SBSarah Bouari

Sarah Bouari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sarah Bouari has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Normothermic versus hypothermic machine perfusion in kidney transplantation: A randomized controlled trial

    by Julia S. Slagter, Sarah Bouari, Elsaline Rijkse, Iacopo Cristoferi, Yitian Fang, Agni Papamanoli, Andrew Stubbs, Jeroen de Jonge, Ron W.F. de Bruin, Martijn W.F. van Den Hoogen, et al.


  • Open Access

    Metabolite-enhanced normothermic machine perfusion improves kidney transplant viability

    by Jan Czogalla, Fabian Hausmann, Simon Lagies, Sydney E. Gies, Sabrina Christiansen, Nico Kaiser, Fabian Haas, Yusuke Okabayashi, Dominik Kylies, Smilla Hofmann, et al.

    Normothermic machine perfusion (NMP) has become a valuable tool to expand the pool of transplantable organs. However, the application of NMP to kidneys presents substantial challenges, mostly due to high variability in the composition of currently used perfusion solutions. Here, we provide a multimodal cross-species cellular atlas of kidney injury associated with NMP using a literature-based consensus buffer. This resource provided a systematic framework that was used to develop a metabolite-enhanced perfusion solution, which protected renal proximal tubular cells, improving cellular viability and transplantation outcomes across species, including human kidneys.


  • Ex situ machine perfusion in kidney transplantation

    by Sarah Bouari, Elsaline Rijkse, Sarah A. Hosgood, Robert C. Minnee


  • Open Access

    Optimizing porcine donor kidney preservation with normothermic or hypothermic machine perfusion: A systematic review

    by Sarah Bouari, Özgür Eryigit, Ron W. F. de Bruin, Jan N. M. Ijzermans, Robert C. Minnee

    We present an updated overview of the literature comparing normothermic with hypothermic machine perfusion in porcine kidneys. We conducted a systematic literature review in Embase, Medline Epub (Ovid), Cochrane Central, Web of Science, and Google Scholar on studies comparing normothermic (NMP) to hypothermic machine perfusion (HMP) in porcine kidneys. A meta‐analysis was judged inappropriate because of heterogeneity in study design and perfusion methods. The quality of evidence of each included study was assessed. We included 8 studies. One out of 5 studies reported a significant difference in peak renal blood flow in favor of NMP. Oxygen consumption was significantly higher in NMP kidneys in 2 out of 5 studies. Peak creatinine clearance in NMP was significantly higher than that in HMP in 1 out of 6 studies. Two out of 4 studies reported a higher degree of epithelial vacuolation in kidneys receiving NMP over HMP. None of the studies found a significant difference between NMP and HMP in peak serum creatinine or graft survival after autotransplantation. The results need to be interpreted with caution in view of the diversity in perfusion protocols, the low quality of evidence, and the limited sample sizes.


  • Open Access

    Additional Normothermic Machine Perfusion Versus Hypothermic Machine Perfusion in Suboptimal Donor Kidney Transplantation: Protocol of a Randomized, Controlled, Open-Label Trial

    by Elsaline Rijkse, Sarah Bouari, Hendrikus J. A. N. Kimenai, Jeroen DE Jonge, Ron W. F. DE Bruin, Julia S. Slagter, Martijn W. F. VAN Den Hoogen, Jan N. M. Ijzermans, Martin J. Hoogduijn, Robert C. Minnee

    : Introduction: Ageing of the general population has led to an increase in the use of suboptimal kidneys from expanded criteria donation after brain death (ECD-DBD) and donation after circulatory death (DCD) donors. However, these kidneys have inferior graft outcomes and lower rates of immediate function. Normothermic machine perfusion (NMP) may improve outcomes of these suboptimal donor kidneys. Previous non-randomized studies have shown the safety of this technique and suggested its efficacy in improving the proportion of immediate functioning kidneys compared to static cold storage (SCS). However, its additional value to hypothermic machine perfusion (HMP), which has already been proved superior to SCS, has not yet been established. Methods and analysis: This single-center, open-label, randomized controlled trial aims to assess immediate kidney function after 120 minutes additional, end-ischemic NMP compared to HMP alone. Immediate kidney function is defined as no dialysis treatment in the first week after transplant. Eighty recipients on dialysis at the time of transplant who receive an ECD-DBD or DCD kidney graft are eligible for inclusion. In the NMP group, the donor kidney is taken of HMP upon arrival in the recipient hospital and thereafter put on NMP for 120 minutes at 37 degrees Celsius followed by transplantation. In the control group, donor kidneys stay on HMP until transplantation. The primary outcome is immediate kidney function. Ethics and dissemination: The protocol has been approved by the Medical Ethical Committee of Erasmus Medical Center (2020-0366). Results of this study will be submitted to peer-reviewed journals. Registration: registered in clinicaltrials.gov (NCT04882254). Highlights: