Josep Martí Sanahuja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Josep Martí Sanahuja has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Alejandra Garrido
MiWEndo Solutions S.L., 08014 Barcelona, Spain
3 shared publications - Gloria Fernández-Esparrach
Endoscopy Unit, Gastroenterology Department, ICMDM, Hospital Clinic, UB, C/Villarroel 170, 08036 Barcelona, Spain
3 shared publications - Marta Guardiola
MiWEndo Solutions, Barcelona, Spain
3 shared publications - Amelia J. Hessheimer
Hepatopancreatobiliary Surgery & Transplantation, General & Digestive Surgery Service Hospital Universitario La Paz, Instituto de Investigación Hospital Universitario La Paz (IdiPAZ), Madrid, Spain
2 shared publications - Constantino Fondevila
Hepatopancreatobiliary Surgery & Transplantation, General & Digestive Surgery Service Hospital Universitario La Paz, Instituto de Investigación Hospital Universitario La Paz (IdiPAZ), Madrid, Spain
2 shared publications - Jordi Vengohechea
General & Digestive Surgery Service, Hospital Universitario La Paz, Madrid, Spain; Instituto de Investigación La Paz (IdiPAZ), Madrid, Spain; Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd), Madrid, Spain; Department of Surgery and Surgical Specializations, University of Barcelona, Barcelona, Spain
2 shared publications
Latest Publications
- Open Access
- 5 March 2026
- Published by Elsevier in JHEP Reports
- Vol. 8 (7) , 101811
Hemodiafiltration improves performance of 24 hour ex situ normothermic liver machine perfusion
- 5 March 2026
- Published by Elsevier in JHEP Reports
- Vol. 8 (7) , 101811
Open AccessHemodiafiltration improves performance of 24 hour ex situ normothermic liver machine perfusion
- Open Access
New Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
Background/Objectives: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims to evaluate, for the first time, the feasibility, safety and performance of microwave-based colonoscopy for diagnosis of polyps in real-time explorations in humans. Methods: This was a single-center, prospective, observational study. Patients referred for diagnostic colonoscopy were explored with a device with microwave antennas which was attached to the tip of a standard colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for the detection of polyps. Secondary outcomes were the following: patients’ subjective feedback, procedural time and perception of difficulty according to the endoscopist. Results: Fifteen patients were enrolled. Cecal intubation rate was 100%, with a mean time of 12.7 ± 4.9 min (range 4–22). Use of the device did not affect the endoscopic image, and polypectomy was successfully performed in all cases. In on scale from zero (not difficult) to four (very difficult), the maneuverability during the insertion was considered ≤2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) reported no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential to detect polyps in real colonoscopies.
Open AccessNew Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
Background/Objectives: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims to evaluate, for the first time, the feasibility, safety and performance of microwave-based colonoscopy for diagnosis of polyps in real-time explorations in humans. Methods: This was a single-center, prospective, observational study. Patients referred for diagnostic colonoscopy were explored with a device with microwave antennas which was attached to the tip of a standard colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for the detection of polyps. Secondary outcomes were the following: patients’ subjective feedback, procedural time and perception of difficulty according to the endoscopist. Results: Fifteen patients were enrolled. Cecal intubation rate was 100%, with a mean time of 12.7 ± 4.9 min (range 4–22). Use of the device did not affect the endoscopic image, and polypectomy was successfully performed in all cases. In on scale from zero (not difficult) to four (very difficult), the maneuverability during the insertion was considered ≤2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) reported no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential to detect polyps in real colonoscopies.
- Open Access
- 25 February 2025
- Published by MDPI AG in Preprints.org
New Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
Background/Objectives: Microwave imaging can obtain anatomical and functional images of the colon and has demonstrated to detect polyps based on their dielectric properties. This study aims to evaluate the feasibility, safety and performance of micro-wave-based colonoscopy for diagnosis of polyps in humans. Methods: single-center, prospective, observational study. Patients referred for elective outpatient diagnostic co-lonoscopy were included. A device provided with microwave antennas was attached to the tip of a conventional colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for detection of polyps. Secondary outcomes were: patients’ subjective feedback, procedural time and perception of difficulty by the endoscopist. Results: 15 patients were enrolled. Cecal intubation rate was 100% with a mean time of 12.7±4.9 min (range 4-22). Use of the device did not affect the endoscopic image and polypectomy was successfully performed in all cases. In a scale from 0 (not difficult) to 4 (very difficult), the maneuverability during the insertion was considered < 2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) referred no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential of detecting polyps.
- 25 February 2025
- Published by MDPI AG in Preprints.org
Open AccessNew Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience
Background/Objectives: Microwave imaging can obtain anatomical and functional images of the colon and has demonstrated to detect polyps based on their dielectric properties. This study aims to evaluate the feasibility, safety and performance of micro-wave-based colonoscopy for diagnosis of polyps in humans. Methods: single-center, prospective, observational study. Patients referred for elective outpatient diagnostic co-lonoscopy were included. A device provided with microwave antennas was attached to the tip of a conventional colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for detection of polyps. Secondary outcomes were: patients’ subjective feedback, procedural time and perception of difficulty by the endoscopist. Results: 15 patients were enrolled. Cecal intubation rate was 100% with a mean time of 12.7±4.9 min (range 4-22). Use of the device did not affect the endoscopic image and polypectomy was successfully performed in all cases. In a scale from 0 (not difficult) to 4 (very difficult), the maneuverability during the insertion was considered < 2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) referred no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. Conclusions: microwave-based colonoscopy is safe and feasible and has the potential of detecting polyps.
