Kayo Yanagisawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kayo Yanagisawa has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Makoto Matsueda
JAEA Motooka Aza Ohtsuka
3 shared publications- Makoto Matsueda
Japan Atomic Energy Agency
2 shared publications Yoshihiro Kitatsuji
Japan Atomic Energy Agency
2 shared publications- Yoshitaka Takagai
Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University, 1 Kanayagawa, Fukushima 960-1296, Japan
2 shared publications Asako Sugita
Japan Atomic Energy Agency (JAEA)
1 shared publicationHideyuki Yasufuku
National Institute for Materials Science (NIMS) 1-1 Namiki
1 shared publication
Latest Publications
- Open Access
- 11 November 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
Phosphate-Functionalized Macroporous Cellulose Sponges for Uranium Recovery from Seawater
Cellulose-based adsorbents offer a sustainable platform for uranium recovery from seawater, but simple functionalization strategies that enable effective uranium capture under highly competitive marine conditions remain limited. Here, we report a post-phosphorylation strategy for introducing uranium-binding functionality into a preformed freeze-crosslinked carboxymethyl cellulose nanofiber (CMCF) sponge while retaining its interconnected macroporous architecture. Impregnation of the cellulose sponge with NH4H2PO4/urea followed by mild thermal treatment at 120 °C introduced up to 114 ± 18 mg P g–1 sponge. In seawater spiked with 10 mg L–1 U(VI), both nonphosphorylated and phosphorylated CMCF sponges showed similarly high U removal (>96%), largely obscuring the effect of phosphate functionalization. In contrast, a pronounced phosphate-dependent enhancement emerged under realistic seawater conditions: the nonphosphorylated sponge showed negligible U removal from natural seawater, whereas the post-phosphorylated P1-CMCF sponge achieved approximately 99% U removal within 24 h. SEM–EDX and XPS analyses further supported uranium accumulation at phosphate-rich cellulose interfaces and the involvement of phosphate-associated oxygen donor sites in U binding. The captured uranium was nearly quantitatively recovered using 0.1 mol L–1 NaHCO3, and adsorption performance was maintained over three adsorption–desorption cycles. These results demonstrate that simple post-phosphorylation of a preformed macroporous cellulose scaffold provides accessible uranium-binding interfaces while preserving the underlying transport architecture, offering a straightforward route to efficient and regenerable uranium recovery under chemically complex seawater conditions.
- 11 November 2026
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
Open AccessPhosphate-Functionalized Macroporous Cellulose Sponges for Uranium Recovery from Seawater
Cellulose-based adsorbents offer a sustainable platform for uranium recovery from seawater, but simple functionalization strategies that enable effective uranium capture under highly competitive marine conditions remain limited. Here, we report a post-phosphorylation strategy for introducing uranium-binding functionality into a preformed freeze-crosslinked carboxymethyl cellulose nanofiber (CMCF) sponge while retaining its interconnected macroporous architecture. Impregnation of the cellulose sponge with NH4H2PO4/urea followed by mild thermal treatment at 120 °C introduced up to 114 ± 18 mg P g–1 sponge. In seawater spiked with 10 mg L–1 U(VI), both nonphosphorylated and phosphorylated CMCF sponges showed similarly high U removal (>96%), largely obscuring the effect of phosphate functionalization. In contrast, a pronounced phosphate-dependent enhancement emerged under realistic seawater conditions: the nonphosphorylated sponge showed negligible U removal from natural seawater, whereas the post-phosphorylated P1-CMCF sponge achieved approximately 99% U removal within 24 h. SEM–EDX and XPS analyses further supported uranium accumulation at phosphate-rich cellulose interfaces and the involvement of phosphate-associated oxygen donor sites in U binding. The captured uranium was nearly quantitatively recovered using 0.1 mol L–1 NaHCO3, and adsorption performance was maintained over three adsorption–desorption cycles. These results demonstrate that simple post-phosphorylation of a preformed macroporous cellulose scaffold provides accessible uranium-binding interfaces while preserving the underlying transport architecture, offering a straightforward route to efficient and regenerable uranium recovery under chemically complex seawater conditions.
- Open Access
- 13 September 2026
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (12) , 1371-1375
First quantification of 90 Sr in fuel debris from the Fukushima-Daiichi Nuclear Power Plant: towards rapid ICP-MS analysis
- 13 September 2026
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 63 (12) , 1371-1375
Open AccessFirst quantification of 90 Sr in fuel debris from the Fukushima-Daiichi Nuclear Power Plant: towards rapid ICP-MS analysis
- 5 December 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (3) , 2091-2100
Automated flow electrolysis coupled with solid-phase extraction and ICP-MS/MS for rapid determination of neptunium-237
- 5 December 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (3) , 2091-2100
Automated flow electrolysis coupled with solid-phase extraction and ICP-MS/MS for rapid determination of neptunium-237
- 26 November 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (50) , 27980-27987
Isotope-Specific Quantitative Mapping of 90 Sr at Subfemtogram Levels via Online Isotope Dilution and Laser Ablation Inductively Coupled Plasma Tandem Mass Spectrometry
The quantitative mapping of radioisotopes in solids is crucial for understanding their microscale localization and migration. However, conventional radiometric and mass spectrometric techniques are only capable of bulk measurements without spatial resolution. Imaging plates provide spatial resolution, but they lack selectivity and cannot quantify radioisotopes that only emit beta radiation, such as 90Sr. Here, the first system for isotope-specific quantitative mapping of a pure beta emitter is demonstrated, integrating online isotope dilution (ID) with laser ablation inductively coupled plasma tandem mass spectrometry (LA-ICP-MS/MS). In a case study, ultratrace levels of 90Sr were accurately quantified without requiring matrix-matched certified reference materials (CRMs) for calibration or chemical separation. Severe isobaric/polyatomic interference (e.g., 90Zr+, 74Ge16O+, 89Y1H+, and 58Ni16O2+) was efficiently suppressed by O2 reaction in a dynamic reaction cell, which greatly improved the abundance sensitivity and allowed subfemtogram amounts of 90Sr to be quantitatively imaged. The background equivalent concentration (BEC) was 0.14 ng g-1 (equivalent to 7.0 × 102 Bq g-1) per data point, and the measurement time was within 1 s. Validation with CRMs and 90Sr samples confirmed accuracy of 88-116% relative to reference values. The proposed system is a versatile platform that can be applied to the practical mapping of radioactive solids, which has broad implications for nuclear waste disposal, environmental remediation, and radiation protection.
