Johanna B. Fritzinger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johanna B. Fritzinger has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Cynthia A. Chestek
University of Michigan
2 shared publications - Elena della Valle
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
2 shared publications - Hillel J. Chiel
Case Western Reserve University
2 shared publications - James David Weiland
University of Michigan, Ann Arbor, USA
2 shared publications - Jeffrey P. Gill
Department of Biology, Case Western Reserve University, Cleveland, USA
2 shared publications - Julianna M. Richie
Department of Biomedical Engineering, University of Michigan
2 shared publications
Latest Publications
- Open Access
Representations of Pitch and Timbre of Instrument Sounds in the Inferior Colliculus
Purpose: The neural representation of pitch and timbre in complex sounds has previously been studied using synthetic, controlled stimuli to investigate underlying encoding mechanisms. These studies provide information about how single attributes of sound are represented in the inferior colliculus (IC), a critical hub of the auditory pathway where neurons are sensitive to stimulus periodicity and spectral shape, giving rise to representations of pitch and timbre, respectively. However, there is a gap in understanding how natural sounds with both pitch and timbre attributes, such as instrument sounds, are represented in the IC. Methods: In this study, extracellular recordings were made in the IC of awake rabbits in response to natural instrument stimuli varying in fundamental frequency (F0) to determine how instrument identity (timbre) and F0 (pitch) are represented in IC neurons. Results: Using decoding models for instrument identification, we found that instrument identity was redundantly encoded in a population of neurons with diverse rate and timing characteristics. F0 identification using decoding models trained on single-neuron rate responses was poor, but the population of rate responses contained enough information to identify F0 reliably. F0 information was also encoded in single-neuron temporal responses up to 196 Hz. F0 identification from a population of temporal responses was accurate up to approximately 900 Hz, but accuracy decreased at high F0s. For the task in which F0 was identified based on responses to both oboe and bassoon stimuli that had overlapping F0s, performance decreased compared to F0 identification based on responses to a single instrument. Conclusion: This result supports the hypothesis that pitch and timbre information are encoded jointly in the IC.
Open AccessRepresentations of Pitch and Timbre of Instrument Sounds in the Inferior Colliculus
Purpose: The neural representation of pitch and timbre in complex sounds has previously been studied using synthetic, controlled stimuli to investigate underlying encoding mechanisms. These studies provide information about how single attributes of sound are represented in the inferior colliculus (IC), a critical hub of the auditory pathway where neurons are sensitive to stimulus periodicity and spectral shape, giving rise to representations of pitch and timbre, respectively. However, there is a gap in understanding how natural sounds with both pitch and timbre attributes, such as instrument sounds, are represented in the IC. Methods: In this study, extracellular recordings were made in the IC of awake rabbits in response to natural instrument stimuli varying in fundamental frequency (F0) to determine how instrument identity (timbre) and F0 (pitch) are represented in IC neurons. Results: Using decoding models for instrument identification, we found that instrument identity was redundantly encoded in a population of neurons with diverse rate and timing characteristics. F0 identification using decoding models trained on single-neuron rate responses was poor, but the population of rate responses contained enough information to identify F0 reliably. F0 information was also encoded in single-neuron temporal responses up to 196 Hz. F0 identification from a population of temporal responses was accurate up to approximately 900 Hz, but accuracy decreased at high F0s. For the task in which F0 was identified based on responses to both oboe and bassoon stimuli that had overlapping F0s, performance decreased compared to F0 identification based on responses to a single instrument. Conclusion: This result supports the hypothesis that pitch and timbre information are encoded jointly in the IC.
