Michael J. Dunbar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael J. Dunbar has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Janie L. Astephen Wilson
School of Biomedical Engineering, Dalhousie University, Halifax, NS, Canada
5 shared publications - Eric Bohm
Department of Surgery, University of Manitoba, Winnipeg, MB, Canada
3 shared publications - Bart Godefridus Pijls
Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
2 shared publications - Catherine Allyson Jones
Faculty of Rehabilitation Medicine University of Alberta Edmonton Alberta Canada
2 shared publications - Deborah A. Marshall
Departments of Community Health Sciences and Medicine, Cumming School of Medicine and McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Canada
2 shared publications - Elise K. Laende
Systems Design Engineering, University of Waterloo, Canada
2 shared publications
Latest Publications
- 1 April 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 42 (2) , 85-94
Repeatability of Knee Kinematic Gait Outcomes Using a Novel Hospital Hallway Setup of a Markerless Motion Capture System
Instrumented gait analysis has traditionally been isolated to laboratory, marker-based optoelectronic motion capture systems, which limits clinical uptake. Markerless motion capture (MMC) systems driven by trained machine learning algorithms offer high-throughput solutions for translational clinical opportunities. The aim of this study was to examine the day-to-day repeatability of discrete knee kinematic gait metrics in a healthy population using an MMC system uniquely installed in a hospital hallway. Twenty healthy adults (13 females, 7 males) participated in 3 overground hallway gait sessions, on average 11 days apart, using a novel MMC system setup. Intraclass correlation coefficients, standard errors of measurement, and minimal detectable changes were examined for each gait outcome. Results indicated good-to-excellent repeatability, with most (7/8) outcomes having intraclass correlation coefficient values over .86. Standard error of measurement values for all kinematic outcomes were less than 2.0°, and minimal detectable change values were less than 4.7°. Our novel setup of a hospital hallway MMC system produced highly repeatable gait kinematic metrics in a population of healthy adults. Repeatability errors from this study can be used as a healthy reference for future applications of this system.
- 1 April 2026
- Published by Human Kinetics in Journal of Applied Biomechanics
- Vol. 42 (2) , 85-94
Repeatability of Knee Kinematic Gait Outcomes Using a Novel Hospital Hallway Setup of a Markerless Motion Capture System
Instrumented gait analysis has traditionally been isolated to laboratory, marker-based optoelectronic motion capture systems, which limits clinical uptake. Markerless motion capture (MMC) systems driven by trained machine learning algorithms offer high-throughput solutions for translational clinical opportunities. The aim of this study was to examine the day-to-day repeatability of discrete knee kinematic gait metrics in a healthy population using an MMC system uniquely installed in a hospital hallway. Twenty healthy adults (13 females, 7 males) participated in 3 overground hallway gait sessions, on average 11 days apart, using a novel MMC system setup. Intraclass correlation coefficients, standard errors of measurement, and minimal detectable changes were examined for each gait outcome. Results indicated good-to-excellent repeatability, with most (7/8) outcomes having intraclass correlation coefficient values over .86. Standard error of measurement values for all kinematic outcomes were less than 2.0°, and minimal detectable change values were less than 4.7°. Our novel setup of a hospital hallway MMC system produced highly repeatable gait kinematic metrics in a population of healthy adults. Repeatability errors from this study can be used as a healthy reference for future applications of this system.
- Open Access
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Following the Footsteps: Wearable Sensors Quantify Kinetic Gait Outcomes Before and After Knee Arthroplasty
A common feature of knee osteoarthritis (OA) gait is a stiff-knee pattern characterized by minimal range of motion and more constant loading through the stance phase. Previous work has shown that knee joint kinematics and kinetics following arthroplasty surgery often do not return to age-matched control levels for most patients. Quantification of these gait patterns has traditionally relied on laboratory-based optoelectronic motion capture and synchronized force plates, which are costly, spatially constrained, and limit the clinical scalability of relevant gait metrics. The purpose of this study was to establish an inertial measurement unit (IMU) protocol capable of capturing clinically relevant kinetic gait patterns in patients with knee OA, with the goal of enabling out of laboratory kinetic gait assessment. Multivariate relationships between the knee flexion and adduction moment patterns representing ‘stiff-knee’ kinetic gait patterns and lower extremity accelerations and angular velocities from lower-extremity worn inertial sensors were examined in patients with end-stage knee OA. Shank-mounted IMU models explained significant variance in the pattern of the knee flexion and adduction moment waveforms (R2=0.55-0.64, p<0.01), and inclusion of foot-mounted sensors further improved model performance (R2=0.67-0.69, p<0.01). These findings demonstrated, for the first time, that OA-specific, clinically relevant temporal features of knee moments can be reasonably estimated using IMU data, enabling continuous, real-world, evaluation of OA disease status.
