Vincent Becker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vincent Becker has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jose Alfonso Antonino Daviu
Instituto Tecnológico de la Energía, Universitat Politècnica de València (UPV), Camino de Vera s/n, 46022 Valencia, Spain
2 shared publications - Sven Urschel
Working Group Electrotechnical Systems of Mechatronics, Kaiserslautern University of Applied Sciences, 67659 Kaiserslautern, Germany
2 shared publications - Angela Navarro-Navarro
Instituto Tecnológico de la Energía (ITE), Universitat Politècnica de València (UPV), Camino de Vera S/N, 46022 Valencia, Spain
1 shared publication - Jose Enrique Ruiz-Sarrio
Instituto Tecnológico de la Energía (ITE), Universitat Politècnica de València (UPV), 46022 Valencia, Spain
1 shared publication - Thilo Schwamm
University of Applied Sciences Kaiserslautern, Schoenstraße 11, 67659 Kaiserslautern, Germany
1 shared publication - Vicente Biot-Monterde
Instituto Tecnológico de la Energía (ITE), Universitat Politècnica de València (UPV), Camino de Vera S/N, 46022 Valencia, Spain
1 shared publication
Latest Publications
- Open Access
Application of Transient Analysis Techniques to Fault Diagnosis in Low- and Medium-Power Synchronous Machines
Fault diagnosis techniques applied to synchronous motors such as Permanent Magnet Synchronous Machines (PMSMs) and Synchronous Reluctance Machines (SynRMs) are scarcely addressed in the literature, in strong contrast to the attention paid to asynchronous motors. In addition, the most widespread techniques are those based on steady-state condition analysis, and little attention is paid to detection during transient operation. The present paper aims to identify research gaps on the topic and to demonstrate the potential of transient analysis. First, the different diagnostic methodologies in literature are thoroughly analyzed. Then, two laboratory case studies are presented to demonstrate the potential of fault detection under non-stationary conditions for a PMSM and a SynRM. Stator current analysis is performed by building time–frequency maps to analyze the evolution of different fault indicators. The results show clear differences between healthy and faulty conditions during the transient regime.
Open AccessApplication of Transient Analysis Techniques to Fault Diagnosis in Low- and Medium-Power Synchronous Machines
Fault diagnosis techniques applied to synchronous motors such as Permanent Magnet Synchronous Machines (PMSMs) and Synchronous Reluctance Machines (SynRMs) are scarcely addressed in the literature, in strong contrast to the attention paid to asynchronous motors. In addition, the most widespread techniques are those based on steady-state condition analysis, and little attention is paid to detection during transient operation. The present paper aims to identify research gaps on the topic and to demonstrate the potential of transient analysis. First, the different diagnostic methodologies in literature are thoroughly analyzed. Then, two laboratory case studies are presented to demonstrate the potential of fault detection under non-stationary conditions for a PMSM and a SynRM. Stator current analysis is performed by building time–frequency maps to analyze the evolution of different fault indicators. The results show clear differences between healthy and faulty conditions during the transient regime.
- Open Access
Two Current-Based Methods for the Detection of Bearing and Impeller Faults in Variable Speed Pumps
The growing number of variable speed drives (VSDs) in industry has an impact on the future development of condition monitoring methods. In research, more and more attention is being paid to condition monitoring based on motor current evaluation. However, there are currently only a few contributions to current-based pump diagnosis. In this paper, two current-based methods for the detection of bearing defects, impeller clogging, and cracked impellers are presented. The first approach, load point-dependent fault indicator analysis (LoPoFIA), is an approach that was derived from motor current signature analysis (MCSA). Compared to MCSA, the novelty of LoPoFIA is that only amplitudes at typical fault frequencies in the current spectrum are considered as a function of the hydraulic load point. The second approach is advanced transient current signature analysis (ATCSA), which represents a time-frequency analysis of a current signal during start-up. According to the literature, ATCSA is mainly used for motor diagnosis. As a test item, a VSD-driven circulation pump was measured in a pump test bench. Compared to MCSA, both LoPoFIA and ATCSA showed improvements in terms of minimizing false alarms. However, LoPoFIA simplifies the separation of bearing defects and impeller defects, as impeller defects especially influence higher flow ranges. Compared to LoPoFIA, ATCSA represents a more efficient method in terms of minimizing measurement effort. In summary, both LoPoFIA and ATCSA provide important insights into the behavior of faulty pumps and can be advantageous compared to MCSA in terms of false alarms and fault separation.
Open AccessTwo Current-Based Methods for the Detection of Bearing and Impeller Faults in Variable Speed Pumps
The growing number of variable speed drives (VSDs) in industry has an impact on the future development of condition monitoring methods. In research, more and more attention is being paid to condition monitoring based on motor current evaluation. However, there are currently only a few contributions to current-based pump diagnosis. In this paper, two current-based methods for the detection of bearing defects, impeller clogging, and cracked impellers are presented. The first approach, load point-dependent fault indicator analysis (LoPoFIA), is an approach that was derived from motor current signature analysis (MCSA). Compared to MCSA, the novelty of LoPoFIA is that only amplitudes at typical fault frequencies in the current spectrum are considered as a function of the hydraulic load point. The second approach is advanced transient current signature analysis (ATCSA), which represents a time-frequency analysis of a current signal during start-up. According to the literature, ATCSA is mainly used for motor diagnosis. As a test item, a VSD-driven circulation pump was measured in a pump test bench. Compared to MCSA, both LoPoFIA and ATCSA showed improvements in terms of minimizing false alarms. However, LoPoFIA simplifies the separation of bearing defects and impeller defects, as impeller defects especially influence higher flow ranges. Compared to LoPoFIA, ATCSA represents a more efficient method in terms of minimizing measurement effort. In summary, both LoPoFIA and ATCSA provide important insights into the behavior of faulty pumps and can be advantageous compared to MCSA in terms of false alarms and fault separation.