RQRonghuai Qi

Ronghuai Qi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ronghuai Qi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Engineering a Viscoelastic Alginate–Konjac Glucomannan Bioink through Controlled Ionic Gelation for Functional 3D Bioprinting and Tissue Engineering

    by Lina R. Nih, Ivy Pham, Jeong Kim, Saba Majidi, Sunjeet Saha, Dongyoung Kim, Nikita Gopakumar, Amarnath Singam, Ronghuai Qi, Jaeyun Moon, et al.

    Three-dimensional (3D) bioprinting requires bioinks that combine precise printability with biologically functional microenvironments capable of supporting engineered tissue formation. Conventional alginate bioinks often fail to achieve this balance because rapid ionic gelation limits mechanical control and cellular function. Here, we developed a viscoelastic alginate–konjac glucomannan (KGM) bioink using controlled CaSO₄-mediated ionic gelation and polymer reinforcement. Controlled crosslinking generated homogeneous hydrogel networks with tunable viscoelasticity, while KGM enhanced matrix stability through polymer entanglement. The resulting bioinks exhibited high shape fidelity, robust extrusion performance, and structural stability for engineered tissue constructs. The engineered microenvironment promoted cell spreading, proliferation, and RGD-independent adhesion despite lacking canonical adhesive ligands. Label-free holotomographic imaging further demonstrated preserved intracellular organelle dynamics and active lipid droplet transport, indicating sustained cellular metabolism. Collectively, this work establishes a generalizable strategy for engineering biologically functional bioinks for tissue engineering, regenerative medicine, disease modeling, and mechanobiology.

  • Image-Based Force Localization and Estimation of a Micro-Scale Continuum Guidewire Robot

    by Timothy A. Brumfiel, Ronghuai Qi, Sharan Ravigopal, Jaydev P. Desai

    Many intravascular procedures are prefaced by the placement of a slender wire called a guidewire. Steering these guidewires is met with challenges in controlling the distal end along with the possibility of damaging vessel walls, or even perforation, which can be fatal. To this end, utilizing robotic guidewires can improve steerability and enable force feedback through intrinsic force sensing. Enabling force sensing contains challenges such as discrete sensor placements in continuous structures and non-unique force distributions for a given deflection. In this work, we utilize image feedback and a Cosserat rod model to estimate and localize forces along the body of a micro-scale tendon-driven guidewire robot. This includes additional modeling of friction and hysteresis that is often neglected for force sensing. The model is tested on a variety of notched nitinol tubes under gravity loading with the shape predictions having an average RMSE of 0.46 mm. Utilization of friction and hysteresis models provide shape predictions with an RMSE of 1.22 mm compared to an uncompensated model (RMSE ${=}$ 1.62 mm) for approximately 180° bends. The methods presented are able to localize forces with an average error of 4.79 mm (5.15% of the length) while force magnitudes are estimated with an average error of 13.03 mN.


  • Preclinical Evaluation of a Novel Steerable Robotic Neuroendoscope Tool

    by Kent K. Yamamoto, Timothy A. Brumfiel, Ronghuai Qi, Joshua J. Chern, Jaydev P. Desai

    BACKGROUND AND OBJECTIVES: To improve the outcomes of minimally invasive, endoscopic, intracranial procedures, steerable robotic tools have been developed but still require thorough evaluation before use in a clinical setting. This paper compares a novel steerable robotic neuroendoscope tool against a standard rigid tool. METHODS: Seventeen participants, 8 nonmedical and 9 medical (neurosurgery residents and fellows), were recruited. The evaluation trial consisted of a task that was completed using either a rigid tool or the steerable tool, followed by the completion of a qualitative survey. Target reach time and tool movement volume (TMV) were recorded for each trial and analyzed. The tools were evaluated within a realistic phantom model of the brain. RESULTS: Preclinical evaluation of both tools showed that average target reach time for the steerable tool among medical personnel (15.0 seconds) was longer than that of the rigid tool (5.9 seconds). However, the average TMV for the steerable tool (0.178 cm3) was much lower than that of the rigid tool (0.501 cm3) for medical personnel, decreasing the TMV by 64.47%. CONCLUSION: The steerable tool required more training and practice in comparison with the standard rigid tool, but it decreased the overall endoscope movement volume, which is a source of parenchymal injury associated with endoscopic procedures.