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFollowing the Footsteps: Wearable Sensors Quantify Kinetic Gait Outcomes Before and After Knee Arthroplasty
A common feature of knee osteoarthritis (OA) gait is a stiff-knee pattern characterized by minimal range of motion and more constant loading through the stance phase. Previous work has shown that knee joint kinematics and kinetics following arthroplasty surgery often do not return to age-matched control levels for most patients. Quantification of these gait patterns has traditionally relied on laboratory-based optoelectronic motion capture and synchronized force plates, which are costly, spatially constrained, and limit the clinical scalability of relevant gait metrics. The purpose of this study was to establish an inertial measurement unit (IMU) protocol capable of capturing clinically relevant kinetic gait patterns in patients with knee OA, with the goal of enabling out of laboratory kinetic gait assessment. Multivariate relationships between the knee flexion and adduction moment patterns representing ‘stiff-knee’ kinetic gait patterns and lower extremity accelerations and angular velocities from lower-extremity worn inertial sensors were examined in patients with end-stage knee OA. Shank-mounted IMU models explained significant variance in the pattern of the knee flexion and adduction moment waveforms (R2=0.55-0.64, p<0.01), and inclusion of foot-mounted sensors further improved model performance (R2=0.67-0.69, p<0.01). These findings demonstrated, for the first time, that OA-specific, clinically relevant temporal features of knee moments can be reasonably estimated using IMU data, enabling continuous, real-world, evaluation of OA disease status.
- 5 March 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (5) , e15
Heat and Illumination on the Important Topic of Postoperative Periprosthetic Femoral Fractures
- 5 March 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (5) , e15
Heat and Illumination on the Important Topic of Postoperative Periprosthetic Femoral Fractures
- Open Access
- 10 December 2024
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 95, 730-736
Sex-based differences in risk of revision for infection after hip, knee, shoulder, and ankle arthroplasty in osteoarthritis patients: a multinational registry study of 4,800,000 implants
Background and purpose: We aimed to determine sex differences for periprosthetic joint infections after primary arthroplasty of the hip, knee, ankle, and shoulder in osteoarthritis patients in an international perspective.Methods: This is a multinational combined arthroplasty registry study. Each arthroplasty registry performed Cox-regression analysis of their data and reported the crude and adjusted hazard ratios (HR) with an a priori designed data form. A random-effects model was used to pool these HRs to estimate an overall HR with 95% confidence interval (CI). Adjustment was undertaken for patient age, BMI, ASA grade, type of fixation, and type of implant. 9 arthroplasty registries participated. Patients who received primary total joint arthroplasty for primary osteoarthritis were considered: 2,134,313 hip arthroplasties, 2,658,237 knee arthroplasties, 57,889 shoulder arthroplasties, and 8,445 ankle arthroplasties. We calculated hazard ratios (HR) for the overall risk of complete revision due to infection for each implant type and follow-up.Results: The pooled HR for revision due to infection for men compared with women at 1-year follow-up was 1.60 (95% confidence interval [CI] 1.42–1.80) for hip arthroplasties; 2.06 (CI 1.90–2.46) for knee arthroplasties; 4.51 (CI 2.99–6.80) for shoulder arthroplasties; and 0.87 (CI 0.46–1.62) for ankle arthroplasties. These results remained consistent over time and were identified in both unadjusted and adjusted models.Conclusion: Men have a higher risk of revision due to infection than women after primary hip, knee, and shoulder arthroplasty. No evidence of difference was found for ankle arthroplasty. These elevated relative risks persist in the fully adjusted investigations and over the 10-year postoperative period studied.
