Fukiko Hihara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fukiko Hihara has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Chika Igarashi
Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba 263-8555, Japan
7 shared publications - Tatsuya Higashi
Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology
7 shared publications - Tomoko Tachibana
Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba 263-8555, Japan
7 shared publications - Yukie Yoshii
Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba 263-8555, Japan
7 shared publications - Hiroki Matsumoto
Institute for Quantum Medical Science, National Institutes for Quantum Science and Technology, Chiba 263-8555, Japan
6 shared publications - Hiroaki Kurihara
Department of Diagnostic Radiology, Kanagawa Cancer Center, Kanagawa 241-8515, Japan
5 shared publications
Latest Publications
- Open Access
- 22 September 2023
- Published by MDPI AG in Pharmaceuticals
- Vol. 16 (10) , 1341
Process to Remove the Size Variants Contained in the Antibody–Chelator Complex PCTA-NCAB001 for Radiolabeling with Copper-64
Understanding the physicochemical properties of antibody–drug conjugates is critical to assess their quality at manufacturing and monitor them during subsequent storage. For radiometal–antibody complexes, it is important to control the properties of the antibody–chelator conjugate to maintain the quality of the final product. We have been developing 64Cu-labeled anti-epidermal growth factor receptor antibody NCAB001 (64Cu-NCAB001) for the early diagnosis and therapy of pancreatic cancer with positron-emission tomography. Here, we characterized the larger size variants contained in the antibody–chelator conjugate PCTA-NCAB001 by multi-angle light scattering coupled with size-exclusion chromatography. Secondly, we developed a chromatographic method to remove these size variants. Lastly, we demonstrated the stability of PCTA-NCAB001 after the removal of size variants. Dimer and oligomers were identified in PCTA-NCAB001. These larger size variants, together with some smaller size variants, could be removed by hydrophobic interaction chromatography. The PCTA-NCAB001 product, after the removal of these size variants, could be stored at 4 °C for six months. The methods developed here can be applied to assure the quality of PCTA-NCAB001 and other antibody–drug conjugates to facilitate the development of antibody–radiometal conjugates for positron-emission tomography and radioimmunotherapy of malignant cancers.
- 22 September 2023
- Published by MDPI AG in Pharmaceuticals
- Vol. 16 (10) , 1341
Open AccessProcess to Remove the Size Variants Contained in the Antibody–Chelator Complex PCTA-NCAB001 for Radiolabeling with Copper-64
Understanding the physicochemical properties of antibody–drug conjugates is critical to assess their quality at manufacturing and monitor them during subsequent storage. For radiometal–antibody complexes, it is important to control the properties of the antibody–chelator conjugate to maintain the quality of the final product. We have been developing 64Cu-labeled anti-epidermal growth factor receptor antibody NCAB001 (64Cu-NCAB001) for the early diagnosis and therapy of pancreatic cancer with positron-emission tomography. Here, we characterized the larger size variants contained in the antibody–chelator conjugate PCTA-NCAB001 by multi-angle light scattering coupled with size-exclusion chromatography. Secondly, we developed a chromatographic method to remove these size variants. Lastly, we demonstrated the stability of PCTA-NCAB001 after the removal of size variants. Dimer and oligomers were identified in PCTA-NCAB001. These larger size variants, together with some smaller size variants, could be removed by hydrophobic interaction chromatography. The PCTA-NCAB001 product, after the removal of these size variants, could be stored at 4 °C for six months. The methods developed here can be applied to assure the quality of PCTA-NCAB001 and other antibody–drug conjugates to facilitate the development of antibody–radiometal conjugates for positron-emission tomography and radioimmunotherapy of malignant cancers.
