SNShalini Nagabooshanam

Shalini Nagabooshanam

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shalini Nagabooshanam has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Recent Advances of Biosensor-Integrated Organ-on-a-Chip Technologies for Diagnostics and Therapeutics

    by Ashwini Shinde, Kavitha Illath, Uvanesh Kasiviswanathan, Shalini Nagabooshanam, Pallavi Gupta, Koyel Dey, Pulasta Chakrabarty, Moeto Nagai, Suresh Rao, Srabani Kar, et al.


  • Open Access

    Ultra-Sensitive Impedimetric Immunosensor Using Copper Oxide Quantum Dots Grafted on the Gold Microelectrode for the Detection of Parathion

    by Shalini Nagabooshanam, Bhusankar Talluri, Tiju Thomas, Satheesh Krishnamurthy, Ashish Mathur

    The extensive use of organophosphates (OPs) pollutes the environment, leading to serious health hazards for human beings. The current need is to fabricate a sensing platform that will be sensitive and selective towards the detection of OPs at trace levels in the nM to fM range. With this discussed in the present report, an ultra-sensitive immunosensing platform is developed using digestive-ripened copper oxide quantum dots grafted on a gold microelectrode (Au-µE) for the impedimetric detection of parathion (PT). The copper oxide quantum dots utilized in this study were of ultra-small size with a radius of approximately 2 to 3 nm and were monodispersed with readily available functional groups for the potential immobilization of antibody parathion (Anti-PT). The miniaturization is achieved by the utilization of Au-µE and the microfluidic platform utilized has the sample holding capacity of about 2 to 10 µL. The developed immunosensor provided a wide linear range of detection from 1 µM to 1 fM. The lower Limit of Detection (LoD) for the developed sensing platform was calculated to be 0.69 fM, with the sensitivity calculated to be 0.14 kΩ/nM/mm2. The stability of the sensor was found to be ~40 days with good selectivity. The developed sensor has the potential to integrate with a portable device for field applications.


  • Open Access

    Ultra-Sensitive Immuno-Sensing Platform Based on Gold-Coated Interdigitated Electrodes for the Detection of Parathion

    by Shalini Nagabooshanam, Souradeep Roy, Shikha Wadhwa, Ashish Mathur, Satheesh Krishnamurthy, Lalit Mohan Bharadwaj

    Pesticides are unavoidable in agriculture to protect crops from pests and insects. Organophosphates (OPs) are a class of pesticides that are more harmful because of the irreversible inhibition reaction with acetylcholinesterase enzyme, thereby posing serious health hazards in human beings. In the present work, a sensitive and selective immuno-sensing platform is developed using gold inter-digitized electrodes (Au-IDEs) as substrates, integrated with a microfluidic platform having the microfluidic well capacity of 10 µL. Au-IDE having digit width of 10 µm and gap length of 5 µm was used in this study. The surface morphological analysis by field-effect scanning electron microscopy (FE-SEM) and atomic force microscopy (AFM) revealed the direct information regarding the modification of Au-IDEs with anti-parathion (Anti-PT) antibodies. In SEM analysis, it was seen that the Au-IDE surface was smooth in contrast to the Anti-PT modified surface, which is supported by the AFM studies showing the surface roughness of ~2.02 nm for Au-IDE surface and ~15.86 nm for Anti-PT modified surface. Further, Fourier transform infra-red (FTIR) spectroscopic analysis confirms the immobilization of Anti-PT by the bond vibrations upon the successive modification of Au-IDE with -OH groups, amine groups after modifying with APTES, and the amide bond formation after incubation in Anti-PT antibody. Electrochemical impedance spectroscopy (EIS) was carried out for the electrochemical characterization and for testing the sensing performances of the fabricated electrode. The developed immuno-sensor provided a linear range of detection from 0.5 pg/L–1 µg/L, with a limit of detection (LoD) of 0.66 ng/L and sensitivity of 4.1 MΩ/ngL−1/cm2. The sensor response was also examined with real samples (pomegranate juice) with good accuracy, exhibiting a shelf life of 25 days. The miniaturized sensing platform, along with its better sensing performance, has huge potential to be integrated into portable electronics, leading to suitable field applications of pesticide screening devices.


  • Development of Field Deployable Sensor for Detection of Pesticide From Food Chain

    by Shalini Nagabooshanam, Shruti Sharma, Souradeep Roy, Ashish Mathur, Satheesh Krishnamurthy, Lalit M. Bharadwaj

    The use of pesticides in agriculture field remains a serious issue related to public health. This necessitates the need to develop a low cost/portable, sensitive and selective bio-sensing platform for detection of pesticides in food chain. In this work a low-cost biosensing platform for ultrasensitive detection of chlorpyrifos (CPF) is developed. Electrochemical micro Paper Analytical Device (ElPAD) is fabricated by conventional screen-printing technology. Metal Organic Framework (Z1200 MOF) having zinc metal and imidazole ligand is used as a transducing element which facilitates biocompatible matrix for Acetylcholinesterase (AChE) enzyme immobilization. The limit of detection for CPF is found be 3 ng/L with sensitivity 0.521 kY/ng L-1/mm2. The sensor required 100lL of reagent and was tested with a linear concentration range of 10 ng/L to 1000 ng/L with response time of 5s. The sensor is further integrated with portable electronics based on Arduino microcontroller and Artificial Intelligence (AI) which provided economical, portable and user-friendly sensing platform. The stability of the sensor was 30 days. The developed sensor was also tested with real samples and the sensor response is in agreement with conventional technique.