- 10 December 2024
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 95, 730-736
Open AccessSex-based differences in risk of revision for infection after hip, knee, shoulder, and ankle arthroplasty in osteoarthritis patients: a multinational registry study of 4,800,000 implants
Background and purpose: We aimed to determine sex differences for periprosthetic joint infections after primary arthroplasty of the hip, knee, ankle, and shoulder in osteoarthritis patients in an international perspective.Methods: This is a multinational combined arthroplasty registry study. Each arthroplasty registry performed Cox-regression analysis of their data and reported the crude and adjusted hazard ratios (HR) with an a priori designed data form. A random-effects model was used to pool these HRs to estimate an overall HR with 95% confidence interval (CI). Adjustment was undertaken for patient age, BMI, ASA grade, type of fixation, and type of implant. 9 arthroplasty registries participated. Patients who received primary total joint arthroplasty for primary osteoarthritis were considered: 2,134,313 hip arthroplasties, 2,658,237 knee arthroplasties, 57,889 shoulder arthroplasties, and 8,445 ankle arthroplasties. We calculated hazard ratios (HR) for the overall risk of complete revision due to infection for each implant type and follow-up.Results: The pooled HR for revision due to infection for men compared with women at 1-year follow-up was 1.60 (95% confidence interval [CI] 1.42–1.80) for hip arthroplasties; 2.06 (CI 1.90–2.46) for knee arthroplasties; 4.51 (CI 2.99–6.80) for shoulder arthroplasties; and 0.87 (CI 0.46–1.62) for ankle arthroplasties. These results remained consistent over time and were identified in both unadjusted and adjusted models.Conclusion: Men have a higher risk of revision due to infection than women after primary hip, knee, and shoulder arthroplasty. No evidence of difference was found for ankle arthroplasty. These elevated relative risks persist in the fully adjusted investigations and over the 10-year postoperative period studied.
- Open Access
- 30 November 2023
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 94, 577-587
6-month migration sufficient for evaluation of total knee replacements: a systematic review and meta-analysis
Background and purpose: This updated meta-analysis evaluates the migration pattern of the tibial component of primary total knee replacements measured with radiostereometric analysis (RSA). We aimed to evaluate whether 6-month maximum total point motion (MTPM) values could be used instead of 1-year MTPM for RSA threshold testing and to present the pooled migration patterns for different implant designs that can be used as a benchmark.Patients and methods: The search included all published RSA studies on migration patterns of tibial components until 2023. Study groups were classified according to their prosthesis brand, fixation, and insert (PFI). Sub-analyses were performed to compare the mean tibial component migration patterns of different implant variables, stratified according to fixation.Results: 96 studies (43 new studies), including 197 study groups and 4,706 knees, were included. Most migration occurred within the first 6 postoperative months (126 study groups: mean 0.58 mm, 95% confidence interval [CI] 0.50–0.65), followed by minimal migration between 6 and 12 months (197 study groups: mean 0.04 mm, CI 0.03–0.06), irrespective of the fixation method used. Distinct migration patterns were observed among the different fixation methods. No differences were found in migration patterns among cemented components in any of the sub-group analyses conducted. For uncemented implants, trabecular metal surfaced components seemed to migrate less than porous-coated or uncoated componentsConclusion: Based on the small difference between MTPM values at 6 months and 1 year, MTPM at 6 months could be used instead of MTPM at 1 year for RSA threshold testing. The pooled migration patterns can be used as benchmark for evaluation of new implants by defining fixation-specific RSA thresholds when combined with implant survival.
