Chih-Yen Chien
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chih-Yen Chien has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hong Chen
Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO, 63130, USA
6 shared publications - Christopher Pham Pacia
From the Department of Biomedical Engineering, Washington University in St Louis, 4511 Forest Park Ave, St Louis, MO 63108 (C.P.P., J.Y., Y.Y., E.C.L., H.C.); Department of Neurosurgery (E.C.L.), Mallinckrodt Institute of Radiology (T.L.S.B., A.N.), and Department of Radiation Oncology (H.C.), Washington University School of Medicine, St Louis, Mo
3 shared publications - Yan Gong
Department of Biomedical Engineering, Washington University in St. Louis, USA
3 shared publications - Yaoheng Yang
Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, USA
3 shared publications - Dezhuang Ye
Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, USA
2 shared publications Yimei Yue
Department of Biomedical Engineering, Washington University in St. Louis, USA
2 shared publications
Latest Publications
- Open Access
- 17 October 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (10) , 2479
Focused Ultrasound-Mediated Delivery of Anti-Programmed Cell Death-Ligand 1 Antibody to the Brain of a Porcine Model
Immune checkpoint inhibitor (ICI) therapy has revolutionized cancer treatment by leveraging the body’s immune system to combat cancer cells. However, its effectiveness in brain cancer is hindered by the blood-brain barrier (BBB), impeding the delivery of ICIs to brain tumor cells. This study aimed to assess the safety and feasibility of using focused ultrasound combined with microbubble-mediated BBB opening (FUS-BBBO) to facilitate trans-BBB delivery of an ICI, anti-programmed cell death-ligand 1 antibody (aPD-L1) to the brain of a large animal model. In a porcine model, FUS sonication of targeted brain regions was performed after intravenous microbubble injection, which was followed by intravenous administration of aPD-L1 labeled with a near-infrared fluorescent dye. The permeability of the BBB was evaluated using contrast-enhanced MRI in vivo, while fluorescence imaging and histological analysis were conducted on ex vivo pig brains. Results showed a significant 4.8-fold increase in MRI contrast-enhancement volume in FUS-targeted regions compared to nontargeted regions. FUS sonication enhanced aPD-L1 delivery by an average of 2.1-fold, according to fluorescence imaging. In vivo MRI and ex vivo staining revealed that the procedure did not cause significant acute tissue damage. These findings demonstrate that FUS-BBBO offers a noninvasive, localized, and safe delivery approach for ICI delivery in a large animal model, showcasing its potential for clinical translation.
- 17 October 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (10) , 2479
Open AccessFocused Ultrasound-Mediated Delivery of Anti-Programmed Cell Death-Ligand 1 Antibody to the Brain of a Porcine Model
Immune checkpoint inhibitor (ICI) therapy has revolutionized cancer treatment by leveraging the body’s immune system to combat cancer cells. However, its effectiveness in brain cancer is hindered by the blood-brain barrier (BBB), impeding the delivery of ICIs to brain tumor cells. This study aimed to assess the safety and feasibility of using focused ultrasound combined with microbubble-mediated BBB opening (FUS-BBBO) to facilitate trans-BBB delivery of an ICI, anti-programmed cell death-ligand 1 antibody (aPD-L1) to the brain of a large animal model. In a porcine model, FUS sonication of targeted brain regions was performed after intravenous microbubble injection, which was followed by intravenous administration of aPD-L1 labeled with a near-infrared fluorescent dye. The permeability of the BBB was evaluated using contrast-enhanced MRI in vivo, while fluorescence imaging and histological analysis were conducted on ex vivo pig brains. Results showed a significant 4.8-fold increase in MRI contrast-enhancement volume in FUS-targeted regions compared to nontargeted regions. FUS sonication enhanced aPD-L1 delivery by an average of 2.1-fold, according to fluorescence imaging. In vivo MRI and ex vivo staining revealed that the procedure did not cause significant acute tissue damage. These findings demonstrate that FUS-BBBO offers a noninvasive, localized, and safe delivery approach for ICI delivery in a large animal model, showcasing its potential for clinical translation.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (5) , 1528-1538
