Kyeong Taek Oh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kyeong Taek Oh has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Sun Kook Yoo
Department of Medical Engineering, Yonsei University College of Medicine, Seoul, Korea
4 shared publications - Jeongmin Kim
Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Korea
3 shared publications - Jiwon Choi
Department of Medical Engineering College of Medicine Yonsei University Seoul Republic of Korea
3 shared publications - Junhwan Kwon
Department of Medical Engineering, Yonsei University College of Medicine, Seoul, South Korea
2 shared publications - Oyun Kwon
Yonsei University College of Medicine,Department of Biomedical Engineering,Seoul,Korea
2 shared publications Byeong‐Sun Park
Department of Medical Engineering College of Medicine Yonsei University Seoul Republic of Korea
1 shared publication
Latest Publications
- Open Access
Robotic Palpation for Spatiotemporal Arterial Pulse Quantification and Mapping Using Multilevel Microdome‐Based Soft Pressure Sensors
Humanoid robots have advanced capabilities through physical and physiological examinations, but their reliance on visual information limits biological‐object assessment, underscoring the need for tactile perception. Current tactile systems primarily detect basic contact using a limited number of sensors, hindering accurate soft‐object localization and physiological signal acquisition. This study introduces a robotic palpation strategy by utilizing a fully soft‐tactile‐sensor‐integrated humanoid hand for real‐time spatiotemporal arterial pulse diagnosis. A facile fabrication technique produces an artificial pressure‐sensitive layer with multilevel microscale dome‐on‐dome (DoD) structures using eutectic gallium‐indium, achieving high‐density (>72 500 ea/cm 2 ) and large‐area (wafer‐scale >98% yield) fabrication. The DoD‐integrated pressure sensor exhibits a 7.5 × enhanced dynamic response compared with a single‐level sensing layer, enabling the simultaneous detection of subtle vibrations under high‐pressure conditions. The artificial skin is integrated into a humanoid hand, featuring 81 sensors on the fingertip and a total of 801 sensors on the hand, allowing real‐time spatiotemporal arterial pulse quantification and mapping.
Open AccessRobotic Palpation for Spatiotemporal Arterial Pulse Quantification and Mapping Using Multilevel Microdome‐Based Soft Pressure Sensors
Humanoid robots have advanced capabilities through physical and physiological examinations, but their reliance on visual information limits biological‐object assessment, underscoring the need for tactile perception. Current tactile systems primarily detect basic contact using a limited number of sensors, hindering accurate soft‐object localization and physiological signal acquisition. This study introduces a robotic palpation strategy by utilizing a fully soft‐tactile‐sensor‐integrated humanoid hand for real‐time spatiotemporal arterial pulse diagnosis. A facile fabrication technique produces an artificial pressure‐sensitive layer with multilevel microscale dome‐on‐dome (DoD) structures using eutectic gallium‐indium, achieving high‐density (>72 500 ea/cm 2 ) and large‐area (wafer‐scale >98% yield) fabrication. The DoD‐integrated pressure sensor exhibits a 7.5 × enhanced dynamic response compared with a single‐level sensing layer, enabling the simultaneous detection of subtle vibrations under high‐pressure conditions. The artificial skin is integrated into a humanoid hand, featuring 81 sensors on the fingertip and a total of 801 sensors on the hand, allowing real‐time spatiotemporal arterial pulse quantification and mapping.
