WLWei-Ching Lo

Wei-Ching Lo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wei-Ching Lo has a total of 75 co-authors. Here are the top co-authors by number of shared publications:

  • Susie Y. Huang

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States

    7 shared publications
  • Bryan Clifford

    Siemens Medical Solutions USA, Boston, USA

    6 shared publications
  • Dominik Nickel

    Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG Erlangen Germany

    4 shared publications
  • Sittaya Buathong

    From the Department of Radiology (C.-H.C., S.B., A.H., A.T., J.C., S.Y.H.), Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts

    4 shared publications
  • Azadeh Tabari

    From the Department of Radiology (C.-H.C., S.B., A.H., A.T., J.C., S.Y.H.), Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts

    3 shared publications
  • Chen-Hua Chiang

    From the Department of Radiology (C.-H.C., S.B., A.H., A.T., J.C., S.Y.H.), Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts

    3 shared publications

Latest Publications

  • Open Access

    Peripheral Nerve Stimulation Optimized Pulses for EPI (POPE) allows high-resolution fMRI

    by Laurentius Huber, Dominik Rattenbacher, Bastien Guerin, Haotian Hong, Alessandra Pizzuti, Omer Faruk Gulban, Wei-Ching Lo, Azma Mareyam, Kyle Droppa, Jinting Yao, et al.

    Purpose: Recent improvements in MRI gradient design and amplifiers, advanced MRI scanners are now routinely utilizing slew rates of several hundred T/m/s. However, full gradient performance cannot be exploited in high-resolution EPI due to peripheral nerve stimulation (PNS) limits. We aim to characterize and mitigate these PNS constraints using a simple sequence modification: PNS-optimized EPI gradient pulse shapes. Methods: PNS-Optimized Pulses for EPI (POPE): we selectively reduce the slew rate of gradient pulses at periods of high predicted PNS spikes, while leaving the rest of the waveform unchanged. Results: POPE allows 7%-35% faster imaging of EPI protocols resolutions of 1mm-0.3mm resolutions without exceeding predicted PNS. With such improvements, POPE allows robust 0.3 mm isotropic fMRI protocols that would have exceeded safety limits without it. Conclusion: POPE facilitates locally precise fMRI activation mapping on clinical 7T scanners at spatial resolution that were previously unattainable due to PNS limitations.


  • Clinical Evaluation of Deep Learning–Reconstructed Postcontrast 3D T1-Weighted Volume Interpolated Breath-Hold Examination (VIBE) Compared with Standard VIBE for Detection of Internal Auditory Canal Lesions

    by Chen-Hua Chiang, Sittaya Buathong, Azadeh Hajati, Azadeh Tabari, Wei-Ching Lo, Dominik Nickel, Bryan Clifford, Robert Sellers, Stephen F. Cauley, John Conklin, et al.

    Contrast-enhanced volume interpolated breath-hold examination (VIBE) is commonly used for evaluating internal auditory canal (IAC) pathology. Deep learning (DL)-reconstruction has been shown to reduce scan time while maintaining diagnostic quality. Our purpose was to compare the image quality of a DL-reconstructed post-contrast-enhanced VIBE sequence with standard 3D VIBE in a clinical setting. This study included 74 patients undergoing contrast-enhanced MRI for the assessment of IAC pathology. The participants were scanned with a standard 3D VIBE sequence and DL-reconstructed VIBE (DL-VIBE) sequences. Two neuroradiologists performed a head-to-head evaluation of both sequences in terms of image-quality metrics, identification of key anatomic structures, and pathologic enhancement when present. A third neuroradiologist adjudicated the discrepant results. Superiority testing was performed to compare DL-VIBE with standard VIBE in image quality metrics, and a noninferiority test with a 15% margin was performed to test the visibility of key anatomic structures and pathologic enhancing lesions. Interrater agreement and quantitative assessment of an image-wise SNR, contrast-noise ratio, IAC-specific SNR, and tumor volumetric measurements as applicable were performed. DL-VIBE enabled approximately 25% scan time reduction (from 3 minutes 2 seconds on the standard sequence to 2 minutes 17 seconds on the DL sequence). DL-VIBE was superior to standard VIBE for all image-quality metrics (P < .01). DL-VIBE was noninferior to standard VIBE for structural visibility of key structures (P < .001) and was noninferior for pooled pathologic enhancement (P = .049). Interrater agreements were moderate to almost perfect across all categories (κ = 0.515-1). DL-VIBE provided significantly higher mean image-wise SNR (71.8 [SD, 23.2] versus 39.4 [SD, 10.7], respectively; P < .001), while providing comparable lesion conspicuity and volumetric assessment. DL-VIBE is a strong alternative to standard 3D VIBE for clinical IAC assessment, providing superior image quality and comparable visibility of key anatomic structures and enhancing pathology while offering higher image SNR with 25% reduced scan time.


