Elena della Valle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Elena della Valle has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Cynthia A. Chestek
University of Michigan
8 shared publications - James David Weiland
University of Michigan, Ann Arbor, USA
8 shared publications - Paras R. Patel
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
7 shared publications - Joseph G. Letner
University of Michigan
4 shared publications - Julianna M. Richie
Department of Biomedical Engineering, University of Michigan
4 shared publications - Dawen Cai
Department of Cell and Developmental Biology, University of Michigan
3 shared publications
Latest Publications
- Open Access
- 31 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 739-749
Fabrication and Validation of Sub-Cellular Carbon Fiber Electrodes
Multielectrode arrays for interfacing with neurons are of great interest for a wide range of medical applications. However, current electrodes cause damage over time. Ultra small carbon fibers help to address issues but controlling the electrode site geometry is difficult. Here we propose a methodology to create small, pointed fiber electrodes (SPFe). We compare the SPFe to previously made blowtorched fibers in characterization. The SPFe result in small site sizes $(105.4 \pm 20.8~\mu \text{m}^{{2}})$ with consistently sharp points (20.8 ± 7.64°). Additionally, these electrodes were able to record and/or stimulate neurons multiple animal models including rat cortex, mouse retina, Aplysia ganglia and octopus axial cord. In rat cortex, these electrodes recorded significantly higher peak amplitudes than the traditional blowtorched fibers. These SPFe may be applicable to a wide range of applications requiring a highly specific interface with individual neurons.
- 31 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 739-749
Open AccessFabrication and Validation of Sub-Cellular Carbon Fiber Electrodes
Multielectrode arrays for interfacing with neurons are of great interest for a wide range of medical applications. However, current electrodes cause damage over time. Ultra small carbon fibers help to address issues but controlling the electrode site geometry is difficult. Here we propose a methodology to create small, pointed fiber electrodes (SPFe). We compare the SPFe to previously made blowtorched fibers in characterization. The SPFe result in small site sizes $(105.4 \pm 20.8~\mu \text{m}^{{2}})$ with consistently sharp points (20.8 ± 7.64°). Additionally, these electrodes were able to record and/or stimulate neurons multiple animal models including rat cortex, mouse retina, Aplysia ganglia and octopus axial cord. In rat cortex, these electrodes recorded significantly higher peak amplitudes than the traditional blowtorched fibers. These SPFe may be applicable to a wide range of applications requiring a highly specific interface with individual neurons.
- 30 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59 (4) , 1110-1122
A Sub-mm3 Wireless Neural Stimulator IC for Visual Cortical Prosthesis With Optical Power Harvesting and 7.5-kb/s Data Telemetry
This article proposes StiMote, an untethered, free-floating and individually addressable stimulator mote designed for visual cortex stimulation, aimed at vision restoration. The system is optically powered by a custom photovoltaic (PV) layer. In addition, the photodiode (PD) layer captures the light modulation and forwards it to the optical receiver (ORX) including a tranimpedance amplifier. Translated instructions can assign a unique slot, up to 1024 available, to each mote within the time-division multiple access (TDMA) framework. In this work, we propose an automatic charge balance (CB) technique that monitors the injected charge to balance in bi-phasic switched-capacitor stimulation (SCS). The chip was confirmed fully functional when operated completely wirelessly using harvested light. Measurement results revealed a power consumption of 4.48 $\mu$ W with a 7.5-kb/s optical downlink data rate, corresponding to continuous updates at 2.5 Hz of 1024 motes to their individual 3-b stimulation intensity levels. The dc–dc converter, responsible for providing high voltage for stimulation, demonstrated 4.3-V output voltage when unloaded, with a maximum efficiency of 67.4%. The proposed CB circuit exhibited linear controllability of stimulation charge up to 16 nC, with a charge imbalance of less than 0.2 nC. Furthermore, in vitro testing confirmed the absence of chemical reactions at electrodes, and in vivo experiments conducted on live rats verified the effectiveness of the stimulation through StiMote.