- 30 November 2023
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 94, 577-587
Open Access6-month migration sufficient for evaluation of total knee replacements: a systematic review and meta-analysis
Background and purpose: This updated meta-analysis evaluates the migration pattern of the tibial component of primary total knee replacements measured with radiostereometric analysis (RSA). We aimed to evaluate whether 6-month maximum total point motion (MTPM) values could be used instead of 1-year MTPM for RSA threshold testing and to present the pooled migration patterns for different implant designs that can be used as a benchmark.Patients and methods: The search included all published RSA studies on migration patterns of tibial components until 2023. Study groups were classified according to their prosthesis brand, fixation, and insert (PFI). Sub-analyses were performed to compare the mean tibial component migration patterns of different implant variables, stratified according to fixation.Results: 96 studies (43 new studies), including 197 study groups and 4,706 knees, were included. Most migration occurred within the first 6 postoperative months (126 study groups: mean 0.58 mm, 95% confidence interval [CI] 0.50–0.65), followed by minimal migration between 6 and 12 months (197 study groups: mean 0.04 mm, CI 0.03–0.06), irrespective of the fixation method used. Distinct migration patterns were observed among the different fixation methods. No differences were found in migration patterns among cemented components in any of the sub-group analyses conducted. For uncemented implants, trabecular metal surfaced components seemed to migrate less than porous-coated or uncoated componentsConclusion: Based on the small difference between MTPM values at 6 months and 1 year, MTPM at 6 months could be used instead of MTPM at 1 year for RSA threshold testing. The pooled migration patterns can be used as benchmark for evaluation of new implants by defining fixation-specific RSA thresholds when combined with implant survival.
- Open Access
- 30 November 2023
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 94, 555-559
A low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty
Background and purpose: The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been published for this type of imaging system, thus the goal of this study was to assess the precision of RSA in vivo utilizing a low radiation biplanar imager.Patients and methods: At a mean of 5 years post-surgery (range 1.4–7.5 years), 15 total knee arthroplasty (TKA) participants (mean age 67 years at the time of imaging, 12 female, 3 male) with RSA markers implanted during index surgery were scanned twice at the same visit in the EOS imager. Precision of marker-based analysis was calculated by comparing the position of the implant relative to the underlying bone between the 2 examinations.Results: The 95% limit of precision was 0.11, 0.04, and 0.15 mm along the x, y, and z axes, respectively and 0.15°, 0.20°, and 0.14° around the same axes.Conclusion: This precision study has shown an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20°, well within published uniplanar values for conventional arthroplasty RSA, with the added benefit of weight-bearing imaging, a lower radiation dose, and without the need for a reference object during the scan.
- 30 November 2023
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 94, 555-559
Open AccessA low-dose biplanar X-ray imager has RSA level precision in total knee arthroplasty
Background and purpose: The low radiation biplanar X-ray imager (EOS imaging, Paris, France) scans patients in a weight-bearing position, provides calibrated images, and limits radiation, an asset for serial radiostereometric analysis (RSA) studies. RSA in vivo precision values have not been published for this type of imaging system, thus the goal of this study was to assess the precision of RSA in vivo utilizing a low radiation biplanar imager.Patients and methods: At a mean of 5 years post-surgery (range 1.4–7.5 years), 15 total knee arthroplasty (TKA) participants (mean age 67 years at the time of imaging, 12 female, 3 male) with RSA markers implanted during index surgery were scanned twice at the same visit in the EOS imager. Precision of marker-based analysis was calculated by comparing the position of the implant relative to the underlying bone between the 2 examinations.Results: The 95% limit of precision was 0.11, 0.04, and 0.15 mm along the x, y, and z axes, respectively and 0.15°, 0.20°, and 0.14° around the same axes.Conclusion: This precision study has shown an in vivo RSA precision of ≤ 0.15 mm and ≤ 0.20°, well within published uniplanar values for conventional arthroplasty RSA, with the added benefit of weight-bearing imaging, a lower radiation dose, and without the need for a reference object during the scan.