Characterization of the Targeting Accuracy of a Neuronavigation-Guided Transcranial FUS System In Vitro, In Vivo, and In Silico
Focused ultrasound (FUS)-enabled liquid biopsy (sonobiopsy) is an emerging technique for the noninvasive and spatiotemporally controlled diagnosis of brain cancer by inducing blood-brain barrier (BBB) disruption to release brain tumor-specific biomarkers into the blood circulation. The feasibility, safety, and efficacy of sonobiopsy were demonstrated in both small and large animal models using magnetic resonance-guided FUS devices. However, the high cost and complex operation of magnetic resonance-guided FUS devices limit the future broad application of sonobiopsy in the clinic. In this study, a neuronavigation-guided sonobiopsy device is developed and its targeting accuracy is characterized in vitro , in vivo , and in silico . The sonobiopsy device integrated a commercially available neuronavigation system (BrainSight) with a nimble, lightweight FUS transducer. Its targeting accuracy was characterized in vitro in a water tank using a hydrophone. The performance of the device in BBB disruption was verified in vivo using a pig model, and the targeting accuracy was quantified by measuring the offset between the target and the actual locations of BBB opening. The feasibility of the FUS device in targeting glioblastoma (GBM) tumors was evaluated in silico using numerical simulation by the k-Wave toolbox in glioblastoma patients. It was found that the targeting accuracy of the neuronavigation-guided sonobiopsy device was 1.7 ± 0.8 mm as measured in the water tank. The neuronavigation-guided FUS device successfully induced BBB disruption in pigs with a targeting accuracy of 3.3 ± 1.4 mm. The targeting accuracy of the FUS transducer at the GBM tumor was 5.5 ± 4.9 mm. Age, sex, and incident locations were found to be not correlated with the targeting accuracy in GBM patients. This study demonstrated that the developed neuronavigation-guided FUS device could target the brain with a high spatial targeting accuracy, paving the foundation for its application in the clinic.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (5) , 1528-1538
Characterization of the Targeting Accuracy of a Neuronavigation-Guided Transcranial FUS System In Vitro, In Vivo, and In Silico
Focused ultrasound (FUS)-enabled liquid biopsy (sonobiopsy) is an emerging technique for the noninvasive and spatiotemporally controlled diagnosis of brain cancer by inducing blood-brain barrier (BBB) disruption to release brain tumor-specific biomarkers into the blood circulation. The feasibility, safety, and efficacy of sonobiopsy were demonstrated in both small and large animal models using magnetic resonance-guided FUS devices. However, the high cost and complex operation of magnetic resonance-guided FUS devices limit the future broad application of sonobiopsy in the clinic. In this study, a neuronavigation-guided sonobiopsy device is developed and its targeting accuracy is characterized in vitro , in vivo , and in silico . The sonobiopsy device integrated a commercially available neuronavigation system (BrainSight) with a nimble, lightweight FUS transducer. Its targeting accuracy was characterized in vitro in a water tank using a hydrophone. The performance of the device in BBB disruption was verified in vivo using a pig model, and the targeting accuracy was quantified by measuring the offset between the target and the actual locations of BBB opening. The feasibility of the FUS device in targeting glioblastoma (GBM) tumors was evaluated in silico using numerical simulation by the k-Wave toolbox in glioblastoma patients. It was found that the targeting accuracy of the neuronavigation-guided sonobiopsy device was 1.7 ± 0.8 mm as measured in the water tank. The neuronavigation-guided FUS device successfully induced BBB disruption in pigs with a targeting accuracy of 3.3 ± 1.4 mm. The targeting accuracy of the FUS transducer at the GBM tumor was 5.5 ± 4.9 mm. Age, sex, and incident locations were found to be not correlated with the targeting accuracy in GBM patients. This study demonstrated that the developed neuronavigation-guided FUS device could target the brain with a high spatial targeting accuracy, paving the foundation for its application in the clinic.
