YNYoshie Nomoto

Yoshie Nomoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yoshie Nomoto has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reply to the comments on ‘Utility of underwater endoscopic mucosal resection combined with a protruding anchor by saline injection for superficial non-ampullary duodenal tumors: a retrospective study in Japan'

    by Hironori Yamamoto, Yoshie Nomoto, Satoshi Shinozaki, Yoshimasa Miura, Hiroyuki Osawa

    Reply to the comments on ‘Utility of underwater endoscopic mucosal resection combined with a protruding anchor by saline injection for superficial non-ampullary duodenal tumors: a retrospective study in Japan


  • Open Access

    Utility of underwater endoscopic mucosal resection combined with a protruding anchor by saline injection for superficial non-ampullary duodenal tumors: a retrospective study in Japan

    by Yoshie Nomoto, Satoshi Shinozaki, Yoshimasa Miura, Hiroyuki Osawa, Yuji Ino, Tomonori Yano, Nikolaos Lazaridis, Hironori Yamamoto

    Utility of underwater endoscopic mucosal resection combined with a protruding anchor by saline injection for superficial non-ampullary duodenal tumors: a retrospective study in Japan


  • Open Access

    Combination of the saline-immersion technique and a new thin therapeutic endoscope for endoscopic submucosal dissection of a duodenal subepithelial tumor

    by Kosei Hashimoto, Hisashi Fukuda, Toshihiro Fujinuma, Yoshie Nomoto, Edward J. Despott, Hironori Yamamoto

    Few cases of endoscopic submucosal dissection (ESD) for duodenal subepithelial tumors (SELs) have been reported, particularly in the challenging area of the duodenal bulb just behind the pyloric ring. This region presents a narrow working space, and the thin submucosal layer complicates dissection between the SEL and the muscular layer. The recent introduction of a new thin therapeutic endoscope (EG-840TP; Fujifilm, Tokyo, Japan) holds promise for ESD in such confined spaces [1] [2] [3] [4]. Despite its small diameter of 7.9 mm, this endoscope is equipped with a 3.2-mm accessory channel, a waterjet function, and an extended down angle of up to 160° ([Fig. 1], [Fig. 2]), making it well suited for therapeutic procedures [1]. We successfully performed total excision of a duodenal SEL with complete closure of the mucosal defect using this new thin endoscope and the saline-immersion technique for the ESD procedure ([Video 1]). The patient was a 49-year-old man with an enlarging SEL in the duodenal bulb. Endoscopic ultrasound (EUS) revealed a 20-mm isoechoic mass originating from the second layer, with hypoechoic glandular structures inside, suggesting the possibility of an ectopic pancreas. Given the preservation of the third layer, ESD was deemed feasible. Although EUS-guided fine-needle aspiration (EUS-FNA) was considered, ESD was recommended owing to the diagnostic uncertainty and the potential need for long-term follow-up. We employed a strategy to circumferentially incise the midportion of the elevation and dissect out the SEL along with the mucosa at the apex ([Fig. 3]). Using the thin therapeutic endoscope fitted with a prototype transparent hood with a small-caliber tip, we easily approached the tumor, created a pocket from the oral side, and completed the resection within 40 minutes, with no adverse events occurring. The mucosal defect was easily closed with ordinary clips because enough room was left in the residual mucosa for closure. Pathological results confirmed the lesion to be Brunner’s gland hyperplasia measuring 25 × 20 mm. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AD Article published online: 14 January 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany


  • Open Access

    Continuous low-pressure saline perfusion for gastric endoscopic submucosal dissection

    by Yuji Ino, Hisashi Fukuda, Takashi Ueno, Hiroki Hayashi, Yoshie Nomoto, Haruo Takahashi, Hironori Yamamoto

