NSNur Hidayah Shahemi

Nur Hidayah Shahemi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nur Hidayah Shahemi has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synthesis and characterization of electroactive chitosan/gelatin/PEDOT:PSS hydrogels with mixed ionic–electronic conductivity for potential wound healing applications

    by Dania Adila Ahmad Ruzaidi, Mashani Mohamad, Norita Salim, Zarif Mohamed Sofian, Nur Hidayah Shahemi, Hazwanee Osman, Rosmamuhamadani Ramli, Mohamed Izzharif Abdul Halim, Mohd Ifwat Mohd Ghazali, Kishor Kumar Sadasivuni, et al.

    The development of electroactive hydrogels as wound dressings represents a promising strategy to actively promote tissue regeneration by providing structural support, electrical stimulation, and localized therapeutic delivery. Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS), a conductive polymer, offers bioelectrical cues via its conjugated π-orbitals, but its practical application is limited by instability and leaching under physiological conditions. In this study, we aimed to design and characterize chitosan/gelatin/PEDOT:PSS (CGPP) hydrogels with controlled architecture, mixed ionic–electronic conductivity, and degradability suitable for wound-healing applications. Hydrogels were prepared via a cost-effective reverse-casting method using low-melting-point agarose as a sacrificial pore template and were chemically crosslinked for structural stability. Comprehensive characterization, including FESEM, ATR-FTIR spectroscopy, XRD, swelling studies, contact angle measurements, weight loss studies, UV-vis spectroscopy, and electrochemical impedance spectroscopy (EIS), revealed that PEDOT:PSS was successfully integrated into the hydrogel network, producing porous, interconnected architectures with semi-conductive properties (3.78 × 10−4 to 2.46 × 10−3 S cm−1) comparable to native skin tissue. CGPP-4, the formulation with optimal conductivity, exhibited sustained electrical performance over 1 week, was biocompatible, and supported keratinocyte (HaCaT) proliferation and wound closure at biologically relevant concentrations. Incorporation of curcumin further enhanced regenerative outcomes, with 15.625 µg mL−1 identified as the optimal dose for complete re-epithelialization. These results highlight the innovative integration of electroconductivity, controlled degradability, and drug delivery in CGPP hydrogels, establishing them as multifunctional platforms for next-generation bioelectronic wound dressings.


  • Polypyrrole (PPy) coating concentration mediates electromagnetic coupling and oxidative protection for iron oxide core particles in biomedical applications

    by Shahemi Nur Hidayah, Kasri Mohamad Arif, Ab Rahim Sharaniza, Amir Muhammad Abid, Sikiru Surajudeen, Mahat Mohd Muzamir

    This work highlights the dual-functionality of PPy coatings, which simultaneously enhances electromagnetic properties and provides oxidative degradation protection in physiologically relevant environments.


  • Sequentially crosslinked collagen‐based hydrogel to form a semi‐interpenetrating network for enhanced stability to hydrolytic degradation and electrochemical properties

    by Shahemi Nur Hidayah, Ahmad Ruzaidi Dania Adila, Ab Rahim Sharaniza, Amir Muhammad Abid, Mahat Mohd Muzamir

    Biodegradable polymers are pivotal in tissue engineering, facilitating long‐term tissue reintegration and reducing the necessity for surgery. However, collagen, a crucial component of the extracellular matrix, encountered challenges due to its limited mechanical strength and rapid in‐vivo degradation. This study addresses these issues through crosslinking and functionalizing collagen with synthetic 4‐arm amine‐terminated polyethylene glycol (PEG) in a semi‐interpenetrating network (IPN) hydrogel. The first goal is to enhance resistance to hydrolysis, thus extending the biodegradation rate. Then, to explore its electrical conductivity properties for certain applications like neural tissue regeneration. The hydrogels were fabricated using sequential IPN formation synthesis where their structural stability and type of degradation by‐products were confirmed using Fourier‐transform infrared spectroscopy (FTIR), Raman spectroscopy, scanning electron microscopy (SEM), and nuclear magnetic resonance (NMR). Next, its mechanical and degradation properties investigations exhibit a 92% enhancement in hardness and a 90% retainment of its initial mass over time under physiological conditions. Additionally, the introduction of polypyrrole (PPy) via in‐situ polymerization increases its electrical conductivity, achieving a remarkable 104‐fold increase at a 0.75 M concentration, attributed to the interconnectivity of PPy chain networks within the three‐dimensional structure of IPN collagen/PEG hydrogel. The increased PPy concentration improves conductivity and reduces energy requirements for redox reactions, ensuring electrochemical stability as revealed by cyclic voltammetry analysis. The demonstrated structural and electrochemical stability of the semi‐IPN collagen/PEG/PPy hydrogel within a physiological environment through a facile sequential crosslinking method underscores its promising practical applications in enhancing clinical effectiveness.


