared to single phasic and contrast study. The results show a weak correlation between different CT sequences and DRLs for AP examination. Local dose values reported for all CT examinations were below any international DRLs except for CT TAP (multiphasic) study. The institutional DRL for combined anatomical regions was established using the third quartile values of dose distribution and is categorized based on CT sequences.
- Open Access
- 1 January 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 298 (1) , 012020
Mass attenuation coefficients of several bio-adhesive based oil palm particleboards at 16.59-25.26 keV photon energies
Particleboards made of oil palm with addition of polylactic acid (PLA), starch, and fish oil were fabricated with target density of 1.0 g/cm3. The mass attenuation coefficients of the particleboards were measured using x-ray fluorescence (XRF) configuration in conjunction with niobium, molybdenum, palladium and tin metal plates that provided Kα1 photon energies between 16.59 and 25.26 keV. The results were compared to the calculated value of water using XCOM. The results showed that all particleboards having mass attenuation coefficients near to the value of water with the mass attenuation coefficient different less than 0.25. The method of fabrication did not give significant different to the mass attenuation coefficients of the particleboards. The results had indicated the potential of bio-adhesive based palm oil particleboards to be developed as phantoms for low energy photons.
- 1 January 2018
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 298 (1) , 012020
Open AccessMass attenuation coefficients of several bio-adhesive based oil palm particleboards at 16.59-25.26 keV photon energies
Particleboards made of oil palm with addition of polylactic acid (PLA), starch, and fish oil were fabricated with target density of 1.0 g/cm3. The mass attenuation coefficients of the particleboards were measured using x-ray fluorescence (XRF) configuration in conjunction with niobium, molybdenum, palladium and tin metal plates that provided Kα1 photon energies between 16.59 and 25.26 keV. The results were compared to the calculated value of water using XCOM. The results showed that all particleboards having mass attenuation coefficients near to the value of water with the mass attenuation coefficient different less than 0.25. The method of fabrication did not give significant different to the mass attenuation coefficients of the particleboards. The results had indicated the potential of bio-adhesive based palm oil particleboards to be developed as phantoms for low energy photons.