- Open Access
- 12 September 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (9) , 1928
Preclinical Safety Evaluation of Intraperitoneally Administered Cu-Conjugated Anti-EGFR Antibody NCAB001 for the Early Diagnosis of Pancreatic Cancer Using PET
Detecting tumor lesions 64Cu-labeled anti-epidermal growth factor receptor (EGFR) antibody (64Cu-NCAB001 ipPET). Here, we conducted an extended single-dose toxicity study of 64Cu-NCAB001 ipPET in mice based on approach 1 of the current ICH M3 [R2] guideline, as our new drug formulation contains 45 μg of the antibody. We used NCAB001 labeled with stable copper isotope instead of 64Cu. The total content of size variants was approximately 6.0% throughout the study. The relative binding potency of Cu-NCAB001 to recombinant human EGFR was comparable to that of cetuximab. The general and neurological toxicities of Cu-NCAB001 ipPET at 62.5 or 625 μg/kg were assessed in mice. The no-observed-adverse-effect level of Cu-NCAB001 was 625 μg/kg, a dose approximately 1000-fold higher at the μg/kg level than the dose of 64Cu-NCAB001 in our formulation (45 µg). The size variants did not affect the safety of the formulation. Therefore, clinical studies on the efficacy of 64Cu-NCAB001 ipPET for early detection of pancreatic cancer using PET imaging can be safely conducted.
- 12 September 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (9) , 1928
Open AccessPreclinical Safety Evaluation of Intraperitoneally Administered Cu-Conjugated Anti-EGFR Antibody NCAB001 for the Early Diagnosis of Pancreatic Cancer Using PET
Detecting tumor lesions 64Cu-labeled anti-epidermal growth factor receptor (EGFR) antibody (64Cu-NCAB001 ipPET). Here, we conducted an extended single-dose toxicity study of 64Cu-NCAB001 ipPET in mice based on approach 1 of the current ICH M3 [R2] guideline, as our new drug formulation contains 45 μg of the antibody. We used NCAB001 labeled with stable copper isotope instead of 64Cu. The total content of size variants was approximately 6.0% throughout the study. The relative binding potency of Cu-NCAB001 to recombinant human EGFR was comparable to that of cetuximab. The general and neurological toxicities of Cu-NCAB001 ipPET at 62.5 or 625 μg/kg were assessed in mice. The no-observed-adverse-effect level of Cu-NCAB001 was 625 μg/kg, a dose approximately 1000-fold higher at the μg/kg level than the dose of 64Cu-NCAB001 in our formulation (45 µg). The size variants did not affect the safety of the formulation. Therefore, clinical studies on the efficacy of 64Cu-NCAB001 ipPET for early detection of pancreatic cancer using PET imaging can be safely conducted.
- Open Access
- 22 May 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (10) , 5807
In Vitro Tumor Cell-Binding Assay to Select High-Binding Antibody and Predict Therapy Response for Personalized 64Cu-Intraperitoneal Radioimmunotherapy against Peritoneal Dissemination of Pancreatic Cancer: A Feasibility Study
Peritoneal dissemination of pancreatic cancer has a poor prognosis. We have reported that intraperitoneal radioimmunotherapy using a 64Cu-labeled antibody (64Cu-ipRIT) is a promising adjuvant therapy option to prevent this complication. To achieve personalized 64Cu-ipRIT, we developed a new in vitro tumor cell-binding assay (64Cu-TuBA) system with a panel containing nine candidate 64Cu-labeled antibodies targeting seven antigens (EGFR, HER2, HER3, TfR, EpCAM, LAT1, and CD98), which are reportedly overexpressed in patients with pancreatic cancer. We investigated the feasibility of 64Cu-TuBA to select the highest-binding antibody for individual cancer cell lines and predict the treatment response in vivo for 64Cu-ipRIT. 64Cu-TuBA was performed using six human pancreatic cancer cell lines. For three cell lines, an in vivo treatment study was performed with 64Cu-ipRIT using high-, middle-, or low-binding antibodies in each peritoneal dissemination mouse model. The high-binding antibodies significantly prolonged survival in each mouse model, while low-and middle-binding antibodies were ineffective. There was a correlation between in vitro cell binding and in vivo therapeutic efficacy. Our findings suggest that 64Cu-TuBA can be used for patient selection to enable personalized 64Cu-ipRIT. Tumor cells isolated from surgically resected tumor tissues would be suitable for analysis with the 64Cu-TuBA system in future clinical studies.