  • Clinical Evaluation of Scout Accelerated Motion Estimation and Reduction (SAMER) Motion-Corrected 2D T2-Weighted TSE 3T Brain MRI in the Neurologic Intensive Care Unit

    by Azadeh Hajati, Chen-Hua Chiang, Sittaya Buathong, Azadeh Tabari, Seonghwan Yee, Daniel Polak, Daniel Nicolas Splitthoff, Bryan Clifford, Wei-Ching Lo, Yantu Huang, et al.


  • Clinical Validation of Deep Learning–Accelerated versus Wave-CAIPI Postcontrast 3D T1-MPRAGE for Evaluation of Intracranial Enhancing Lesions

    by Azadeh Tabari, Maryam Vejdani-Jahromi, Min Lang, Dominik Nickel, Wei-Ching Lo, Bryan Clifford, John Conklin, Susie Y. Huang

    Deep learning (DL) reconstruction methods have shown promise in accelerating 2D MRI sequences but have yet to be extensively validated for routine 3D volumetric MRI applications. Our purpose was to assess the diagnostic quality of a novel DL-accelerated 3D T1-MPRAGE compared with a state-of-the-art wave-controlled aliasing in parallel imaging (Wave-CAIPI) accelerated 3D T1-MPRAGE for evaluating intracranial enhancing lesions. This prospective study was approved by the Institutional Review Board. Patients undergoing contrast-enhanced brain MRI in an outpatient setting were scanned on 3T MRI systems. The imaging protocol included a state-of-the-art Wave-CAIPI postcontrast T1-MPRAGE (acceleration factor [R] = 2 × 2, acquisition time [TA] = 2:11 minutes) and a research-based postcontrast DL-T1-MPRAGE (R = 2 × 2, TA = 2:11 minutes). The DL-based reconstruction process involved 2 steps. The first step, inspired by variational networks, involved 6 iterations alternating between data consistency updates and neural network evaluation. The second step applied a super-resolution algorithm for further image enhancement. Two independent neuroradiologists conducted a blinded, randomized head-to-head comparison of the 2 sequences by using a previously published scale across the following criteria: visualization of dural, parenchymal, leptomeningeal, and ependymal enhancement; sharpness; noise; artifacts; and overall diagnostic quality. A third board-certified neuroradiologist adjudicated cases with discrepant ratings. Noninferiority of DL-T1-MPRAGE was tested by using a 15% margin. A total of 115 patients (68 women/47 men, mean age = 54 ± 10 years) were included. The top 3 clinical indications were: neoplasm (52%), vascular lesions (24%), and headache (8%). DL-T1-MPRAGE was noninferior to Wave-CAIPI T1-MPRAGE for delineating enhancing lesions with unanimous agreement in all cases with enhancing pathology. It was also noninferior in terms of noise perception (P < .0001), artifact (P < .0001), sharpness (P = .001), and overall diagnostic quality (P < .0001). DL-T1-MPRAGE provided equivalent visualization of small, subtle enhancing parenchymal, dural, and leptomeningeal lesions. The highly accelerated postcontrast DL-T1-MPRAGE demonstrated noninferior image quality compared with the clinically validated Wave-CAIPI T1-MPRAGE accelerated sequence while offering enhanced visualization of subtle enhancing lesions.

