Makoto Matsueda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Makoto Matsueda has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Motoki Terashima
Collaborative Laboratories for Advanced Decommissioning Science, Japan Atomic Energy Agency, Fukushima, Japan
3 shared publications- Yoshitaka Takagai
Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University, 1 Kanayagawa, Fukushima 960-1296, Japan
3 shared publications - Jun Koarashi
Japan Atomic Energy Agency
2 shared publications - Kayo Yanagisawa
JAEA
2 shared publications - Kazuma Koarai
Japan Atomic Energy Agency
2 shared publications Kenso Fujiwara
Japan Atomic Energy Agency Collaborative Laboratories for Advanced Decommissioning Science 10-2, Fukasaku, Miharu-machi, Tamura-gun, Fukushima 963-7700, Japan
2 shared publications
Latest Publications
- Open Access
- 13 September 2026
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (12) , 1371-1375
First quantification of 90 Sr in fuel debris from the Fukushima-Daiichi Nuclear Power Plant: towards rapid ICP-MS analysis
- 13 September 2026
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (12) , 1371-1375
Open AccessFirst quantification of 90 Sr in fuel debris from the Fukushima-Daiichi Nuclear Power Plant: towards rapid ICP-MS analysis
- Open Access
- 27 May 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Progressive release of long-stored carbon from tropical peatland disturbances
Tropical peatlands are globally important, millennia-old carbon sinks, yet unprecedented human-driven degradation is triggering alarming carbon emissions. Comprehensive quantification of carbon dynamics across the disturbance sequence—from peat swamp forests to drained and fire-impacted peatlands—remains a critical knowledge gap. Here we show that over 18 years (1996–2014), drainage and subsequent peat fires released approximately 30–41 kg C m −2 from peatlands in Central Kalimantan, Indonesia, using radiocarbon dating of peat profiles and groundwater dissolved organic carbon. Drainage contributed 5–11 kg C m −2 , primarily from centuries- to millennium-old, previously waterlogged peat. Fires released 23–32 kg C m −2 from peat accumulated over the past 3,000 years, initiating progressive oxidative decomposition of older peat. Extrapolation to Indonesia’s disturbed peatlands suggests a release of 0.81–3.70 Gt C between 1996 and 2014, with ongoing decomposition releasing an additional 0.03–0.08 Gt C annually, accelerating the impact on the global carbon balance.
- 27 May 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessProgressive release of long-stored carbon from tropical peatland disturbances
Tropical peatlands are globally important, millennia-old carbon sinks, yet unprecedented human-driven degradation is triggering alarming carbon emissions. Comprehensive quantification of carbon dynamics across the disturbance sequence—from peat swamp forests to drained and fire-impacted peatlands—remains a critical knowledge gap. Here we show that over 18 years (1996–2014), drainage and subsequent peat fires released approximately 30–41 kg C m −2 from peatlands in Central Kalimantan, Indonesia, using radiocarbon dating of peat profiles and groundwater dissolved organic carbon. Drainage contributed 5–11 kg C m −2 , primarily from centuries- to millennium-old, previously waterlogged peat. Fires released 23–32 kg C m −2 from peat accumulated over the past 3,000 years, initiating progressive oxidative decomposition of older peat. Extrapolation to Indonesia’s disturbed peatlands suggests a release of 0.81–3.70 Gt C between 1996 and 2014, with ongoing decomposition releasing an additional 0.03–0.08 Gt C annually, accelerating the impact on the global carbon balance.
- 22 June 2024
- Published by Elsevier in Environmental Pollution
- Vol. 357, 124427
Uncovering the characteristics of plastic-associated biofilm from the inland river system of Mongolia
- 22 June 2024
- Published by Elsevier in Environmental Pollution
- Vol. 357, 124427
Uncovering the characteristics of plastic-associated biofilm from the inland river system of Mongolia
- 15 August 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (18) , 4291-4299
Quantitative imaging of trace elements in solid samples by online isotope dilution laser ablation-inductively coupled plasma-mass spectrometry
For quantitative visualization of trace elements, an online isotope dilution (ID) laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) method capable of accurately correcting the detection amount of targets is presented. Two aerosols from an ablated sample and a nebulized isotopically enriched spike solution were mixed online using a dual-port spray chamber. In this paper, transmission efficiency (TE) of each of the two gas streams to the ICP-MS detector is revealed, and the quantification values were corrected by including the ratio of TEs in the calculation of the online ID method. To verify the developed method, Fe and Sr as model elements in five certified reference materials (CRMs, glass: SRM 610, 612, 614, alloy: SS-356, -383) were quantified without the use of matrix-matched CRMs. The resultant values agreed with the certified values of CRMs in the range of 92.7–104.7% and 92.8–109.0% for Fe and Sr, respectively. The LODs (3σ) were 0.54 and 0.17 μg g−1 for Fe and Sr, respectively. In addition, the applicability of this method to quantitative imaging of unknown solid samples was demonstrated for actual biological hard tissues (a mouse incisor, human primary tooth, and fish otolith) using the result of shot-analysis. The results were consistent with the reported concentration range obtained by wet chemical analysis.