- 27 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (11) , 3449-3459
Comparison of Sonication Patterns and Microbubble Administration Strategies for Focused Ultrasound-Mediated Large-Volume Drug Delivery
Objective: Diffuse intrinsic pontine glioma (DIPG) is the most common and deadliest brainstem tumor in children. Focused ultrasound combined with microbubble-mediated BBB opening (FUS-BBBO) is a promising technique for overcoming the frequently intact blood-brain barrier (BBB) in DIPG to enhance therapeutic drug delivery to the brainstem. Since DIPG is highly diffusive, large-volume FUS-BBBO is needed to cover the entire tumor region. The objective of this study was to determine the optimal treatment strategy to achieve efficient and homogeneous large-volume BBBO at the brainstem for the delivery of an immune checkpoint inhibitor, anti-PD-L1 antibody (aPD-L1). Methods: Two critical parameters for large-volume FUS-BBBO, multi-point sonication pattern (interleaved vs. serial) and microbubble injection method (bolus vs. infusion), were evaluated by treating mice with four combinations of these two parameters. 2D Passive cavitation imaging (PCI) was performed for monitoring the large-volume sonication. Results: Interleaved sonication combined with bolus injection of microbubbles resulted in 1.29 to 2.06 folds higher efficiency than other strategies as evaluated by Evans blue extravasation. The average coefficient of variation of the Evans blue delivery was 0.66 for interleaved sonication with bolus injection, compared to 0.68–0.88 for all other strategies. Similar trend was also observed in the quantified total cavitation dose and coefficient of variance of the cavitation dose. This strategy was then applied to deliver fluorescently labeled aPD-L1 which was quantified using fluorescence imaging. A strong segmented linear correlation ( R 2 = 0.81) was found between the total cavitation dose and the total fluorescence intensity of aPD-L1 delivered at different sonication pressures (0.15 MPa, 0.30 MPa, and 0.45 MPa). Significance: Findings from this study suggest that efficient and homogeneous large-volume FUS-BBBO can be achieved by interleaved sonication combined with bolus injection of microbubbles, and the efficiency and homogeneity can be monitored by PCI.
- 27 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (11) , 3449-3459
Comparison of Sonication Patterns and Microbubble Administration Strategies for Focused Ultrasound-Mediated Large-Volume Drug Delivery
Objective: Diffuse intrinsic pontine glioma (DIPG) is the most common and deadliest brainstem tumor in children. Focused ultrasound combined with microbubble-mediated BBB opening (FUS-BBBO) is a promising technique for overcoming the frequently intact blood-brain barrier (BBB) in DIPG to enhance therapeutic drug delivery to the brainstem. Since DIPG is highly diffusive, large-volume FUS-BBBO is needed to cover the entire tumor region. The objective of this study was to determine the optimal treatment strategy to achieve efficient and homogeneous large-volume BBBO at the brainstem for the delivery of an immune checkpoint inhibitor, anti-PD-L1 antibody (aPD-L1). Methods: Two critical parameters for large-volume FUS-BBBO, multi-point sonication pattern (interleaved vs. serial) and microbubble injection method (bolus vs. infusion), were evaluated by treating mice with four combinations of these two parameters. 2D Passive cavitation imaging (PCI) was performed for monitoring the large-volume sonication. Results: Interleaved sonication combined with bolus injection of microbubbles resulted in 1.29 to 2.06 folds higher efficiency than other strategies as evaluated by Evans blue extravasation. The average coefficient of variation of the Evans blue delivery was 0.66 for interleaved sonication with bolus injection, compared to 0.68–0.88 for all other strategies. Similar trend was also observed in the quantified total cavitation dose and coefficient of variance of the cavitation dose. This strategy was then applied to deliver fluorescently labeled aPD-L1 which was quantified using fluorescence imaging. A strong segmented linear correlation ( R 2 = 0.81) was found between the total cavitation dose and the total fluorescence intensity of aPD-L1 delivered at different sonication pressures (0.15 MPa, 0.30 MPa, and 0.45 MPa). Significance: Findings from this study suggest that efficient and homogeneous large-volume FUS-BBBO can be achieved by interleaved sonication combined with bolus injection of microbubbles, and the efficiency and homogeneity can be monitored by PCI.
