Wei Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Wei Yin has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Xudong Zhang
Department of Industrial and Systems Engineering, Texas A&M University, College Station, USA
3 shared publications Curran Reddy
Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA
2 shared publications- Giovanni Oppizzi
Department of Bioengineering, University of Maryland, College Park, MD, USA
2 shared publications - Li-Qun Zhang
Department of Physical Therapy and Rehabilitation Science, University of Maryland, Baltimore, MD, USA
2 shared publications Raziyeh Baghi
Department of Physical Therapy and Rehabilitation Science, University of Maryland, Baltimore, MD, USA
2 shared publicationsChenghao Lv
SAIC Motor Corporation Limited, Shanghai, 200041, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 3329-3338
Effects of Subject-Specific Robot-Guided Off-Axis Stepping Training in Individuals With Medial Knee Osteoarthritis
Elevated peak knee adduction moment (pKAM) has been identified as a critical biomechanical factor driving medial knee osteoarthritis (KOA) initiation and concurrent reductions in medial compartment overloading and improvements in frontal-plane neuromuscular control during functional weight-bearing stepping movements.progression, while impaired frontal plane neuromuscular control contributes to joint instability and accelerated disease advancement. Although gait modification strategies using real-time biofeedback have demonstrated pKAM reductions, most interventions apply the same modifications to all individuals and do not fully evaluate the combined effects of KAM reduction training and neuromuscular control training on joint loading, neuromuscular stability, and functional outcomes. A subject-specific robotic off-axis elliptical training system was developed to improve frontal plane neuromuscular control and reduce pKAM through foot progression angle (FPA) modification individually. Effects of the six-week subject-specific off-axis stepping training in reducing excessive knee loading and improving frontal-plane stability were demonstrated through 18 supervised training sessions in thirteen individuals with medial KOA. The training system perturbed the FPA slowly during continuous stepping without the subject noticing the perturbation to identify the optimal FPA for a targeted pKAM reduction. Furthermore, the optimized FPA was combined with real-time three-dimensional knee moment feedback and frontal plane footplate free-sliding challenges were used in the training. After the six-week training, participants demonstrated significant reductions in pKAM, sliding instability and maximum lateral sliding distance, while stepping speed increased significantly. Clinical outcomes showed improvements in KOOS Symptoms and Pain subscales. Functional performance enhanced in the 20-meter walk test, 30-second sit-to-stand test, overground gait velocity, and bilateral step length. Importantly, improvements in frontal plane stability metrics were maintained at six-week follow-up, suggesting lasting neuromuscular adaptations. The results indicate that robotic off-axis elliptical training with FPA optimization can potentially be used as a subject-specific therapeutic and research tool to train individuals with medial KOA for concurrent reductions in medial compartment overloading and improvements in frontal-plane neuromuscular control during functional weight-bearing stepping movements.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34, 3329-3338
Open AccessEffects of Subject-Specific Robot-Guided Off-Axis Stepping Training in Individuals With Medial Knee Osteoarthritis
Elevated peak knee adduction moment (pKAM) has been identified as a critical biomechanical factor driving medial knee osteoarthritis (KOA) initiation and concurrent reductions in medial compartment overloading and improvements in frontal-plane neuromuscular control during functional weight-bearing stepping movements.progression, while impaired frontal plane neuromuscular control contributes to joint instability and accelerated disease advancement. Although gait modification strategies using real-time biofeedback have demonstrated pKAM reductions, most interventions apply the same modifications to all individuals and do not fully evaluate the combined effects of KAM reduction training and neuromuscular control training on joint loading, neuromuscular stability, and functional outcomes. A subject-specific robotic off-axis elliptical training system was developed to improve frontal plane neuromuscular control and reduce pKAM through foot progression angle (FPA) modification individually. Effects of the six-week subject-specific off-axis stepping training in reducing excessive knee loading and improving frontal-plane stability were demonstrated through 18 supervised training sessions in thirteen individuals with medial KOA. The training system perturbed the FPA slowly during continuous stepping without the subject noticing the perturbation to identify the optimal FPA for a targeted pKAM reduction. Furthermore, the optimized FPA was combined with real-time three-dimensional knee moment feedback and frontal plane footplate free-sliding challenges were used in the training. After the six-week training, participants demonstrated significant reductions in pKAM, sliding instability and maximum lateral sliding distance, while stepping speed increased significantly. Clinical outcomes showed improvements in KOOS Symptoms and Pain subscales. Functional performance enhanced in the 20-meter walk test, 30-second sit-to-stand test, overground gait velocity, and bilateral step length. Importantly, improvements in frontal plane stability metrics were maintained at six-week follow-up, suggesting lasting neuromuscular adaptations. The results indicate that robotic off-axis elliptical training with FPA optimization can potentially be used as a subject-specific therapeutic and research tool to train individuals with medial KOA for concurrent reductions in medial compartment overloading and improvements in frontal-plane neuromuscular control during functional weight-bearing stepping movements.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. PP, 1
