Dengwei Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dengwei Ding has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Cuifen Bai
Hebei Key Laboratory of Safety Monitoring and Mining Equipment, North China Institute of Science and Technology, Langfang 065201, China
1 shared publication - Junjun Liu
Maintenance Center, State Grid Chengdu Power Supply Company, Chengdu 610041, China
1 shared publication - Liang He
Tsinghua Sichuan Energy Internet Research Institute, Chengdu 610312, China
1 shared publication - Weidong Liu
School of Marine Science and Technology, Northwestern Polytechnical University, Xi’an 710072, China
1 shared publication - Ziwei Zhang
Sichuan Energy Internet Research Institute, Tsinghua University, Chengdu 610021, China
1 shared publication
Latest Publications
- Open Access
Transient Voltage UWB Online Monitoring System for Insulation Failure Analysis and Fault Location of GIL
Transient voltage generated in ultra-high voltage (UHV) transmission system has a severe impact on the insulation state of gas-insulated transmission lines (GIL). In order to monitor the transient voltage process occurring in UHV GIL during operation, this paper constructs a transient voltage ultra-wideband (UWB) online monitoring system based on capacitive voltage division. This system has been applied in an 1100 kilovolt (kV) GIL utility tunnel project. It can be used to analyze the characteristics of the recorded transient voltage waveforms for distinguishing different types of insulation failure. In this paper, through the case studies in time domain and time–frequency domain, the case of SF6 gap breakdown and that of post insulator flashover have differentiated characteristics in instantaneous frequency. Additionally, a case of secondary discharge is successfully estimated through the time–frequency distribution of the transient voltage. In order to find the malfunctioning chamber of GIL rapidly, a two-terminal TW-based fault location method based on this monitoring system is developed in this paper. The case study validates the locating accuracy which directly support for shortening the maintenance time of GIL.
Open AccessTransient Voltage UWB Online Monitoring System for Insulation Failure Analysis and Fault Location of GIL
Transient voltage generated in ultra-high voltage (UHV) transmission system has a severe impact on the insulation state of gas-insulated transmission lines (GIL). In order to monitor the transient voltage process occurring in UHV GIL during operation, this paper constructs a transient voltage ultra-wideband (UWB) online monitoring system based on capacitive voltage division. This system has been applied in an 1100 kilovolt (kV) GIL utility tunnel project. It can be used to analyze the characteristics of the recorded transient voltage waveforms for distinguishing different types of insulation failure. In this paper, through the case studies in time domain and time–frequency domain, the case of SF6 gap breakdown and that of post insulator flashover have differentiated characteristics in instantaneous frequency. Additionally, a case of secondary discharge is successfully estimated through the time–frequency distribution of the transient voltage. In order to find the malfunctioning chamber of GIL rapidly, a two-terminal TW-based fault location method based on this monitoring system is developed in this paper. The case study validates the locating accuracy which directly support for shortening the maintenance time of GIL.