  • Design and Modeling of a Sub-2 mm Steerable Neuroendoscopic Grasping Tool

    by Timothy A. Brumfiel, Ronghuai Qi, Coley Chapman, Asif Rashid, Shreyes N. Melkote, Joshua J. Chern, Jaydev P. Desai

    Minimally invasive procedures, such as endoscopic third ventriculostomy (ETV), benefit from the increased dexterity and safety that surgical continuum robots can bring. However, due to their natural compliance, new compatible end-effectors, such as graspers or scissors, must be developed and their actuation must be considered when developing the robotic structures in which they are housed due to the inherent coupling that will be introduced. In this paper, we integrate a tendon-driven meso-scale grasper, with a closed configuration diameter of 1.69 mm, into a 2 degree-of-freedom (DoF) tendon-driven neurosurgical robot with an outer diameter of less than 2 mm. Furthermore, the kinematics of the grasper is validated and an analysis of the coupling between the grasper and the robotic joints is conducted in order to evaluate the design performance.


  • Compact Design and Task Space Control of a Robotic Transcatheter Delivery System for Mitral Valve Implant

    by Ronghuai Qi, Namrata U. Nayar, Jaydev P. Desai

    Mitral regurgitation (MR) is one of the most common valvular abnormalities, and the gold-standard for treatment is surgical mitral valve repair/replacement. Most patients with severe MR are over the age of 75, which makes open-heart surgery challenging. Thus, minimally invasive surgeries using transcatheter approaches are gaining popularity. This paper proposes the next generation of a robotic transcatheter delivery system for the mitral valve implant that focuses on the design of the actuation system, modeling, and task space control. The proposed actuation system is compact while still enabling bidirectional torsion, bending, and prismatic joint motion. A pulley structure is employed to actuate the torsion and bending joints using only one motor per joint in conjunction with an antagonistic passive spring to reduce tendon slack. The robotic transcatheter is also optimized to increase its stability and reduce bending deflection. An inverse kinematics model (with an optimization algorithm), singularity analysis method, and joint hysteresis and compensation model are developed and verified. Finally, a task space controller is also proposed. Experiments, including trajectory tracking and demonstrations of the robot motion in an ex vivo porcine heart and a phantom heart through a tortuous path are presented.


  • Telerobotic Transcatheter Delivery System for Mitral Valve Implant

    by Ronghuai Qi, Namrata U. Nayar, Jaydev P. Desai

    Mitral regurgitation (MR) is the most common type of valvular heart disease, affecting over 2% of the world population, and the gold-standard treatment is surgical mitral valve repair/replacement. Compared to open-heart surgeries, minimally invasive surgeries (MIS) using transcatheter approaches have become popular because of their notable benefits such as less postoperative pain, shorter hospital stay, and faster recovery time. However, commercially available catheters are manually actuated, causing over-exposure of clinical staff to radiation and increased risk of human error during medical interventions. To tackle this problem, in this letter, we propose a telerobotic transcatheter delivery system, which consists of a robotic catheter (5.7 mm OD), a reinforced guide tube (1.11 m length), and an actuation system. We present the robotic system design, fabrication of key components, and static model of reinforced quadlumen tube. The robot interface design enables the user to intuitively control the robot. We demonstrate the effectiveness of the telerobotic transcatheter delivery system and reinforced quadlumen tube in a realistic human cardiovascular phantom for preclinical evaluation.


