LBLars Eirik Bø

Lars Eirik Bø

*This is an algorithmically generated author record based on publicly available information.

Lars Eirik Bø has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Lesion Frequency Distribution Maps of Traumatic Axonal Injury on Early Magnetic Resonance Imaging After Moderate and Severe Traumatic Brain Injury and Associations to 12 Months Outcome

    by Anne-Mari Holte Flusund, Lars Eirik Bø, Ingerid Reinertsen, Ole Solheim, Toril Skandsen, Asta Håberg, Nada Andelic, Anne Vik, Kent Gøran Moen

    Traumatic axonal injury (TAI) is a common finding on magnetic resonance imaging (MRI) in patients with moderate–severe traumatic brain injury (TBI), and the burden of TAI is associated with outcome in this patient group. Lesion mapping offers a way to combine imaging findings from numerous individual patients into common lesion maps where the findings from a whole patient cohort can be assessed. The aim of this study was to evaluate the spatial distribution of TAI lesions on different MRI sequences and its associations to outcome with use of lesion mapping. Included prospectively were 269 patients (8–70 years) with moderate or severe TBI and MRI within six weeks after injury. The TAI lesions were evaluated and manually segmented on fluid-attenuated inversed recovery (FLAIR), diffusion weighted imaging (DWI), and either T2* gradient echo (T2*GRE) or susceptibility weighted imaging (SWI). The segmentations were registered to the Montreal Neurological Institute space and combined to lesion frequency distribution maps. Outcome was assessed with Glasgow Outcome Scale Extended (GOSE) score at 12 months. The frequency and distribution of TAI was assessed qualitatively by visual reading. Univariable associations to outcome were assessed qualitatively by visual reading and also quantitatively with use of voxel-based lesion-symptom mapping (VLSM). The highest frequency of TAI was found in the posterior half of corpus callosum. The frequency of TAI was higher in the frontal and temporal lobes than in the parietal and occipital lobes, and in the upper parts of the brainstem than in the lower. At the group level, all voxels in mesencephalon had TAI on FLAIR. The patients with poorest outcome (GOSE scores ≤4) had higher frequencies of TAI. On VLSM, poor outcome was associated with TAI lesions bilaterally in the splenium, the right side of tectum, tegmental mesencephalon, and pons. In conclusion, we found higher frequency of TAI in posterior corpus callosum, and TAI in splenium, mesencephalon, and pons were associated with poor outcome. If lesion frequency distribution maps containing outcome information based on imaging findings from numerous patients in the future can be compared with the imaging findings from individual patients, it would offer a new tool in the clinical workup and outcome prediction of the patient with TBI.


  • Open Access

    Is the anatomical distribution of low-grade gliomas linked to regions of gliogenesis?

    by Anne Jarstein Skjulsvik, Hans Kristian Bø, Asgeir Store Jakola, Erik Magnus Berntsen, Lars Eirik Bø, Ingerid Reinertsen, Kristin Smistad Myrmel, Kristin Sjåvik, Kristin Åberg, Thomas Berg, et al.

    Introduction: According to the stem cell theory, two neurogenic niches in the adult human brain may harbor cells that initiate the formation of gliomas: The larger subventricular zone (SVZ) and the subgranular zone (SGZ) in the hippocampus. We wanted to explore whether defining molecular markers in low-grade gliomas (LGG; WHO grade II) are related to distance to the neurogenic niches. Methods: Patients treated at two Norwegian university hospitals with population-based referral were included. Eligible patients had histopathological verified supratentorial low-grade glioma. IDH mutational status and 1p19q co-deletion status was retrospectively assessed. 159 patients were included, and semi-automatic tumor segmentation was done from pre-treatment T2-weighted (T2W) or Fluid-Attenuated Inversion Recovery (FLAIR) images. 3D maps showing the anatomical distribution of the tumors were then created for each of the three molecular subtypes (IDH mutated/1p19q co-deleted, IDH mutated and IDH wild-type). Both distance from tumor center and tumor border to the neurogenic niches were recorded. Results: In this population-based cohort of previously untreated low-grade gliomas, we found that low-grade gliomas are more often found closer to the SVZ than the SGZ, but IDH wild-type tumors are more often found near SGZ. Conclusion: Our study suggests that the stem cell origin of IDH wild-type and IDH mutated low-grade gliomas may be different.