  • Motion-Informed 3D Deep Learning Reconstruction in Patients with Cognitive Impairment

    by Shohei Fujita, Daniel Polak, Dominik Nickel, Daniel Nicolas Splitthoff, Yantu Huang, Nelson Gil, Sittaya Buathong, Chen-Hua Chiang, Wei-Ching Lo, Bryan Clifford, et al.

    BACKGROUND AND PURPOSE: Motion artifacts remain a key limitation in brain MRI, particularly during 3D acquisitions in cognitively impaired patients. Most deep learning (DL) reconstruction techniques improve signal-to-noise ratio but lack explicit mechanisms to correct for motion. This study aims to validate a DL reconstruction method that integrates retrospective motion correction into the reconstruction pipeline for 3D T1-weighted brain MRI. MATERIALS AND METHODS: This prospective, intra-individual comparison study included a controlled-motion cohort of healthy volunteers and a clinical cohort of patients undergoing evaluation for memory loss. Each cohort was scanned at distinct imaging sites between October 2022 and August 2023 in staggered periods. All participants underwent 4-fold under-sampled 3D magnetization-prepared rapid gradient-echo imaging with integrated Scout Accelerated Motion Estimation and Reduction (SAMER) acquisition. Image volumes were reconstructed using standard-of-care methods and the proposed DL approach. Quantitative morphometric accuracy was assessed by comparing brain segmentation results of instructed-motion scans to motion-free reference scans in the healthy volunteers. Image quality was rated by two board-certified neuroradiologists using a five-point Likert scale. Statistical analysis included Wilcoxon tests and intraclass correlation coefficients. RESULTS: A total of 41 participants (15 women [37%]; mean age, 58 years) and 154 image volumes were evaluated. The DL-based method with integrated motion correction significantly reduced segmentation error under moderate and severe motion (12.4% to 3.5% and 44.2% to 12.5%, respectively; P < .001). Visual ratings showed improved scores across all criteria compared with standard reconstructions (overall image quality, 4.26 ± 0.72 vs. 3.59 ± 0.82; P < .001). In 47% of cases, motion artifact severity was improved following DL-based processing. Inter-reader agreement ranged from moderate to substantial. CONCLUSIONS: Motion-informed DL reconstruction improved both morphometric accuracy and perceived image quality in 3D T1-weighted brain MRI. This technique may enhance diagnostic utility and reduce scan failure rates in motion-prone patients with cognitive impairment. ABBREVIATIONS: AD = Alzheimer’s disease; DL = deep learning; ICC = intra-class correlation coefficient; SAMER = scout accelerated motion estimation and reduction


  • Open Access

    Physics-informed deep learning reconstruction for ultrafast clinical 3D fluid-attenuated inversion recovery brain MRI

    by Shohei Fujita, Dominik Nickel, Wei-Ching Lo, Bryan Clifford, Stephen Cauley, Sittaya Buathong, Azadeh Hajati, Florence L Chiang, John Conklin, Susie Y Huang