- 30 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59 (4) , 1110-1122
A Sub-mm3 Wireless Neural Stimulator IC for Visual Cortical Prosthesis With Optical Power Harvesting and 7.5-kb/s Data Telemetry
This article proposes StiMote, an untethered, free-floating and individually addressable stimulator mote designed for visual cortex stimulation, aimed at vision restoration. The system is optically powered by a custom photovoltaic (PV) layer. In addition, the photodiode (PD) layer captures the light modulation and forwards it to the optical receiver (ORX) including a tranimpedance amplifier. Translated instructions can assign a unique slot, up to 1024 available, to each mote within the time-division multiple access (TDMA) framework. In this work, we propose an automatic charge balance (CB) technique that monitors the injected charge to balance in bi-phasic switched-capacitor stimulation (SCS). The chip was confirmed fully functional when operated completely wirelessly using harvested light. Measurement results revealed a power consumption of 4.48 $\mu$ W with a 7.5-kb/s optical downlink data rate, corresponding to continuous updates at 2.5 Hz of 1024 motes to their individual 3-b stimulation intensity levels. The dc–dc converter, responsible for providing high voltage for stimulation, demonstrated 4.3-V output voltage when unloaded, with a maximum efficiency of 67.4%. The proposed CB circuit exhibited linear controllability of stimulation charge up to 16 nC, with a charge imbalance of less than 0.2 nC. Furthermore, in vitro testing confirmed the absence of chemical reactions at electrodes, and in vivo experiments conducted on live rats verified the effectiveness of the stimulation through StiMote.
- Open Access
- 17 March 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (2) , 026019
Post-explant profiling of subcellular-scale carbon fiber intracortical electrodes and surrounding neurons enables modeling of recorded electrophysiology
Objective. Characterizing the relationship between neuron spiking and the signals that electrodes record is vital to defining the neural circuits driving brain function and informing clinical brain-machine interface design. However, high electrode biocompatibility and precisely localizing neurons around the electrodes are critical to defining this relationship. Approach. Here, we demonstrate consistent localization of the recording site tips of subcellular-scale (6.8 µm diameter) carbon fiber electrodes and the positions of surrounding neurons. We implanted male rats with carbon fiber electrode arrays for 6 or 12+ weeks targeting layer V motor cortex. After explanting the arrays, we immunostained the implant site and localized putative recording site tips with subcellular-cellular resolution. We then 3D segmented neuron somata within a 50 µm radius from implanted tips to measure neuron positions and health and compare to healthy cortex with symmetric stereotaxic coordinates. Main results. Immunostaining of astrocyte, microglia, and neuron markers confirmed that overall tissue health was indicative of high biocompatibility near the tips. While neurons near implanted carbon fibers were stretched, their number and distribution were similar to hypothetical fibers placed in healthy contralateral brain. Such similar neuron distributions suggest that these minimally invasive electrodes demonstrate the potential to sample naturalistic neural populations. This motivated the prediction of spikes produced by nearby neurons using a simple point source model fit using recorded electrophysiology and the mean positions of the nearest neurons observed in histology. Comparing spike amplitudes suggests that the radius at which single units can be distinguished from others is near the fourth closest neuron (30.7 ± 4.6 µm, X ˉ ± S) in layer V motor cortex. Significance. Collectively, these data and simulations provide the first direct evidence that neuron placement in the immediate vicinity of the recording site influences how many spike clusters can be reliably identified by spike sorting.
- 17 March 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (2) , 026019
Open AccessPost-explant profiling of subcellular-scale carbon fiber intracortical electrodes and surrounding neurons enables modeling of recorded electrophysiology
Objective. Characterizing the relationship between neuron spiking and the signals that electrodes record is vital to defining the neural circuits driving brain function and informing clinical brain-machine interface design. However, high electrode biocompatibility and precisely localizing neurons around the electrodes are critical to defining this relationship. Approach. Here, we demonstrate consistent localization of the recording site tips of subcellular-scale (6.8 µm diameter) carbon fiber electrodes and the positions of surrounding neurons. We implanted male rats with carbon fiber electrode arrays for 6 or 12+ weeks targeting layer V motor cortex. After explanting the arrays, we immunostained the implant site and localized putative recording site tips with subcellular-cellular resolution. We then 3D segmented neuron somata within a 50 µm radius from implanted tips to measure neuron positions and health and compare to healthy cortex with symmetric stereotaxic coordinates. Main results. Immunostaining of astrocyte, microglia, and neuron markers confirmed that overall tissue health was indicative of high biocompatibility near the tips. While neurons near implanted carbon fibers were stretched, their number and distribution were similar to hypothetical fibers placed in healthy contralateral brain. Such similar neuron distributions suggest that these minimally invasive electrodes demonstrate the potential to sample naturalistic neural populations. This motivated the prediction of spikes produced by nearby neurons using a simple point source model fit using recorded electrophysiology and the mean positions of the nearest neurons observed in histology. Comparing spike amplitudes suggests that the radius at which single units can be distinguished from others is near the fourth closest neuron (30.7 ± 4.6 µm, X ˉ ± S) in layer V motor cortex. Significance. Collectively, these data and simulations provide the first direct evidence that neuron placement in the immediate vicinity of the recording site influences how many spike clusters can be reliably identified by spike sorting.