- 26 November 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (50) , 27980-27987
Isotope-Specific Quantitative Mapping of 90 Sr at Subfemtogram Levels via Online Isotope Dilution and Laser Ablation Inductively Coupled Plasma Tandem Mass Spectrometry
The quantitative mapping of radioisotopes in solids is crucial for understanding their microscale localization and migration. However, conventional radiometric and mass spectrometric techniques are only capable of bulk measurements without spatial resolution. Imaging plates provide spatial resolution, but they lack selectivity and cannot quantify radioisotopes that only emit beta radiation, such as 90Sr. Here, the first system for isotope-specific quantitative mapping of a pure beta emitter is demonstrated, integrating online isotope dilution (ID) with laser ablation inductively coupled plasma tandem mass spectrometry (LA-ICP-MS/MS). In a case study, ultratrace levels of 90Sr were accurately quantified without requiring matrix-matched certified reference materials (CRMs) for calibration or chemical separation. Severe isobaric/polyatomic interference (e.g., 90Zr+, 74Ge16O+, 89Y1H+, and 58Ni16O2+) was efficiently suppressed by O2 reaction in a dynamic reaction cell, which greatly improved the abundance sensitivity and allowed subfemtogram amounts of 90Sr to be quantitatively imaged. The background equivalent concentration (BEC) was 0.14 ng g-1 (equivalent to 7.0 × 102 Bq g-1) per data point, and the measurement time was within 1 s. Validation with CRMs and 90Sr samples confirmed accuracy of 88-116% relative to reference values. The proposed system is a versatile platform that can be applied to the practical mapping of radioactive solids, which has broad implications for nuclear waste disposal, environmental remediation, and radiation protection.
- 15 August 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (18) , 4291-4299
Quantitative imaging of trace elements in solid samples by online isotope dilution laser ablation-inductively coupled plasma-mass spectrometry
For quantitative visualization of trace elements, an online isotope dilution (ID) laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) method capable of accurately correcting the detection amount of targets is presented. Two aerosols from an ablated sample and a nebulized isotopically enriched spike solution were mixed online using a dual-port spray chamber. In this paper, transmission efficiency (TE) of each of the two gas streams to the ICP-MS detector is revealed, and the quantification values were corrected by including the ratio of TEs in the calculation of the online ID method. To verify the developed method, Fe and Sr as model elements in five certified reference materials (CRMs, glass: SRM 610, 612, 614, alloy: SS-356, -383) were quantified without the use of matrix-matched CRMs. The resultant values agreed with the certified values of CRMs in the range of 92.7–104.7% and 92.8–109.0% for Fe and Sr, respectively. The LODs (3σ) were 0.54 and 0.17 μg g−1 for Fe and Sr, respectively. In addition, the applicability of this method to quantitative imaging of unknown solid samples was demonstrated for actual biological hard tissues (a mouse incisor, human primary tooth, and fish otolith) using the result of shot-analysis. The results were consistent with the reported concentration range obtained by wet chemical analysis.
- 15 August 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (18) , 4291-4299
Quantitative imaging of trace elements in solid samples by online isotope dilution laser ablation-inductively coupled plasma-mass spectrometry
For quantitative visualization of trace elements, an online isotope dilution (ID) laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) method capable of accurately correcting the detection amount of targets is presented. Two aerosols from an ablated sample and a nebulized isotopically enriched spike solution were mixed online using a dual-port spray chamber. In this paper, transmission efficiency (TE) of each of the two gas streams to the ICP-MS detector is revealed, and the quantification values were corrected by including the ratio of TEs in the calculation of the online ID method. To verify the developed method, Fe and Sr as model elements in five certified reference materials (CRMs, glass: SRM 610, 612, 614, alloy: SS-356, -383) were quantified without the use of matrix-matched CRMs. The resultant values agreed with the certified values of CRMs in the range of 92.7–104.7% and 92.8–109.0% for Fe and Sr, respectively. The LODs (3σ) were 0.54 and 0.17 μg g−1 for Fe and Sr, respectively. In addition, the applicability of this method to quantitative imaging of unknown solid samples was demonstrated for actual biological hard tissues (a mouse incisor, human primary tooth, and fish otolith) using the result of shot-analysis. The results were consistent with the reported concentration range obtained by wet chemical analysis.