- 9 July 2026
- Published by Elsevier in Health Policy
- Vol. 172, 105694
Comparative Analysis of In Vitro Diagnostic Medical Devices and Laboratory-Developed Tests: Insights from global regulation
- 9 July 2026
- Published by Elsevier in Health Policy
- Vol. 172, 105694
Comparative Analysis of In Vitro Diagnostic Medical Devices and Laboratory-Developed Tests: Insights from global regulation
- Open Access
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 112706-112718
Non-Contact Respiration Rate Measurement From Thermal Images Using Multi-Resolution Window and Phase-Sensitive Processing
This paper presents a method for measuring human respiration using a thermal camera. Respiration, being a commonly monitored biomedical signal, has traditionally been measured using contact-based methods, which can cause discomfort and skin damage to patients. With the need for non-contact respiration measurement to prevent infection in the post-COVID-19 era, previous studies encountered challenges in applying non-contact methods in clinical settings due to the distortion of respiratory signals caused by high-dimensional filters. To address these limitations, this paper proposes the use of a thermal camera for non-contact data acquisition and accurate respiratory rate (RR) prediction, even in the presence of noisy respiratory signals. The proposed method leverages a multi-resolution window (MW) and phase-sensitive (PS) processing. Specifically, thermal images are captured using an infrared (IR) thermal camera, and the respiratory signal is extracted from the series of thermal images. The MW method, employing three windows of different sizes in the time domain, is then applied to the extracted respiratory signal. The resulting MW output is transformed into the frequency domain using the Fourier synchro-squeezed transform (FSST). The PS processing involves the multiplication of the converted signal, which is in polar form after a phasor operation. The processed data is utilized to train two bidirectional Long Short-Term Memory (bi-LSTM) networks, and the RR is calculated based on the trained model. To validate the proposed model, a total of 37 surgical patients were involved, with 20 patients used for training and 17 patients for testing. Six deep learning models were designed and their performances were compared. The results indicate that the proposed model outperformed the others, achieving a test classification accuracy of 98.06% and a root mean square error (RMSE) of 0.381. Despite being non-invasive and non-contact, our method demonstrates high accuracy in predicting RR, attributed to the utilization of MW and PS processing. Therefore, it holds potential for application in clinical environments, such as monitoring patients with pulmonary diseases or in intensive care units (ICUs).
- 4 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 112706-112718
Open AccessNon-Contact Respiration Rate Measurement From Thermal Images Using Multi-Resolution Window and Phase-Sensitive Processing
This paper presents a method for measuring human respiration using a thermal camera. Respiration, being a commonly monitored biomedical signal, has traditionally been measured using contact-based methods, which can cause discomfort and skin damage to patients. With the need for non-contact respiration measurement to prevent infection in the post-COVID-19 era, previous studies encountered challenges in applying non-contact methods in clinical settings due to the distortion of respiratory signals caused by high-dimensional filters. To address these limitations, this paper proposes the use of a thermal camera for non-contact data acquisition and accurate respiratory rate (RR) prediction, even in the presence of noisy respiratory signals. The proposed method leverages a multi-resolution window (MW) and phase-sensitive (PS) processing. Specifically, thermal images are captured using an infrared (IR) thermal camera, and the respiratory signal is extracted from the series of thermal images. The MW method, employing three windows of different sizes in the time domain, is then applied to the extracted respiratory signal. The resulting MW output is transformed into the frequency domain using the Fourier synchro-squeezed transform (FSST). The PS processing involves the multiplication of the converted signal, which is in polar form after a phasor operation. The processed data is utilized to train two bidirectional Long Short-Term Memory (bi-LSTM) networks, and the RR is calculated based on the trained model. To validate the proposed model, a total of 37 surgical patients were involved, with 20 patients used for training and 17 patients for testing. Six deep learning models were designed and their performances were compared. The results indicate that the proposed model outperformed the others, achieving a test classification accuracy of 98.06% and a root mean square error (RMSE) of 0.381. Despite being non-invasive and non-contact, our method demonstrates high accuracy in predicting RR, attributed to the utilization of MW and PS processing. Therefore, it holds potential for application in clinical environments, such as monitoring patients with pulmonary diseases or in intensive care units (ICUs).