Combining Cognitive and Sensorimotor Assessments to Facilitate Detection of Age-Related Cognitive Decline
Early detection of cognitive decline is critical for reducing progression of neurodegenerative diseases. Bioimaging- and biofluids- based approaches are invasive and expensive; clinical screening tools have difficulties in discerning subtle cognitive changes. Eye tracking measures have been used to detect cognitive deficits effectively and reduction in sensorimotor performance may precede cognitive declines by several years. Therefore, we developed a combined cognitive and sensorimotor evaluation system by integrating an arm-hand exoskeleton and an eye-tracking device to facilitate the early detection of cognitive decline. Three combined cognitive and sensorimotor tests were investigated: combined anti-saccade motor test (CASMT), combined anti-saccade sensory test (CASST), and combined trail-making test B (CTMT-B). The combined tests were compared to conventional anti-saccade test (AST). Thirty-two healthy subjects, including 16 young subjects and 16 older adults, participated in the study. Results showed that the combined assessment better detected cognitive differences between older and young subjects than cognitive (eye-tracking) test alone. Specifically, 1) in CASMT, older subjects exhibited significantly longer eye movement latency than the young subjects (p<0.001), while AST did not show such a difference. 2) in CASST, older adults showed longer latency in both eye (p=0.003) and wrist (p=0.005) movement than young subjects. 3) in CTMT-B, older adults took longer time to reach the targets (p<0.001) and dwell longer at the targets (p<0.001) than young subjects; older adults also showed more saccades during hand cursor reaching and dwelling, and lower cursor movement smoothness (p<0.005). Furthermore, classification algorithms were used to predict participants' age groups, with the top six best-performing models confirming that sensorimotor outcome measures from CTMT-B, particularly the cursor movement smoothness, are highly influential, indicating the combined approach improves detection of cognitive changes. Correlation analysis further confirmed statistically significant negative correlation coefficients between MoCA results and outcome measures from CASMT and CTMT-B. The combined cognitive and sensorimotor tests showed more sensitive detections of cognitive and sensorimotor changes than the tests based on eye-tracking alone, and can potentially facilitate early detection of cognitive declines.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. PP, 1
Open AccessCombining Cognitive and Sensorimotor Assessments to Facilitate Detection of Age-Related Cognitive Decline
Early detection of cognitive decline is critical for reducing progression of neurodegenerative diseases. Bioimaging- and biofluids- based approaches are invasive and expensive; clinical screening tools have difficulties in discerning subtle cognitive changes. Eye tracking measures have been used to detect cognitive deficits effectively and reduction in sensorimotor performance may precede cognitive declines by several years. Therefore, we developed a combined cognitive and sensorimotor evaluation system by integrating an arm-hand exoskeleton and an eye-tracking device to facilitate the early detection of cognitive decline. Three combined cognitive and sensorimotor tests were investigated: combined anti-saccade motor test (CASMT), combined anti-saccade sensory test (CASST), and combined trail-making test B (CTMT-B). The combined tests were compared to conventional anti-saccade test (AST). Thirty-two healthy subjects, including 16 young subjects and 16 older adults, participated in the study. Results showed that the combined assessment better detected cognitive differences between older and young subjects than cognitive (eye-tracking) test alone. Specifically, 1) in CASMT, older subjects exhibited significantly longer eye movement latency than the young subjects (p<0.001), while AST did not show such a difference. 2) in CASST, older adults showed longer latency in both eye (p=0.003) and wrist (p=0.005) movement than young subjects. 3) in CTMT-B, older adults took longer time to reach the targets (p<0.001) and dwell longer at the targets (p<0.001) than young subjects; older adults also showed more saccades during hand cursor reaching and dwelling, and lower cursor movement smoothness (p<0.005). Furthermore, classification algorithms were used to predict participants' age groups, with the top six best-performing models confirming that sensorimotor outcome measures from CTMT-B, particularly the cursor movement smoothness, are highly influential, indicating the combined approach improves detection of cognitive changes. Correlation analysis further confirmed statistically significant negative correlation coefficients between MoCA results and outcome measures from CASMT and CTMT-B. The combined cognitive and sensorimotor tests showed more sensitive detections of cognitive and sensorimotor changes than the tests based on eye-tracking alone, and can potentially facilitate early detection of cognitive declines.