    Background: Physics-informed deep learning (DL) reconstructions show promise in accelerating MRI yet have not been extensively validated, particularly for 3D fluid-attenuated inversion recovery (FLAIR) sequence. Purpose: To evaluate the diagnostic quality and interchangeability of DL-based 3D FLAIR with a state-of-the-art acceleration technique (wave-controlled aliasing in parallel imaging [Wave-CAIPI] FLAIR) in a clinical setting with 3 T brain MRI. Materials and Methods: Participants undergoing evaluation for demyelinating disease between October and December of 2023 were prospectively enrolled at a single center. For each participant, state-of-the-art Wave-CAIPI FLAIR and a resolution-matched 6-fold-under-sampled Cartesian FLAIR acquisition with DL reconstruction were performed at 3-T system (MAGNETOM Vida, Siemens Healthineers, Erlangen, Germany). Four neuroradiologists evaluated overall image quality, anatomic conspicuity, lesion conspicuity, and imaging artifacts. Lesion count, volume, and regional brain volume were compared between imaging methods. Inter-reader agreement was assessed using quadratic weighted Cohen’s kappa and Kendall’s correlation coefficient. Agreement of continuous metrics was evaluated using intraclass correlation coefficients (ICCs), linear regression, and Bland-Altman analysis. Interchangeability regarding the quantitative metrics was evaluated with individual equivalence index (IEI). Results: Totally, 88 participants (61 women [69%], 47 ± 13 years) were evaluated. DL-FLAIR reduced scan time (1:53 vs. 2:50) and showed higher overall image quality, anatomic conspicuity, lesion conspicuity, and imaging artifacts compared with state-of-the-art technique (all Ps < .001). DL-FLAIR also demonstrated higher signal-to-noise ratio and contrast-to-noise ratio compared to Wave-CAIPI-FLAIR, with high agreement in lesion and regional brain volumes between both methods (ICC(2, k) range, 0.91 to 0.99). DL-FLAIR proved interchangeable with Wave-CAIPI-FLAIR for lesion count (IEI: 0.10, acceptable proportion: 0.977, 95% CI: [0.943, 1.000]) and for lesion volume (IEI: 0.32, acceptable proportion: 0.966, 95% CI: [0.930, 1.000]). Conclusion: Deep learning reconstruction of 3D-FLAIR provides higher image quality compared to a state-of-the-art technique with 30% less scan time while maintaining excellent agreement and interchangeability in quantitative evaluation.


  • Open Access

    Clinical Evaluation of a 2-Minute Ultrafast Brain MR Protocol for Evaluation of Acute Pathology in the Emergency and Inpatient Settings

    by Min Lang, Bryan Clifford, Wei-Ching Lo, Brooks P. Applewhite, Azadeh Tabari, Augusto Lio M. Goncalves Filho, Zahra Hosseini, Maria Gabriela Figueiro Longo, Stephen F. Cauley, Kawin Setsompop, et al.

    BACKGROUND AND PURPOSE: The use of MR imaging in emergency settings has been limited by availability, long scan times, and sensitivity to motion. This study assessed the diagnostic performance of an ultrafast brain MR imaging protocol for evaluation of acute intracranial pathology in the emergency department and inpatient settings. MATERIALS AND METHODS: Sixty-six adult patients who underwent brain MR imaging in the emergency department and inpatient settings were included in the study. All patients underwent both the reference and the ultrafast brain MR protocols. Both brain MR imaging protocols consisted of T1-weighted, T2/T2*-weighted, FLAIR, and DWI sequences. The ultrafast MR images were reconstructed by using a machine-learning assisted framework. All images were reviewed by 2 blinded neuroradiologists. RESULTS: The average acquisition time was 2.1 minutes for the ultrafast brain MR protocol and 10 minutes for the reference brain MR protocol. There was 98.5% agreement on the main clinical diagnosis between the 2 protocols. In head-to-head comparison, the reference protocol was preferred in terms of image noise and geometric distortion (P < .05 for both). The ultrafast ms-EPI protocol was preferred over the reference protocol in terms of reduced motion artifacts (P < .01). Overall diagnostic quality was not significantly different between the 2 protocols (P > .05). CONCLUSIONS: The ultrafast brain MR imaging protocol provides high accuracy for evaluating acute pathology while only requiring a fraction of the scan time. Although there was greater image noise and geometric distortion on the ultrafast brain MR protocol images, there was significant reduction in motion artifacts with similar overall diagnostic quality between the 2 protocols.


  • Open Access

    Multicenter Repeatability and Reproducibility of MR Fingerprinting in Phantoms and in Prostatic Tissue

    by Wei‐Ching Lo, Leonardo Kayat Bittencourt, Ananya Panda, Yun Jiang, Junichi Tokuda, Ravi Seethamraju, Clare Tempany‐Afdhal, Verena Obmann, Katherine Wright, Mark Griswold, et al.

    Purpose: To evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues.Methods: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron‐based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same‐day test–retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland–Altman analysis.Results: The intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2. Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test–retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2 > 0.840).Conclusion: Prostate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.


