Hilde Kjernlie Andersen
Hilde Kjernlie Andersen has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Andrei Purysko
Abdominal Imaging Section, Diagnostics Institute, and Glickman Urological and Kidney Institute, Cleveland Clinic, Cleveland, OH 44195, USA
1 shared publication- Anne Catrine Trægde Martinsen
Department of Physics, University of Oslo, 0316 Oslo, Norway
1 shared publication - Anselm Schulz
Department of Radiology and Nuclear Medicine, Oslo University Hospital Ullevål, Oslo, Norway
1 shared publication - Antony W. Rix
Lucida Medical, Cambridge, CB4 2HY, United Kingdom
1 shared publication Baris Turkbey
Molecular Imaging Branch, National Cancer Institute, NIH, Bethesda, MD 20892, USA
1 shared publication- Bino Abel Varghese
Keck School of Medicine University of Southern California Los Angeles California USA
1 shared publication
Latest Publications
- Open Access
- 28 September 2026
- Published by Elsevier in Diagnostic and Interventional Imaging
Inter-reader variability for quality assessment of synthetically degraded prostate MR images aligned with PIQUAL version 2
- 28 September 2026
- Published by Elsevier in Diagnostic and Interventional Imaging
Open AccessInter-reader variability for quality assessment of synthetically degraded prostate MR images aligned with PIQUAL version 2
- Open Access
- 14 November 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (4) , e14192
Investigating the role of imaging factors in the variability of CT‐based texture analysis metrics
Objective: This study assesses the robustness of first‐order radiomic texture features namely interquartile range (IQR), coefficient of variation (CV) and standard deviation (SD) derived from computed tomography (CT) images by varying dose, reconstruction algorithms and slice thickness using scans of a uniform water phantom, a commercial anthropomorphic liver phantom, and a human liver in‐vivo.Materials and Methods: Scans were acquired on a 16 cm detector GE Revolution Apex Edition CT scanner with variations across three different nominal slice thicknesses: 0.625, 1.25, and 2.5 mm, three different dose levels: CTDIvol of 13.86 mGy for the standard dose, 40% reduced dose and 60% reduced dose and two different reconstruction algorithms: a deep learning image reconstruction (DLIR‐high) algorithm and a hybrid iterative reconstruction (IR) algorithm ASiR‐V50% (AV50) were explored, varying one at a time. To assess the effect of non‐linear modifications of images by AV50 and DLIR‐high, images of the water phantom were also reconstructed using filtered back projection (FBP). Quantitative measures of IQR, CV and SD were extracted from twelve pre‐selected, circular (1 cm diameter) regions of interest (ROIs) capturing different texture patterns across all scans.Results: Across all scans, imaging, and reconstruction settings, CV, IQR and SD were observed to increase with reduction in dose and slice thickness. An exception to this observation was found when using FBP reconstruction. Lower values of CV, IQR and SD were observed in DLIR‐high reconstructions compared to AV50 and FBP. The Poisson statistics were more stringently noted in FBP than DLIR‐high and AV50, due to the non‐linear nature of the latter two algorithms.Conclusion: Variation in image noise due to dose reduction algorithms, tube current, and slice thickness show a consistent trend across phantom and patient scans. Prospective evaluation across multiple centers, scanners and imaging protocols is needed for establishing quality assurance standards of radiomics.
- 14 November 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (4) , e14192
Open AccessInvestigating the role of imaging factors in the variability of CT‐based texture analysis metrics
Objective: This study assesses the robustness of first‐order radiomic texture features namely interquartile range (IQR), coefficient of variation (CV) and standard deviation (SD) derived from computed tomography (CT) images by varying dose, reconstruction algorithms and slice thickness using scans of a uniform water phantom, a commercial anthropomorphic liver phantom, and a human liver in‐vivo.Materials and Methods: Scans were acquired on a 16 cm detector GE Revolution Apex Edition CT scanner with variations across three different nominal slice thicknesses: 0.625, 1.25, and 2.5 mm, three different dose levels: CTDIvol of 13.86 mGy for the standard dose, 40% reduced dose and 60% reduced dose and two different reconstruction algorithms: a deep learning image reconstruction (DLIR‐high) algorithm and a hybrid iterative reconstruction (IR) algorithm ASiR‐V50% (AV50) were explored, varying one at a time. To assess the effect of non‐linear modifications of images by AV50 and DLIR‐high, images of the water phantom were also reconstructed using filtered back projection (FBP). Quantitative measures of IQR, CV and SD were extracted from twelve pre‐selected, circular (1 cm diameter) regions of interest (ROIs) capturing different texture patterns across all scans.Results: Across all scans, imaging, and reconstruction settings, CV, IQR and SD were observed to increase with reduction in dose and slice thickness. An exception to this observation was found when using FBP reconstruction. Lower values of CV, IQR and SD were observed in DLIR‐high reconstructions compared to AV50 and FBP. The Poisson statistics were more stringently noted in FBP than DLIR‐high and AV50, due to the non‐linear nature of the latter two algorithms.Conclusion: Variation in image noise due to dose reduction algorithms, tube current, and slice thickness show a consistent trend across phantom and patient scans. Prospective evaluation across multiple centers, scanners and imaging protocols is needed for establishing quality assurance standards of radiomics.