- Open Access
- 21 April 2026
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 46 (21)
Timbre Encoding in the Inferior Colliculus
Timbre, or the quality of a sound, is a critical component in speech and music. One percept of timbre, brightness, is correlated with the spectral centroid and the spectral envelope of harmonic sounds. Little is known about how this aspect of timbre is encoded in the subcortical auditory system. We used physiological and computational modeling methods to investigate the representation of spectral peaks in a harmonic complex tone with a broad, triangular-shaped spectrum. Extracellular single-neuron recordings were made in the central nucleus of the inferior colliculus (IC) in awake, female Dutch-belted rabbits. A population response to the timbre stimulus was inferred by shifting the stimulus spectrum above and below the characteristic frequency of each neuron. Spectral peaks in the stimulus were encoded in peaks in the average-rate profiles of most neurons, and this representation was robust over a range of suprathreshold levels. Neural discrimination thresholds were also sufficient to describe human behavioral thresholds. Temporal responses were complex and often exhibited phase locking to the fundamental frequency and integer multiples of the fundamental frequency. Computational models that included neural fluctuation sensitivity and amplitude modulation-sensitive broadband inhibition captured the major trends in physiological results. These findings demonstrate that multiple mechanisms may influence robust spectral peak encoding in IC neurons.
- 21 April 2026
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 46 (21)
Open AccessTimbre Encoding in the Inferior Colliculus
Timbre, or the quality of a sound, is a critical component in speech and music. One percept of timbre, brightness, is correlated with the spectral centroid and the spectral envelope of harmonic sounds. Little is known about how this aspect of timbre is encoded in the subcortical auditory system. We used physiological and computational modeling methods to investigate the representation of spectral peaks in a harmonic complex tone with a broad, triangular-shaped spectrum. Extracellular single-neuron recordings were made in the central nucleus of the inferior colliculus (IC) in awake, female Dutch-belted rabbits. A population response to the timbre stimulus was inferred by shifting the stimulus spectrum above and below the characteristic frequency of each neuron. Spectral peaks in the stimulus were encoded in peaks in the average-rate profiles of most neurons, and this representation was robust over a range of suprathreshold levels. Neural discrimination thresholds were also sufficient to describe human behavioral thresholds. Temporal responses were complex and often exhibited phase locking to the fundamental frequency and integer multiples of the fundamental frequency. Computational models that included neural fluctuation sensitivity and amplitude modulation-sensitive broadband inhibition captured the major trends in physiological results. These findings demonstrate that multiple mechanisms may influence robust spectral peak encoding in IC neurons.
- Open Access
- 7 May 2025
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 45 (23)
Mechanisms of Tone-in-Noise Encoding in the Inferior Colliculus
Extracellular single-unit responses to tone-in-noise (TIN) stimuli were recorded in the inferior colliculus (IC) of awake female Dutch-belted rabbits. Stimuli consisted of wideband and narrowband TIN with on-and-off characteristic frequency tones. Neural responses to wideband TIN showed a pattern of rates that increased when the tone matched CF and decreased (with respect to noise-alone responses) when the tone was above or below CF. This result differed from narrowband TIN IC responses that depended on envelope fluctuations in the stimulus, consistent with neural-fluctuation sensitivity. The wideband TIN responses could be fit with a difference-of-Gaussians model that had narrow excitation and broad inhibition; responses to TIN could not be predicted by response maps or spectrotemporal receptive fields. Responses to diotic and contralateral presentations of wideband TIN did not differ due to presentation ear. A single-CF computational model of the IC could not predict responses to wideband TIN. However, adding local off-CF inhibitory inputs to an on-CF IC model improved accuracy. These results suggest that broad inhibition could explain encoding of wideband TIN at suprathreshold signal-to-noise ratios, whereas neural fluctuation sensitivity is more important for narrowband sounds.
- 7 May 2025
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 45 (23)
Open AccessMechanisms of Tone-in-Noise Encoding in the Inferior Colliculus
Extracellular single-unit responses to tone-in-noise (TIN) stimuli were recorded in the inferior colliculus (IC) of awake female Dutch-belted rabbits. Stimuli consisted of wideband and narrowband TIN with on-and-off characteristic frequency tones. Neural responses to wideband TIN showed a pattern of rates that increased when the tone matched CF and decreased (with respect to noise-alone responses) when the tone was above or below CF. This result differed from narrowband TIN IC responses that depended on envelope fluctuations in the stimulus, consistent with neural-fluctuation sensitivity. The wideband TIN responses could be fit with a difference-of-Gaussians model that had narrow excitation and broad inhibition; responses to TIN could not be predicted by response maps or spectrotemporal receptive fields. Responses to diotic and contralateral presentations of wideband TIN did not differ due to presentation ear. A single-CF computational model of the IC could not predict responses to wideband TIN. However, adding local off-CF inhibitory inputs to an on-CF IC model improved accuracy. These results suggest that broad inhibition could explain encoding of wideband TIN at suprathreshold signal-to-noise ratios, whereas neural fluctuation sensitivity is more important for narrowband sounds.
