Liang He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Liang He has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ziwei Zhang
Sichuan Energy Internet Research Institute, Tsinghua University, Chengdu 610021, China
2 shared publications - Cuifen Bai
Hebei Key Laboratory of Safety Monitoring and Mining Equipment, North China Institute of Science and Technology, Langfang 065201, China
1 shared publication - Dengwei Ding
Sichuan Energy Internet Research Institute, Tsinghua University, Chengdu 610213, China
1 shared publication - Dengwei Ding
Sichuan Energy Internet Research Institute, Tsinghua University, Chengdu, China
1 shared publication - Jie Yang
Engineering Training Center of CAVTC, Chengdu Aeronautic Polytechnic, Chengdu 610100, China
1 shared publication - Junjun Liu
Maintenance Center, State Grid Chengdu Power Supply Company, Chengdu 610041, China
1 shared publication
Latest Publications
- Open Access
Research on Mechanical Defect Detection and Diagnosis Method for GIS Equipment Based on Vibration Signal
Gas insulated switchgear equipment (GIS) is widely used in power system, and more attention has been paid to discharge defects than mechanical defects. However, since mechanical defects are a major cause of the failure in GIS, it is of great significance to carry out relevant research on mechanical defects. Detection and diagnosis methods of mechanical defects based on vibration signal are studied in this paper. Firstly, vibration mechanisms of GIS are analyzed. Due to structural differences between single phase insulated type GIS and three phase insulated type GIS, there are big differences in vibration mechanisms between the two types of GISs. Secondly, experimental research on mechanical defects is carried out based on a 110 kV GIS equipment and a self-developed vibration detection system; results show that mechanical defects can be diagnosed by analyzing signal amplitude, frequency spectrum and waveform distortion rate, and a large current is more beneficial for diagnosing mechanical defects. Lastly, field application has been carried out on 220 kV GIS equipment, and a poor contact defect is found, demonstrating that abnormal diagnosis can be realized by method proposed in this paper. Experimental research and field application demonstrate the feasibility and effectiveness of detection and diagnosis method for mechanical defects based on vibration signal and provide experience for subsequent engineering application.
Open AccessResearch on Mechanical Defect Detection and Diagnosis Method for GIS Equipment Based on Vibration Signal
Gas insulated switchgear equipment (GIS) is widely used in power system, and more attention has been paid to discharge defects than mechanical defects. However, since mechanical defects are a major cause of the failure in GIS, it is of great significance to carry out relevant research on mechanical defects. Detection and diagnosis methods of mechanical defects based on vibration signal are studied in this paper. Firstly, vibration mechanisms of GIS are analyzed. Due to structural differences between single phase insulated type GIS and three phase insulated type GIS, there are big differences in vibration mechanisms between the two types of GISs. Secondly, experimental research on mechanical defects is carried out based on a 110 kV GIS equipment and a self-developed vibration detection system; results show that mechanical defects can be diagnosed by analyzing signal amplitude, frequency spectrum and waveform distortion rate, and a large current is more beneficial for diagnosing mechanical defects. Lastly, field application has been carried out on 220 kV GIS equipment, and a poor contact defect is found, demonstrating that abnormal diagnosis can be realized by method proposed in this paper. Experimental research and field application demonstrate the feasibility and effectiveness of detection and diagnosis method for mechanical defects based on vibration signal and provide experience for subsequent engineering application.
- Open Access
Transient Voltage UWB Online Monitoring System for Insulation Failure Analysis and Fault Location of GIL
Transient voltage generated in ultra-high voltage (UHV) transmission system has a severe impact on the insulation state of gas-insulated transmission lines (GIL). In order to monitor the transient voltage process occurring in UHV GIL during operation, this paper constructs a transient voltage ultra-wideband (UWB) online monitoring system based on capacitive voltage division. This system has been applied in an 1100 kilovolt (kV) GIL utility tunnel project. It can be used to analyze the characteristics of the recorded transient voltage waveforms for distinguishing different types of insulation failure. In this paper, through the case studies in time domain and time–frequency domain, the case of SF6 gap breakdown and that of post insulator flashover have differentiated characteristics in instantaneous frequency. Additionally, a case of secondary discharge is successfully estimated through the time–frequency distribution of the transient voltage. In order to find the malfunctioning chamber of GIL rapidly, a two-terminal TW-based fault location method based on this monitoring system is developed in this paper. The case study validates the locating accuracy which directly support for shortening the maintenance time of GIL.
Open AccessTransient Voltage UWB Online Monitoring System for Insulation Failure Analysis and Fault Location of GIL
Transient voltage generated in ultra-high voltage (UHV) transmission system has a severe impact on the insulation state of gas-insulated transmission lines (GIL). In order to monitor the transient voltage process occurring in UHV GIL during operation, this paper constructs a transient voltage ultra-wideband (UWB) online monitoring system based on capacitive voltage division. This system has been applied in an 1100 kilovolt (kV) GIL utility tunnel project. It can be used to analyze the characteristics of the recorded transient voltage waveforms for distinguishing different types of insulation failure. In this paper, through the case studies in time domain and time–frequency domain, the case of SF6 gap breakdown and that of post insulator flashover have differentiated characteristics in instantaneous frequency. Additionally, a case of secondary discharge is successfully estimated through the time–frequency distribution of the transient voltage. In order to find the malfunctioning chamber of GIL rapidly, a two-terminal TW-based fault location method based on this monitoring system is developed in this paper. The case study validates the locating accuracy which directly support for shortening the maintenance time of GIL.