- Open Access
Profiling neurons surrounding subcellular-scale carbon fiber electrode tracts enables modeling recorded signals
Summary: Characterizing the relationship between neuron spiking and the signals electrodes record is vital to defining the neural circuits driving brain function and informing computational modeling. However, electrode biocompatibility and precisely localizing neurons around the electrodes are critical to defining this relationship. Here, we show the ability to localize post-explant recording tips of subcellular-scale carbon fiber electrodes and surrounding neurons. Immunostaining of astrocyte, microglia, and neuron markers confirmed improved tissue health. While neurons near implants were stretched, their number and distribution were similar to control, suggesting that these minimally invasive electrodes demonstrate the potential to sample naturalistic neural populations. This motivated prediction of the spikes produced by neurons nearest to the electrodes using a model fit with recorded electrophysiology. These simulations show the first direct evidence that neuron placement in the immediate vicinity of the recording site influences how many spike clusters can be reliably identified by spike sorting.
Open AccessProfiling neurons surrounding subcellular-scale carbon fiber electrode tracts enables modeling recorded signals
Summary: Characterizing the relationship between neuron spiking and the signals electrodes record is vital to defining the neural circuits driving brain function and informing computational modeling. However, electrode biocompatibility and precisely localizing neurons around the electrodes are critical to defining this relationship. Here, we show the ability to localize post-explant recording tips of subcellular-scale carbon fiber electrodes and surrounding neurons. Immunostaining of astrocyte, microglia, and neuron markers confirmed improved tissue health. While neurons near implants were stretched, their number and distribution were similar to control, suggesting that these minimally invasive electrodes demonstrate the potential to sample naturalistic neural populations. This motivated prediction of the spikes produced by neurons nearest to the electrodes using a model fit with recorded electrophysiology. These simulations show the first direct evidence that neuron placement in the immediate vicinity of the recording site influences how many spike clusters can be reliably identified by spike sorting.
- Open Access
- 2 December 2021
- Published by Frontiers Media SA in Frontiers in Nanotechnology
- Vol. 3
Electrodeposited Platinum Iridium Enables Microstimulation With Carbon Fiber Electrodes
Ultrasmall microelectrode arrays have the potential to improve the spatial resolution of microstimulation. Carbon fiber (CF) microelectrodes with cross-sections of less than 8 μm have been demonstrated to penetrate cortical tissue and evoke minimal scarring in chronic implant tests. In this study, we investigate the stability and performance of neural stimulation electrodes comprised of electrodeposited platinum-iridium (PtIr) on carbon fibers. We conducted pulse testing and characterized charge injection in vitro and recorded voltage transients in vitro and in vivo. Standard electrochemical measurements (impedance spectroscopy and cyclic voltammetry) and visual inspection (scanning electron microscopy) were used to assess changes due to pulsing. Similar to other studies, the application of pulses caused a decrease in impedance and a reduction in voltage transients, but analysis of the impedance data suggests that these changes are due to surface modification and not permanent changes to the electrode. Comparison of scanning electron microscope images before and after pulse testing confirmed electrode stability.
- 2 December 2021
- Published by Frontiers Media SA in Frontiers in Nanotechnology
- Vol. 3
Open AccessElectrodeposited Platinum Iridium Enables Microstimulation With Carbon Fiber Electrodes
Ultrasmall microelectrode arrays have the potential to improve the spatial resolution of microstimulation. Carbon fiber (CF) microelectrodes with cross-sections of less than 8 μm have been demonstrated to penetrate cortical tissue and evoke minimal scarring in chronic implant tests. In this study, we investigate the stability and performance of neural stimulation electrodes comprised of electrodeposited platinum-iridium (PtIr) on carbon fibers. We conducted pulse testing and characterized charge injection in vitro and recorded voltage transients in vitro and in vivo. Standard electrochemical measurements (impedance spectroscopy and cyclic voltammetry) and visual inspection (scanning electron microscopy) were used to assess changes due to pulsing. Similar to other studies, the application of pulses caused a decrease in impedance and a reduction in voltage transients, but analysis of the impedance data suggests that these changes are due to surface modification and not permanent changes to the electrode. Comparison of scanning electron microscope images before and after pulse testing confirmed electrode stability.