- Open Access
Mechanisms of Tone-in-Noise Encoding in the Inferior Colliculus
Extracellular single-unit responses to tone-in-noise (TIN) stimuli were recorded in the inferior colliculus (IC) of awake female Dutch-belted rabbits. Stimuli consisted of wideband and narrowband tone-in-noise (TIN) with on-and off-characteristic frequency tones. Neural responses to wideband TIN showed a pattern of rates that increased when the tone matched CF and decreased (with respect to noise-alone responses) when the tone was above or below CF. This result differed from narrowband TIN IC responses that depended on envelope fluctuations in the stimulus, consistent with neural-fluctuation sensitivity. The WB-TIN responses could be fit with a difference-of-gaussians model that had narrow excitation and broad inhibition; responses to TIN could not be predicted by response-maps or spectrotemporal receptive fields. Responses to diotic and contralateral presentations of WB-TIN did not differ due to presentation ear. A single-CF computational model of the IC could not predict responses to wideband TIN. However, adding local off-CF inhibitory inputs to an on-CF IC model improved accuracy. These results suggest that broad inhibition could explain encoding of wideband TIN at suprathreshold signal-to-noise ratios, whereas neural fluctuation sensitivity is more important for narrowband sounds. Significance Statement: Tone-in-noise (TIN) stimuli are used in physiology and psychophysics to explore sound perception. Physiological studies have primarily used tones at the characteristic frequency (CF) of a neuron. Here we present a systematic investigation of inferior colliculus (IC) neuron responses to on- and off-CF tones in wideband and narrowband noise, presented diotically or contralaterally, which revealed rate reductions not previously reported. Interestingly, responses to narrowband TIN can be explained by neural fluctuation sensitivity in the IC, but responses to wideband noise resulted in fundamentally different patterns of neural activity. Adding local off-CF inhibitory inputs to an established IC computational model accurately predicted responses to wideband TIN. This work highlights the role of broad inhibition in encoding complex sounds in the IC.
Open AccessMechanisms of Tone-in-Noise Encoding in the Inferior Colliculus
Extracellular single-unit responses to tone-in-noise (TIN) stimuli were recorded in the inferior colliculus (IC) of awake female Dutch-belted rabbits. Stimuli consisted of wideband and narrowband tone-in-noise (TIN) with on-and off-characteristic frequency tones. Neural responses to wideband TIN showed a pattern of rates that increased when the tone matched CF and decreased (with respect to noise-alone responses) when the tone was above or below CF. This result differed from narrowband TIN IC responses that depended on envelope fluctuations in the stimulus, consistent with neural-fluctuation sensitivity. The WB-TIN responses could be fit with a difference-of-gaussians model that had narrow excitation and broad inhibition; responses to TIN could not be predicted by response-maps or spectrotemporal receptive fields. Responses to diotic and contralateral presentations of WB-TIN did not differ due to presentation ear. A single-CF computational model of the IC could not predict responses to wideband TIN. However, adding local off-CF inhibitory inputs to an on-CF IC model improved accuracy. These results suggest that broad inhibition could explain encoding of wideband TIN at suprathreshold signal-to-noise ratios, whereas neural fluctuation sensitivity is more important for narrowband sounds. Significance Statement: Tone-in-noise (TIN) stimuli are used in physiology and psychophysics to explore sound perception. Physiological studies have primarily used tones at the characteristic frequency (CF) of a neuron. Here we present a systematic investigation of inferior colliculus (IC) neuron responses to on- and off-CF tones in wideband and narrowband noise, presented diotically or contralaterally, which revealed rate reductions not previously reported. Interestingly, responses to narrowband TIN can be explained by neural fluctuation sensitivity in the IC, but responses to wideband noise resulted in fundamentally different patterns of neural activity. Adding local off-CF inhibitory inputs to an established IC computational model accurately predicted responses to wideband TIN. This work highlights the role of broad inhibition in encoding complex sounds in the IC.