- 22 May 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (10) , 5807
Open AccessIn Vitro Tumor Cell-Binding Assay to Select High-Binding Antibody and Predict Therapy Response for Personalized 64Cu-Intraperitoneal Radioimmunotherapy against Peritoneal Dissemination of Pancreatic Cancer: A Feasibility Study
Peritoneal dissemination of pancreatic cancer has a poor prognosis. We have reported that intraperitoneal radioimmunotherapy using a 64Cu-labeled antibody (64Cu-ipRIT) is a promising adjuvant therapy option to prevent this complication. To achieve personalized 64Cu-ipRIT, we developed a new in vitro tumor cell-binding assay (64Cu-TuBA) system with a panel containing nine candidate 64Cu-labeled antibodies targeting seven antigens (EGFR, HER2, HER3, TfR, EpCAM, LAT1, and CD98), which are reportedly overexpressed in patients with pancreatic cancer. We investigated the feasibility of 64Cu-TuBA to select the highest-binding antibody for individual cancer cell lines and predict the treatment response in vivo for 64Cu-ipRIT. 64Cu-TuBA was performed using six human pancreatic cancer cell lines. For three cell lines, an in vivo treatment study was performed with 64Cu-ipRIT using high-, middle-, or low-binding antibodies in each peritoneal dissemination mouse model. The high-binding antibodies significantly prolonged survival in each mouse model, while low-and middle-binding antibodies were ineffective. There was a correlation between in vitro cell binding and in vivo therapeutic efficacy. Our findings suggest that 64Cu-TuBA can be used for patient selection to enable personalized 64Cu-ipRIT. Tumor cells isolated from surgically resected tumor tissues would be suitable for analysis with the 64Cu-TuBA system in future clinical studies.
- Open Access
- 28 December 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (1) , 67
Characterization and Stabilization of a New 64Cu-Labeled Anti-EGFR Antibody NCAB001 for the Early Detection of Pancreatic Cancer with Positron Emission Tomography
Early diagnosis of pancreatic cancer using current imaging modalities remains challenging. We have developed a new approach to identify tumor lesions ≥ 3 mm in the pancreas by positron emission tomography (PET) with a new intraperitoneally administered 64Cu-labeled anti-epidermal growth factor receptor (EGFR) antibody (encoded as NCAB001), called 64Cu-NCAB001 ipPET. Generally, in clinical research, a radiometal-antibody complex must be prepared immediately before use at the imaging site. To make 64Cu-NCAB001 ipPET available to daily clinical practices in a sustainable way, the NCAB001-chelator conjugate and 64Cu-NCAB001 must be characterized and stabilized. NCAB001 was manufactured under cGMP conditions. NCAB001 was conjugated with a bifunctional chelator (p-SCN-Bn-PCTA), and the antibody-chelator conjugate (PCTA-NCAB001) was characterized by LC/MS and ELISA. Thereafter, to effectively manufacture 64Cu-NCAB001, we developed a new formulation to stabilize PCTA-NCAB001 and 64Cu-NCAB001. An average of three PCTA chelators were conjugated per molecule of NCAB001. The relative binding potency of PCTA-NCAB001 was comparable to cetuximab. The formulation consisting of acetate buffer, glycine, and polysorbate-80 stabilized PCTA-NCAB001 for a year-long storage. Additionally, this formulation enabled the stabilization of 64Cu-NCAB001 for up to 24 h after radiolabeling with a sufficient radioactivity concentration for clinical use. These results may accelerate the future use of 64Cu-NCAB001 ipPET in clinical settings for the early diagnosis and treatment of pancreatic cancer.
- 28 December 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (1) , 67
Open AccessCharacterization and Stabilization of a New 64Cu-Labeled Anti-EGFR Antibody NCAB001 for the Early Detection of Pancreatic Cancer with Positron Emission Tomography
Early diagnosis of pancreatic cancer using current imaging modalities remains challenging. We have developed a new approach to identify tumor lesions ≥ 3 mm in the pancreas by positron emission tomography (PET) with a new intraperitoneally administered 64Cu-labeled anti-epidermal growth factor receptor (EGFR) antibody (encoded as NCAB001), called 64Cu-NCAB001 ipPET. Generally, in clinical research, a radiometal-antibody complex must be prepared immediately before use at the imaging site. To make 64Cu-NCAB001 ipPET available to daily clinical practices in a sustainable way, the NCAB001-chelator conjugate and 64Cu-NCAB001 must be characterized and stabilized. NCAB001 was manufactured under cGMP conditions. NCAB001 was conjugated with a bifunctional chelator (p-SCN-Bn-PCTA), and the antibody-chelator conjugate (PCTA-NCAB001) was characterized by LC/MS and ELISA. Thereafter, to effectively manufacture 64Cu-NCAB001, we developed a new formulation to stabilize PCTA-NCAB001 and 64Cu-NCAB001. An average of three PCTA chelators were conjugated per molecule of NCAB001. The relative binding potency of PCTA-NCAB001 was comparable to cetuximab. The formulation consisting of acetate buffer, glycine, and polysorbate-80 stabilized PCTA-NCAB001 for a year-long storage. Additionally, this formulation enabled the stabilization of 64Cu-NCAB001 for up to 24 h after radiolabeling with a sufficient radioactivity concentration for clinical use. These results may accelerate the future use of 64Cu-NCAB001 ipPET in clinical settings for the early diagnosis and treatment of pancreatic cancer.
