Namrata U. Nayar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Namrata U. Nayar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Jaydev P. Desai
Georgia Institute of Technology
6 shared publications - Ronghuai Qi
Wallace H. Coulter Department of Biomedical Engineering, Medical Robotics and Automation Laboratory, Georgia Institute of Technology, Atlanta, GA, USA
3 shared publications Léa Pistorius
Department of Cardiac Surgery, Boston Childrens Hospital, Harvard Medical School, Boston, MA, USA
1 shared publication- Phillip Tran
Medical Robotics and Automation (RoboMed) Laboratory, Georgia Center for Medical Robotics, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication - Pierre E. Dupont
Department of Cardiac Surgery, Boston Children’s Hospital, Harvard Medical School, Boston, MA 02115, USA
1 shared publication - Sammy Elmariah
Cardiology Division, University of California, San Francisco (S.E.).
1 shared publication
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (7) , 8463-8470
Using Robotics to Improve Transcatheter Edge-to-Edge Repair of the Mitral Valve
Transcatheter valve repair presents significant challenges due to the mechanical limitations and steep learning curve associated with manual catheter systems. This paper investigates the use of robotics to facilitate transcatheter procedures in the context of mitral valve edge-to-edge repair. Specifically, the study builds upon the MitraClip™ (Abbott, USA), a widely used commercial system for mitral valve repair, adapting it for robotic actuation to evaluate potential performance improvements. The complex handle-based control of a clinical repair device is replaced by intuitive robotic joint-based control via a game controller. Manual versus robotic performance is analyzed by decomposing the overall device delivery task into motion-specific steps and comparing capabilities on a step-by-step basis in a phantom model of the heart and vasculature. Metrics include procedure duration and clip placement accuracy. Results demonstrate that the robotic system can reduce procedural time and motion errors while also improving accuracy of clip placement. For the most commonly treated middle leaflet segment, mean delivery time is reduced from 146.6sec to 76.2sec while mean clip positioning error is reduced from 3.1mm to 0.6mm. These findings suggest that robotic assistance can address key limitations of manual systems, offering a more reliable and user-friendly platform for complex transcatheter procedures.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (7) , 8463-8470
Using Robotics to Improve Transcatheter Edge-to-Edge Repair of the Mitral Valve
Transcatheter valve repair presents significant challenges due to the mechanical limitations and steep learning curve associated with manual catheter systems. This paper investigates the use of robotics to facilitate transcatheter procedures in the context of mitral valve edge-to-edge repair. Specifically, the study builds upon the MitraClip™ (Abbott, USA), a widely used commercial system for mitral valve repair, adapting it for robotic actuation to evaluate potential performance improvements. The complex handle-based control of a clinical repair device is replaced by intuitive robotic joint-based control via a game controller. Manual versus robotic performance is analyzed by decomposing the overall device delivery task into motion-specific steps and comparing capabilities on a step-by-step basis in a phantom model of the heart and vasculature. Metrics include procedure duration and clip placement accuracy. Results demonstrate that the robotic system can reduce procedural time and motion errors while also improving accuracy of clip placement. For the most commonly treated middle leaflet segment, mean delivery time is reduced from 146.6sec to 76.2sec while mean clip positioning error is reduced from 3.1mm to 0.6mm. These findings suggest that robotic assistance can address key limitations of manual systems, offering a more reliable and user-friendly platform for complex transcatheter procedures.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (9) , 7677-7684
Ultrasound-Guided Real-Time Joint Space Control of a Robotic Transcatheter Delivery System
Transcatheter mitral valve repair (TMVr) is growing in popularity for non-surgical mitral regurgitation (MR) patients, but the manual operation of current TMVr devices increases radiation exposure and limits telesurgery feasibility. A robotically steerable delivery system can alleviate these problems, improving safety and precision while reducing staff fatigue. However, precise manipulation of a surgical robotic system requires system modeling and reliable external feedback. Ultrasound imaging provides visualization and guidance for precise instrument maneuvers within the body. Moreover, it is a readily available, safe, and cost-effective feedback modality, ideal for this procedure. Therefore, in this work, we use a previously derived model for the robotic transcatheter system and perform ultrasound-guided joint space control through real-time (algorithm run time: $\sim$ 0.011 s) estimation of four joints simultaneously. The joints are estimated using kinematically-derived weight maps, a new technique, and a feature detection algorithm, with an accuracy of 3.19$^\circ$, 2.76$^\circ$, 2.41 mm, and 6.83$^\circ$ for the proximal bending, distal bending, prismatic motion, and distal torsion joints, respectively. This approach leverages existing knowledge about the system, demonstrating computational efficiency, intuitive comprehension, and independence from a training dataset, making it a versatile joint estimation technique. Experiments were conducted to compare the proposed method with currently employed joint estimation strategies. Additionally, real-time control was demonstrated using ultrasound feedback in a water bath, while subjecting the robotic transcatheter delivery system to similar tortuosity as encountered during a TMVr procedure.