Sarah Bouari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sarah Bouari has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Robert C. Minnee
Division of HPB and Transplant Surgery, Department of Surgery, Erasmus MC Transplant Institute, Erasmus University Medical Center, Rotterdam, the Netherlands
5 shared publications - Elsaline Rijkse
Erasmus MC Transplant Institute, Division of HPB and Transplant Surgery, Department of Surgery, Erasmus MC University Medical Centre, Rotterdam, the Netherlands
2 shared publications - Hendrikus J. A. N. Kimenai
Department of Surgery, Division of Hepatobiliary and Transplant Surgery, Erasmus MC Transplant Institute, University Medical Center Rotterdam, Rotterdam, the Netherlands
2 shared publications - Jeroen de Jonge
Department of Surgery, Division of Hepato-Pancreato-Biliary and Transplant Surgery, Erasmus MC Transplant Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands
2 shared publications - Julia S. Slagter
Division of HPB and Transplant Surgery, Department of Surgery Erasmus MC Transplant Institute, Erasmus Medical Center Rotterdam the Netherlands
2 shared publications - Martijn W. F. VAN Den Hoogen
Department of Internal Medicine, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 24 December 2025
- Published by Elsevier in American Journal of Transplantation
- Vol. 26 (5) , 1070-1079
Normothermic versus hypothermic machine perfusion in kidney transplantation: A randomized controlled trial
- 24 December 2025
- Published by Elsevier in American Journal of Transplantation
- Vol. 26 (5) , 1070-1079
Open AccessNormothermic versus hypothermic machine perfusion in kidney transplantation: A randomized controlled trial
- Open Access
- 23 September 2025
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 10 (20)
Metabolite-enhanced normothermic machine perfusion improves kidney transplant viability
Normothermic machine perfusion (NMP) has become a valuable tool to expand the pool of transplantable organs. However, the application of NMP to kidneys presents substantial challenges, mostly due to high variability in the composition of currently used perfusion solutions. Here, we provide a multimodal cross-species cellular atlas of kidney injury associated with NMP using a literature-based consensus buffer. This resource provided a systematic framework that was used to develop a metabolite-enhanced perfusion solution, which protected renal proximal tubular cells, improving cellular viability and transplantation outcomes across species, including human kidneys.
- 23 September 2025
- Published by American Society for Clinical Investigation in JCI Insight
- Vol. 10 (20)
Open AccessMetabolite-enhanced normothermic machine perfusion improves kidney transplant viability
Normothermic machine perfusion (NMP) has become a valuable tool to expand the pool of transplantable organs. However, the application of NMP to kidneys presents substantial challenges, mostly due to high variability in the composition of currently used perfusion solutions. Here, we provide a multimodal cross-species cellular atlas of kidney injury associated with NMP using a literature-based consensus buffer. This resource provided a systematic framework that was used to develop a metabolite-enhanced perfusion solution, which protected renal proximal tubular cells, improving cellular viability and transplantation outcomes across species, including human kidneys.
- 9 December 2021
- Published by Wiley in Artificial Organs
- Vol. 46 (2) , 173-176
Ex situ machine perfusion in kidney transplantation
- 9 December 2021
- Published by Wiley in Artificial Organs
- Vol. 46 (2) , 173-176
Ex situ machine perfusion in kidney transplantation
- Open Access
- 26 July 2021
- Published by Wiley in Artificial Organs
- Vol. 45 (11) , 1308-1316
Optimizing porcine donor kidney preservation with normothermic or hypothermic machine perfusion: A systematic review
We present an updated overview of the literature comparing normothermic with hypothermic machine perfusion in porcine kidneys. We conducted a systematic literature review in Embase, Medline Epub (Ovid), Cochrane Central, Web of Science, and Google Scholar on studies comparing normothermic (NMP) to hypothermic machine perfusion (HMP) in porcine kidneys. A meta‐analysis was judged inappropriate because of heterogeneity in study design and perfusion methods. The quality of evidence of each included study was assessed. We included 8 studies. One out of 5 studies reported a significant difference in peak renal blood flow in favor of NMP. Oxygen consumption was significantly higher in NMP kidneys in 2 out of 5 studies. Peak creatinine clearance in NMP was significantly higher than that in HMP in 1 out of 6 studies. Two out of 4 studies reported a higher degree of epithelial vacuolation in kidneys receiving NMP over HMP. None of the studies found a significant difference between NMP and HMP in peak serum creatinine or graft survival after autotransplantation. The results need to be interpreted with caution in view of the diversity in perfusion protocols, the low quality of evidence, and the limited sample sizes.