- Open Access
Preclinical Evaluation of a Microwave-Based Accessory Device for Colonoscopy in an In Vivo Porcine Model with Colorectal Polyps
Background and Aims: Colonoscopy is currently the most effective way of detecting colorectal cancer and removing polyps, but it has some drawbacks and can miss up to 22% of polyps. Microwave imaging has the potential to provide a 360° view of the colon and addresses some of the limitations of conventional colonoscopy. This study evaluates the feasibility of a microwave-based colonoscopy in an in vivo porcine model. Methods: A prototype device with microwave antennas attached to a conventional endoscope was tested on four healthy pigs and three gene-targeted pigs with mutations in the adenomatous polyposis coli gene. The first four animals were used to evaluate safety and maneuverability and compatibility with endoscopic tools. The ability to detect polyps was tested in a series of three gene-targeted pigs. Results: the microwave-based device did not affect endoscopic vision or cause any adverse events such as deep mural injuries. The microwave system was stable during the procedures, and the detection algorithm showed a maximum detection signal for adenomas compared with healthy mucosa. Conclusions: Microwave-based colonoscopy is feasible and safe in a preclinical model, and it has the potential to improve polyp detection. Further investigations are required to assess the device’s efficacy in humans.
Open AccessPreclinical Evaluation of a Microwave-Based Accessory Device for Colonoscopy in an In Vivo Porcine Model with Colorectal Polyps
Background and Aims: Colonoscopy is currently the most effective way of detecting colorectal cancer and removing polyps, but it has some drawbacks and can miss up to 22% of polyps. Microwave imaging has the potential to provide a 360° view of the colon and addresses some of the limitations of conventional colonoscopy. This study evaluates the feasibility of a microwave-based colonoscopy in an in vivo porcine model. Methods: A prototype device with microwave antennas attached to a conventional endoscope was tested on four healthy pigs and three gene-targeted pigs with mutations in the adenomatous polyposis coli gene. The first four animals were used to evaluate safety and maneuverability and compatibility with endoscopic tools. The ability to detect polyps was tested in a series of three gene-targeted pigs. Results: the microwave-based device did not affect endoscopic vision or cause any adverse events such as deep mural injuries. The microwave system was stable during the procedures, and the detection algorithm showed a maximum detection signal for adenomas compared with healthy mucosa. Conclusions: Microwave-based colonoscopy is feasible and safe in a preclinical model, and it has the potential to improve polyp detection. Further investigations are required to assess the device’s efficacy in humans.
- Open Access
Somatostatin Therapy Improves Stellate Cell Activation and Early Fibrogenesis in a Preclinical Model of Extended Major Hepatectomy
Liver resection treats primary and secondary liver tumors, though clinical applicability is limited by the remnant liver mass and quality. Herein, major hepatic resections were performed in pigs to define changes associated with sufficient and insufficient remnants and improve liver-specific outcomes with somatostatin therapy. Three experimental groups were performed: 75% hepatectomy (75H), 90% hepatectomy (90H), and 90% hepatectomy + somatostatin (90H + SST). Animals were followed for 24 h (N = 6) and 5 d (N = 6). After hepatectomy, portal pressure gradient was higher in 90H versus 75H and 90H + SST (8 (3–13) mmHg vs. 4 (2–6) mmHg and 4 (2–6) mmHg, respectively, p < 0.001). After 24 h, changes were observed in 90H associated with stellate cell activation and collapse of sinusoidal lumen. Collagen chain type 1 alpha 1 mRNA expression was higher, extracellular matrix width less, and percentage of collagen-staining areas greater at 24 h in 90H versus 75H and 90H + SST. After 5 d, remnant liver mass was higher in 75H and 90H + SST versus 90H, and Ki-67 immunostaining was higher in 90H + SST versus 75H and 90H. As well, more TUNEL-staining cells were observed in 90H versus 75H and 90H + SST at 5 d. Perioperative somatostatin modified portal pressure, injury, apoptosis, and stellate cell activation, stemming changes related to hepatic fibrogenesis seen in liver remnants not receiving treatment.
Open AccessSomatostatin Therapy Improves Stellate Cell Activation and Early Fibrogenesis in a Preclinical Model of Extended Major Hepatectomy
Liver resection treats primary and secondary liver tumors, though clinical applicability is limited by the remnant liver mass and quality. Herein, major hepatic resections were performed in pigs to define changes associated with sufficient and insufficient remnants and improve liver-specific outcomes with somatostatin therapy. Three experimental groups were performed: 75% hepatectomy (75H), 90% hepatectomy (90H), and 90% hepatectomy + somatostatin (90H + SST). Animals were followed for 24 h (N = 6) and 5 d (N = 6). After hepatectomy, portal pressure gradient was higher in 90H versus 75H and 90H + SST (8 (3–13) mmHg vs. 4 (2–6) mmHg and 4 (2–6) mmHg, respectively, p < 0.001). After 24 h, changes were observed in 90H associated with stellate cell activation and collapse of sinusoidal lumen. Collagen chain type 1 alpha 1 mRNA expression was higher, extracellular matrix width less, and percentage of collagen-staining areas greater at 24 h in 90H versus 75H and 90H + SST. After 5 d, remnant liver mass was higher in 75H and 90H + SST versus 90H, and Ki-67 immunostaining was higher in 90H + SST versus 75H and 90H. As well, more TUNEL-staining cells were observed in 90H versus 75H and 90H + SST at 5 d. Perioperative somatostatin modified portal pressure, injury, apoptosis, and stellate cell activation, stemming changes related to hepatic fibrogenesis seen in liver remnants not receiving treatment.