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (9) , 7677-7684
Ultrasound-Guided Real-Time Joint Space Control of a Robotic Transcatheter Delivery System
Transcatheter mitral valve repair (TMVr) is growing in popularity for non-surgical mitral regurgitation (MR) patients, but the manual operation of current TMVr devices increases radiation exposure and limits telesurgery feasibility. A robotically steerable delivery system can alleviate these problems, improving safety and precision while reducing staff fatigue. However, precise manipulation of a surgical robotic system requires system modeling and reliable external feedback. Ultrasound imaging provides visualization and guidance for precise instrument maneuvers within the body. Moreover, it is a readily available, safe, and cost-effective feedback modality, ideal for this procedure. Therefore, in this work, we use a previously derived model for the robotic transcatheter system and perform ultrasound-guided joint space control through real-time (algorithm run time: $\sim$ 0.011 s) estimation of four joints simultaneously. The joints are estimated using kinematically-derived weight maps, a new technique, and a feature detection algorithm, with an accuracy of 3.19$^\circ$, 2.76$^\circ$, 2.41 mm, and 6.83$^\circ$ for the proximal bending, distal bending, prismatic motion, and distal torsion joints, respectively. This approach leverages existing knowledge about the system, demonstrating computational efficiency, intuitive comprehension, and independence from a training dataset, making it a versatile joint estimation technique. Experiments were conducted to compare the proposed method with currently employed joint estimation strategies. Additionally, real-time control was demonstrated using ultrasound feedback in a water bath, while subjecting the robotic transcatheter delivery system to similar tortuosity as encountered during a TMVr procedure.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (9) , 7691-7698
Modeling Non-Linear Effects in a 4-DoF Robotic Transcatheter Delivery System
Transcatheter mitral valve repair (TMVr), a minimally invasive approach, is becoming increasingly popular for treating mitral regurgitation (MR) since nearly half of the MR patients are non-surgical candidates. However, current TMVr devices are operated manually, increasing radiation exposure to the clinical staff and making telesurgery infeasible. A robotically steerable transcatheter delivery system can alleviate these issues while also enhancing consistency, improving precision, and mitigating human fatigue during the procedure. Moreover, precise manipulation of a surgical robotic system requires effective system modeling. Therefore, in this work, we model a full-scale robotically steerable transcatheter delivery system, accounting for the hysteresis, friction, tendon elongation, and catheter configuration. We also account for the coupling between the joints of the robotic steerable end and the effect of the catheter configuration on the joints. Experiments were conducted in free air to validate the proposed model while subjecting the robotic transcatheter delivery system to similar tortuosity as encountered during a TMVr procedure.
- 10 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (9) , 7691-7698
Modeling Non-Linear Effects in a 4-DoF Robotic Transcatheter Delivery System
Transcatheter mitral valve repair (TMVr), a minimally invasive approach, is becoming increasingly popular for treating mitral regurgitation (MR) since nearly half of the MR patients are non-surgical candidates. However, current TMVr devices are operated manually, increasing radiation exposure to the clinical staff and making telesurgery infeasible. A robotically steerable transcatheter delivery system can alleviate these issues while also enhancing consistency, improving precision, and mitigating human fatigue during the procedure. Moreover, precise manipulation of a surgical robotic system requires effective system modeling. Therefore, in this work, we model a full-scale robotically steerable transcatheter delivery system, accounting for the hysteresis, friction, tendon elongation, and catheter configuration. We also account for the coupling between the joints of the robotic steerable end and the effect of the catheter configuration on the joints. Experiments were conducted in free air to validate the proposed model while subjecting the robotic transcatheter delivery system to similar tortuosity as encountered during a TMVr procedure.
