JJJean-Philippe Jeannot

Jean-Philippe Jeannot

*This is an algorithmically generated author record based on publicly available information.

Jean-Philippe Jeannot has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulation of Fluid Dynamics Monitoring Using Ultrasonic Measurements

    by Masaru Nagaso, Joseph Moysan, Christian Lhuillier, Jean-Philippe Jeannot

    The simulation of the propagation of ultrasonic waves in a moving fluid will improve the efficiency of the ultrasonic flow monitoring and that of the in-service monitoring for various reactors in several industries. The most recent simulations are mostly limited to 3D representations of the insonified volume but without really considering the temporal aspect of the flow. The advent of high-performance computing (HPC) now makes it possible to propose the first 4D simulations, with the representation of the inspected medium evolving over time. This work is based on a highly accurate double simulation. A first computational fluid dynamics (CFD) simulation, performed in previous work, described the fluid medium resulting from the mixing of hot jets in a cold opaque fluid. There have been many sensor developments over the years in this domain, as ultrasounds are the only method able to give information in an opaque medium. The correct design of these sensors, as well as the precise and confident analysis of their measurements, will progress with the development of the modeling of wave propagation in such a medium. An important parameter to consider is the flow temperature description, as a temperature gradient in the medium deflects the wave path and may sometimes cause its division. We develop a 4D wave propagation simulation in a very realistic, temporally fluctuating medium. A high-performance simulation is proposed in this work to include an ultrasonic source within the medium and to calculate the wave propagation between a transmitter and a receiver. The analysis of the wave variations shows that this through-transmission setup can track the jet mixing time variations. The steps needed to achieve these results are described using the spectral-element-based numerical tool SPECFEM3D. It is shown that the low-frequency fluctuation of the liquid metal flow can be observed using ultrasonic measurements.


  • Cavity Ring-Down Spectroscopy for Gaseous Fission Products Trace Measurements in Sodium Fast Reactors

    by P. Jacquet, A. Pailloux, G. Aoust, J.-P. Jeannot, D. Doizi

    Safety and reactor availability are key issues of the generation IV reactors. Hence, the three radionuclide confinement barriers, including the fuel pin cladding, must stay tight during the reactor operation. While manufacturing cladding failures evolve very slowly from a gaseous failure to an open failure, end of life and accidental failures may open very rapidly, generating a concerning situation. It is then important to detect the failure at the early stage through the gaseous fission products xenon and krypton, and evaluate the burning rate of the failed assembly. Therefore the ratio of stable over radioactive fission products needs to be measured. In the frame of the French ASTRID project, an optical spectroscopy technique-Cavity Ring-Down Spectroscopy (CRDS) - is developed to measure the gaseous fission product xenon, either stable or radioactive. A dedicated CRDS set-up, coupled with a glow discharge, is built to detect xenon with a commercial laser. A 6 ·10 -10 molar fraction of stable xenon over argon was measured by CRDS. With the present set-up, the detection limits are estimated from the baseline noise, to approximately 2 ·10 -11 for each even isotope, 6 ·10 -11 for the 131 Xe and 5.5 ·10 -11 for the 129 Xe. This sensitivity matches the specifications required for gaseous failure measurement. The odd isotopes are selectively measured, whereas the even isotopes overlap, a spectroscopic feature that applies for stable and radioactive xenon isotopes.