- Open Access
- 1 January 2022
- Published by American Association for the Advancement of Science (AAAS) in BME Frontiers
- Vol. 2022
Blood-Brain Barrier Opening by Individualized Closed-Loop Feedback Control of Focused Ultrasound
Objective and Impact Statement . To develop an approach for individualized closed-loop feedback control of microbubble cavitation to achieve safe and effective focused ultrasound in combination with microbubble-induced blood-brain barrier opening (FUS-BBBO). Introduction . FUS-BBBO is a promising strategy for noninvasive and localized brain drug delivery with a growing number of clinical studies currently ongoing. Real-time cavitation monitoring and feedback control are critical to achieving safe and effective FUS-BBBO. However, feedback control algorithms used in the past were either open-loop or without consideration of baseline cavitation level difference among subjects. Methods . This study performed feedback-controlled FUS-BBBO by defining the target cavitation level based on the baseline stable cavitation level of an individual subject with “dummy” FUS sonication. The dummy FUS sonication applied FUS with a low acoustic pressure for a short duration in the presence of microbubbles to define the baseline stable cavitation level that took into consideration of individual differences in the detected cavitation emissions. FUS-BBBO was then achieved through two sonication phases: ramping-up phase to reach the target cavitation level and maintaining phase to control the stable cavitation level at the target cavitation level. Results . Evaluations performed in wild-type mice demonstrated that this approach achieved effective and safe trans-BBB delivery of a model drug. The drug delivery efficiency increased as the target cavitation level increased from 0.5 dB to 2 dB without causing vascular damage. Increasing the target cavitation level to 3 dB and 4 dB increased the probability of tissue damage. Conclusions . Safe and effective brain drug delivery was achieved using the individualized closed-loop feedback-controlled FUS-BBBO.
- 1 January 2022
- Published by American Association for the Advancement of Science (AAAS) in BME Frontiers
- Vol. 2022
Open AccessBlood-Brain Barrier Opening by Individualized Closed-Loop Feedback Control of Focused Ultrasound
Objective and Impact Statement . To develop an approach for individualized closed-loop feedback control of microbubble cavitation to achieve safe and effective focused ultrasound in combination with microbubble-induced blood-brain barrier opening (FUS-BBBO). Introduction . FUS-BBBO is a promising strategy for noninvasive and localized brain drug delivery with a growing number of clinical studies currently ongoing. Real-time cavitation monitoring and feedback control are critical to achieving safe and effective FUS-BBBO. However, feedback control algorithms used in the past were either open-loop or without consideration of baseline cavitation level difference among subjects. Methods . This study performed feedback-controlled FUS-BBBO by defining the target cavitation level based on the baseline stable cavitation level of an individual subject with “dummy” FUS sonication. The dummy FUS sonication applied FUS with a low acoustic pressure for a short duration in the presence of microbubbles to define the baseline stable cavitation level that took into consideration of individual differences in the detected cavitation emissions. FUS-BBBO was then achieved through two sonication phases: ramping-up phase to reach the target cavitation level and maintaining phase to control the stable cavitation level at the target cavitation level. Results . Evaluations performed in wild-type mice demonstrated that this approach achieved effective and safe trans-BBB delivery of a model drug. The drug delivery efficiency increased as the target cavitation level increased from 0.5 dB to 2 dB without causing vascular damage. Increasing the target cavitation level to 3 dB and 4 dB increased the probability of tissue damage. Conclusions . Safe and effective brain drug delivery was achieved using the individualized closed-loop feedback-controlled FUS-BBBO.