- Open Access
- 16 October 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (10) , 1706
Evaluation of Aminopolycarboxylate Chelators for Whole-Body Clearance of Free 225Ac: A Feasibility Study to Reduce Unexpected Radiation Exposure during Targeted Alpha Therapy
Actinium-225 (225Ac) is a promising radionuclide used in targeted alpha therapy (TAT). Although 225Ac labeling of bifunctional chelating ligands is effective, previous in vivo studies reported that free 225Ac can be released from the drugs and that such free 225Ac is predominantly accumulated in the liver and could cause unexpected toxicity. To accelerate the clinical development of 225Ac TAT with a variety of drugs, preparing methods to deal with any unexpected toxicity would be valuable. The aim of this study was to evaluate the feasibility of various chelators for reducing and excreting free 225Ac and compare their chemical structures. Nine candidate chelators (D-penicillamine, dimercaprol, Ca-DTPA, Ca-EDTA, CyDTA, GEDTA TTHA, Ca-TTHA, and DO3A) were evaluated in vitro and in vivo. The biodistribution and dosimetry of free 225Ac were examined in mice before an in vivo chelating study. The liver exhibited pronounced 225Ac uptake, with an estimated human absorbed dose of 4.76 SvRBE5/MBq. Aminopolycarboxylate chelators with five and six carboxylic groups, Ca-DTPA and Ca-TTHA, significantly reduced 225Ac retention in the liver (22% and 30%, respectively). Significant 225Ac reductions were observed in the heart and remainder of the body with both Ca-DTPA and Ca-TTHA, and in the lung, kidney, and spleen with Ca-TTHA. In vitro interaction analysis supported the in vivo reduction ability of Ca-DTPA and Ca-TTHA. In conclusion, aminopolycarboxylate chelators with five and six carboxylic groups, Ca-DTPA and Ca-TTHA, were effective for whole-body clearance of free 225Ac. This feasibility study provides useful information for reducing undesirable radiation exposure from free 225Ac.
- 16 October 2021
- Published by MDPI AG in Pharmaceutics
- Vol. 13 (10) , 1706
Open AccessEvaluation of Aminopolycarboxylate Chelators for Whole-Body Clearance of Free 225Ac: A Feasibility Study to Reduce Unexpected Radiation Exposure during Targeted Alpha Therapy
Actinium-225 (225Ac) is a promising radionuclide used in targeted alpha therapy (TAT). Although 225Ac labeling of bifunctional chelating ligands is effective, previous in vivo studies reported that free 225Ac can be released from the drugs and that such free 225Ac is predominantly accumulated in the liver and could cause unexpected toxicity. To accelerate the clinical development of 225Ac TAT with a variety of drugs, preparing methods to deal with any unexpected toxicity would be valuable. The aim of this study was to evaluate the feasibility of various chelators for reducing and excreting free 225Ac and compare their chemical structures. Nine candidate chelators (D-penicillamine, dimercaprol, Ca-DTPA, Ca-EDTA, CyDTA, GEDTA TTHA, Ca-TTHA, and DO3A) were evaluated in vitro and in vivo. The biodistribution and dosimetry of free 225Ac were examined in mice before an in vivo chelating study. The liver exhibited pronounced 225Ac uptake, with an estimated human absorbed dose of 4.76 SvRBE5/MBq. Aminopolycarboxylate chelators with five and six carboxylic groups, Ca-DTPA and Ca-TTHA, significantly reduced 225Ac retention in the liver (22% and 30%, respectively). Significant 225Ac reductions were observed in the heart and remainder of the body with both Ca-DTPA and Ca-TTHA, and in the lung, kidney, and spleen with Ca-TTHA. In vitro interaction analysis supported the in vivo reduction ability of Ca-DTPA and Ca-TTHA. In conclusion, aminopolycarboxylate chelators with five and six carboxylic groups, Ca-DTPA and Ca-TTHA, were effective for whole-body clearance of free 225Ac. This feasibility study provides useful information for reducing undesirable radiation exposure from free 225Ac.