- 15 August 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (18) , 4291-4299
Quantitative imaging of trace elements in solid samples by online isotope dilution laser ablation-inductively coupled plasma-mass spectrometry
For quantitative visualization of trace elements, an online isotope dilution (ID) laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) method capable of accurately correcting the detection amount of targets is presented. Two aerosols from an ablated sample and a nebulized isotopically enriched spike solution were mixed online using a dual-port spray chamber. In this paper, transmission efficiency (TE) of each of the two gas streams to the ICP-MS detector is revealed, and the quantification values were corrected by including the ratio of TEs in the calculation of the online ID method. To verify the developed method, Fe and Sr as model elements in five certified reference materials (CRMs, glass: SRM 610, 612, 614, alloy: SS-356, -383) were quantified without the use of matrix-matched CRMs. The resultant values agreed with the certified values of CRMs in the range of 92.7–104.7% and 92.8–109.0% for Fe and Sr, respectively. The LODs (3σ) were 0.54 and 0.17 μg g−1 for Fe and Sr, respectively. In addition, the applicability of this method to quantitative imaging of unknown solid samples was demonstrated for actual biological hard tissues (a mouse incisor, human primary tooth, and fish otolith) using the result of shot-analysis. The results were consistent with the reported concentration range obtained by wet chemical analysis.
- 13 September 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (11) , 1371-1376
Mass-spectrometric determination of iodine-129 using O2–CO2 mixed-gas reaction in inductively coupled plasma tandem quadrupole mass spectrometry
This paper presents a mass-spectrometric method for determining the radionuclide iodine-129 (129I) from the significant amount of interference in inductively coupled plasma tandem quadrupole mass spectrometry (ICP–MS/MS) using a dynamic reaction cell passing a mixture gas of O2 and CO2. Thus far, mass spectrometry analysis of trace amounts of 129I has been hampered by the presence of xenon-129 (129Xe) and the formation of polyatomic ions from excess amounts of stable isotope 127I. In this study, flowing a mixture gas of O2 and CO2 into the dynamic reaction cell (Q2) successfully removed both 129Xe interference and polyatomic interference (127IH2) in the analysis of 129I in ICP–MS/MS. The resulting ratio of (background noise of m/z 129)/127I was 4.6 × 10–10 ± 3.3 × 10–10, which enables the analysis of 10 mBq/L of 129I in the presence of 100 mg/L of stable 127I without chemical separation. The detection limit of this method was 0.73 mBq/L (= 0.11 ng/L) with an APEX-Q sample inlet desolvation device. For demonstration purposes, spike and recovery analysis of rainwater was performed, and good agreement between the spiked and recovered amounts was achieved. Graphical abstract
- 13 September 2022
- Published by Springer Nature in Analytical Sciences
- Vol. 38 (11) , 1371-1376
Mass-spectrometric determination of iodine-129 using O2–CO2 mixed-gas reaction in inductively coupled plasma tandem quadrupole mass spectrometry
This paper presents a mass-spectrometric method for determining the radionuclide iodine-129 (129I) from the significant amount of interference in inductively coupled plasma tandem quadrupole mass spectrometry (ICP–MS/MS) using a dynamic reaction cell passing a mixture gas of O2 and CO2. Thus far, mass spectrometry analysis of trace amounts of 129I has been hampered by the presence of xenon-129 (129Xe) and the formation of polyatomic ions from excess amounts of stable isotope 127I. In this study, flowing a mixture gas of O2 and CO2 into the dynamic reaction cell (Q2) successfully removed both 129Xe interference and polyatomic interference (127IH2) in the analysis of 129I in ICP–MS/MS. The resulting ratio of (background noise of m/z 129)/127I was 4.6 × 10–10 ± 3.3 × 10–10, which enables the analysis of 10 mBq/L of 129I in the presence of 100 mg/L of stable 127I without chemical separation. The detection limit of this method was 0.73 mBq/L (= 0.11 ng/L) with an APEX-Q sample inlet desolvation device. For demonstration purposes, spike and recovery analysis of rainwater was performed, and good agreement between the spiked and recovered amounts was achieved. Graphical abstract
- 9 September 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 198 (13-15) , 1014-1018
PERFORMANCE EVALUATION OF COMMERCIAL SCINTILLATION COCKTAILS FOR LOW-LEVEL TRITIUM COUNTING BY HIGH-CAPACITY LIQUID SCINTILLATION COUNTER
Low-background liquid scintillation counter is one of the popular measuring instruments used to investigate tritium radioactivity in environmental media. These instruments require the liquid sample and organic solvent to be mixed for tritium measurement. In the European Union, the registration, evaluation, authorization and restriction of chemicals regulation was established to control the use of chemical substances of very high concern. It is important to find continuously available alternative reagents. In this paper, a performance evaluation was conducted using four scintillation cocktails according to Japanese conventional procedure; although one of them, Gold Star LT2, contains nonylphenol ethoxylate, it will continue to be available for research and development. From the evaluation results it was confirmed that Gold Star LT2 would be a satisfactory alternative scintillator, which is similar performance of Ultima Gold LLT.
