Clinical Evaluation of a 2-Minute Ultrafast Brain MR Protocol for Evaluation of Acute Pathology in the Emergency and Inpatient Settings
Authors:
- Min LangMin Lang
- Bryan CliffordBCBryan Clifford
- Wei-Ching LoWLWei-Ching Lo
- Brooks P. ApplewhiteBABrooks P. Applewhite
- Augusto Lio M. Goncalves FilhoAFAugusto Lio M. Goncalves Filho
- Zahra HosseiniZHZahra Hosseini
- Maria Gabriela Figueiro LongoMLMaria Gabriela Figueiro Longo
- Stephen F. CauleySCStephen F. Cauley
- Kawin SetsompopKSKawin Setsompop
- Berkin BilgicBBBerkin Bilgic
- Thorsten FeiweierTFThorsten Feiweier
Open Access
- 7 March 2024
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (4) , 379-385
Abstract
BACKGROUND AND PURPOSE: The use of MR imaging in emergency settings has been limited by availability, long scan times, and sensitivity to motion. This study assessed the diagnostic performance of an ultrafast brain MR imaging protocol for evaluation of acute intracranial pathology in the emergency department and inpatient settings. MATERIALS AND METHODS: Sixty-six adult patients who underwent brain MR imaging in the emergency department and inpatient settings were included in the study. All patients underwent both the reference and the ultrafast brain MR protocols. Both brain MR imaging protocols consisted of T1-weighted, T2/T2*-weighted, FLAIR, and DWI sequences. The ultrafast MR images were reconstructed by using a machine-learning assisted framework. All images were reviewed by 2 blinded neuroradiologists. RESULTS: The average acquisition time was 2.1 minutes for the ultrafast brain MR protocol and 10 minutes for the reference brain MR protocol. There was 98.5% agreement on the main clinical diagnosis between the 2 protocols. In head-to-head comparison, the reference protocol was preferred in terms of image noise and geometric distortion (P < .05 for both). The ultrafast ms-EPI protocol was preferred over the reference protocol in terms of reduced motion artifacts (P < .01). Overall diagnostic quality was not significantly different between the 2 protocols (P > .05). CONCLUSIONS: The ultrafast brain MR imaging protocol provides high accuracy for evaluating acute pathology while only requiring a fraction of the scan time. Although there was greater image noise and geometric distortion on the ultrafast brain MR protocol images, there was significant reduction in motion artifacts with similar overall diagnostic quality between the 2 protocols.Keywords
Funding Information
- Siemens Healthineers
- RSNA Research and Education Foundation (Seed Grant)
- National Institutes of Health (P41EB030006)
This publication has 34 references indexed in Scilit:
- Ultrafast Brain MRI Protocol at 1.5 T Using Deep Learning and Multi-shot EPIAcademic Radiology, 2023
- Ultrafast MRI using deep learning echoplanar imaging for a comprehensive assessment of acute ischemic strokeEuropean Radiology, 2023
- An artificial intelligence‐accelerated 2‐minute multi‐shot echo planar imaging protocol for comprehensive high‐quality clinical brain imagingMagnetic Resonance in Medicine, 2021
- Interventions to Reduce Hospital Length of Stay in High-risk PopulationsJAMA Network Open, 2021
- One‐Minute Multi‐contrast Echo Planar Brain MRI in Ischemic Stroke: A Retrospective Observational Study of Diagnostic PerformanceJournal of Magnetic Resonance Imaging, 2021
- Highly accelerated multishot echo planar imaging through synergistic machine learning and joint reconstructionMagnetic Resonance in Medicine, 2019
- Diagnostic performance of a new multicontrast one‐minute full brain exam (EPIMix) in neuroradiology: A prospective studyJournal of Magnetic Resonance Imaging, 2019
- A 1‐minute full brain MR exam using a multicontrast EPI sequenceMagnetic Resonance in Medicine, 2017
- DWI using navigated interleaved multishot EPI with realigned GRAPPA reconstructionMagnetic Resonance in Medicine, 2015
- Fast spin-echo MR imaging of the pediatric brainPediatric Radiology, 1996