- 30 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (4) , 867-878
Compact Design and Task Space Control of a Robotic Transcatheter Delivery System for Mitral Valve Implant
Mitral regurgitation (MR) is one of the most common valvular abnormalities, and the gold-standard for treatment is surgical mitral valve repair/replacement. Most patients with severe MR are over the age of 75, which makes open-heart surgery challenging. Thus, minimally invasive surgeries using transcatheter approaches are gaining popularity. This paper proposes the next generation of a robotic transcatheter delivery system for the mitral valve implant that focuses on the design of the actuation system, modeling, and task space control. The proposed actuation system is compact while still enabling bidirectional torsion, bending, and prismatic joint motion. A pulley structure is employed to actuate the torsion and bending joints using only one motor per joint in conjunction with an antagonistic passive spring to reduce tendon slack. The robotic transcatheter is also optimized to increase its stability and reduce bending deflection. An inverse kinematics model (with an optimization algorithm), singularity analysis method, and joint hysteresis and compensation model are developed and verified. Finally, a task space controller is also proposed. Experiments, including trajectory tracking and demonstrations of the robot motion in an ex vivo porcine heart and a phantom heart through a tortuous path are presented.
- 30 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (4) , 867-878
Compact Design and Task Space Control of a Robotic Transcatheter Delivery System for Mitral Valve Implant
Mitral regurgitation (MR) is one of the most common valvular abnormalities, and the gold-standard for treatment is surgical mitral valve repair/replacement. Most patients with severe MR are over the age of 75, which makes open-heart surgery challenging. Thus, minimally invasive surgeries using transcatheter approaches are gaining popularity. This paper proposes the next generation of a robotic transcatheter delivery system for the mitral valve implant that focuses on the design of the actuation system, modeling, and task space control. The proposed actuation system is compact while still enabling bidirectional torsion, bending, and prismatic joint motion. A pulley structure is employed to actuate the torsion and bending joints using only one motor per joint in conjunction with an antagonistic passive spring to reduce tendon slack. The robotic transcatheter is also optimized to increase its stability and reduce bending deflection. An inverse kinematics model (with an optimization algorithm), singularity analysis method, and joint hysteresis and compensation model are developed and verified. Finally, a task space controller is also proposed. Experiments, including trajectory tracking and demonstrations of the robot motion in an ex vivo porcine heart and a phantom heart through a tortuous path are presented.
- 7 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (6) , 3629-3636
Telerobotic Transcatheter Delivery System for Mitral Valve Implant
Mitral regurgitation (MR) is the most common type of valvular heart disease, affecting over 2% of the world population, and the gold-standard treatment is surgical mitral valve repair/replacement. Compared to open-heart surgeries, minimally invasive surgeries (MIS) using transcatheter approaches have become popular because of their notable benefits such as less postoperative pain, shorter hospital stay, and faster recovery time. However, commercially available catheters are manually actuated, causing over-exposure of clinical staff to radiation and increased risk of human error during medical interventions. To tackle this problem, in this letter, we propose a telerobotic transcatheter delivery system, which consists of a robotic catheter (5.7 mm OD), a reinforced guide tube (1.11 m length), and an actuation system. We present the robotic system design, fabrication of key components, and static model of reinforced quadlumen tube. The robot interface design enables the user to intuitively control the robot. We demonstrate the effectiveness of the telerobotic transcatheter delivery system and reinforced quadlumen tube in a realistic human cardiovascular phantom for preclinical evaluation.
