Jobin Christ M C
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jobin Christ M C has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- C. Muralidharan
Department of Biomedical Engineering Rajalakshmi Engineering College Anna University Chennai India
1 shared publication - Jothiraj Selvaraj
Department of Biomedical Engineering, School of Engineering and Technology, Karunya Institute of Technology and Sciences, Coimbatore 641114, Tamil Nadu, India
1 shared publication - Rahul Krishnan
Department of Electronics and Communication Engineering, Rajalakshmi Institute of Technology, Chennai, India
1 shared publication - Sameera Fathimal Mohamed Ali
Department of Biomedical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
1 shared publication
Latest Publications
- Open Access
- 30 January 2026
- Published by Sri Lanka Journals Online in Journal of the National Science Foundation of Sri Lanka
- Vol. 53 (4)
Chest anteroposterior diameter measurement: Comparison of ultrasonic and manual methods across different BMI categories
Chest anteroposterior diameter (APD) measurement is a critical metric in evaluating thoracic dimensions, particularly in assessing conditions like pectus excavatum and guiding interventions such as laryngoscopy and cardiopulmonary resuscitation. The lateral distance measurement of the thoracic cavity using the computed tomography image provides APD, but they expose the subject to radiation. Though the manual method of chest APD measurement using a wooden ruler is radiation-free, it is time-consuming and prone to human errors. This study proposes a novel and radiation-free method of measuring chest APD using an ultrasonic sensor. The accuracy and reliability of the measured chest APD using the ultrasonic method were compared with the manual method across three distinct BMI categories of 150 participants. The measured chest APD using ultrasonic and manual methods for underweight, normal, and obese participants ranges from 17-18 cm, 18.5-20.5 cm, and 23.75-25 cm, respectively. The statistical analyses, including paired t-tests and intra-class correlation coefficients (ICC), were performed to assess agreement between the two methods. The paired t-test manifests no significant difference between the mean APD measured using ultrasonic and manual methods with p-values of 0.8742 (underweight), 0.7390 (normal), and 0.7998 (obese). The ICC values obtained from the intra- and inter-observers for the ultrasonic and manual methods were ICC ≥ 0.93, 0.80 ≤ ICC ≤ 0.82 and 0.91, and 0.78. The ICC value obtained from the intra- and inter-observers for the ultrasonic method was high, so the ultrasonic method is better than the manual method. This study concludes that the ultrasonic method provides a radiation-free alternative to the manual method, making it suitable for routine clinical use globally.
- 30 January 2026
- Published by Sri Lanka Journals Online in Journal of the National Science Foundation of Sri Lanka
- Vol. 53 (4)
Open AccessChest anteroposterior diameter measurement: Comparison of ultrasonic and manual methods across different BMI categories
Chest anteroposterior diameter (APD) measurement is a critical metric in evaluating thoracic dimensions, particularly in assessing conditions like pectus excavatum and guiding interventions such as laryngoscopy and cardiopulmonary resuscitation. The lateral distance measurement of the thoracic cavity using the computed tomography image provides APD, but they expose the subject to radiation. Though the manual method of chest APD measurement using a wooden ruler is radiation-free, it is time-consuming and prone to human errors. This study proposes a novel and radiation-free method of measuring chest APD using an ultrasonic sensor. The accuracy and reliability of the measured chest APD using the ultrasonic method were compared with the manual method across three distinct BMI categories of 150 participants. The measured chest APD using ultrasonic and manual methods for underweight, normal, and obese participants ranges from 17-18 cm, 18.5-20.5 cm, and 23.75-25 cm, respectively. The statistical analyses, including paired t-tests and intra-class correlation coefficients (ICC), were performed to assess agreement between the two methods. The paired t-test manifests no significant difference between the mean APD measured using ultrasonic and manual methods with p-values of 0.8742 (underweight), 0.7390 (normal), and 0.7998 (obese). The ICC values obtained from the intra- and inter-observers for the ultrasonic and manual methods were ICC ≥ 0.93, 0.80 ≤ ICC ≤ 0.82 and 0.91, and 0.78. The ICC value obtained from the intra- and inter-observers for the ultrasonic method was high, so the ultrasonic method is better than the manual method. This study concludes that the ultrasonic method provides a radiation-free alternative to the manual method, making it suitable for routine clinical use globally.
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1761-1766
A Framework of Computerized Database Management System based on Web Module for Biomedical Engineering Department in Hospital
A database is an organized collection of data that allows content to be easily accessed, managed, retrieved and updated when required. A Web-based Biomedical Database Management System was developed for a multispecialty hospital to provide assistance for the hospital in order to manage and maintain their own database. Data of 348 medical equipment from 15 departments in the hospital were collected and each of the device was assigned with a unique asset number according to NABH standards and for ease of representation. The web module is built by Java language. My SQL (My Structured Query Language) is utilized to run the user information. The proposed system has the capability to manage the database of medical devices from the initial log-in to the service provided. Three login credentials are allotted for admin, biomedical engineer and nursing staff. Administrators can add asset name, device information, medical department, device serial number, and warranty expiration date. A dashboard is also provided to view total assets, complaints, and planned preventive maintenance (PPM) data. Nursing staff can file complaints, and biomedical engineers can review complaints. A notification pop up appears after the login page so as to enhance the user experience and intimate the updated information.
