Lukas Gorel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lukas Gorel has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Konvicny
Department of Power Systems and Electric Drives, University of Zilina, 010 01 Zilina, Slovakia
1 shared publication - Marek Furmanik
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Zilina, Univerzitna, 010 26 Zilina, Slovakia
1 shared publication - Michal Stano
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Žilina, 010 26 Žilina, Slovakia
1 shared publication - Michal Vidlak
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Zilina, Univerzitna 1, 010 26 Zilina, Slovakia
1 shared publication - Pavol Makys
Department of Power Electrical Systems, Faculty of Electrical Engineering and Information Technology, University of Žilina, Univerzitná 8215/1, 010 26 Žilina, Slovakia
1 shared publication - Pavol Rafajdus
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Žilina, 010 26 Žilina, Slovakia
1 shared publication
Latest Publications
- Open Access
Sensorless Speed Control of Brushed DC Motor Based at New Current Ripple Component Signal Processing
Signal processing of the brushed DC motor current was developed in this paper to obtain information about a rotor speed from a measured motor current. The brushed DC motor current contains a signal with a frequency proportional to the rotor speed. This signal is the outcome of a commutation process occurring in the brushed DC motor, and it is called a ripple component. Since the number of ripples in the measured motor current per one rotation is constant, the rotor speed can be estimated. A discrete bandpass filter with a floating bandwidth was developed as the main part of signal processing. This new interpretation of the bandpass filter was used to extract a frequency of the ripple component from the measured motor current. This frequency was used to acquire information about the estimated rotor speed. The estimated speed was set as a feedback value to a cascade control structure to provide sensorless speed control. The advantages and limitations of this approach are presented in this paper. Based on simulations and experimental results, it was confirmed that the proposed sensorless speed control is robust, accurate, and works precisely in a wide range of speeds.
Open AccessSensorless Speed Control of Brushed DC Motor Based at New Current Ripple Component Signal Processing
Signal processing of the brushed DC motor current was developed in this paper to obtain information about a rotor speed from a measured motor current. The brushed DC motor current contains a signal with a frequency proportional to the rotor speed. This signal is the outcome of a commutation process occurring in the brushed DC motor, and it is called a ripple component. Since the number of ripples in the measured motor current per one rotation is constant, the rotor speed can be estimated. A discrete bandpass filter with a floating bandwidth was developed as the main part of signal processing. This new interpretation of the bandpass filter was used to extract a frequency of the ripple component from the measured motor current. This frequency was used to acquire information about the estimated rotor speed. The estimated speed was set as a feedback value to a cascade control structure to provide sensorless speed control. The advantages and limitations of this approach are presented in this paper. Based on simulations and experimental results, it was confirmed that the proposed sensorless speed control is robust, accurate, and works precisely in a wide range of speeds.
- Open Access
- 25 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 7841
Comparative Study and Overview of Field-Oriented Control Techniques for Six-Phase PMSMs
This paper targets the main current trend in automotive motor control applications, i.e., six-phase permanent−magnet synchronous machines. Multiphase machines have been studied for more than one decade, but they are currently becoming more and more important for automotive technology. Increased safety and improved reliability are the two main reasons why six-phase machines conquer safety-critical motor control applications. The paper provides a detailed description, analysis, and comparison of two field-oriented control strategies for six-phase machines. The article consists of four main parts: (1) a general introduction of the application field of six-phase machines; (2) a description of two different field-oriented control techniques; (3) a presentation of the experimental results, e.g., frequency and step response analysis, as well as a comparison between a mathematical model and a real system; (4) a detailed comparison of strategies including pros and cons, with a strong focus on the main advantages.
- 25 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (17) , 7841
Open AccessComparative Study and Overview of Field-Oriented Control Techniques for Six-Phase PMSMs
This paper targets the main current trend in automotive motor control applications, i.e., six-phase permanent−magnet synchronous machines. Multiphase machines have been studied for more than one decade, but they are currently becoming more and more important for automotive technology. Increased safety and improved reliability are the two main reasons why six-phase machines conquer safety-critical motor control applications. The paper provides a detailed description, analysis, and comparison of two field-oriented control strategies for six-phase machines. The article consists of four main parts: (1) a general introduction of the application field of six-phase machines; (2) a description of two different field-oriented control techniques; (3) a presentation of the experimental results, e.g., frequency and step response analysis, as well as a comparison between a mathematical model and a real system; (4) a detailed comparison of strategies including pros and cons, with a strong focus on the main advantages.