Marek Furmanik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marek Furmanik has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Daniel Konvicny
1 shared publication- Daniel Konvicny
Department of Power Systems and Electric Drives, University of Zilina, 010 01 Zilina, Slovakia
1 shared publication Daniel Konvičný
1 shared publication- Lukas Gorel
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Zilina, Univerzitna 1, 010 26 Zilina, Slovakia
1 shared publication Lukáš Gorel
1 shared publicationMartin Sumega
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Zilina, Žilina, Slovakia
1 shared publication
Latest Publications
- Open Access
- 13 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (2) , 1077
Self-Sensing Six-Phase PMSM Drive Based on Back-EMF Measurement
This paper presents a novel procedure for the emergency sensorless operation of a six-phase electric drive. More degrees of freedom provided by multiphase technology have been utilized to determine the rotor flux position. The proposed technique is based on the direct measurement of the back EMF generated on a disconnected three-phase winding of a six-phase permanent-magnet synchronous machine (PMSM). The method is suitable for the emergency operation of an electric drive in the case of speed/position sensor failure. The proposed solution has been verified utilizing a six-phase permanent-magnet synchronous machine with a displacement of 30° between two three-phase sets of the stator winding and a power of 1 kW.
- 13 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (2) , 1077
Open AccessSelf-Sensing Six-Phase PMSM Drive Based on Back-EMF Measurement
This paper presents a novel procedure for the emergency sensorless operation of a six-phase electric drive. More degrees of freedom provided by multiphase technology have been utilized to determine the rotor flux position. The proposed technique is based on the direct measurement of the back EMF generated on a disconnected three-phase winding of a six-phase permanent-magnet synchronous machine (PMSM). The method is suitable for the emergency operation of an electric drive in the case of speed/position sensor failure. The proposed solution has been verified utilizing a six-phase permanent-magnet synchronous machine with a displacement of 30° between two three-phase sets of the stator winding and a power of 1 kW.
- Open Access
- 25 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 7841
Comparative Study and Overview of Field-Oriented Control Techniques for Six-Phase PMSMs
This paper targets the main current trend in automotive motor control applications, i.e., six-phase permanent−magnet synchronous machines. Multiphase machines have been studied for more than one decade, but they are currently becoming more and more important for automotive technology. Increased safety and improved reliability are the two main reasons why six-phase machines conquer safety-critical motor control applications. The paper provides a detailed description, analysis, and comparison of two field-oriented control strategies for six-phase machines. The article consists of four main parts: (1) a general introduction of the application field of six-phase machines; (2) a description of two different field-oriented control techniques; (3) a presentation of the experimental results, e.g., frequency and step response analysis, as well as a comparison between a mathematical model and a real system; (4) a detailed comparison of strategies including pros and cons, with a strong focus on the main advantages.
- 25 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 7841
Open AccessComparative Study and Overview of Field-Oriented Control Techniques for Six-Phase PMSMs
This paper targets the main current trend in automotive motor control applications, i.e., six-phase permanent−magnet synchronous machines. Multiphase machines have been studied for more than one decade, but they are currently becoming more and more important for automotive technology. Increased safety and improved reliability are the two main reasons why six-phase machines conquer safety-critical motor control applications. The paper provides a detailed description, analysis, and comparison of two field-oriented control strategies for six-phase machines. The article consists of four main parts: (1) a general introduction of the application field of six-phase machines; (2) a description of two different field-oriented control techniques; (3) a presentation of the experimental results, e.g., frequency and step response analysis, as well as a comparison between a mathematical model and a real system; (4) a detailed comparison of strategies including pros and cons, with a strong focus on the main advantages.
- Open Access
- 2 August 2021
- Published by MDPI AG in Preprints.org
Comparative Study and Overview of Field-oriented Control Techniques for 6-phase PMSM
The paper interprets a comparison of two mostly used techniques of a field-oriented control for 6-phase electric drives, with their pros and cons, as well as their differences in construction and behaviour. Both of these approaches have been realized. Frequency and step responses analysis have been demonstrated with a 6-phase permanent magnet synchronous machine. Experimental results have been compared with simulations based on a mathematical model.
- 2 August 2021
- Published by MDPI AG in Preprints.org
Open AccessComparative Study and Overview of Field-oriented Control Techniques for 6-phase PMSM
The paper interprets a comparison of two mostly used techniques of a field-oriented control for 6-phase electric drives, with their pros and cons, as well as their differences in construction and behaviour. Both of these approaches have been realized. Frequency and step responses analysis have been demonstrated with a 6-phase permanent magnet synchronous machine. Experimental results have been compared with simulations based on a mathematical model.
- Open Access
- 1 January 2021
- Published by Elsevier in Transportation Research Procedia
- Vol. 55, 935-940
Effect of increasing the sampling frequency with respect to the bandwidth of the PI controller of current control loop
- 1 January 2021
- Published by Elsevier in Transportation Research Procedia
- Vol. 55, 935-940
Open AccessEffect of increasing the sampling frequency with respect to the bandwidth of the PI controller of current control loop
- 18 March 2020
- Published by Springer Nature in Electrical Engineering
- Vol. 102 (1) , 157-165
Influence of power traces arrangement on quality and reliability of the DC-link current sensing
- 18 March 2020
- Published by Springer Nature in Electrical Engineering
- Vol. 102 (1) , 157-165
Influence of power traces arrangement on quality and reliability of the DC-link current sensing