- 26 July 2021
- Published by Wiley in Artificial Organs
- Vol. 45 (11) , 1308-1316
Open AccessOptimizing porcine donor kidney preservation with normothermic or hypothermic machine perfusion: A systematic review
We present an updated overview of the literature comparing normothermic with hypothermic machine perfusion in porcine kidneys. We conducted a systematic literature review in Embase, Medline Epub (Ovid), Cochrane Central, Web of Science, and Google Scholar on studies comparing normothermic (NMP) to hypothermic machine perfusion (HMP) in porcine kidneys. A meta‐analysis was judged inappropriate because of heterogeneity in study design and perfusion methods. The quality of evidence of each included study was assessed. We included 8 studies. One out of 5 studies reported a significant difference in peak renal blood flow in favor of NMP. Oxygen consumption was significantly higher in NMP kidneys in 2 out of 5 studies. Peak creatinine clearance in NMP was significantly higher than that in HMP in 1 out of 6 studies. Two out of 4 studies reported a higher degree of epithelial vacuolation in kidneys receiving NMP over HMP. None of the studies found a significant difference between NMP and HMP in peak serum creatinine or graft survival after autotransplantation. The results need to be interpreted with caution in view of the diversity in perfusion protocols, the low quality of evidence, and the limited sample sizes.
- Open Access
- 1 January 2021
- Published by Wolters Kluwer Health in International Journal of Surgery Protocols
- Vol. 25 (1) , 227-237
Additional Normothermic Machine Perfusion Versus Hypothermic Machine Perfusion in Suboptimal Donor Kidney Transplantation: Protocol of a Randomized, Controlled, Open-Label Trial
: Introduction: Ageing of the general population has led to an increase in the use of suboptimal kidneys from expanded criteria donation after brain death (ECD-DBD) and donation after circulatory death (DCD) donors. However, these kidneys have inferior graft outcomes and lower rates of immediate function. Normothermic machine perfusion (NMP) may improve outcomes of these suboptimal donor kidneys. Previous non-randomized studies have shown the safety of this technique and suggested its efficacy in improving the proportion of immediate functioning kidneys compared to static cold storage (SCS). However, its additional value to hypothermic machine perfusion (HMP), which has already been proved superior to SCS, has not yet been established. Methods and analysis: This single-center, open-label, randomized controlled trial aims to assess immediate kidney function after 120 minutes additional, end-ischemic NMP compared to HMP alone. Immediate kidney function is defined as no dialysis treatment in the first week after transplant. Eighty recipients on dialysis at the time of transplant who receive an ECD-DBD or DCD kidney graft are eligible for inclusion. In the NMP group, the donor kidney is taken of HMP upon arrival in the recipient hospital and thereafter put on NMP for 120 minutes at 37 degrees Celsius followed by transplantation. In the control group, donor kidneys stay on HMP until transplantation. The primary outcome is immediate kidney function. Ethics and dissemination: The protocol has been approved by the Medical Ethical Committee of Erasmus Medical Center (2020-0366). Results of this study will be submitted to peer-reviewed journals. Registration: registered in clinicaltrials.gov (NCT04882254). Highlights:
- 1 January 2021
- Published by Wolters Kluwer Health in International Journal of Surgery Protocols
- Vol. 25 (1) , 227-237
Open AccessAdditional Normothermic Machine Perfusion Versus Hypothermic Machine Perfusion in Suboptimal Donor Kidney Transplantation: Protocol of a Randomized, Controlled, Open-Label Trial
: Introduction: Ageing of the general population has led to an increase in the use of suboptimal kidneys from expanded criteria donation after brain death (ECD-DBD) and donation after circulatory death (DCD) donors. However, these kidneys have inferior graft outcomes and lower rates of immediate function. Normothermic machine perfusion (NMP) may improve outcomes of these suboptimal donor kidneys. Previous non-randomized studies have shown the safety of this technique and suggested its efficacy in improving the proportion of immediate functioning kidneys compared to static cold storage (SCS). However, its additional value to hypothermic machine perfusion (HMP), which has already been proved superior to SCS, has not yet been established. Methods and analysis: This single-center, open-label, randomized controlled trial aims to assess immediate kidney function after 120 minutes additional, end-ischemic NMP compared to HMP alone. Immediate kidney function is defined as no dialysis treatment in the first week after transplant. Eighty recipients on dialysis at the time of transplant who receive an ECD-DBD or DCD kidney graft are eligible for inclusion. In the NMP group, the donor kidney is taken of HMP upon arrival in the recipient hospital and thereafter put on NMP for 120 minutes at 37 degrees Celsius followed by transplantation. In the control group, donor kidneys stay on HMP until transplantation. The primary outcome is immediate kidney function. Ethics and dissemination: The protocol has been approved by the Medical Ethical Committee of Erasmus Medical Center (2020-0366). Results of this study will be submitted to peer-reviewed journals. Registration: registered in clinicaltrials.gov (NCT04882254). Highlights: