Souradeep Roy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Souradeep Roy has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Ashish Mathur
Centre for Interdisciplinary Research and Innovation (CIDRI), University of Petroleum and Energy Studies, Dehradun 248007, India
8 shared publications - Ranjit Kumar
Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida, India
2 shared publications - Satheesh Krishnamurthy
Ion Beam Centre Advanced Technology Institute University of Surrey Guildford United Kingdom
2 shared publications - Shalini Nagabooshanam
Department of Engineering Design, Indian Institute of Technology Madras, Chennai 600036, India
2 shared publications Shikha Wadhwa
Department of Chemistry, School of Advanced Engineering, UPES (Bidholi), Dehradun, Uttarakhand 248007, India
2 shared publications- Shikha Wadhwa
Amity University
2 shared publications
Latest Publications
- 26 June 2025
- Published by American Chemical Society (ACS) in Langmuir
Mechanistic Insights into Heterogeneous Electron Transfer Kinetics of Ti3C2Tx and V2CTx MXene-Based Nanoelectrodes: An Electrochemical and DFT Correlation
MXene (transition metal carbides/nitrides) exhibits promising physical and chemical properties due to its layered nanosheet-like morphology and high surface area and the presence of surface functional groups that are essential for developing efficient electrochemical sensing devices that can function reliably in on-field or real-time conditions. However, the understanding of the heterogeneous electron transfer (HET) mechanism in MXene, particularly the electrode-electrolyte interface, remains limited within the scientific community. In this study, we conduct an in-depth investigation of the basic chemistry behind the electron transfer kinetics of Ti3C2Tx and V2CTX MXene, respectively, on carbon screen-printed electrodes (CSPE). The HET kinetics was thoroughly studied by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), which was correlated with the electronic density of states (eDOS) of the two MXenes via density functional theory (DFT). It was observed that Ti3C2Tx-modified nanoelectrodes exhibit an enhanced electron transfer rate (ket ∼0.03 cm/s) as compared to V2CTx nanoelectrodes (ket ∼0.0064 cm/s). This is primarily attributed to higher quantum capacitance Cq ∼ 356 nF in the former due to increased eDOS, as evidenced by DFT simulations. The current study suggests that Ti3C2Tx MXene exhibits superior HET kinetics compared to V2CTx MXene. Hence, the Ti3C2Tx MXene can be efficiently utilized in development of electrochemical sensors.
- 26 June 2025
- Published by American Chemical Society (ACS) in Langmuir
Mechanistic Insights into Heterogeneous Electron Transfer Kinetics of Ti3C2Tx and V2CTx MXene-Based Nanoelectrodes: An Electrochemical and DFT Correlation
MXene (transition metal carbides/nitrides) exhibits promising physical and chemical properties due to its layered nanosheet-like morphology and high surface area and the presence of surface functional groups that are essential for developing efficient electrochemical sensing devices that can function reliably in on-field or real-time conditions. However, the understanding of the heterogeneous electron transfer (HET) mechanism in MXene, particularly the electrode-electrolyte interface, remains limited within the scientific community. In this study, we conduct an in-depth investigation of the basic chemistry behind the electron transfer kinetics of Ti3C2Tx and V2CTX MXene, respectively, on carbon screen-printed electrodes (CSPE). The HET kinetics was thoroughly studied by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), which was correlated with the electronic density of states (eDOS) of the two MXenes via density functional theory (DFT). It was observed that Ti3C2Tx-modified nanoelectrodes exhibit an enhanced electron transfer rate (ket ∼0.03 cm/s) as compared to V2CTx nanoelectrodes (ket ∼0.0064 cm/s). This is primarily attributed to higher quantum capacitance Cq ∼ 356 nF in the former due to increased eDOS, as evidenced by DFT simulations. The current study suggests that Ti3C2Tx MXene exhibits superior HET kinetics compared to V2CTx MXene. Hence, the Ti3C2Tx MXene can be efficiently utilized in development of electrochemical sensors.
- Open Access
- 12 March 2025
- Published by MDPI AG in Technologies
- Vol. 13 (3) , 114
Portable DNA Probe Detector and a New Dry-QCM Approach for SARS-CoV-2 Detection
This work demonstrates the preliminary results of rapid and direct detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) using the quartz crystal microbalance (QCM) method. Coronavirus Disease 2019 (COVID-19)-specific RNA-dependent RNA polymerase (RdRP) gene-dependent probe DNA was used as a selective agent toward target DNA, the inactivated SARS-CoV-2 virus, and RNAs extracted from clinical samples. This study developed and utilised a unique dry-QCM approach with a mitigated experimental procedure. Contact angle measurements, Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS) measurements were employed to investigate the surface during probe immobilisation and target hybridisation. This study also investigates the effect of temperature on probe immobilisation and target hybridisation. The estimated probe density was 0.51 × 1012 probes/cm2, which is below the critical limit. The estimated hybridisation efficiency was about 58.9%. The linear detection range with a Limit of Detection (LoD) was about ~1.22 nM with high selectivity toward SARS-CoV-2 target DNA. The sensor shelf-life was found to be extended to 25 days. The novelty of using a new dry-QCM approach for SARS-CoV-2 detection was proven with the results.
- 12 March 2025
- Published by MDPI AG in Technologies
- Vol. 13 (3) , 114
Open AccessPortable DNA Probe Detector and a New Dry-QCM Approach for SARS-CoV-2 Detection
This work demonstrates the preliminary results of rapid and direct detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) using the quartz crystal microbalance (QCM) method. Coronavirus Disease 2019 (COVID-19)-specific RNA-dependent RNA polymerase (RdRP) gene-dependent probe DNA was used as a selective agent toward target DNA, the inactivated SARS-CoV-2 virus, and RNAs extracted from clinical samples. This study developed and utilised a unique dry-QCM approach with a mitigated experimental procedure. Contact angle measurements, Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS) measurements were employed to investigate the surface during probe immobilisation and target hybridisation. This study also investigates the effect of temperature on probe immobilisation and target hybridisation. The estimated probe density was 0.51 × 1012 probes/cm2, which is below the critical limit. The estimated hybridisation efficiency was about 58.9%. The linear detection range with a Limit of Detection (LoD) was about ~1.22 nM with high selectivity toward SARS-CoV-2 target DNA. The sensor shelf-life was found to be extended to 25 days. The novelty of using a new dry-QCM approach for SARS-CoV-2 detection was proven with the results.
- 7 January 2025
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 8 (1) , 715-725
Exploiting the Electrostatic Binding of Ruthenium Hexamine Molecular Redox Nanowires onto DNA/OGCN Biohybrid Electrodes toward the Electrochemical Detection of COVID-19
The Coronavirus Disease 2019 (COVID-19) recently emerged as a life-threatening global pandemic that has ravaged millions of lives. The affected patients are known to frequently register numerous comorbidities induced by COVID-19 such as diabetes, asthma, cardiac arrest, hypertension, and neurodegenerative diseases, to name a few. The expensiveness and probability of false negative results of conventional screening tests often delay timely diagnosis and treatment. In such cases, the deployment of a suitable biosensing platform can readily expedite the rapid diagnosis process for enhanced patient outcomes. We report the development of an electrochemical genosensor based on DNA/OGCN (DNA/oxygenated graphitic carbon nitride) nanohybrids for the quantification of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) DNA─the key biomarker for COVID-19. This is achieved by exploiting the molecular nanowire-formation capability of the [Ru(NH3)6]2+/3+ redox probe onto the DNA phosphate backbone via electrostatic interactions. The microstructural characterization of OGCN was performed using scanning electron microscopy (SEM) coupled with an energy-dispersive X-ray (EDX) module, X-ray diffraction (XRD), and Fourier transform infrared spectroscopy. The electrochemical analyses were performed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), while the analytical performance of the sensor was evaluated using square wave voltammetry (SWV). The developed sensor exhibited a wide linear detection range within 10 fM-10 μM, with a limit of detection (LoD) of ∼7.23 fM with a high degree of selectivity toward SARS-CoV-2 target DNA, thereby indicating its potential to be employed in a point-of-care scenario toward providing affordable healthcare to the global populace.
- 7 January 2025
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 8 (1) , 715-725
Exploiting the Electrostatic Binding of Ruthenium Hexamine Molecular Redox Nanowires onto DNA/OGCN Biohybrid Electrodes toward the Electrochemical Detection of COVID-19
The Coronavirus Disease 2019 (COVID-19) recently emerged as a life-threatening global pandemic that has ravaged millions of lives. The affected patients are known to frequently register numerous comorbidities induced by COVID-19 such as diabetes, asthma, cardiac arrest, hypertension, and neurodegenerative diseases, to name a few. The expensiveness and probability of false negative results of conventional screening tests often delay timely diagnosis and treatment. In such cases, the deployment of a suitable biosensing platform can readily expedite the rapid diagnosis process for enhanced patient outcomes. We report the development of an electrochemical genosensor based on DNA/OGCN (DNA/oxygenated graphitic carbon nitride) nanohybrids for the quantification of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) DNA─the key biomarker for COVID-19. This is achieved by exploiting the molecular nanowire-formation capability of the [Ru(NH3)6]2+/3+ redox probe onto the DNA phosphate backbone via electrostatic interactions. The microstructural characterization of OGCN was performed using scanning electron microscopy (SEM) coupled with an energy-dispersive X-ray (EDX) module, X-ray diffraction (XRD), and Fourier transform infrared spectroscopy. The electrochemical analyses were performed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), while the analytical performance of the sensor was evaluated using square wave voltammetry (SWV). The developed sensor exhibited a wide linear detection range within 10 fM-10 μM, with a limit of detection (LoD) of ∼7.23 fM with a high degree of selectivity toward SARS-CoV-2 target DNA, thereby indicating its potential to be employed in a point-of-care scenario toward providing affordable healthcare to the global populace.
- Open Access
- 28 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (9) , 2087
An Electroanalytical Flexible Biosensor Based on Reduced Graphene Oxide-DNA Hybrids for the Early Detection of Human Papillomavirus-16
Human Papilloma Virus 16 (HPV 16) is the well-known causative species responsible for triggering cervical cancer. When left undiagnosed and untreated, this disease leads to life-threatening events among the female populace, especially in developing nations where healthcare resources are already being stretched to their limits. Considering various drawbacks of conventional techniques for diagnosing this highly malignant cancer, it becomes imperative to develop miniaturized biosensing platforms which can aid in early detection of cervical cancer for enhanced patient outcomes. The current study reports on the development of an electrochemical biosensor based on reduced graphene oxide (rGO)/DNA hybrid modified flexible carbon screen-printed electrode (CSPE) for the detection of HPV 16. The carbon-coated SPEs were initially coated with rGO followed by probe DNA (PDNA) immobilization. The nanostructure characterization was performed using UV-Vis spectroscopy, Fourier transform infrared (FTIR) spectroscopy, Raman spectroscopy and X-ray diffraction (XRD) techniques. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were employed to study the electrochemical characterization of the nano-biohybrid sensor surface. The optimization studies and analytical performance were assessed using differential pulse voltammetry (DPV), eventually exhibiting a limit of detection (LoD) ~2 pM. The developed sensor was found to be selective solely to HPV 16 target DNA and exhibited a shelf life of 1 month. The performance of the developed flexible sensor further exhibited a promising response in spiked serum samples, which validates its application in future point-of-care scenarios.
- 28 August 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (9) , 2087
Open AccessAn Electroanalytical Flexible Biosensor Based on Reduced Graphene Oxide-DNA Hybrids for the Early Detection of Human Papillomavirus-16
Human Papilloma Virus 16 (HPV 16) is the well-known causative species responsible for triggering cervical cancer. When left undiagnosed and untreated, this disease leads to life-threatening events among the female populace, especially in developing nations where healthcare resources are already being stretched to their limits. Considering various drawbacks of conventional techniques for diagnosing this highly malignant cancer, it becomes imperative to develop miniaturized biosensing platforms which can aid in early detection of cervical cancer for enhanced patient outcomes. The current study reports on the development of an electrochemical biosensor based on reduced graphene oxide (rGO)/DNA hybrid modified flexible carbon screen-printed electrode (CSPE) for the detection of HPV 16. The carbon-coated SPEs were initially coated with rGO followed by probe DNA (PDNA) immobilization. The nanostructure characterization was performed using UV-Vis spectroscopy, Fourier transform infrared (FTIR) spectroscopy, Raman spectroscopy and X-ray diffraction (XRD) techniques. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were employed to study the electrochemical characterization of the nano-biohybrid sensor surface. The optimization studies and analytical performance were assessed using differential pulse voltammetry (DPV), eventually exhibiting a limit of detection (LoD) ~2 pM. The developed sensor was found to be selective solely to HPV 16 target DNA and exhibited a shelf life of 1 month. The performance of the developed flexible sensor further exhibited a promising response in spiked serum samples, which validates its application in future point-of-care scenarios.