- Open Access
- 17 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 11, 505-514
Breathing-Associated Facial Region Segmentation for Thermal Camera-Based Indirect Breathing Monitoring
(Objective)Breathing can be measured in a non-contact method using a thermal camera. The objective of this study investigates non-contact breathing measurements using thermal cameras, which have previously been limited to measuring the nostril only from the front where it is clearly visible. The previous method is challenging to use for other angles and frontal views, where the nostril is not well-represented. In this paper, we defined a new region called the breathing-associated-facial-region (BAFR) that reflects the physiological characteristics of breathing, and extract breathing signals from views of 45 and 90 degrees, including the frontal view where the nostril is not clearly visible. (Methods) Experiments were conducted on fifteen healthy subjects in different views, including frontal with and without nostril, 45-degree, and 90-degree views. A thermal camera (A655sc model, FLIR systems) was used for non-contact measurement, and biopac (MP150, Biopac-systems-Inc) was used as a chest breathing reference. (Results) The results showed that the proposed algorithm could extract stable breathing signals at various angles and views, achieving an average breathing cycle accuracy of 90.9% when applied compared to 65.6% without proposed algorithm. The average correlation value increases from 0.587 to 0.885. (Conclusion)The proposed algorithm can be monitored in a variety of environments and extract the BAFR at diverse angles and views. (Clinical Impact)The proposed algorithm shows the feasibility of non-contact breathing reliable monitoring that versatile and accurate than previous methods. The proposed algorithm could be used to monitor breathing in various clinical environments, including isolated wards, operation rooms, and intensive care units with high infection risks.
- 17 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 11, 505-514
Open AccessBreathing-Associated Facial Region Segmentation for Thermal Camera-Based Indirect Breathing Monitoring
(Objective)Breathing can be measured in a non-contact method using a thermal camera. The objective of this study investigates non-contact breathing measurements using thermal cameras, which have previously been limited to measuring the nostril only from the front where it is clearly visible. The previous method is challenging to use for other angles and frontal views, where the nostril is not well-represented. In this paper, we defined a new region called the breathing-associated-facial-region (BAFR) that reflects the physiological characteristics of breathing, and extract breathing signals from views of 45 and 90 degrees, including the frontal view where the nostril is not clearly visible. (Methods) Experiments were conducted on fifteen healthy subjects in different views, including frontal with and without nostril, 45-degree, and 90-degree views. A thermal camera (A655sc model, FLIR systems) was used for non-contact measurement, and biopac (MP150, Biopac-systems-Inc) was used as a chest breathing reference. (Results) The results showed that the proposed algorithm could extract stable breathing signals at various angles and views, achieving an average breathing cycle accuracy of 90.9% when applied compared to 65.6% without proposed algorithm. The average correlation value increases from 0.587 to 0.885. (Conclusion)The proposed algorithm can be monitored in a variety of environments and extract the BAFR at diverse angles and views. (Clinical Impact)The proposed algorithm shows the feasibility of non-contact breathing reliable monitoring that versatile and accurate than previous methods. The proposed algorithm could be used to monitor breathing in various clinical environments, including isolated wards, operation rooms, and intensive care units with high infection risks.
- Open Access
- 4 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 70001-70010
Mattress Sensor-Based Respiration Rate Estimation Using Unsupervised Clustering
In this paper, a method is proposed to measure the human respiration rate using a mattress sensor. An unsupervised clustering method, combined with a cluster selection algorithm, was used to measure the respiration rate. The volume change of the upper body during the breathing process was indicated by the change of pressure on the mattress sensor and the respiration waveform was estimated by measuring the pressure change. The measured pressure changes were separated into respiratory-related clusters and noise using the clustering method. Finally, a cluster selection algorithm was used to find the combination of clusters that best represented the respiration. The proposed method was compared with other methods. The results showed that the proposed method had a mean Pearson correlation coefficient of the proposed method was 0.8746, which was the highest among all the methods. The difference between these methods was statistically significant (p<0.001). In addition, a regression analysis was performed to measure the accuracy of the respiration rate. The results showed that the proposed method calculated the respiratory rate most accurately.
- 4 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 70001-70010
Open AccessMattress Sensor-Based Respiration Rate Estimation Using Unsupervised Clustering
In this paper, a method is proposed to measure the human respiration rate using a mattress sensor. An unsupervised clustering method, combined with a cluster selection algorithm, was used to measure the respiration rate. The volume change of the upper body during the breathing process was indicated by the change of pressure on the mattress sensor and the respiration waveform was estimated by measuring the pressure change. The measured pressure changes were separated into respiratory-related clusters and noise using the clustering method. Finally, a cluster selection algorithm was used to find the combination of clusters that best represented the respiration. The proposed method was compared with other methods. The results showed that the proposed method had a mean Pearson correlation coefficient of the proposed method was 0.8746, which was the highest among all the methods. The difference between these methods was statistically significant (p<0.001). In addition, a regression analysis was performed to measure the accuracy of the respiration rate. The results showed that the proposed method calculated the respiratory rate most accurately.