- 28 February 2022
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 104 (8) , 700-708
The Effect of Patient Age and Surgical Appropriateness and Their Influence on Surgeon Recommendations for Primary TKA
Background: Rising total knee arthroplasty (TKA) rates in younger patients raises concern about appropriateness. We asked: are younger individuals who seek consultation for TKA less likely to be appropriate for and, controlling for appropriateness, more likely to be recommended for surgery? Methods: This cross-sectional study was nested within a prospective cohort study of knee osteoarthritis (OA) patients referred for TKA from 2014 to 2016 to centralized arthroplasty centers in Alberta, Canada. Pre-consultation, questionnaires assessed patients’ TKA appropriateness (need, based on knee symptoms and prior treatment; readiness/willingness to undergo TKA; health status; and expectations) and contextual factors (for example, employment). Post-consultation, surgeons confirmed study eligibility and reported their TKA recommendation. Using generalized estimating equations to control for clustering by surgeon, we assessed relationships between patient age (<50, 50 to 59, ≥60 years) and TKA appropriateness and receipt of a surgeon TKA recommendation. Results: Of 2,037 participants, 3.3% and 22.7% were <50 and 50 to 59 years of age, respectively, 58.7% were female, and 35.5% were employed. Compared with older participants, younger participants reported significantly worse knee symptoms, higher use of OA therapies, higher TKA readiness, and similar willingness, but had higher body mass index and were more likely to smoke and to consider the ability to participate in vigorous activities, for example, sports, as very important TKA outcomes. TKA was offered to 1,500 individuals (73.6% overall; 52.2%, 71.0%, and 75.4% of those <50, 50 to 59, and ≥60 years, respectively). In multivariate analyses, the odds of receiving a TKA recommendation were higher with greater TKA need and willingness, in nonsmokers, and in those who indicated that improved ability to go upstairs and to straighten the leg were very important TKA outcomes. Controlling for TKA appropriateness, patient age was not associated with surgeons’ TKA recommendations. Conclusions: Younger individuals with knee OA referred for TKA had similar or greater TKA need, readiness, and willingness than older individuals. Incorporation of TKA appropriateness criteria into TKA decision-making may facilitate consideration of TKA benefits and risks in a growing population of young, obese individuals with knee OA. Clinical Relevance: Younger people seeking TKA for knee OA had significant OA pain and disability despite recommended OA therapies, suggesting appropriateness for surgical consideration. However, they were significantly more likely to have morbid obesity, to smoke, and to consider return to vigorous activities, like sport, as important TKA outcomes. Whether the short- and longer-term risks of TKA are outweighed by the benefits is unclear and warrants additional research.
- 28 February 2022
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 104 (8) , 700-708
The Effect of Patient Age and Surgical Appropriateness and Their Influence on Surgeon Recommendations for Primary TKA
Background: Rising total knee arthroplasty (TKA) rates in younger patients raises concern about appropriateness. We asked: are younger individuals who seek consultation for TKA less likely to be appropriate for and, controlling for appropriateness, more likely to be recommended for surgery? Methods: This cross-sectional study was nested within a prospective cohort study of knee osteoarthritis (OA) patients referred for TKA from 2014 to 2016 to centralized arthroplasty centers in Alberta, Canada. Pre-consultation, questionnaires assessed patients’ TKA appropriateness (need, based on knee symptoms and prior treatment; readiness/willingness to undergo TKA; health status; and expectations) and contextual factors (for example, employment). Post-consultation, surgeons confirmed study eligibility and reported their TKA recommendation. Using generalized estimating equations to control for clustering by surgeon, we assessed relationships between patient age (<50, 50 to 59, ≥60 years) and TKA appropriateness and receipt of a surgeon TKA recommendation. Results: Of 2,037 participants, 3.3% and 22.7% were <50 and 50 to 59 years of age, respectively, 58.7% were female, and 35.5% were employed. Compared with older participants, younger participants reported significantly worse knee symptoms, higher use of OA therapies, higher TKA readiness, and similar willingness, but had higher body mass index and were more likely to smoke and to consider the ability to participate in vigorous activities, for example, sports, as very important TKA outcomes. TKA was offered to 1,500 individuals (73.6% overall; 52.2%, 71.0%, and 75.4% of those <50, 50 to 59, and ≥60 years, respectively). In multivariate analyses, the odds of receiving a TKA recommendation were higher with greater TKA need and willingness, in nonsmokers, and in those who indicated that improved ability to go upstairs and to straighten the leg were very important TKA outcomes. Controlling for TKA appropriateness, patient age was not associated with surgeons’ TKA recommendations. Conclusions: Younger individuals with knee OA referred for TKA had similar or greater TKA need, readiness, and willingness than older individuals. Incorporation of TKA appropriateness criteria into TKA decision-making may facilitate consideration of TKA benefits and risks in a growing population of young, obese individuals with knee OA. Clinical Relevance: Younger people seeking TKA for knee OA had significant OA pain and disability despite recommended OA therapies, suggesting appropriateness for surgical consideration. However, they were significantly more likely to have morbid obesity, to smoke, and to consider return to vigorous activities, like sport, as important TKA outcomes. Whether the short- and longer-term risks of TKA are outweighed by the benefits is unclear and warrants additional research.
