JKJunhwan Kwon

Junhwan Kwon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Junhwan Kwon has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A new single-sagittal-plane deep learning approach for continuous bladder volume monitoring: a feasibility study

    by Junhwan Kwon, Ilseob Song, Sangeun Park, Jongsoo Lee, Yangmo Yoo

    Conventional ultrasound-based bladder volumetry multiplies three orthogonal diameters and applies a heuristic shape coefficient. This approach requires near-simultaneous transverse and sagittal imaging and is vulnerable to interplane misregistration and coefficient-dependent bias. This study evaluated whether a single sagittal B-mode image can provide accurate, patient-specific bladder volume estimation by leveraging sagittal morphology, perivesical echotexture, and latent image features associated with overall bladder geometry. In this Institutional Review Board-approved, single-center study, participants were scanned in the supine position, and bladder volume was referenced to immediate Foley catheter drainage. Segmentation masks were independently annotated by two sonographers and adjudicated by a urologist. Maximum sagittal length was extracted using OpenCV and included as an auxiliary scalar input. A single-stage deep learning model was developed that receives one sagittal B-mode image and its expert-annotated segmentation mask as input. The model used a lightweight convolutional neural network backbone with integrated self-attention to capture global echotextural cues. Performance on a held-out test set (n=53) was assessed using linear regression, Bland-Altman analysis, mean absolute error, and mean absolute percentage error. The model demonstrated a strong correlation with catheter-derived volumes (R²=0.87). Bland-Altman analysis showed a mean bias of -3.96±48.44 mL, with limits of agreement from -98.90 to +90.98 mL. Stratified error analysis showed a mean absolute error of 14.15 mL for volumes of 0-100 mL and a mean absolute percentage error of 16.64% for volumes ≥100 mL. Attention maps emphasized the bladder wall and perivesical soft tissues, suggesting reliance on contextual echotexture. A deep learning framework using a single sagittal plane estimated bladder volume with accuracy approaching that of two-plane techniques while simplifying image acquisition and eliminating reliance on fixed shape coefficients.

  • Human Perception Mechanism based CNN-RNN Framework for Dimensional Emotion Recognition

    by Kyeong Teak Oh, Junhwan Kwon, Oyun Kwon, Jaesuk Kim, Hee Cheol Kang, Sun K. Yoo

    In this paper, we propose human perception mechanism based CNN-RNN based approach to recognize dimensional emotion using Aff-Wild dataset. The proposed model recognizes dimensional expression through two steps. First, motivated by the human facial expression perception mechanism, the patches were extracted based on facial key points. Second, the facial expression was classified based on CNN-RNN model using extracted patches. The mean concordance correlation coefficient (CCC) of the proposed model is 0.322, indicating superior performance compared to the original CNN-RNN model, which achieved a mean CCC of 0.283.

  • Open Access

    Non-Contact Respiration Rate Measurement From Thermal Images Using Multi-Resolution Window and Phase-Sensitive Processing

    by Jiwon Choi, Kyeong-Taek Oh, Oyun Kwon, Jun Hwan Kwon, Jeongmin Kim, Sun K. Yoo

    This paper presents a method for measuring human respiration using a thermal camera. Respiration, being a commonly monitored biomedical signal, has traditionally been measured using contact-based methods, which can cause discomfort and skin damage to patients. With the need for non-contact respiration measurement to prevent infection in the post-COVID-19 era, previous studies encountered challenges in applying non-contact methods in clinical settings due to the distortion of respiratory signals caused by high-dimensional filters. To address these limitations, this paper proposes the use of a thermal camera for non-contact data acquisition and accurate respiratory rate (RR) prediction, even in the presence of noisy respiratory signals. The proposed method leverages a multi-resolution window (MW) and phase-sensitive (PS) processing. Specifically, thermal images are captured using an infrared (IR) thermal camera, and the respiratory signal is extracted from the series of thermal images. The MW method, employing three windows of different sizes in the time domain, is then applied to the extracted respiratory signal. The resulting MW output is transformed into the frequency domain using the Fourier synchro-squeezed transform (FSST). The PS processing involves the multiplication of the converted signal, which is in polar form after a phasor operation. The processed data is utilized to train two bidirectional Long Short-Term Memory (bi-LSTM) networks, and the RR is calculated based on the trained model. To validate the proposed model, a total of 37 surgical patients were involved, with 20 patients used for training and 17 patients for testing. Six deep learning models were designed and their performances were compared. The results indicate that the proposed model outperformed the others, achieving a test classification accuracy of 98.06% and a root mean square error (RMSE) of 0.381. Despite being non-invasive and non-contact, our method demonstrates high accuracy in predicting RR, attributed to the utilization of MW and PS processing. Therefore, it holds potential for application in clinical environments, such as monitoring patients with pulmonary diseases or in intensive care units (ICUs).