- 6 June 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 171, 112181
Advanced subject-specific neck musculoskeletal modeling unveils sex differences in muscle moment arm and cervical spine loading
- 6 June 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 171, 112181
Advanced subject-specific neck musculoskeletal modeling unveils sex differences in muscle moment arm and cervical spine loading
- 26 May 2023
- Published by Taylor & Francis in Ergonomics
- Vol. 67 (2) , 182-193
Flexible sensor-based biomechanical evaluation of low-back exoskeleton use in lifting
This study aimed to establish an ambulatory field-friendly system based on miniaturised wireless flexible sensors for studying the biomechanics of human-exoskeleton interactions. Twelve healthy adults performed symmetric lifting with and without a passive low-back exoskeleton, while their movements were tracked using both a flexible sensor system and a conventional motion capture (MoCap) system synchronously. Novel algorithms were developed to convert the raw acceleration, gyroscope, and biopotential signals from the flexible sensors into kinematic and dynamic measures. Results showed that these measures were highly correlated with those obtained from the MoCap system and discerned the effects of the exoskeleton, including increased peak lumbar flexion, decreased peak hip flexion, and decreased lumbar flexion moment and back muscle activities. The study demonstrated the promise of an integrated flexible sensor-based system for biomechanics and ergonomics field studies as well as the efficacy of exoskeleton in relieving the low-back stress associated with manual lifting.
- 26 May 2023
- Published by Taylor & Francis in Ergonomics
- Vol. 67 (2) , 182-193
Flexible sensor-based biomechanical evaluation of low-back exoskeleton use in lifting
This study aimed to establish an ambulatory field-friendly system based on miniaturised wireless flexible sensors for studying the biomechanics of human-exoskeleton interactions. Twelve healthy adults performed symmetric lifting with and without a passive low-back exoskeleton, while their movements were tracked using both a flexible sensor system and a conventional motion capture (MoCap) system synchronously. Novel algorithms were developed to convert the raw acceleration, gyroscope, and biopotential signals from the flexible sensors into kinematic and dynamic measures. Results showed that these measures were highly correlated with those obtained from the MoCap system and discerned the effects of the exoskeleton, including increased peak lumbar flexion, decreased peak hip flexion, and decreased lumbar flexion moment and back muscle activities. The study demonstrated the promise of an integrated flexible sensor-based system for biomechanics and ergonomics field studies as well as the efficacy of exoskeleton in relieving the low-back stress associated with manual lifting.
- 6 August 2021
- Published by Taylor & Francis in Ergonomics
- Vol. 65 (1) , 91-104
Physical and cognitive demands associated with police in-vehicle technology use: an on-road case study
Motor vehicle crashes are a leading cause of police officers’ deaths in line of duty. These crashes have been mainly attributed to officers’ driving distraction caused by the use of in-vehicle technologies while driving. This paper presents a 3-h ride-along study of 20 police officers to assess the physical and cognitive demands associated with using in-vehicle technologies. The findings suggested that the mobile computer terminal (MCT) was the most frequently used in-vehicle system for the officers. In addition, officers perceived the MCT to significantly increase their visual, cognitive, and physical demands compared to other in-vehicle technologies. Evidence from electromyography and eye-tracking measures suggested that officers with more experience as a patrol officer and those who were working in more congested areas experienced higher cognitive workload. Furthermore, it was found that as the ride-along duration increased, there were indications of muscle fatigue in medial deltoid and triceps brachii muscles. Practitioner summary: This study assessed the impact of police in-vehicle technology use in an on-road case study. The findings provide new data and knowledge for police agencies and vehicle manufacturers to develop administrative measures and in-vehicle technology innovations to improve police officers’ health and safety.