- 7 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (6) , 3629-3636
Telerobotic Transcatheter Delivery System for Mitral Valve Implant
Mitral regurgitation (MR) is the most common type of valvular heart disease, affecting over 2% of the world population, and the gold-standard treatment is surgical mitral valve repair/replacement. Compared to open-heart surgeries, minimally invasive surgeries (MIS) using transcatheter approaches have become popular because of their notable benefits such as less postoperative pain, shorter hospital stay, and faster recovery time. However, commercially available catheters are manually actuated, causing over-exposure of clinical staff to radiation and increased risk of human error during medical interventions. To tackle this problem, in this letter, we propose a telerobotic transcatheter delivery system, which consists of a robotic catheter (5.7 mm OD), a reinforced guide tube (1.11 m length), and an actuation system. We present the robotic system design, fabrication of key components, and static model of reinforced quadlumen tube. The robot interface design enables the user to intuitively control the robot. We demonstrate the effectiveness of the telerobotic transcatheter delivery system and reinforced quadlumen tube in a realistic human cardiovascular phantom for preclinical evaluation.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (4) , 922-934
Toward the Design and Development of a Robotic Transcatheter Delivery System for Mitral Valve Implant
Minimally-invasive surgeries using transcatheter approaches and sophisticated imaging modalities are gaining popularity to treat mitral regurgitation (MR). This paper proposes the next generation of a robotic catheter to deliver an implant onto the mitral valve (MV) through a transseptal approach. The proposed robot has an outer diameter (OD) of 5.7 mm, a rigid distal end length of 20 mm, a prismatic tube that can be advanced by 50-60 mm, and a bending joint that can easily bend 120° to reach the valve opening. The implant can be rotated 75° bidirectionally by the distal torsion joint to orient it with the MV leaflet for precise implantation. The robotic joints are modeled individually, the forward and inverse kinematics are derived, and the robot motion validation is carried out through experimentation. A modified kinematics (MK) model, Prandtl-Ishlinskii (PI) hysteresis model, and hybrid of MK and PI model are used to compensate for the catheter nonlinearities. A preliminary study is conducted to evaluate if force sensing can be used to compensate for the effects of fluid flow. Also, the implantation procedure is demonstrated in a phantom heart.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (4) , 922-934
Toward the Design and Development of a Robotic Transcatheter Delivery System for Mitral Valve Implant
Minimally-invasive surgeries using transcatheter approaches and sophisticated imaging modalities are gaining popularity to treat mitral regurgitation (MR). This paper proposes the next generation of a robotic catheter to deliver an implant onto the mitral valve (MV) through a transseptal approach. The proposed robot has an outer diameter (OD) of 5.7 mm, a rigid distal end length of 20 mm, a prismatic tube that can be advanced by 50-60 mm, and a bending joint that can easily bend 120° to reach the valve opening. The implant can be rotated 75° bidirectionally by the distal torsion joint to orient it with the MV leaflet for precise implantation. The robotic joints are modeled individually, the forward and inverse kinematics are derived, and the robot motion validation is carried out through experimentation. A modified kinematics (MK) model, Prandtl-Ishlinskii (PI) hysteresis model, and hybrid of MK and PI model are used to compensate for the catheter nonlinearities. A preliminary study is conducted to evaluate if force sensing can be used to compensate for the effects of fluid flow. Also, the implantation procedure is demonstrated in a phantom heart.
- 22 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (4) , 928-935
Toward Real-Time Pose Estimation of the Mitral Valve Robot Under C-Arm X-Ray Fluoroscopy
Mitral regurgitation (MR) is a condition caused by a deformity in the mitral valve leading to the backflow of blood into the left atrium. MR can be treated through a minimally invasive procedure and our lab is currently developing a robot that could potentially be used to treat MR. The robot would carry a clip that latches onto the valve’s leaflets and closes them to minimize leakage. The robot’s accurate localization is needed to navigate the clip to the leaflets successfully. This paper discusses algorithms used to track the clip’s position and orientation under real-time using C-arm fluoroscopy. The positions are found through a deep learning semantic segmentation framework and the pose is found by calculating its bending and rotational angles. The robot’s bending angle and the clip’s rotational angle is found through an equivalent ellipse algorithm and an SVM classifier, respectively, and were validated by comparing orientations obtained from an electromagnetic tracker. The bending angle calculation has an average error of 7.7° and the rotational angle calculation is 76% for classifying them into five classes. Execution times are within 100ms and hence this could be a promising approach in real-time pose estimation.
- 22 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (4) , 928-935
Toward Real-Time Pose Estimation of the Mitral Valve Robot Under C-Arm X-Ray Fluoroscopy
Mitral regurgitation (MR) is a condition caused by a deformity in the mitral valve leading to the backflow of blood into the left atrium. MR can be treated through a minimally invasive procedure and our lab is currently developing a robot that could potentially be used to treat MR. The robot would carry a clip that latches onto the valve’s leaflets and closes them to minimize leakage. The robot’s accurate localization is needed to navigate the clip to the leaflets successfully. This paper discusses algorithms used to track the clip’s position and orientation under real-time using C-arm fluoroscopy. The positions are found through a deep learning semantic segmentation framework and the pose is found by calculating its bending and rotational angles. The robot’s bending angle and the clip’s rotational angle is found through an equivalent ellipse algorithm and an SVM classifier, respectively, and were validated by comparing orientations obtained from an electromagnetic tracker. The bending angle calculation has an average error of 7.7° and the rotational angle calculation is 76% for classifying them into five classes. Execution times are within 100ms and hence this could be a promising approach in real-time pose estimation.