- Open Access
Comorbidities do not limit improvement in pain and physical function after total knee arthroplasty in patients with knee osteoarthritis: the BEST-Knee prospective cohort study
Objective To assess the relationship between comorbidities and amount of improvement in pain and physical function in recipients of total knee arthroplasty (TKA) for knee osteoarthritis (OA). Design Prospective cohort study. Setting Two provincial central intake hip and knee centres in Alberta, Canada. Participants 1051 participants (278 in 6-minute walk test (6MWT) subset), ≥30 years of age with primary knee OA referred for consultation regarding elective primary TKA; assessed 1 month prior and 12 months after TKA. Primary and secondary outcome measures Pre-post TKA change in knee OA pain (Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)), physical function (Knee injury and Osteoarthritis Outcome Score (KOOS) Physical Function Short-Form) and 6MWT walking distance; and the reporting of an acceptable symptom state (Patient Acceptable Symptom State (PASS)) at 12 months after TKA. Results Mean participant age was 67 years (SD 8.8), 59% were female and 85% reported at least one comorbidity. Individuals with a higher number of comorbidities had worse pre-TKA and post-TKA scores for pain, physical function and 6MWT distance. At 12-month follow-up, mean changes in pain, function and 6MWT distance, and proportion reporting a PASS, were similar for those with and without comorbidities. In multivariable regression analysis, adjusted for potential confounders and clustering by surgeon, no specific comorbidities nor total number of comorbidities were associated with less improvement in pain, physical function or 6MWT distance at 12 months after TKA. Patients with diabetes (OR 0.64, 95% CI 0.44 to 0.94) and a higher number of lower extremity troublesome joints (OR 0.85, 95% CI 0.76 to 0.96) had lower odds of reporting a PASS. Conclusion For individuals with knee OA, comorbid conditions do not limit improvement in pain, physical function or walking ability after TKA, and most conditions do not impact achieving an acceptable symptom state.
Open AccessComorbidities do not limit improvement in pain and physical function after total knee arthroplasty in patients with knee osteoarthritis: the BEST-Knee prospective cohort study
Objective To assess the relationship between comorbidities and amount of improvement in pain and physical function in recipients of total knee arthroplasty (TKA) for knee osteoarthritis (OA). Design Prospective cohort study. Setting Two provincial central intake hip and knee centres in Alberta, Canada. Participants 1051 participants (278 in 6-minute walk test (6MWT) subset), ≥30 years of age with primary knee OA referred for consultation regarding elective primary TKA; assessed 1 month prior and 12 months after TKA. Primary and secondary outcome measures Pre-post TKA change in knee OA pain (Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)), physical function (Knee injury and Osteoarthritis Outcome Score (KOOS) Physical Function Short-Form) and 6MWT walking distance; and the reporting of an acceptable symptom state (Patient Acceptable Symptom State (PASS)) at 12 months after TKA. Results Mean participant age was 67 years (SD 8.8), 59% were female and 85% reported at least one comorbidity. Individuals with a higher number of comorbidities had worse pre-TKA and post-TKA scores for pain, physical function and 6MWT distance. At 12-month follow-up, mean changes in pain, function and 6MWT distance, and proportion reporting a PASS, were similar for those with and without comorbidities. In multivariable regression analysis, adjusted for potential confounders and clustering by surgeon, no specific comorbidities nor total number of comorbidities were associated with less improvement in pain, physical function or 6MWT distance at 12 months after TKA. Patients with diabetes (OR 0.64, 95% CI 0.44 to 0.94) and a higher number of lower extremity troublesome joints (OR 0.85, 95% CI 0.76 to 0.96) had lower odds of reporting a PASS. Conclusion For individuals with knee OA, comorbid conditions do not limit improvement in pain, physical function or walking ability after TKA, and most conditions do not impact achieving an acceptable symptom state.
- 11 January 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (6) , e22
Infection: The Final Frontier of Arthroplasty Management
- 11 January 2021
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (6) , e22
Infection: The Final Frontier of Arthroplasty Management