Guntars Vaivars
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Guntars Vaivars has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Einars Sprugis
Institute of Chemical Physics, University of Latvia, Jelgavas Iela 1, LV-1004 Riga, Latvia
4 shared publications - Elina Pajuste
University of Latvia, Riga, Latvia
3 shared publications - Liga Avotina
University of Latvia
3 shared publications - Elizabete Maskova
Institute of Chemical Physics, University of Latvia, Jelgavas Iela 1, LV-1004 Riga, Latvia
2 shared publications - Gunars Bajars
Institute of Solid State Physics, University of Latvia
2 shared publications - Ingars Reinholds
Institute of Food Safety, Animal Health and Environment “BIOR”, Lejupes Iela 3, LV-1076 Riga, Latvia
2 shared publications
Latest Publications
- Open Access
Critical Evaluation of the Methods for the Characterization of the Degree of Sulfonation for Electron Beam Irradiated and Non-Irradiated Sulfonated Poly(ether ether ketone) Membranes
Sulfonated poly(ether ether ketone) (SPEEK) materials are promising candidates for replacing Nafion™ in applications such as proton exchange membrane (PEM) and direct methanol fuel cells. SPEEK membranes have several advantages such as low cost, thermal and radiation stability and controllable physicochemical and mechanical properties, which depend on the degree of sulfonation (DS). Commercial PEEK was homogenously sulfonated up to a DS of 60–90% and the membranes were prepared using a solvent casting method. Part of the samples were irradiated with a 10 MeV electron beam up to a 500 kGy dose to assess the ionizing radiation-induced effects. Both non-irradiated and irradiated membranes were characterized by Fourier Transformation infrared (FT-IR) spectroscopy, thermogravimetric analysis (TGA), proton nuclear magnetic resonance (1H-NMR) spectroscopy, electrochemical impedance analysis and, for the first time for non-irradiated membranes, by spectrophotometric analysis with Cr(III). The above-mentioned methods for application for DS assessment were compared. The aim of this study is to compare different methods used for the determination of the DS of SPEEK membranes before and after high-dose irradiation. It was observed that irradiated membranes presented a higher value of DS. The appearance of different new signals in 1H-NMR and FT-IR spectra of irradiated membranes indicated that the effects of radiation induced changes in the structure of SPEEK materials. The good correlation of Cr(III) absorption and SPEEK DS up to 80% indicates that the spectrophotometric method is a comparable tool for the characterization of SPEEK membranes.
Open AccessCritical Evaluation of the Methods for the Characterization of the Degree of Sulfonation for Electron Beam Irradiated and Non-Irradiated Sulfonated Poly(ether ether ketone) Membranes
Sulfonated poly(ether ether ketone) (SPEEK) materials are promising candidates for replacing Nafion™ in applications such as proton exchange membrane (PEM) and direct methanol fuel cells. SPEEK membranes have several advantages such as low cost, thermal and radiation stability and controllable physicochemical and mechanical properties, which depend on the degree of sulfonation (DS). Commercial PEEK was homogenously sulfonated up to a DS of 60–90% and the membranes were prepared using a solvent casting method. Part of the samples were irradiated with a 10 MeV electron beam up to a 500 kGy dose to assess the ionizing radiation-induced effects. Both non-irradiated and irradiated membranes were characterized by Fourier Transformation infrared (FT-IR) spectroscopy, thermogravimetric analysis (TGA), proton nuclear magnetic resonance (1H-NMR) spectroscopy, electrochemical impedance analysis and, for the first time for non-irradiated membranes, by spectrophotometric analysis with Cr(III). The above-mentioned methods for application for DS assessment were compared. The aim of this study is to compare different methods used for the determination of the DS of SPEEK membranes before and after high-dose irradiation. It was observed that irradiated membranes presented a higher value of DS. The appearance of different new signals in 1H-NMR and FT-IR spectra of irradiated membranes indicated that the effects of radiation induced changes in the structure of SPEEK materials. The good correlation of Cr(III) absorption and SPEEK DS up to 80% indicates that the spectrophotometric method is a comparable tool for the characterization of SPEEK membranes.