  • Lack of transfer of skills after virtual reality simulator training with haptic feedback

    by Cecilie Våpenstad, Erlend Fagertun Hofstad, Lars Eirik Bø, Esther Kuhry, Gjermund Johnsen, Ronald Mårvik, Thomas Langø, Toril Nagelhus Hernes

    Background and objective: Virtual reality (VR) simulators enrich surgical training and offer training possibilities outside of the operating room (OR). In this study, we created a criterion-based training program on a VR simulator with haptic feedback and tested it by comparing the performances of a simulator group against a control group. Material and methods: Medical students with no experience in laparoscopy were randomly assigned to a simulator group or a control group. In the simulator group, the candidates trained until they reached predefined criteria on the LapSim® VR simulator (Surgical Science AB, Göteborg, Sweden) with haptic feedback (XitactTM IHP, Mentice AB, Göteborg, Sweden). All candidates performed a cholecystectomy on a porcine organ model in a box trainer (the clinical setting). The performances were video rated by two surgeons blinded to subject training status. Results: In total, 30 students performed the cholecystectomy and had their videos rated (N = 16 simulator group, N = 14 control group). The control group achieved better video rating scores than the simulator group (p < .05). Conclusions: The criterion-based training program did not transfer skills to the clinical setting. Poor mechanical performance of the simulated haptic feedback is believed to have resulted in a negative training effect.


  • Psychomotor skills assessment by motion analysis in minimally invasive surgery on an animal organ

    by Erlend Fagertun Hofstad, Cecilie Våpenstad, Lars Eirik Bø, Thomas Langø, Esther Kuhry, Ronald Mårvik

    Background: A high level of psychomotor skills is required to perform minimally invasive surgery (MIS) safely. To be able to measure these skills is important in the assessment of surgeons, as it enables constructive feedback during training. The aim of this study was to test the validity of an objective and automatic assessment method using motion analysis during a laparoscopic procedure on an animal organ. Material and methods: Experienced surgeons in laparoscopy (experts) and medical students (novices) performed a cholecystectomy on a porcine liver box model. The motions of the surgical tools were acquired and analyzed by 11 different motion-related metrics, i.e., a total of 19 metrics as eight of them were measured separately for each hand. We identified for which of the metrics the experts outperformed the novices. Results: In total, two experts and 28 novices were included. The experts achieved significantly better results for 13 of the 19 instrument motion metrics. Conclusions: Expert performance is characterized by a low time to complete the cholecystectomy, high bimanual dexterity (instrument coordination), a limited amount of movement and low measurement of motion smoothness of the dissection instrument, and relatively high usage of the grasper to optimize tissue positioning for dissection.


  • Open Access

    Versatile robotic probe calibration for position tracking in ultrasound imaging

    by Lars Eirik Bø, Erlend Fagertun Hofstad, Frank Lindseth, Toril A N Hernes

    Within the field of ultrasound-guided procedures, there are a number of methods for ultrasound probe calibration. While these methods are usually developed for a specific probe, they are in principle easily adapted to other probes. In practice, however, the adaptation often proves tedious and this is impractical in a research setting, where new probes are tested regularly. Therefore, we developed a method which can be applied to a large variety of probes without adaptation. The method used a robot arm to move a plastic sphere submerged in water through the ultrasound image plane, providing a slow and precise movement. The sphere was then segmented from the recorded ultrasound images using a MATLAB programme and the calibration matrix was computed based on this segmentation in combination with tracking information. The method was tested on three very different probes demonstrating both great versatility and high accuracy.