- Open Access
- 1 December 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (6) , 066033
Carbon fiber electrodes for intracellular recording and stimulation
Objective. To understand neural circuit dynamics, it is critical to manipulate and record many individual neurons. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems. Carbon fiber electrodes (CFEs) are 8 µm-diameter electrodes that can be assembled into dense arrays (pitches ⩾ 80 µm). They have good signal-to-noise ratios (SNRs) and provide stable extracellular recordings both acutely and chronically in neural tissue in vivo (e.g. rat motor cortex). The small fiber size suggests that arrays could be used for intracellular stimulation. Approach. We tested CFEs for intracellular stimulation using the large identified and electrically compact neurons of the marine mollusk Aplysia californica. Neuron cell bodies in Aplysia range from 30 µm to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. Main results. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular, as shown by simultaneous glass microelectrode recordings. CFEs coated with platinum-iridium could stimulate and had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. CFEs were less sensitive to mechanical perturbations than glass microelectrodes. Significance. The ability to do stable multi-channel recording while stimulating and recording intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.
- 1 December 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (6) , 066033
Open AccessCarbon fiber electrodes for intracellular recording and stimulation
Objective. To understand neural circuit dynamics, it is critical to manipulate and record many individual neurons. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems. Carbon fiber electrodes (CFEs) are 8 µm-diameter electrodes that can be assembled into dense arrays (pitches ⩾ 80 µm). They have good signal-to-noise ratios (SNRs) and provide stable extracellular recordings both acutely and chronically in neural tissue in vivo (e.g. rat motor cortex). The small fiber size suggests that arrays could be used for intracellular stimulation. Approach. We tested CFEs for intracellular stimulation using the large identified and electrically compact neurons of the marine mollusk Aplysia californica. Neuron cell bodies in Aplysia range from 30 µm to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. Main results. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular, as shown by simultaneous glass microelectrode recordings. CFEs coated with platinum-iridium could stimulate and had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. CFEs were less sensitive to mechanical perturbations than glass microelectrodes. Significance. The ability to do stable multi-channel recording while stimulating and recording intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.
- 13 September 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 054001
Compositional and morphological properties of platinum-iridium electrodeposited on carbon fiber microelectrodes
Objective . Neural interfaces based on carbon fiber (CF) electrodes have demonstrated key positive attributes such as minimal foreign body response and mechanical strength to self-insert in brain tissue. However, carbon does not form a low impedance electrode interface with neural tissue. Electrodeposited platinum iridium (PtIr) has been used to improve electrode interface properties for metallic bioelectrodes. Approach . In this study, a PtIr electrodeposition process has been performed on CF microelectrode arrays to improve the interfacial properties of these arrays. We study the film morphology and composition as well as electrode durability and impedance. Results . A PtIr coating with a composition of 70% Pt, 30% Ir and a thickness of ∼400 nm was observed. Pt and Ir were evenly distributed within the film. Impedance was decreased by 89% @ 1 kHz. Accelerated soak testing in a heated ( T = 50 ∘ C) saline solution showed impedance increase (@ 1 kHz) of ∼12% after 36 days (89 equivalent) of soaking.
- 13 September 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 054001
Compositional and morphological properties of platinum-iridium electrodeposited on carbon fiber microelectrodes
Objective . Neural interfaces based on carbon fiber (CF) electrodes have demonstrated key positive attributes such as minimal foreign body response and mechanical strength to self-insert in brain tissue. However, carbon does not form a low impedance electrode interface with neural tissue. Electrodeposited platinum iridium (PtIr) has been used to improve electrode interface properties for metallic bioelectrodes. Approach . In this study, a PtIr electrodeposition process has been performed on CF microelectrode arrays to improve the interfacial properties of these arrays. We study the film morphology and composition as well as electrode durability and impedance. Results . A PtIr coating with a composition of 70% Pt, 30% Ir and a thickness of ∼400 nm was observed. Pt and Ir were evenly distributed within the film. Impedance was decreased by 89% @ 1 kHz. Accelerated soak testing in a heated ( T = 50 ∘ C) saline solution showed impedance increase (@ 1 kHz) of ∼12% after 36 days (89 equivalent) of soaking.