- 2 August 2021
- Published by SAGE Publications in Journal of Parkinson’s Disease
- Vol. 11 (3) , 1247-1256
Postganglionic Sudomotor Dysfunction and Brain Glucose Hypometabolism in Patients with Multiple System Atrophy
Background: Sudomotor dysfunction is common in patients with multiple system atrophy (MSA). Postganglionic sudomotor dysfunction in MSA, which can be assessed using quantitative sudomotor axon reflex testing (QSART), results from the degeneration of preganglionic sympathetic neurons and direct loss of postganglionic fibers. Objective: We investigate whether abnormal QSART responses in patients with MSA are associated with disease severity. Methods: In this retrospective study, patients with probable MSA who underwent both 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT) and autonomic function tests were included. Autonomic function test results were integrated divided into three sub-scores, including sudomotor, cardiovagal, and adrenergic sub-scores. The sudomotor sub-score represented postganglionic sudomotor function. Unified Multiple System Atrophy Rating Scale (UMSARS) Part I, Part II, and sum of Part I and II scores (Part I + II) to reflect disease severity and 18F-FDG-PET/CT results were collected. Results: Of 74 patients with MSA, 62.2%demonstrated abnormal QSART results. The UMSARS Part I + II score was significantly higher in the abnormal QSART group than in the normal QSART group (p = 0.037). In the regression analysis, both UMSARS Part I (β= 1.185, p = 0.013) and Part II (β= 1.266, p = 0.021) scores were significantly associated with the sudomotor sub-score. On 18F-FDG-PET/CT, the abnormal QSART group exhibited more severely decreased metabolic activity in the cerebellum and basal ganglia in patients with MSA-P and MSA-C, respectively. The sudomotor sub-score was significantly associated with regional metabolism in these areas. Conclusion: Patients with MSA and postganglionic sudomotor dysfunction may have worse disease severity and greater neuropathological burden than those without.
- 2 August 2021
- Published by SAGE Publications in Journal of Parkinson’s Disease
- Vol. 11 (3) , 1247-1256
Postganglionic Sudomotor Dysfunction and Brain Glucose Hypometabolism in Patients with Multiple System Atrophy
Background: Sudomotor dysfunction is common in patients with multiple system atrophy (MSA). Postganglionic sudomotor dysfunction in MSA, which can be assessed using quantitative sudomotor axon reflex testing (QSART), results from the degeneration of preganglionic sympathetic neurons and direct loss of postganglionic fibers. Objective: We investigate whether abnormal QSART responses in patients with MSA are associated with disease severity. Methods: In this retrospective study, patients with probable MSA who underwent both 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT) and autonomic function tests were included. Autonomic function test results were integrated divided into three sub-scores, including sudomotor, cardiovagal, and adrenergic sub-scores. The sudomotor sub-score represented postganglionic sudomotor function. Unified Multiple System Atrophy Rating Scale (UMSARS) Part I, Part II, and sum of Part I and II scores (Part I + II) to reflect disease severity and 18F-FDG-PET/CT results were collected. Results: Of 74 patients with MSA, 62.2%demonstrated abnormal QSART results. The UMSARS Part I + II score was significantly higher in the abnormal QSART group than in the normal QSART group (p = 0.037). In the regression analysis, both UMSARS Part I (β= 1.185, p = 0.013) and Part II (β= 1.266, p = 0.021) scores were significantly associated with the sudomotor sub-score. On 18F-FDG-PET/CT, the abnormal QSART group exhibited more severely decreased metabolic activity in the cerebellum and basal ganglia in patients with MSA-P and MSA-C, respectively. The sudomotor sub-score was significantly associated with regional metabolism in these areas. Conclusion: Patients with MSA and postganglionic sudomotor dysfunction may have worse disease severity and greater neuropathological burden than those without.