- Open Access
- 10 August 2023
- Published by MDPI AG in Preprints.org
Critical Evaluation of the Methods for the Characterisation of the Degree of Sulfonation for Electron Beam Irradiated and Non-Irradiated Sulfonated Poly(ether ether ketone) Membranes
The aim of this study is to compare different methods used for determination of the DS for sulfonated membranes before and after high dose irradiation. Commercial PEEK was homogenously sulfonated up to DS of 60-90% and the membranes were prepared using solvent casting method. Part of the samples were irradiated with 10 MeV electron beam up to 500 kGy dose to assess the ionising radiation induced effects. Both non-irradiated and irradiated membranes were characterized by Fourier Transformation infrared (FT-IR) spectrometry, thermogravimetric analysis (TGA), proton nuclear magnetic resonance (1H-NMR), electrochemical impedance analysis and for the first time for non-irradiated membranes by spectrophotometric analysis with Cr(III). Comparison of the above-mentioned methods for application for DS assessment was done. It was observed that irradiated membranes presented a higher value of DS. Appearance of different new signals in 1H-NMR and FT-IR spectra of irradiated membranes indicated the effects of radiation induced changes in the structure of SPEEK materials. It was determined that the novel method with Cr(III) is applicable for the determination of SPEEK DS under 80%.
- 10 August 2023
- Published by MDPI AG in Preprints.org
Open AccessCritical Evaluation of the Methods for the Characterisation of the Degree of Sulfonation for Electron Beam Irradiated and Non-Irradiated Sulfonated Poly(ether ether ketone) Membranes
The aim of this study is to compare different methods used for determination of the DS for sulfonated membranes before and after high dose irradiation. Commercial PEEK was homogenously sulfonated up to DS of 60-90% and the membranes were prepared using solvent casting method. Part of the samples were irradiated with 10 MeV electron beam up to 500 kGy dose to assess the ionising radiation induced effects. Both non-irradiated and irradiated membranes were characterized by Fourier Transformation infrared (FT-IR) spectrometry, thermogravimetric analysis (TGA), proton nuclear magnetic resonance (1H-NMR), electrochemical impedance analysis and for the first time for non-irradiated membranes by spectrophotometric analysis with Cr(III). Comparison of the above-mentioned methods for application for DS assessment was done. It was observed that irradiated membranes presented a higher value of DS. Appearance of different new signals in 1H-NMR and FT-IR spectra of irradiated membranes indicated the effects of radiation induced changes in the structure of SPEEK materials. It was determined that the novel method with Cr(III) is applicable for the determination of SPEEK DS under 80%.
- 10 February 2023
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 27 (7) , 1641-1660
From electrochromic phenomena to energy harvesting and storage—an overview of solid state ionics research at the Institute of Solid State Physics, University of Latvia
- 10 February 2023
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 27 (7) , 1641-1660
From electrochromic phenomena to energy harvesting and storage—an overview of solid state ionics research at the Institute of Solid State Physics, University of Latvia
- Open Access
- 29 June 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (13) , 2234
Impact of Helium Ion Implantation Dose and Annealing on Dense Near-Surface Layers of NV Centers
The implantation of diamonds with helium ions has become a common method to create hundreds-nanometers-thick near-surface layers of NV centers for high-sensitivity sensing and imaging applications; however, optimal implantation dose and annealing temperature are still a matter of discussion. In this study, we irradiated HPHT diamonds with an initial nitrogen concentration of 100 ppm using different implantation doses of helium ions to create 200-nm thick NV layers. We compare a previously considered optimal implantation dose of ∼ Hecm to double and triple doses by measuring fluorescence intensity, contrast, and linewidth of magnetic resonances, as well as longitudinal and transversal relaxation times and . From these direct measurements, we also estimate concentrations of P1 and NV centers. In addition, we compare the three diamond samples that underwent three consequent annealing steps to quantify the impact of processing at 1100 C, which follows initial annealing at 800 C. By tripling the implantation dose, we have increased the magnetic sensitivity of our sensors by %. By projecting our results to higher implantation doses, we demonstrate that it is possible to achieve a further improvement of up to 70%. At the same time, additional annealing steps at 1100 C improve the sensitivity only by 6.6 ± 2.7%.- 29 June 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (13) , 2234