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1761-1766
A Framework of Computerized Database Management System based on Web Module for Biomedical Engineering Department in Hospital
A database is an organized collection of data that allows content to be easily accessed, managed, retrieved and updated when required. A Web-based Biomedical Database Management System was developed for a multispecialty hospital to provide assistance for the hospital in order to manage and maintain their own database. Data of 348 medical equipment from 15 departments in the hospital were collected and each of the device was assigned with a unique asset number according to NABH standards and for ease of representation. The web module is built by Java language. My SQL (My Structured Query Language) is utilized to run the user information. The proposed system has the capability to manage the database of medical devices from the initial log-in to the service provided. Three login credentials are allotted for admin, biomedical engineer and nursing staff. Administrators can add asset name, device information, medical department, device serial number, and warranty expiration date. A dashboard is also provided to view total assets, complaints, and planned preventive maintenance (PPM) data. Nursing staff can file complaints, and biomedical engineers can review complaints. A notification pop up appears after the login page so as to enhance the user experience and intimate the updated information.
- 28 December 2021
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 17 (12) , 1425-1431
An Investigation Using Specific Absorption Rate Analysis to Diagnose Early- stage Breast Tumor using UWB Antenna
Aims: This work was focused on the detection of early-stage breast tumors and their location. Background: The most frequently seen disease progression and mortality in women's lives is Breast Cancer. Because of breast cancer/tumors, the risk of mortality for women has risen exponentially. From the 2020 deadline for breast cancer, women who died from carcinoma were 123.8 cases per lac women between 2006-2010. This problem is also overcome by the early identification of the tumor using different detection procedures like X-ray mammography, computerized tomography, ultrasound imaging technique, Positron Emission Tomography (PET), Magnetic Resonance Imaging (MRI), microwave imaging. Researchers carried out multiple studies in these areas. Objective: To detect early-stage breast tumors and their location using SAR analysis. Methods: The major dielectrical difference between cancerous breast tissues and normal tissues in this technique is the microwave frequency range. The term Specific Absorption Rate (SAR) describes the amount of energy which is absorbed (W/kg) in the breast tissue. This segment illustrates the usefulness to diagnose the tumor position in the breast by means of maximum SAR value coordinates. Changes in breast and tumor size are important for the risk of diagnosis. The power absorbed in connecting with a normal breast and a tumor breast is measured and equivalent for different breast masses. The maximum SAR is also analyzed at distinct tumor locations at various frequency ranges. Results: It is observed that max SAR coordinates are very close to the actual tumor location. So, the maximal value of SAR coordinates indicates the existence of a tumor in the breast phantom. Conclusion: The simulated data above strongly suggests that the Max SAR values were higher in the breast phantom with tumor as compared to the breast without tumor. With different tumor radius (3 mm and 5 mm) analyzed with different resonant frequencies like 3GHz, 4GHz and 5GHz at the actual tumor location of (0, 0, 35). Even though a model representing the real properties of breast tissue is required to assess the validation of any imaging process, so the real-time development of an equivalent breast phantom and its execution is needed.
- 28 December 2021
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 17 (12) , 1425-1431
An Investigation Using Specific Absorption Rate Analysis to Diagnose Early- stage Breast Tumor using UWB Antenna
Aims: This work was focused on the detection of early-stage breast tumors and their location. Background: The most frequently seen disease progression and mortality in women's lives is Breast Cancer. Because of breast cancer/tumors, the risk of mortality for women has risen exponentially. From the 2020 deadline for breast cancer, women who died from carcinoma were 123.8 cases per lac women between 2006-2010. This problem is also overcome by the early identification of the tumor using different detection procedures like X-ray mammography, computerized tomography, ultrasound imaging technique, Positron Emission Tomography (PET), Magnetic Resonance Imaging (MRI), microwave imaging. Researchers carried out multiple studies in these areas. Objective: To detect early-stage breast tumors and their location using SAR analysis. Methods: The major dielectrical difference between cancerous breast tissues and normal tissues in this technique is the microwave frequency range. The term Specific Absorption Rate (SAR) describes the amount of energy which is absorbed (W/kg) in the breast tissue. This segment illustrates the usefulness to diagnose the tumor position in the breast by means of maximum SAR value coordinates. Changes in breast and tumor size are important for the risk of diagnosis. The power absorbed in connecting with a normal breast and a tumor breast is measured and equivalent for different breast masses. The maximum SAR is also analyzed at distinct tumor locations at various frequency ranges. Results: It is observed that max SAR coordinates are very close to the actual tumor location. So, the maximal value of SAR coordinates indicates the existence of a tumor in the breast phantom. Conclusion: The simulated data above strongly suggests that the Max SAR values were higher in the breast phantom with tumor as compared to the breast without tumor. With different tumor radius (3 mm and 5 mm) analyzed with different resonant frequencies like 3GHz, 4GHz and 5GHz at the actual tumor location of (0, 0, 35). Even though a model representing the real properties of breast tissue is required to assess the validation of any imaging process, so the real-time development of an equivalent breast phantom and its execution is needed.