Agnès Pailloux
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Agnès Pailloux has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
C. Bray
CEA, DEN, DPC, F-91191 Gif sur Yvette, France
1 shared publication- Denis Doizi
CEA-Saclay, DES/ISAS/DRMP/SPC/LC2R, F-91190 Gif-sur-Yvette Cedex, France
1 shared publication - G. Aoust
Département Mesures Physiques, SLM, ONERA, Palaiseau cedex
1 shared publication - Jean-Philippe Jeannot
CEA/DES/IRESNE/DTN/STCP/LISM, 13108 St Paul lez Durance, France
1 shared publication P. Jacquet
CEA, DEN, DPC, Gif-sur-Yvette, France
1 shared publicationPatrick Jacquet
CEA, DEN, Département de Physico-Chimie, F-91 191 Gif-sur-Yvette, France
1 shared publication
Latest Publications
- 21 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (4) , 2011-2016
Cavity Ring-Down Spectroscopy for Gaseous Fission Products Trace Measurements in Sodium Fast Reactors
Safety and reactor availability are key issues of the generation IV reactors. Hence, the three radionuclide confinement barriers, including the fuel pin cladding, must stay tight during the reactor operation. While manufacturing cladding failures evolve very slowly from a gaseous failure to an open failure, end of life and accidental failures may open very rapidly, generating a concerning situation. It is then important to detect the failure at the early stage through the gaseous fission products xenon and krypton, and evaluate the burning rate of the failed assembly. Therefore the ratio of stable over radioactive fission products needs to be measured. In the frame of the French ASTRID project, an optical spectroscopy technique-Cavity Ring-Down Spectroscopy (CRDS) - is developed to measure the gaseous fission product xenon, either stable or radioactive. A dedicated CRDS set-up, coupled with a glow discharge, is built to detect xenon with a commercial laser. A 6 ·10 -10 molar fraction of stable xenon over argon was measured by CRDS. With the present set-up, the detection limits are estimated from the baseline noise, to approximately 2 ·10 -11 for each even isotope, 6 ·10 -11 for the 131 Xe and 5.5 ·10 -11 for the 129 Xe. This sensitivity matches the specifications required for gaseous failure measurement. The odd isotopes are selectively measured, whereas the even isotopes overlap, a spectroscopic feature that applies for stable and radioactive xenon isotopes.
- 21 April 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 61 (4) , 2011-2016
Cavity Ring-Down Spectroscopy for Gaseous Fission Products Trace Measurements in Sodium Fast Reactors
Safety and reactor availability are key issues of the generation IV reactors. Hence, the three radionuclide confinement barriers, including the fuel pin cladding, must stay tight during the reactor operation. While manufacturing cladding failures evolve very slowly from a gaseous failure to an open failure, end of life and accidental failures may open very rapidly, generating a concerning situation. It is then important to detect the failure at the early stage through the gaseous fission products xenon and krypton, and evaluate the burning rate of the failed assembly. Therefore the ratio of stable over radioactive fission products needs to be measured. In the frame of the French ASTRID project, an optical spectroscopy technique-Cavity Ring-Down Spectroscopy (CRDS) - is developed to measure the gaseous fission product xenon, either stable or radioactive. A dedicated CRDS set-up, coupled with a glow discharge, is built to detect xenon with a commercial laser. A 6 ·10 -10 molar fraction of stable xenon over argon was measured by CRDS. With the present set-up, the detection limits are estimated from the baseline noise, to approximately 2 ·10 -11 for each even isotope, 6 ·10 -11 for the 131 Xe and 5.5 ·10 -11 for the 129 Xe. This sensitivity matches the specifications required for gaseous failure measurement. The odd isotopes are selectively measured, whereas the even isotopes overlap, a spectroscopic feature that applies for stable and radioactive xenon isotopes.
- 15 May 2013
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 28 (8) , 1298-1302
Laser absorption spectroscopy for xenon monitoring in the cover gas of sodium cooled fast reactors
Xenon is a fission product of uranium that must be monitored on line and in real time in the cover gas of a sodium cooled fast neutron reactor (SFR) for safety reasons. In this paper, tunable diode laser absorption spectroscopy is applied to quantify low concentrations of natural xenon in argon. Optical detection is carried out at 12 145 cm−1 (823 nm) from the 6s[3/2]0 2 Xe electronic metastable state, populated in a low pressure DC glow discharge. Optimal discharge parameters (110 Pa, 1.3 W) were experimentally determined to maximize the laser absorption signal. Measurement stability, argon pressure spectral broadening, isotope quantification, and linearity of the optical measurement with respect to the xenon concentration in the gas sample were carefully investigated. Under optimized experimental conditions, the detection limit of xenon over argon molar ratio is estimated as 60 ± 10 parts per billion at 1 Hz, corresponding to a xenon number density of 1.6 × 109 atoms.cm−3 along the laser beam.
- 15 May 2013
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 28 (8) , 1298-1302
Laser absorption spectroscopy for xenon monitoring in the cover gas of sodium cooled fast reactors
Xenon is a fission product of uranium that must be monitored on line and in real time in the cover gas of a sodium cooled fast neutron reactor (SFR) for safety reasons. In this paper, tunable diode laser absorption spectroscopy is applied to quantify low concentrations of natural xenon in argon. Optical detection is carried out at 12 145 cm−1 (823 nm) from the 6s[3/2]0 2 Xe electronic metastable state, populated in a low pressure DC glow discharge. Optimal discharge parameters (110 Pa, 1.3 W) were experimentally determined to maximize the laser absorption signal. Measurement stability, argon pressure spectral broadening, isotope quantification, and linearity of the optical measurement with respect to the xenon concentration in the gas sample were carefully investigated. Under optimized experimental conditions, the detection limit of xenon over argon molar ratio is estimated as 60 ± 10 parts per billion at 1 Hz, corresponding to a xenon number density of 1.6 × 109 atoms.cm−3 along the laser beam.