Robin Volkmar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Robin Volkmar has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Keith Soal
German Aerospace Center DLR
2 shared publications - Marcus Baum
University of Goettingen
2 shared publications A. Bekker
1 shared publication- C. van Zijl1 shared publication
- Jose Gonzalez
Global Research, Ottobock SE & Co. KGaA , Duderstadt D-37115, Germany
1 shared publication M. Böswald
1 shared publication
Latest Publications
- Open Access
- 18 March 2026
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 250
Robust online monitoring of aircraft modal parameters using data fusion-based mode tracking
- 18 March 2026
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 250
Open AccessRobust online monitoring of aircraft modal parameters using data fusion-based mode tracking
- 1 September 2021
- Published by Elsevier in Marine Structures
- Vol. 79
The use of operational modal analysis and mode tracking for insight into polar vessel operations
- 1 September 2021
- Published by Elsevier in Marine Structures
- Vol. 79
The use of operational modal analysis and mode tracking for insight into polar vessel operations
- Open Access
- 14 November 2019
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 16 (1) , 1-13
Improving bimanual interaction with a prosthesis using semi-autonomous control
Background: The loss of a hand is a traumatic experience that substantially compromises an individual’s capability to interact with his environment. The myoelectric prostheses are state-of-the-art (SoA) functional replacements for the lost limbs. Their overall mechanical design and dexterity have improved over the last few decades, but the users have not been able to fully exploit these advances because of the lack of effective and intuitive control. Bimanual tasks are particularly challenging for an amputee since prosthesis control needs to be coordinated with the movement of the sound limb. So far, the bimanual activities have been often neglected by the prosthetic research community. Methods: We present a novel method to prosthesis control, which uses a semi-autonomous approach in order to simplify bimanual interactions. The approach supplements the commercial SoA two-channel myoelectric control with two additional sensors. Two inertial measurement units were attached to the prosthesis and the sound hand to detect the movement of both limbs. Once a bimanual interaction is detected, the system mimics the coordination strategies of able-bodied subjects to automatically adjust the prosthesis wrist rotation (pronation, supination) and grip type (lateral, palmar) to assist the sound hand during a bimanual task. The system has been evaluated in eight able-bodied subjects performing functional uni- and bi-manual tasks using the novel method and SoA two-channel myocontrol. The outcome measures were time to accomplish the task, semi-autonomous system misclassification rate, subjective rating of intuitiveness, and perceived workload (NASA TLX). Results: The results demonstrated that the novel control interface substantially outperformed the SoA myoelectric control. While using the semi-autonomous control the time to accomplish the task and the perceived workload decreased for 25 and 27%, respectively, while the subjects rated the system as more intuitive then SoA myocontrol. Conclusions: The novel system uses minimal additional hardware (two inertial sensors) and simple processing and it is therefore convenient for practical implementation. By using the proposed control scheme, the prosthesis assists the user’s sound hand in performing bimanual interactions while decreasing cognitive burden.
- 14 November 2019
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 16 (1) , 1-13
Open AccessImproving bimanual interaction with a prosthesis using semi-autonomous control
Background: The loss of a hand is a traumatic experience that substantially compromises an individual’s capability to interact with his environment. The myoelectric prostheses are state-of-the-art (SoA) functional replacements for the lost limbs. Their overall mechanical design and dexterity have improved over the last few decades, but the users have not been able to fully exploit these advances because of the lack of effective and intuitive control. Bimanual tasks are particularly challenging for an amputee since prosthesis control needs to be coordinated with the movement of the sound limb. So far, the bimanual activities have been often neglected by the prosthetic research community. Methods: We present a novel method to prosthesis control, which uses a semi-autonomous approach in order to simplify bimanual interactions. The approach supplements the commercial SoA two-channel myoelectric control with two additional sensors. Two inertial measurement units were attached to the prosthesis and the sound hand to detect the movement of both limbs. Once a bimanual interaction is detected, the system mimics the coordination strategies of able-bodied subjects to automatically adjust the prosthesis wrist rotation (pronation, supination) and grip type (lateral, palmar) to assist the sound hand during a bimanual task. The system has been evaluated in eight able-bodied subjects performing functional uni- and bi-manual tasks using the novel method and SoA two-channel myocontrol. The outcome measures were time to accomplish the task, semi-autonomous system misclassification rate, subjective rating of intuitiveness, and perceived workload (NASA TLX). Results: The results demonstrated that the novel control interface substantially outperformed the SoA myoelectric control. While using the semi-autonomous control the time to accomplish the task and the perceived workload decreased for 25 and 27%, respectively, while the subjects rated the system as more intuitive then SoA myocontrol. Conclusions: The novel system uses minimal additional hardware (two inertial sensors) and simple processing and it is therefore convenient for practical implementation. By using the proposed control scheme, the prosthesis assists the user’s sound hand in performing bimanual interactions while decreasing cognitive burden.