- 9 September 2022
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 198 (13-15) , 1014-1018
PERFORMANCE EVALUATION OF COMMERCIAL SCINTILLATION COCKTAILS FOR LOW-LEVEL TRITIUM COUNTING BY HIGH-CAPACITY LIQUID SCINTILLATION COUNTER
Low-background liquid scintillation counter is one of the popular measuring instruments used to investigate tritium radioactivity in environmental media. These instruments require the liquid sample and organic solvent to be mixed for tritium measurement. In the European Union, the registration, evaluation, authorization and restriction of chemicals regulation was established to control the use of chemical substances of very high concern. It is important to find continuously available alternative reagents. In this paper, a performance evaluation was conducted using four scintillation cocktails according to Japanese conventional procedure; although one of them, Gold Star LT2, contains nonylphenol ethoxylate, it will continue to be available for research and development. From the evaluation results it was confirmed that Gold Star LT2 would be a satisfactory alternative scintillator, which is similar performance of Ultima Gold LLT.
- Open Access
- 16 July 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6 (29) , 19281-19290
Online Solid-Phase Extraction–Inductively Coupled Plasma–Quadrupole Mass Spectrometry with Oxygen Dynamic Reaction for Quantification of Technetium-99
Quantification of pg/L levels (i.e., 0.6 mBq/L) of radioactive technetium-99 (99Tc) was achieved within 15 min in the presence of isobaric and polyatomic interference sources such as ruthenium-99 (99Ru) and molybdenum hydride (98Mo1H) at 3–11 orders of magnitude higher concentrations. Online solid-phase extraction–inductively coupled plasma–quadrupole mass spectrometry (ICP–QMS) with oxygen (O2) dynamic reaction cell (online SPE–ICP–MS–DRC) was shown to be a thorough automatic analytical system, circumventing the need for human handling. At three stepwise separations (SPE–DRC–Q mass filters), we showed that interference materials allowed the coexistence of abundance ratios of 1.5 × 10–13 and 1.1 × 10–5 for 99Tc/Mo and 99Tc/Ru, respectively. A classical mathematical correction using the natural isotope ratio of 99Ru/102Ru was used to calculate the residues of 99Ru. Using this optimized system, a detection limit (DL; 3σ) of 99Tc was 9.3 pg/L (= 5.9 mBq/L) for a 50 mL injection and sequential measurements were undertaken at a cycle of 24 min/sample. For the measurement of a lower concentration of 99Tc, an AG1-X8 anion-exchange column was used to study 20 L of seawater. Its DL was approximately 1000 times greater than that of previous methods (70.0 fg/L). Thus, this method withstands coexistences of 5.8 × 10–18 and 3.5 × 10–9 for 99Tc/Mo and 99Tc/Ru, respectively. Spike and recovery tests were conducted for environmental samples; the resulting values showed good agreement with the spike applied.
- 16 July 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6 (29) , 19281-19290
Open AccessOnline Solid-Phase Extraction–Inductively Coupled Plasma–Quadrupole Mass Spectrometry with Oxygen Dynamic Reaction for Quantification of Technetium-99
Quantification of pg/L levels (i.e., 0.6 mBq/L) of radioactive technetium-99 (99Tc) was achieved within 15 min in the presence of isobaric and polyatomic interference sources such as ruthenium-99 (99Ru) and molybdenum hydride (98Mo1H) at 3–11 orders of magnitude higher concentrations. Online solid-phase extraction–inductively coupled plasma–quadrupole mass spectrometry (ICP–QMS) with oxygen (O2) dynamic reaction cell (online SPE–ICP–MS–DRC) was shown to be a thorough automatic analytical system, circumventing the need for human handling. At three stepwise separations (SPE–DRC–Q mass filters), we showed that interference materials allowed the coexistence of abundance ratios of 1.5 × 10–13 and 1.1 × 10–5 for 99Tc/Mo and 99Tc/Ru, respectively. A classical mathematical correction using the natural isotope ratio of 99Ru/102Ru was used to calculate the residues of 99Ru. Using this optimized system, a detection limit (DL; 3σ) of 99Tc was 9.3 pg/L (= 5.9 mBq/L) for a 50 mL injection and sequential measurements were undertaken at a cycle of 24 min/sample. For the measurement of a lower concentration of 99Tc, an AG1-X8 anion-exchange column was used to study 20 L of seawater. Its DL was approximately 1000 times greater than that of previous methods (70.0 fg/L). Thus, this method withstands coexistences of 5.8 × 10–18 and 3.5 × 10–9 for 99Tc/Mo and 99Tc/Ru, respectively. Spike and recovery tests were conducted for environmental samples; the resulting values showed good agreement with the spike applied.