- Open Access
Ultra-Sensitive Immuno-Sensing Platform Based on Gold-Coated Interdigitated Electrodes for the Detection of Parathion
Pesticides are unavoidable in agriculture to protect crops from pests and insects. Organophosphates (OPs) are a class of pesticides that are more harmful because of the irreversible inhibition reaction with acetylcholinesterase enzyme, thereby posing serious health hazards in human beings. In the present work, a sensitive and selective immuno-sensing platform is developed using gold inter-digitized electrodes (Au-IDEs) as substrates, integrated with a microfluidic platform having the microfluidic well capacity of 10 µL. Au-IDE having digit width of 10 µm and gap length of 5 µm was used in this study. The surface morphological analysis by field-effect scanning electron microscopy (FE-SEM) and atomic force microscopy (AFM) revealed the direct information regarding the modification of Au-IDEs with anti-parathion (Anti-PT) antibodies. In SEM analysis, it was seen that the Au-IDE surface was smooth in contrast to the Anti-PT modified surface, which is supported by the AFM studies showing the surface roughness of ~2.02 nm for Au-IDE surface and ~15.86 nm for Anti-PT modified surface. Further, Fourier transform infra-red (FTIR) spectroscopic analysis confirms the immobilization of Anti-PT by the bond vibrations upon the successive modification of Au-IDE with -OH groups, amine groups after modifying with APTES, and the amide bond formation after incubation in Anti-PT antibody. Electrochemical impedance spectroscopy (EIS) was carried out for the electrochemical characterization and for testing the sensing performances of the fabricated electrode. The developed immuno-sensor provided a linear range of detection from 0.5 pg/L–1 µg/L, with a limit of detection (LoD) of 0.66 ng/L and sensitivity of 4.1 MΩ/ngL−1/cm2. The sensor response was also examined with real samples (pomegranate juice) with good accuracy, exhibiting a shelf life of 25 days. The miniaturized sensing platform, along with its better sensing performance, has huge potential to be integrated into portable electronics, leading to suitable field applications of pesticide screening devices.
Open AccessUltra-Sensitive Immuno-Sensing Platform Based on Gold-Coated Interdigitated Electrodes for the Detection of Parathion
Pesticides are unavoidable in agriculture to protect crops from pests and insects. Organophosphates (OPs) are a class of pesticides that are more harmful because of the irreversible inhibition reaction with acetylcholinesterase enzyme, thereby posing serious health hazards in human beings. In the present work, a sensitive and selective immuno-sensing platform is developed using gold inter-digitized electrodes (Au-IDEs) as substrates, integrated with a microfluidic platform having the microfluidic well capacity of 10 µL. Au-IDE having digit width of 10 µm and gap length of 5 µm was used in this study. The surface morphological analysis by field-effect scanning electron microscopy (FE-SEM) and atomic force microscopy (AFM) revealed the direct information regarding the modification of Au-IDEs with anti-parathion (Anti-PT) antibodies. In SEM analysis, it was seen that the Au-IDE surface was smooth in contrast to the Anti-PT modified surface, which is supported by the AFM studies showing the surface roughness of ~2.02 nm for Au-IDE surface and ~15.86 nm for Anti-PT modified surface. Further, Fourier transform infra-red (FTIR) spectroscopic analysis confirms the immobilization of Anti-PT by the bond vibrations upon the successive modification of Au-IDE with -OH groups, amine groups after modifying with APTES, and the amide bond formation after incubation in Anti-PT antibody. Electrochemical impedance spectroscopy (EIS) was carried out for the electrochemical characterization and for testing the sensing performances of the fabricated electrode. The developed immuno-sensor provided a linear range of detection from 0.5 pg/L–1 µg/L, with a limit of detection (LoD) of 0.66 ng/L and sensitivity of 4.1 MΩ/ngL−1/cm2. The sensor response was also examined with real samples (pomegranate juice) with good accuracy, exhibiting a shelf life of 25 days. The miniaturized sensing platform, along with its better sensing performance, has huge potential to be integrated into portable electronics, leading to suitable field applications of pesticide screening devices.
- Open Access
- 2 December 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (12) , 339
An Enzymatic Multiplexed Impedimetric Sensor Based on α-MnO2/GQD Nano-Composite for the Detection of Diabetes and Diabetic Foot Ulcer Using Micro-Fluidic Platform
Diabetes is widely considered as a silent killer which affects the internal organs and ultimately has drastic impacts on our day-to-day activities. One of the fatal outcomes of diabetes is diabetic foot ulcer (DFU); which, when becomes chronic, may lead to amputation. The incorporation of nanotechnology in developing bio-sensors enables the detection of desired biomarkers, which in our study are glucose and L-tyrosine; which gets elevated in patients suffering from diabetes and DFUs, respectively. Herein, we report the development of an enzymatic impedimetric sensor for the multi-detection of these biomarkers using an electrochemical paper-based analytical device (µ-EPADs). The structure consists of two working electrodes and a counter electrode. One working electrode is modified with α-MnO2-GQD/tyrosinase hybrid to aid L-tyrosine detection, while the other electrode is coated with α-MnO2-GQD/glucose oxidase hybrid for glucose monitoring. Electrochemical impedance spectroscopy has been employed for the quantification of glucose and L-tyrosine, within a concentration range of 50–800 mg/dL and 1–500 µmol/L, respectively, using a sample volume of approximately 200 µL. The impedance response exhibited a linear relationship over the analyte concentration range with detection limits of ~58 mg/dL and ~0.3 µmol/L for glucose and tyrosine respectively, with shelf life ~1 month. The sensing strategy was also translated to Arduino-based device applications by interfacing the µ-EPADs with miniaturized electronics.