    A method for conducting endoscopic submucosal dissection (ESD) by employing saline infusions in place of carbon dioxide has been reported [1]. This method effectively enhances the endoscopic visual field and maintains optimal intragastric pressure [2] [3]. Nevertheless, several limitations are noteworthy. First, blood admixture from bleeding events can significantly compromise visibility. Addressing this issue necessitates removing the incision device to suction the contaminated physiological saline solution. Second, potential bubble formation may obstruct the visual field by getting into the tip attachment. Consequently, operators are required to intermittently activate the foot pump of the water jet to disperse these bubbles. To mitigate these problems, we employ continuous low-pressure saline perfusion. After inserting the nasogastric tube and securing it to the gastric wall with clips ([Fig. 1]), an assistant operates the pedal of the water jet pump to continuously irrigate the gastric cavity with low-pressure physiological saline solution ([Fig. 2]). The advantages of this technique are described in the following. Sustained irrigation of the interior of the tip attachment with positive pressure facilitates bubble expulsion, thereby ensuring uninterrupted clarity of the visual field ([Fig. 3], [Fig. 4], [Fig. 5]). Moreover, operators can allocate their attention to manipulating the high-frequency device pedal without needing to engage the foot pedal of the water jet ([Video 1]). Furthermore, the availability of physiological saline solution retrieval from the nasogastric tube underscores its potential to mitigate hypernatremia and water intoxication, thereby enhancing overall procedural safety [4]. Apart from the standard ESD equipment, the sole requisites for this approach are physiological saline solution and a gastric tube, rendering it remarkably cost-effective. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AZ Article published online: 18 October 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    A loop cutter is an ideal gripper for endoscopic removal of press-through-package sheets

    by Yuji Ino, Masafumi Kitamura, Yoshie Nomoto, Chihiro Iwashita, Yoshimasa Miura, Tomonori Yano, Hironori Yamamoto

    A press-through package (PTP) sheet is sometimes accidentally swallowed [1]. PTP sheets have sharp edges ([Fig. 1]) and may cause mucosal damage and/or perforation to the gastrointestinal tract [2] [3]. Thus, ingested PTP sheets should be removed endoscopically as soon as possible. Several methods have been reported using hoods and covers to prevent mucosal damage during removal [4] [5]. However, a firm grip on the PTP sheet is necessary for successful removal. Grasping forceps or a snare are commonly used as grasping devices but can often fail because the PTP is slippery with saliva and the working space is insufficient for snaring. To address this, we used a Loop Cutter (FS-5L-1; Olympus, Tokyo, Japan), whose teeth can penetrate the PTP plastic sheet to secure a firm grip. The Loop Cutter’s strong grip allows the PTP to be easily removed. To evaluate the gripping force of various devices, we attached a PTP sheet to the tip of a spring scale ([Fig. 2]). The gripping force was measured until the PTP was detached from the grasping device. The mean gripping force of each thirty times was 498 g in Standard Fenestrated Biopsy Forceps (FB-25K-1, Olympus), 404 g in the Radial Jaw 4 Pediatric Biopsy Forceps (M00513440; Boston Scientific, Marlborough, Massachusetts, USA), 37 g in the Rat Tooth with Alligator Jaw Grasping Forceps (FG-47L-1; Olympus), and 1440 g in the Loop Cutter ([Fig. 3]). A 70-year-old woman presented to our hospital complaining of a sore throat after accidentally ingesting PTP sheets. A computed tomography (CT) scan showed the PTP location in the esophagus ([Fig. 4]). The second case was a 63-year-old man with dementia. PTP was found in the stomach along with a large amount of food residue. The PTP sheets were successfully and safely removed endoscopically in both cases by grasping the PTP sheet using a Loop Cutter ([Fig. 5], [Video 1]). Video 1 A Loop Cutter is an ideal gripper for endoscopic removal of press-through packages. Endoscopy_UCTN_Code_TTT_1AO_2AL Article published online: 13 July 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Open Access

    Appropriate Color Enhancement Settings for Blue Laser Imaging Facilitates the Diagnosis of Early Gastric Cancer with High Color Contrast

    by Yuji Hiraoka, Yoshimasa Miura, Hiroyuki Osawa, Yoshie Nomoto, Haruo Takahashi, Masato Tsunoda, Manabu Nagayama, Takashi Ueno, Alan Kawarai Lefor, Hironori Yamamoto

    Hiraoka Y, et al. J Gastric Cancer. 2021 Jun;21(2):142-154. https://doi.org/10.5230/jgc.2021.21.e13