- Open Access
- 23 September 2021
- Published by MDPI AG in Pharmaceuticals
- Vol. 14 (10) , 950
Evaluation of 64Cu-Labeled New Anti-EGFR Antibody NCAB001 with Intraperitoneal Injection for Early PET Diagnosis of Pancreatic Cancer in Orthotopic Tumor-Xenografted Mice and Nonhuman Primates
Objectives: To improve the prognosis of pancreatic cancer, new imaging methods to identify tumor lesions at a size of 64Cu-labeled new anti-epidermal growth factor receptor (EGFR) antibody (encoded as NCAB001), called 64Cu-NCAB001 ipPET. Methods: NCAB001 was manufactured under cGMP conditions and labeled with 64Cu. The radiochemical and biological properties of 64Cu-NCAB001 were evaluated. Tumor uptake of an ip-administered 64Cu-NCAB001 in mice with orthotopic pancreatic tumor xPA1-DC xenografts was also evaluated. Pharmacokinetics and radiation dosimetry were examined using PET images acquired after the ip administration of 64Cu-NCAB001 into cynomolgus monkeys with pharmacologic safety monitoring. Results: Radio-chromatography, cell-binding assays, and biodistribution of 64Cu-NCAB001 in mice were identical to those of our previous data with clinically available cetuximab. Small tumor lesions in the pancreas (≥3 mm) of mice could be identified by 64Cu-NCAB001 ipPET. The ip administration of 64Cu-NCAB001 into monkeys was safely conducted using ultrasound imaging. PET images in monkeys showed that ip-administered 64Cu-NCAB001 was distributed throughout the intraperitoneal cavity for up to 6 h and cleared thereafter. Most of the radioactivity was distributed in the liver and the large intestine. The radioactivity around the pancreas became negligible 24 h after administration. The estimated human effective dose was 0.0174 mSv/MBq. Conclusion: Our data support the initiation of clinical trials of 64Cu-NCAB001 ipPET to transfer this promising tool for the early diagnosis of pancreatic cancers.
- 23 September 2021
- Published by MDPI AG in Pharmaceuticals
- Vol. 14 (10) , 950
Open AccessEvaluation of 64Cu-Labeled New Anti-EGFR Antibody NCAB001 with Intraperitoneal Injection for Early PET Diagnosis of Pancreatic Cancer in Orthotopic Tumor-Xenografted Mice and Nonhuman Primates
Objectives: To improve the prognosis of pancreatic cancer, new imaging methods to identify tumor lesions at a size of 64Cu-labeled new anti-epidermal growth factor receptor (EGFR) antibody (encoded as NCAB001), called 64Cu-NCAB001 ipPET. Methods: NCAB001 was manufactured under cGMP conditions and labeled with 64Cu. The radiochemical and biological properties of 64Cu-NCAB001 were evaluated. Tumor uptake of an ip-administered 64Cu-NCAB001 in mice with orthotopic pancreatic tumor xPA1-DC xenografts was also evaluated. Pharmacokinetics and radiation dosimetry were examined using PET images acquired after the ip administration of 64Cu-NCAB001 into cynomolgus monkeys with pharmacologic safety monitoring. Results: Radio-chromatography, cell-binding assays, and biodistribution of 64Cu-NCAB001 in mice were identical to those of our previous data with clinically available cetuximab. Small tumor lesions in the pancreas (≥3 mm) of mice could be identified by 64Cu-NCAB001 ipPET. The ip administration of 64Cu-NCAB001 into monkeys was safely conducted using ultrasound imaging. PET images in monkeys showed that ip-administered 64Cu-NCAB001 was distributed throughout the intraperitoneal cavity for up to 6 h and cleared thereafter. Most of the radioactivity was distributed in the liver and the large intestine. The radioactivity around the pancreas became negligible 24 h after administration. The estimated human effective dose was 0.0174 mSv/MBq. Conclusion: Our data support the initiation of clinical trials of 64Cu-NCAB001 ipPET to transfer this promising tool for the early diagnosis of pancreatic cancers.