- Open Access
- 15 July 2021
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-19
Three-stage segmentation of lung region from CT images using deep neural networks
Background: Lung region segmentation is an important stage of automated image-based approaches for the diagnosis of respiratory diseases. Manual methods executed by experts are considered the gold standard, but it is time consuming and the accuracy is dependent on radiologists’ experience. Automated methods are relatively fast and reproducible with potential to facilitate physician interpretation of images. However, these benefits are possible only after overcoming several challenges. The traditional methods that are formulated as a three-stage segmentation demonstrate promising results on normal CT data but perform poorly in the presence of pathological features and variations in image quality attributes. The implementation of deep learning methods that can demonstrate superior performance over traditional methods is dependent on the quantity, quality, cost and the time it takes to generate training data. Thus, efficient and clinically relevant automated segmentation method is desired for the diagnosis of respiratory diseases. Methods: We implement each of the three stages of traditional methods using deep learning methods trained on five different configurations of training data with ground truths obtained from the 3D Image Reconstruction for Comparison of Algorithm Database (3DIRCAD) and the Interstitial Lung Diseases (ILD) database. The data was augmented with the Lung Image Database Consortium (LIDC-IDRI) image collection and a realistic phantom. A convolutional neural network (CNN) at the preprocessing stage classifies the input into lung and none lung regions. The processing stage was implemented using a CNN-based U-net while the postprocessing stage utilize another U-net and CNN for contour refinement and filtering out false positives, respectively. Results: The performance of the proposed method was evaluated on 1230 and 1100 CT slices from the 3DIRCAD and ILD databases. We investigate the performance of the proposed method on five configurations of training data and three configurations of the segmentation system; three-stage segmentation and three-stage segmentation without a CNN classifier and contrast enhancement, respectively. The Dice-score recorded by the proposed method range from 0.76 to 0.95. Conclusion: The clinical relevance and segmentation accuracy of deep learning models can improve though deep learning-based three-stage segmentation, image quality evaluation and enhancement as well as augmenting the training data with large volume of cheap and quality training data. We propose a new and novel deep learning-based method of contour refinement.
- 15 July 2021
- Published by Springer Nature in BMC Medical Imaging
- Vol. 21 (1) , 1-19
Open AccessThree-stage segmentation of lung region from CT images using deep neural networks
Background: Lung region segmentation is an important stage of automated image-based approaches for the diagnosis of respiratory diseases. Manual methods executed by experts are considered the gold standard, but it is time consuming and the accuracy is dependent on radiologists’ experience. Automated methods are relatively fast and reproducible with potential to facilitate physician interpretation of images. However, these benefits are possible only after overcoming several challenges. The traditional methods that are formulated as a three-stage segmentation demonstrate promising results on normal CT data but perform poorly in the presence of pathological features and variations in image quality attributes. The implementation of deep learning methods that can demonstrate superior performance over traditional methods is dependent on the quantity, quality, cost and the time it takes to generate training data. Thus, efficient and clinically relevant automated segmentation method is desired for the diagnosis of respiratory diseases. Methods: We implement each of the three stages of traditional methods using deep learning methods trained on five different configurations of training data with ground truths obtained from the 3D Image Reconstruction for Comparison of Algorithm Database (3DIRCAD) and the Interstitial Lung Diseases (ILD) database. The data was augmented with the Lung Image Database Consortium (LIDC-IDRI) image collection and a realistic phantom. A convolutional neural network (CNN) at the preprocessing stage classifies the input into lung and none lung regions. The processing stage was implemented using a CNN-based U-net while the postprocessing stage utilize another U-net and CNN for contour refinement and filtering out false positives, respectively. Results: The performance of the proposed method was evaluated on 1230 and 1100 CT slices from the 3DIRCAD and ILD databases. We investigate the performance of the proposed method on five configurations of training data and three configurations of the segmentation system; three-stage segmentation and three-stage segmentation without a CNN classifier and contrast enhancement, respectively. The Dice-score recorded by the proposed method range from 0.76 to 0.95. Conclusion: The clinical relevance and segmentation accuracy of deep learning models can improve though deep learning-based three-stage segmentation, image quality evaluation and enhancement as well as augmenting the training data with large volume of cheap and quality training data. We propose a new and novel deep learning-based method of contour refinement.