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A29-A30
Static magnetic fields dampen focused ultrasound-induced cavitation and blood-brain barrier opening outcome
MRI-guided focused ultrasound combined with microbubbles has been used in clinical studies for blood-brain barrier (BBB) opening. However, the impact of the static magnetic field generated by an MRI scanner on the BBB opening outcome has not been evaluated. The objective of this study was to determine the relationship of the static magnetic field of an MRI scanner on focused ultrasound combined with microbubble-induced BBB opening. Mice were divided into four groups which were sonicated by FUS in different static magnetic fields B0 (∼0T, 1.5T, 3.0T, and 4.7T) with all other experimental parameters kept the same. Microbubble cavitation activity was monitored by passive cavitation detection during FUS after microbubble injection. After sonication, contrast-enhanced T1-weighted MRI and Evans blue were used to evaluate the BBBO outcome. The microbubble cavitation dose decreased by an average of 2.1 dB at 1.5T (P = 0.05), 2.9 dB at 3.0T (Pi = 0.01), and 3.0 dB at 4.7T (P = 0.01) compared with that outside the magnetic field. It also decreased Evans blue trans-BBB delivery 1.4-fold at1.5T (P = 0.009), 1.6-fold at 3.0T (P < 0.001), and 1.9-fold at 4.7T (P < 0.001). These findings demonstrated that static magnetic fields dampened microbubble cavitation and decreased trans-BBB delivery by FUS.
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A29-A30
Static magnetic fields dampen focused ultrasound-induced cavitation and blood-brain barrier opening outcome
MRI-guided focused ultrasound combined with microbubbles has been used in clinical studies for blood-brain barrier (BBB) opening. However, the impact of the static magnetic field generated by an MRI scanner on the BBB opening outcome has not been evaluated. The objective of this study was to determine the relationship of the static magnetic field of an MRI scanner on focused ultrasound combined with microbubble-induced BBB opening. Mice were divided into four groups which were sonicated by FUS in different static magnetic fields B0 (∼0T, 1.5T, 3.0T, and 4.7T) with all other experimental parameters kept the same. Microbubble cavitation activity was monitored by passive cavitation detection during FUS after microbubble injection. After sonication, contrast-enhanced T1-weighted MRI and Evans blue were used to evaluate the BBBO outcome. The microbubble cavitation dose decreased by an average of 2.1 dB at 1.5T (P = 0.05), 2.9 dB at 3.0T (Pi = 0.01), and 3.0 dB at 4.7T (P = 0.01) compared with that outside the magnetic field. It also decreased Evans blue trans-BBB delivery 1.4-fold at1.5T (P = 0.009), 1.6-fold at 3.0T (P < 0.001), and 1.9-fold at 4.7T (P < 0.001). These findings demonstrated that static magnetic fields dampened microbubble cavitation and decreased trans-BBB delivery by FUS.
- 6 July 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 300 (3) , 681-689
Static Magnetic Fields Dampen Focused Ultrasound–mediated Blood-Brain Barrier Opening
The static magnetic field of an MRI scanner was found to dampen microbubble cavitation activity and decrease the focused ultrasound combined with microbubble-mediated blood-brain barrier opening. Background Focused ultrasound combined with microbubbles has been used in clinical studies for blood-brain barrier (BBB) opening in conjunction with MRI. However, the impact of the static magnetic ...
- 6 July 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 300 (3) , 681-689
Static Magnetic Fields Dampen Focused Ultrasound–mediated Blood-Brain Barrier Opening
The static magnetic field of an MRI scanner was found to dampen microbubble cavitation activity and decrease the focused ultrasound combined with microbubble-mediated blood-brain barrier opening. Background Focused ultrasound combined with microbubbles has been used in clinical studies for blood-brain barrier (BBB) opening in conjunction with MRI. However, the impact of the static magnetic ...