- Open Access
- 30 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (15) , 7031
Establishment of an In Vivo Xenograft Mouse Model of a Subcutaneous Submillimeter HT-29 Tumor Formed from a Single Spheroid Transplanted Using Radiation-Crosslinked Gelatin Hydrogel Microwell
Colorectal cancer is a frequent cause of death worldwide. The detection and treatment of small nodules are crucial for improving survival of colorectal cancer patients. Submillimeter tumors are useful tools for developing novel methods to approach this issue. However, there are no suitable in vivo models that allow easy monitoring of the growth of these tumors. This study established a xenograft mouse model of subcutaneous submillimeter tumors with human colorectal cancer HT-29 cells. We transplanted a single spheroid formed by HT-29 cells expressing red fluorescent protein (RFP) (HT-29-RFP). Additionally, we adopted our newly developed radiation-crosslinked gelatin hydrogel microwells (rGHMs), which can be used as a culture base to form spheroids and as a transplantation scaffold with biocompatibility and biodegradability. Spheroids approximately 700 μm in size were uniformly created in seven days in the respective rGHMs. Every single spheroid was extracted either with or without rGHM and transplanted into the subcutis of severe combined immunodeficiency (SCID) mice (n = 4). After 21 days, the spheroids inoculated together with rGHM successfully formed uniform subcutaneous submillimeter tumor xenografts that were observable in vivo in a stereoscopic fluorescence microscope in all transplanted mice. In contrast, spheroids transplanted without rGHM also developed small tumors in all mice but showed higher variability in size than those transplanted with rGHM. During transplantation, the rGHM ensured easy handling and stabilization of the position of a single spheroid. Inoculation of spheroids with rGHM in the nude mice was similarly examined (n = 4), showing that only one out of four mice formed tumors. In conclusion, rGHM effectively formed spheroids and created uniformed xenografted submillimeter tumors of HT-29-RFP in SCID mice. Our model could provide a useful platform to develop medicines and methods for detection and treatment of small nodules of colorectal cancer.
- 30 July 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (15) , 7031
Open AccessEstablishment of an In Vivo Xenograft Mouse Model of a Subcutaneous Submillimeter HT-29 Tumor Formed from a Single Spheroid Transplanted Using Radiation-Crosslinked Gelatin Hydrogel Microwell
Colorectal cancer is a frequent cause of death worldwide. The detection and treatment of small nodules are crucial for improving survival of colorectal cancer patients. Submillimeter tumors are useful tools for developing novel methods to approach this issue. However, there are no suitable in vivo models that allow easy monitoring of the growth of these tumors. This study established a xenograft mouse model of subcutaneous submillimeter tumors with human colorectal cancer HT-29 cells. We transplanted a single spheroid formed by HT-29 cells expressing red fluorescent protein (RFP) (HT-29-RFP). Additionally, we adopted our newly developed radiation-crosslinked gelatin hydrogel microwells (rGHMs), which can be used as a culture base to form spheroids and as a transplantation scaffold with biocompatibility and biodegradability. Spheroids approximately 700 μm in size were uniformly created in seven days in the respective rGHMs. Every single spheroid was extracted either with or without rGHM and transplanted into the subcutis of severe combined immunodeficiency (SCID) mice (n = 4). After 21 days, the spheroids inoculated together with rGHM successfully formed uniform subcutaneous submillimeter tumor xenografts that were observable in vivo in a stereoscopic fluorescence microscope in all transplanted mice. In contrast, spheroids transplanted without rGHM also developed small tumors in all mice but showed higher variability in size than those transplanted with rGHM. During transplantation, the rGHM ensured easy handling and stabilization of the position of a single spheroid. Inoculation of spheroids with rGHM in the nude mice was similarly examined (n = 4), showing that only one out of four mice formed tumors. In conclusion, rGHM effectively formed spheroids and created uniformed xenografted submillimeter tumors of HT-29-RFP in SCID mice. Our model could provide a useful platform to develop medicines and methods for detection and treatment of small nodules of colorectal cancer.