Open AccessImpact of Helium Ion Implantation Dose and Annealing on Dense Near-Surface Layers of NV Centers
The implantation of diamonds with helium ions has become a common method to create hundreds-nanometers-thick near-surface layers of NV centers for high-sensitivity sensing and imaging applications; however, optimal implantation dose and annealing temperature are still a matter of discussion. In this study, we irradiated HPHT diamonds with an initial nitrogen concentration of 100 ppm using different implantation doses of helium ions to create 200-nm thick NV layers. We compare a previously considered optimal implantation dose of ∼ Hecm to double and triple doses by measuring fluorescence intensity, contrast, and linewidth of magnetic resonances, as well as longitudinal and transversal relaxation times and . From these direct measurements, we also estimate concentrations of P1 and NV centers. In addition, we compare the three diamond samples that underwent three consequent annealing steps to quantify the impact of processing at 1100 C, which follows initial annealing at 800 C. By tripling the implantation dose, we have increased the magnetic sensitivity of our sensors by %. By projecting our results to higher implantation doses, we demonstrate that it is possible to achieve a further improvement of up to 70%. At the same time, additional annealing steps at 1100 C improve the sensitivity only by 6.6 ± 2.7%. - Open Access
- 8 May 2022
- Published by Elsevier in Polymer Degradation and Stability
- Vol. 200
Evaluation of radiation stability of electron beam irradiated Nafion® and sulfonated poly(ether ether ketone) membranes
- 8 May 2022
- Published by Elsevier in Polymer Degradation and Stability
- Vol. 200
Open AccessEvaluation of radiation stability of electron beam irradiated Nafion® and sulfonated poly(ether ether ketone) membranes
- 20 November 2021
- Published by Kaunas University of Technology (KTU) in Materials Science
- Vol. 27 (4) , 466-469
A Study of Osmosis Rate Through Several Proton Conducting Polymer Composite Membranes
Carbon dioxide is typically considered to be a byproduct of various industrial processes that should not be released into the environment due to its nature as a harmful greenhouse gas. One of the more promising ways to dispose of it in an economical and environmentally friendly way is by using it as a raw material in electrochemical synthesis reactors. An important part of such reactors is an ion exchange membrane. In this study the influence of ZrO2 content in SPEEK – ZrO2 composite membranes on rate of osmosis trough them was investigated, with the goal of evaluating ZrO2 as an additive for making ion exchange membranes with fine-tuned osmotic permeability.
- 20 November 2021
- Published by Kaunas University of Technology (KTU) in Materials Science
- Vol. 27 (4) , 466-469
A Study of Osmosis Rate Through Several Proton Conducting Polymer Composite Membranes
Carbon dioxide is typically considered to be a byproduct of various industrial processes that should not be released into the environment due to its nature as a harmful greenhouse gas. One of the more promising ways to dispose of it in an economical and environmentally friendly way is by using it as a raw material in electrochemical synthesis reactors. An important part of such reactors is an ion exchange membrane. In this study the influence of ZrO2 content in SPEEK – ZrO2 composite membranes on rate of osmosis trough them was investigated, with the goal of evaluating ZrO2 as an additive for making ion exchange membranes with fine-tuned osmotic permeability.
- Open Access
- 1 June 2020
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 850, 138-143
Modelling IR Spectra of Sulfonated Polyether Ether Ketone (SPEEK) Membranes for Fuel Cells
SPEEK (sulfonated polyether ether ketone) membranes have been prepared and characterized. The SPEEK membrane geometry and theoretical vibration spectra calculated using density functional theory (DFT) as depending from membrane chain length and polymer cross-linking. Analyzed the limitations of the method by comparing theoretical and experimental IR spectra.
- 1 June 2020
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 850, 138-143
Open AccessModelling IR Spectra of Sulfonated Polyether Ether Ketone (SPEEK) Membranes for Fuel Cells
SPEEK (sulfonated polyether ether ketone) membranes have been prepared and characterized. The SPEEK membrane geometry and theoretical vibration spectra calculated using density functional theory (DFT) as depending from membrane chain length and polymer cross-linking. Analyzed the limitations of the method by comparing theoretical and experimental IR spectra.
- 1 May 1993
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 13 (1-3) , 269-271
Solid proton conductors as room-temperature gas sensors
- 1 May 1993
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 13 (1-3) , 269-271
Solid proton conductors as room-temperature gas sensors