- Open Access
- 1 December 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (6) , 066033
Carbon fiber electrodes for intracellular recording and stimulation
Objective. To understand neural circuit dynamics, it is critical to manipulate and record many individual neurons. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems. Carbon fiber electrodes (CFEs) are 8 µm-diameter electrodes that can be assembled into dense arrays (pitches ⩾ 80 µm). They have good signal-to-noise ratios (SNRs) and provide stable extracellular recordings both acutely and chronically in neural tissue in vivo (e.g. rat motor cortex). The small fiber size suggests that arrays could be used for intracellular stimulation. Approach. We tested CFEs for intracellular stimulation using the large identified and electrically compact neurons of the marine mollusk Aplysia californica. Neuron cell bodies in Aplysia range from 30 µm to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. Main results. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular, as shown by simultaneous glass microelectrode recordings. CFEs coated with platinum-iridium could stimulate and had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. CFEs were less sensitive to mechanical perturbations than glass microelectrodes. Significance. The ability to do stable multi-channel recording while stimulating and recording intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.
- 1 December 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (6) , 066033
Open AccessCarbon fiber electrodes for intracellular recording and stimulation
Objective. To understand neural circuit dynamics, it is critical to manipulate and record many individual neurons. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems. Carbon fiber electrodes (CFEs) are 8 µm-diameter electrodes that can be assembled into dense arrays (pitches ⩾ 80 µm). They have good signal-to-noise ratios (SNRs) and provide stable extracellular recordings both acutely and chronically in neural tissue in vivo (e.g. rat motor cortex). The small fiber size suggests that arrays could be used for intracellular stimulation. Approach. We tested CFEs for intracellular stimulation using the large identified and electrically compact neurons of the marine mollusk Aplysia californica. Neuron cell bodies in Aplysia range from 30 µm to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. Main results. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular, as shown by simultaneous glass microelectrode recordings. CFEs coated with platinum-iridium could stimulate and had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. CFEs were less sensitive to mechanical perturbations than glass microelectrodes. Significance. The ability to do stable multi-channel recording while stimulating and recording intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.
- Open Access
Carbon Fiber Electrodes for Intracellular Recording and Stimulation
To understand neural circuit dynamics, it is critical to manipulate and record from many neurons, ideally at the single neuron level. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems, rather than on neuronal cultures. Carbon fiber electrodes (CFEs) are 8 micron-diameter electrodes that can be organized into arrays with pitches as low as 80 µm. They have been shown to have good signal-to-noise ratios (SNRs) and are capable of stable extracellular recording during both acute and chronic implantation in vivo in neural tissue such as rat motor cortex. Given the small fiber size, it is possible that they could be used in arrays for intracellular stimulation. We tested this using the large identified and electrically compact neurons of the marine mollusk Aplysia californica . The cell bodies of neurons in Aplysia range in size from 30 to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular as shown by recording from the same neuron using a glass microelectrode. Stimulating through CFEs coated with platinum-iridium had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. Thus, the stability for multi-channel recording and the ability to stimulate and record intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.
Open AccessCarbon Fiber Electrodes for Intracellular Recording and Stimulation
To understand neural circuit dynamics, it is critical to manipulate and record from many neurons, ideally at the single neuron level. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems, rather than on neuronal cultures. Carbon fiber electrodes (CFEs) are 8 micron-diameter electrodes that can be organized into arrays with pitches as low as 80 µm. They have been shown to have good signal-to-noise ratios (SNRs) and are capable of stable extracellular recording during both acute and chronic implantation in vivo in neural tissue such as rat motor cortex. Given the small fiber size, it is possible that they could be used in arrays for intracellular stimulation. We tested this using the large identified and electrically compact neurons of the marine mollusk Aplysia californica . The cell bodies of neurons in Aplysia range in size from 30 to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular as shown by recording from the same neuron using a glass microelectrode. Stimulating through CFEs coated with platinum-iridium had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. Thus, the stability for multi-channel recording and the ability to stimulate and record intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.