  • Open Access

    Registration of MR to Percutaneous Ultrasound of the Spine for Image-Guided Surgery

    by Lars Eirik Bø, Rafael Palomar, Tormod Selbekk, Ingerid Reinertsen


  • Limitations of haptic feedback devices on construct validity of the LapSim® virtual reality simulator

    by Cecilie Våpenstad, Erlend Fagertun Hofstad, Lars Eirik Bø, Magdalena Karolina Chmarra, Esther Kuhry, Gjermund Johnsen, Ronald Mårvik, Thomas Langø

    Surgeons performing laparoscopy need a high degree of psychomotor skills, which can be trained and assessed on virtual reality (VR) simulators. VR simulators simulate the surgical environment and assess psychomotor skills according to predefined parameters. This study aimed to validate a proficiency-based training setup that consisted of two tasks with predefined threshold values and handles with haptic feedback on the LapSim® VR simulator. The two tasks have been found to have construct validity in previous studies using handles without haptic feedback. The participants were divided into three groups: novices (0–50 laparoscopic procedures), intermediates (51–300 laparoscopic procedures), and experts (more than 300 procedures). It was assumed that psychomotor skills increase with experience. All participants conducted the tasks lifting and grasping and fine dissection 20 times each. Validity of the training setup was investigated by comparing the number of times each participant passed a predefined threshold level for a set of 19 parameters. Construct validity was established for one parameter; “misses on right side” on the lifting and grasping task, whereas the other 18 parameters did not show construct validity. The setup employed in this study failed to establish construct validity for more than one parameter. This indicates that the simulation of haptic feedback influences the training performance on laparoscopic simulators and is an important part of validating a training setup. A haptic device should generate haptic sensations in a realistic manner, without introducing frictional forces that are not inherent to laparoscopy.


  • Interactive development of a CT-based tissue model for ultrasound simulation

    by Sjur Urdson Gjerald, Reidar Brekken, Lars Eirik Bø, Torbjørn Hergum, Toril A. Nagelhus Hernes


  • Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting

    by Lars Eirik Bø, Håkon Olav Leira, Geir Arne Tangen, Erlend Fagertun Hofstad, Tore Amundsen, Thomas Langø

    Purpose: The authors have studied the accuracy and robustness of a prototype electromagnetic window field generator (WFG) in an interventional radiology suite with a robotic C-arm. The overall purpose is the development of guidance systems combining real-time imaging with tracking of flexible instruments for bronchoscopy, laparoscopic ultrasound, endoluminal surgery, endovascular therapy, and spinal surgery. Methods: The WFG has a torus shape, which facilitates x-ray imaging through its centre. The authors compared the performance of the WFG to that of a standard field generator (SFG) under the influence of the C-arm. Both accuracy and robustness measurements were performed with the C-arm in different positions and poses. Results: The system was deemed robust for both field generators, but the accuracy was notably influenced as the C-arm was moved into the electromagnetic field. The SFG provided a smaller root-mean-square position error but was more influenced by the C-arm than the WFG. The WFG also produced smaller maximum and variance of the error. Conclusions: Electromagnetic (EM) tracking with the new WFG during C-arm based fluoroscopy guidance seems to be a step forward, and with a correction scheme implemented it should be feasible.


  • Navigated Bronchoscopy With Electromagnetic Tracking—Cone Beam Computed Tomography Influence on Tracking and Registration Accuracy

    by Håkon Olav Leira, Erlend Fagertun Hofstad, Lars Eirik Bø, Thomas Langø, Tore Amundsen

    Current image guidance systems for bronchoscopy are limited to the diagnosis of small tumors and placing fiducials for radiation therapy and surgery. Ideally, a navigation system should be useable for the range of bronchoscopic procedures, including therapy with concurrent radiology imaging for control. As most guidance systems rely on electromagnetic (EM) fields, it is advised to leave the C-arm mounted fluoroscopy unit outside the operating field during navigation. We have assessed the accuracy of our research navigation platform, containing an EM field generator and a C-arm fluoroscopy unit. We have simulated a regular bronchoscopy session with an initial image-to-patient registration procedure, and a subsequent bronchoscopy with the C-arm inside the EM field. The registration accuracy was significantly influenced, introducing an error that may be carried through to the bronchoscopy procedure. During the bronchoscopy session, the C-arm caused a wave drift in the tracking positions and distorted the EM field, causing a translation error up to 22 mm. Even by averaging out the drift, there was a systematic shift in the x, y, and z positions. The errors were more evident in some C-arm positions and seem to be linked more to the electrical current in the fluoroscopy unit than the metallic C-arm itself. A fluoroscopy unit may be used during a navigation procedure, but care must be taken. To enable real-time navigation, the C-arm could be removed sufficiently from the EM tracking field or correction schemes must be implemented to compensate for the distortions.