  • Toward the Design and Development of a Robotic Transcatheter Delivery System for Mitral Valve Implant

    by Namrata U. Nayar, Ronghuai Qi, Jaydev P. Desai

    Minimally-invasive surgeries using transcatheter approaches and sophisticated imaging modalities are gaining popularity to treat mitral regurgitation (MR). This paper proposes the next generation of a robotic catheter to deliver an implant onto the mitral valve (MV) through a transseptal approach. The proposed robot has an outer diameter (OD) of 5.7 mm, a rigid distal end length of 20 mm, a prismatic tube that can be advanced by 50-60 mm, and a bending joint that can easily bend 120° to reach the valve opening. The implant can be rotated 75° bidirectionally by the distal torsion joint to orient it with the MV leaflet for precise implantation. The robotic joints are modeled individually, the forward and inverse kinematics are derived, and the robot motion validation is carried out through experimentation. A modified kinematics (MK) model, Prandtl-Ishlinskii (PI) hysteresis model, and hybrid of MK and PI model are used to compensate for the catheter nonlinearities. A preliminary study is conducted to evaluate if force sensing can be used to compensate for the effects of fluid flow. Also, the implantation procedure is demonstrated in a phantom heart.


  • Open Access

    Redundancy Resolution and Disturbance Rejection via Torque Optimization in Hybrid Cable-Driven Robots

    by Ronghuai Qi, Amir Khajepour, William W. Melek

    This article presents redundancy resolution and disturbance rejection via torque optimization in hybrid cable-driven robots (HCDRs). To begin with, we present a redundant HCDR for nonlinear whole-body system modeling and model reduction. Based on the reduced dynamic model, two new methods are proposed to solve the redundancy resolution problem: 1) joint-space torque optimization for actuated joints (TOAJ) and 2) joint-space torque optimization for actuated and unactuated joints (TOAUJ), and they can be extended to other HCDRs. Compared to the existing approaches, this article provides the first solution (TOAUJ-based method) for HCDRs that can solve the redundancy resolution problem as well as disturbance rejection. Additionally, this article develops detailed algorithms targeting TOAJ and TOAUJ implementation. A simple yet effective controller is designed for analysis and validation. Case studies are conducted to evaluate the performance of TOAJ and TOAUJ. The results show the effectiveness of the aforementioned approaches.


  • Open Access

    Redundancy Resolution and Disturbance Rejection via Torque Optimization in Hybrid Cable-Driven Robots

    by Ronghuai Qi, Amir Khajepour, William W. Melek

    This paper presents redundancy resolution and disturbance rejection via torque optimization in Hybrid Cable-Driven Robots (HCDRs). To begin with, we initiate a redundant HCDR for nonlinear whole-body system modeling and model reduction. Based on the reduced dynamic model, two new methods are proposed to solve the redundancy resolution problem: joint-space torque optimization for actuated joints (TOAJ) and joint-space torque optimization for actuated and unactuated joints (TOAUJ), and they can be extended to other HCDRs. Compared to the existing approaches, this paper provides the first solution (TOAUJ-based method) for HCDRs that can solve the redundancy resolution problem as well as disturbance rejection. Additionally, this paper develops detailed algorithms targeting TOAJ and TOAUJ implementation. A simple yet effective controller is designed for generated data analysis and validation. Case studies are conducted to evaluate the performance of TOAJ and TOAUJ, and the results suggest the effectiveness of the aforementioned approaches.

  • Open Access

    Generalized Flexible Hybrid Cable-Driven Robot (HCDR): Modeling, Control, and Analysis

    by Ronghuai Qi, Amir Khajepour, William W. Melek

    This paper presents a generalized flexible Hybrid Cable-Driven Robot (HCDR). For the proposed HCDR, the derivation of the equations of motion and proof provide a very effective way to find items for generalized system modeling. The proposed dynamic modeling approach avoids the drawback of traditional methods and can be easily extended to other types of hybrid robots, such as a robot arm mounted on an aircraft platform. Additionally, another goal of this paper is to develop integrated control systems to reduce vibrations and improve the accuracy and performance of the HCDR. To achieve this goal, redundancy resolution, stiffness optimization, and control strategies are studied. The proposed optimization problem and algorithm address the limitations of existing stiffness optimization approaches. Three types of control architecture are proposed, and their performances (i.e., reducing undesirable vibrations and trajectory tracking errors, especially for the end-effector) are evaluated using several well-designed case studies. Results show that the fully integrated control strategy can improve the tracking performance of the end-effector significantly.