  • Open Access

    Real-time Pilates Posture Recognition System Using Deep Learning Model

    by Hayoung Kim, Kyeong Teak Oh, Jaesuk Kim, Oyun Kwon, Junhwan Kwon, Jiwon Choi, Sun K. Yoo

    As the pandemic situation continues, many people exercise at home. Mat Pilates is a popular workout and effective core strengthening. Although many researchers have conducted pose recognition studies for exercise posture correction, the study on Pilates exercise is only one case on static images. Therefore, for the purpose of exercise monitoring, we propose a real-time Pilates posture recognition system on a smartphone for exercise monitoring. We aimed to recognize 8 Pilates exercises—Bridge, Head roll-up, Hundred, Roll-up, Teaser, Plank, Thigh stretch, and Swan. First, the Blazepose model is used to extract body joint features. Then, we designed a deep neural network model that recognizes Pilates based on the extracted body features. It also measures the number of workouts, duration, and similarity to experts in video sequences. The precision, recall, and f1-score of the posture recognition model are 0.90, 0.87, and 0.88, respectively. The introduced application is expected to be used for exercise management at home.


  • Open Access

    Breathing-Associated Facial Region Segmentation for Thermal Camera-Based Indirect Breathing Monitoring

    by Junhwan Kwon, Oyun Kwon, Kyeong Taek Oh, Jeongmin Kim, Sun K. Yoo

    (Objective)Breathing can be measured in a non-contact method using a thermal camera. The objective of this study investigates non-contact breathing measurements using thermal cameras, which have previously been limited to measuring the nostril only from the front where it is clearly visible. The previous method is challenging to use for other angles and frontal views, where the nostril is not well-represented. In this paper, we defined a new region called the breathing-associated-facial-region (BAFR) that reflects the physiological characteristics of breathing, and extract breathing signals from views of 45 and 90 degrees, including the frontal view where the nostril is not clearly visible. (Methods) Experiments were conducted on fifteen healthy subjects in different views, including frontal with and without nostril, 45-degree, and 90-degree views. A thermal camera (A655sc model, FLIR systems) was used for non-contact measurement, and biopac (MP150, Biopac-systems-Inc) was used as a chest breathing reference. (Results) The results showed that the proposed algorithm could extract stable breathing signals at various angles and views, achieving an average breathing cycle accuracy of 90.9% when applied compared to 65.6% without proposed algorithm. The average correlation value increases from 0.587 to 0.885. (Conclusion)The proposed algorithm can be monitored in a variety of environments and extract the BAFR at diverse angles and views. (Clinical Impact)The proposed algorithm shows the feasibility of non-contact breathing reliable monitoring that versatile and accurate than previous methods. The proposed algorithm could be used to monitor breathing in various clinical environments, including isolated wards, operation rooms, and intensive care units with high infection risks.


  • Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia

    by Jeongmin Kim, Jun Hwan Kwon, Eungjin Kim, Sun Kook Yoo, Cheung-Soo Shin

    We aimed to evaluate changes in respiratory pattern after sedation by simultaneously applying a respiratory volume monitor (ExSpiron1Xi, RVM) and infrared thermography (IRT) to patients undergoing spinal anesthesia during endoscopic urologic surgeries. After spinal anesthesia was performed, the patient was placed in a lithotomy position for surgery. Then, we established the baseline of the RVM, and started monitoring the mouth and nose with the infrared camera. SpO2 was continuously measured throughout these processes. Once the baseline was set, 0.05 mg/kg midazolam was administered for sedation. Apnea was defined as cessation of airflow for ≥ 10 s with respiratory rate of < 6 breaths/min; hypopnea was defined as a decrease in oxygen hemoglobin of > 4%, compared to baseline. We measured the time at which apnea was detected by IRT, the time at which hypopnea was detected by RVM, and the time at which hypoxia was detected by SpO2. Twenty patients (age: 68.9 ± 11.2 years, body mass index: 24.2 ± 2.6 kg/min2) completed the study. Before sedation, the baseline correlation coefficient of respiratory rate detection between RVM and IRT was 0.866. After midazolam administration, apnea was detected in all subjects within the first 5 min by IRT; the median time required to detect apnea was 102.5 [interquartile range (IQR) 25–75%: 80–155] s. Hypopnea was detected in all subjects within the first 5 min by RVM: the median time required to detect hypopnea was 142.5 (IQR 115–185.2) s. The median time required for SpO2 to decrease > 4% from baseline was 160 (IQR 125–205) s. Our results suggest that IRT can be useful for rapid detection of respiratory changes in patients undergoing sedation following spinal anesthesia for endoscopic urologic procedures.