  • Application of Conductive Hydrogels on Spinal Cord Injury Repair: A Review

    by Nur Hidayah Shahemi, Mohd Muzamir Mahat, Nurul Ain Najihah Asri, Muhammad Abid Amir, Sharaniza Ab Rahim, Mohamad Arif Kasri

    Spinal cord injury (SCI) causes severe motor or sensory damage that leads to long-term disabilities due to disruption of electrical conduction in neuronal pathways. Despite current clinical therapies being used to limit the propagation of cell or tissue damage, the need for neuroregenerative therapies remains. Conductive hydrogels have been considered a promising neuroregenerative therapy due to their ability to provide a pro-regenerative microenvironment and flexible structure, which conforms to a complex SCI lesion. Furthermore, their conductivity can be utilized for noninvasive electrical signaling in dictating neuronal cell behavior. However, the ability of hydrogels to guide directional axon growth to reach the distal end for complete nerve reconnection remains a critical challenge. In this Review, we highlight recent advances in conductive hydrogels, including the incorporation of conductive materials, fabrication techniques, and cross-linking interactions. We also discuss important characteristics for designing conductive hydrogels for directional growth and regenerative therapy. We propose insights into electrical conductivity properties in a hydrogel that could be implemented as guidance for directional cell growth for SCI applications. Specifically, we highlight the practical implications of recent findings in the field, including the potential for conductive hydrogels to be used in clinical applications. We conclude that conductive hydrogels are a promising neuroregenerative therapy for SCI and that further research is needed to optimize their design and application.


  • Effects of surface wettability and thermal conductivity on the wear performance of ultrahigh molecular weight polyethylene/graphite and ultrahigh molecular weight polyethylene/graphene oxide composites

    by Nur Hidayah Shahemi, Shahira Liza, Yoshinori Sawae, Takehiro Morita, Hironori Shinmori, Yazid Yaakob

    Recent studies have found a rapid increase of ultrahigh molecular weight polyethylene (UHMWPE) wear in the presence of proteins from the synovial fluid. Due to UHMWPE's high hydrophobicity, it tends to adsorb a tremendous amount of proteins. Moreover, since UHMWPE has low thermal conductivity, a temperature rise in the center of the contact area due to frictional heating could cause protein denaturation from the synovial fluid. It has been shown that the denatured protein may increase the adhesive wear response. This study aimed to address the effects of graphite and graphene oxide (GO) addition on the wear properties of UHMWPE in protein environments. The surface properties were characterized using surface roughness profiler, surface energy evaluation, zeta potential, and Fourier transform infra‐red (FTIR). Following that, wear properties of UHMWPE composite were evaluated using a multidirectional pin‐on‐disc wear test under a bovine serum lubricated condition. The worn surface of the UHMWPE composite sample was evaluated, and the dominating factors of wear properties were determined. The effect of protein adsorption on the composite surface was also assessed after the wear test. The hydrophilicity of UHWMPE/1.0GO is considered to be the dominant contribution determining protein adsorption in static conditions. UHMWPE composite's wear resistance improvement was primarily dominated by GO filler (1.0 wt%) near the sliding surface, which has improved the subsurface strength of the material and heat dissipation effect, which reduces the denaturation of the proteins.


  • The relations between wear behavior and basic material properties of graphene‐based materials reinforced ultrahigh molecular weight polyethylene

    by Nur Hidayah Shahemi, Shahira Liza, Yoshinori Sawae, Takehiro Morita, Kanao Fukuda, Yazid Yaakob

    This article aims to investigate the influence of reinforcing graphene oxide (GO) and graphite flakes (GF) fillers into ultrahigh molecular weight polyethylene (UHMWPE) for orthopedic application. These fillers were expected to physically bond to UHMWPE, thus can enhance the subsurface strength, improving the wear behavior of the composites. UHMWPE/GO and UHMWPE/GF composites were prepared at 0.1 and 1.0 wt% by melt‐blending, followed by a compression molding technique. A multidirectional pin‐on‐disc wear test was performed to simulate the kinematic of hip application. Whilst getting exposed in the artificial in‐vivo lubricant bath (30 v/v% diluted bovine serum). Following this, the wear mechanism fostered by each filler (GO and GF) was determined by wear features obtained from the optical microscope and scanning electron microscope (SEM). The crystallinity degree and crystal defect were assessed using x‐ray diffraction (XRD). The mechanical properties of fabricated composites were evaluated by using a universal testing machine and Vickers microhardness. We found that UHMWPE/GO has the lowest specific wear rate due to the improved subsurface strength, as the reduction of a weak adhesive point was observed on the worn surface. Meanwhile, higher GF content (1 wt%) in UHMWPE displayed a lower specific wear rate than neat UHMWPE after completing the 10 km sliding distance attributed to the filler resurfaced, responsible for providing a strong resistance of the shear stress applied upon sliding with the metal counterface. Interestingly, the hardness and tensile strength for both UHMWPE/GO and UHMWPE/GF increased, although the crystallinity percentage was declining compared to neat UHMWPE.