  • Automated detection and reacquisition of motion‐degraded images in fetal HASTE imaging at 3 T

    by Borjan Gagoski, Junshen Xu, Paul Wighton, M. Dylan Tisdall, Robert Frost, Wei‐Ching Lo, Polina Golland, Andre van der Kouwe, Elfar Adalsteinsson, P. Ellen Grant

    Purpose: Fetal brain Magnetic Resonance Imaging suffers from unpredictable and unconstrained fetal motion that causes severe image artifacts even with half‐Fourier single‐shot fast spin echo (HASTE) readouts. This work presents the implementation of a closed‐loop pipeline that automatically detects and reacquires HASTE images that were degraded by fetal motion without any human interaction.Methods: A convolutional neural network that performs automatic image quality assessment (IQA) was run on an external GPU‐equipped computer that was connected to the internal network of the MRI scanner. The modified HASTE pulse sequence sent each image to the external computer, where the IQA convolutional neural network evaluated it, and then the IQA score was sent back to the sequence. At the end of the HASTE stack, the IQA scores from all the slices were sorted, and only slices with the lowest scores (corresponding to the slices with worst image quality) were reacquired.Results: The closed‐loop HASTE acquisition framework was tested on 10 pregnant mothers, for a total of 73 acquisitions of our modified HASTE sequence. The IQA convolutional neural network, which was successfully employed by our modified sequence in real time, achieved an accuracy of 85.2% and area under the receiver operator characteristic of 0.899.Conclusion: The proposed acquisition/reconstruction pipeline was shown to successfully identify and automatically reacquire only the motion degraded fetal brain HASTE slices in the prescribed stack. This minimizes the overall time spent on HASTE acquisitions by avoiding the need to repeat the entire stack if only few slices in the stack are motion‐degraded.


  • Evaluation of Ultrafast Wave–Controlled Aliasing in Parallel Imaging 3D-FLAIR in the Visualization and Volumetric Estimation of Cerebral White Matter Lesions

    by C. Ngamsombat, A.L.M. Gonçalves Filho, M.G.F. Longo, S.F. Cauley, K. Setsompop, J.E. Kirsch, Q. Tian, Q. Fan, D. Polak, W. Liu, et al.

    BACKGROUND AND PURPOSE: Our aim was to evaluate an ultrafast 3D-FLAIR sequence using Wave–controlled aliasing in parallel imaging encoding (Wave-FLAIR) compared with standard 3D-FLAIR in the visualization and volumetric estimation of cerebral white matter lesions in a clinical setting. MATERIALS AND METHODS: Forty-two consecutive patients underwent 3T brain MR imaging, including standard 3D-FLAIR (acceleration factor = 2, scan time = 7 minutes 50 seconds) and resolution-matched ultrafast Wave-FLAIR sequences (acceleration factor = 6, scan time = 2 minutes 45 seconds for the 20-channel coil; acceleration factor = 9, scan time = 1 minute 50 seconds for the 32-channel coil) as part of clinical evaluation for demyelinating disease. Automated segmentation of cerebral white matter lesions was performed using the Lesion Segmentation Tool in SPM. Student t tests, intraclass correlation coefficients, relative lesion volume difference, and Dice similarity coefficients were used to compare volumetric measurements among sequences. Two blinded neuroradiologists evaluated the visualization of white matter lesions, artifacts, and overall diagnostic quality using a predefined 5-point scale. RESULTS: Standard and Wave-FLAIR sequences showed excellent agreement of lesion volumes with an intraclass correlation coefficient of 0.99 and mean Dice similarity coefficient of 0.97 (SD, 0.05) (range, 0.84–0.99). Wave-FLAIR was noninferior to standard FLAIR for visualization of lesions and motion. The diagnostic quality for Wave-FLAIR was slightly greater than for standard FLAIR for infratentorial lesions (P < .001), and there were fewer pulsation artifacts on Wave-FLAIR compared with standard FLAIR (P < .001). CONCLUSIONS: Ultrafast Wave-FLAIR provides superior visualization of infratentorial lesions while preserving overall diagnostic quality and yields white matter lesion volumes comparable with those estimated using standard FLAIR. The availability of ultrafast Wave-FLAIR may facilitate the greater use of 3D-FLAIR sequences in the evaluation of patients with suspected demyelinating disease.