- 6 August 2021
- Published by Taylor & Francis in Ergonomics
- Vol. 65 (1) , 91-104
Physical and cognitive demands associated with police in-vehicle technology use: an on-road case study
Motor vehicle crashes are a leading cause of police officers’ deaths in line of duty. These crashes have been mainly attributed to officers’ driving distraction caused by the use of in-vehicle technologies while driving. This paper presents a 3-h ride-along study of 20 police officers to assess the physical and cognitive demands associated with using in-vehicle technologies. The findings suggested that the mobile computer terminal (MCT) was the most frequently used in-vehicle system for the officers. In addition, officers perceived the MCT to significantly increase their visual, cognitive, and physical demands compared to other in-vehicle technologies. Evidence from electromyography and eye-tracking measures suggested that officers with more experience as a patrol officer and those who were working in more congested areas experienced higher cognitive workload. Furthermore, it was found that as the ride-along duration increased, there were indications of muscle fatigue in medial deltoid and triceps brachii muscles. Practitioner summary: This study assessed the impact of police in-vehicle technology use in an on-road case study. The findings provide new data and knowledge for police agencies and vehicle manufacturers to develop administrative measures and in-vehicle technology innovations to improve police officers’ health and safety.
- 23 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 51 (4) , 346-354
A Novel Application of Flexible Inertial Sensors for Ambulatory Measurement of Gait Kinematics
Ambulatory motion sensors can generate a mobile system for human kinematics measurement as an alternative to the more constrained optical motion capture systems. Flexible inertial sensors are emerging as a potential solution to overcome the drawback of the conventional inertial measurement sensors with a soft, flexible design that allows for direct body-conforming adhesion to the skin. Thus, this study aims to establish the viability of the flexible inertial sensors for the ambulatory measurement of human knee flexion-extension (F/E) during level walking. The accuracy of flexible inertial sensors with our proposed algorithm is investigated by comparing the derived kinematics with those measured using a conventional motion capture system. Three volunteers (two males and one female, aged 24-27) served as subjects. Three flexible inertial sensors were placed on the subjects' right legs, two on the thigh (lateral thigh and distal anterolateral thigh), and one on the lateral shank, and subjects performed level walking with varied walking cadence (80, 100, and 120 steps/min). The overall root-mean-square-error across all participants is 7.8° for distal anterolateral thigh sensor (using the data of distal anterolateral thigh sensor and shank sensor to estimate knee F/E) and 4.5° for lateral thigh sensor (using the data of lateral thigh sensor and shank sensor to estimate knee F/E). The results illustrate that our proposed method can generate comparable results with motion capture systems and is insensitive to different walking cadence. A significant effect of sensor placement is observed, and a more proximal lateral thigh strategy is suggested. The advantages of the flexible inertial sensors in human motion analysis over the existing inertial measurement units are also highlighted.
- 23 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 51 (4) , 346-354
A Novel Application of Flexible Inertial Sensors for Ambulatory Measurement of Gait Kinematics
Ambulatory motion sensors can generate a mobile system for human kinematics measurement as an alternative to the more constrained optical motion capture systems. Flexible inertial sensors are emerging as a potential solution to overcome the drawback of the conventional inertial measurement sensors with a soft, flexible design that allows for direct body-conforming adhesion to the skin. Thus, this study aims to establish the viability of the flexible inertial sensors for the ambulatory measurement of human knee flexion-extension (F/E) during level walking. The accuracy of flexible inertial sensors with our proposed algorithm is investigated by comparing the derived kinematics with those measured using a conventional motion capture system. Three volunteers (two males and one female, aged 24-27) served as subjects. Three flexible inertial sensors were placed on the subjects' right legs, two on the thigh (lateral thigh and distal anterolateral thigh), and one on the lateral shank, and subjects performed level walking with varied walking cadence (80, 100, and 120 steps/min). The overall root-mean-square-error across all participants is 7.8° for distal anterolateral thigh sensor (using the data of distal anterolateral thigh sensor and shank sensor to estimate knee F/E) and 4.5° for lateral thigh sensor (using the data of lateral thigh sensor and shank sensor to estimate knee F/E). The results illustrate that our proposed method can generate comparable results with motion capture systems and is insensitive to different walking cadence. A significant effect of sensor placement is observed, and a more proximal lateral thigh strategy is suggested. The advantages of the flexible inertial sensors in human motion analysis over the existing inertial measurement units are also highlighted.
- Open Access
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 137, 171-179
A Quantitative Model of Conflict Risk Degree at Non-Signalized Intersections
- 1 January 2016
- Published by Elsevier in Procedia Engineering
- Vol. 137, 171-179
Open AccessA Quantitative Model of Conflict Risk Degree at Non-Signalized Intersections