- 2 December 2021
- Published by MDPI AG in Chemosensors
- Vol. 9 (12) , 339
Open AccessAn Enzymatic Multiplexed Impedimetric Sensor Based on α-MnO2/GQD Nano-Composite for the Detection of Diabetes and Diabetic Foot Ulcer Using Micro-Fluidic Platform
Diabetes is widely considered as a silent killer which affects the internal organs and ultimately has drastic impacts on our day-to-day activities. One of the fatal outcomes of diabetes is diabetic foot ulcer (DFU); which, when becomes chronic, may lead to amputation. The incorporation of nanotechnology in developing bio-sensors enables the detection of desired biomarkers, which in our study are glucose and L-tyrosine; which gets elevated in patients suffering from diabetes and DFUs, respectively. Herein, we report the development of an enzymatic impedimetric sensor for the multi-detection of these biomarkers using an electrochemical paper-based analytical device (µ-EPADs). The structure consists of two working electrodes and a counter electrode. One working electrode is modified with α-MnO2-GQD/tyrosinase hybrid to aid L-tyrosine detection, while the other electrode is coated with α-MnO2-GQD/glucose oxidase hybrid for glucose monitoring. Electrochemical impedance spectroscopy has been employed for the quantification of glucose and L-tyrosine, within a concentration range of 50–800 mg/dL and 1–500 µmol/L, respectively, using a sample volume of approximately 200 µL. The impedance response exhibited a linear relationship over the analyte concentration range with detection limits of ~58 mg/dL and ~0.3 µmol/L for glucose and tyrosine respectively, with shelf life ~1 month. The sensing strategy was also translated to Arduino-based device applications by interfacing the µ-EPADs with miniaturized electronics.
- 12 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (4) , 4129-4134
Development of Field Deployable Sensor for Detection of Pesticide From Food Chain
The use of pesticides in agriculture field remains a serious issue related to public health. This necessitates the need to develop a low cost/portable, sensitive and selective bio-sensing platform for detection of pesticides in food chain. In this work a low-cost biosensing platform for ultrasensitive detection of chlorpyrifos (CPF) is developed. Electrochemical micro Paper Analytical Device (ElPAD) is fabricated by conventional screen-printing technology. Metal Organic Framework (Z1200 MOF) having zinc metal and imidazole ligand is used as a transducing element which facilitates biocompatible matrix for Acetylcholinesterase (AChE) enzyme immobilization. The limit of detection for CPF is found be 3 ng/L with sensitivity 0.521 kY/ng L-1/mm2. The sensor required 100lL of reagent and was tested with a linear concentration range of 10 ng/L to 1000 ng/L with response time of 5s. The sensor is further integrated with portable electronics based on Arduino microcontroller and Artificial Intelligence (AI) which provided economical, portable and user-friendly sensing platform. The stability of the sensor was 30 days. The developed sensor was also tested with real samples and the sensor response is in agreement with conventional technique.
- 12 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (4) , 4129-4134
Development of Field Deployable Sensor for Detection of Pesticide From Food Chain
The use of pesticides in agriculture field remains a serious issue related to public health. This necessitates the need to develop a low cost/portable, sensitive and selective bio-sensing platform for detection of pesticides in food chain. In this work a low-cost biosensing platform for ultrasensitive detection of chlorpyrifos (CPF) is developed. Electrochemical micro Paper Analytical Device (ElPAD) is fabricated by conventional screen-printing technology. Metal Organic Framework (Z1200 MOF) having zinc metal and imidazole ligand is used as a transducing element which facilitates biocompatible matrix for Acetylcholinesterase (AChE) enzyme immobilization. The limit of detection for CPF is found be 3 ng/L with sensitivity 0.521 kY/ng L-1/mm2. The sensor required 100lL of reagent and was tested with a linear concentration range of 10 ng/L to 1000 ng/L with response time of 5s. The sensor is further integrated with portable electronics based on Arduino microcontroller and Artificial Intelligence (AI) which provided economical, portable and user-friendly sensing platform. The stability of the sensor was 30 days. The developed sensor was also tested with real samples and the sensor response is in agreement with conventional technique.