- Open Access
Carbon Fiber Electrodes for Intracellular Recording and Stimulation
To understand neural circuit dynamics, it is critical to manipulate and record from many neurons, ideally at the single neuron level. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems, rather than on neuronal cultures. Carbon fiber electrodes (CFEs) are 8 micron-diameter electrodes that can be organized into arrays with pitches as low as 80 µm. They have been shown to have good signal-to-noise ratios (SNRs) and are capable of stable extracellular recording during both acute and chronic implantation in vivo in neural tissue such as rat motor cortex. Given the small fiber size, it is possible that they could be used in arrays for intracellular stimulation. We tested this using the large identified and electrically compact neurons of the marine mollusk Aplysia californica . The cell bodies of neurons in Aplysia range in size from 30 to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular as shown by recording from the same neuron using a glass microelectrode. Stimulating through CFEs coated with platinum-iridium had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. Thus, the stability for multi-channel recording and the ability to stimulate and record intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.
Open AccessCarbon Fiber Electrodes for Intracellular Recording and Stimulation
To understand neural circuit dynamics, it is critical to manipulate and record from many neurons, ideally at the single neuron level. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems, rather than on neuronal cultures. Carbon fiber electrodes (CFEs) are 8 micron-diameter electrodes that can be organized into arrays with pitches as low as 80 µm. They have been shown to have good signal-to-noise ratios (SNRs) and are capable of stable extracellular recording during both acute and chronic implantation in vivo in neural tissue such as rat motor cortex. Given the small fiber size, it is possible that they could be used in arrays for intracellular stimulation. We tested this using the large identified and electrically compact neurons of the marine mollusk Aplysia californica . The cell bodies of neurons in Aplysia range in size from 30 to over 250 µm. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neuron’s cell body with both electrodes and connecting them to a DC coupled amplifier. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular as shown by recording from the same neuron using a glass microelectrode. Stimulating through CFEs coated with platinum-iridium had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. Thus, the stability for multi-channel recording and the ability to stimulate and record intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.
- 1 April 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (2) , 026037
Ultra-small carbon fiber electrode recording site optimization and improved in vivo chronic recording yield
Objective. Carbon fiber electrodes may enable better long-term brain implants, minimizing the tissue response commonly seen with silicon-based electrodes. The small diameter fiber may enable high-channel count brain-machine interfaces capable of reproducing dexterous movements. Past carbon fiber electrodes exhibited both high fidelity single unit recordings and a healthy neuronal population immediately adjacent to the recording site. However, the recording yield of our carbon fiber arrays chronically implanted in the brain typically hovered around 30%, for previously unknown reasons. In this paper we investigated fabrication process modifications aimed at increasing recording yield and longevity. Approach. We tested a new cutting method using a 532nm laser against traditional scissor methods for the creation of the electrode recording site. We verified the efficacy of improved recording sites with impedance measurements and in vivo array recording yield. Additionally, we tested potentially longer-lasting coating alternatives to PEDOT:pTS, including PtIr and oxygen plasma etching. New coatings were evaluated with accelerated soak testing and acute recording. Main results. We found that the laser created a consistent, sustainable 257 ± 13.8 µ m 2 electrode with low 1 kHz impedance (19 ± 4 kΩ with PEDOT:pTS) and low fiber-to-fiber variability. The PEDOT:pTS coated laser cut fibers were found to have high recording yield in acute (97% > 100 µ V pp , N = 34 fibers) and chronic (84% > 100 µ V pp , day 7; 71% > 100 µ V pp , day 63, N = 45 fibers) settings. The laser cut recording sites were good platforms for the PtIr coating and oxygen plasma etching, slowing the increase in 1 kHz impedance compared to PEDOT:pTS in an accelerated soak test. Significance. We have found that laser cut carbon fibers have a high recording yield that can be maintained for over two months in vivo and that alternative coatings perform better than PEDOT:pTS in accelerated aging tests. This work provides evidence to support carbon fiber arrays as a viable approach to high-density, clinically-feasible brain-machine interfaces.
- 1 April 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (2) , 026037
Ultra-small carbon fiber electrode recording site optimization and improved in vivo chronic recording yield
Objective. Carbon fiber electrodes may enable better long-term brain implants, minimizing the tissue response commonly seen with silicon-based electrodes. The small diameter fiber may enable high-channel count brain-machine interfaces capable of reproducing dexterous movements. Past carbon fiber electrodes exhibited both high fidelity single unit recordings and a healthy neuronal population immediately adjacent to the recording site. However, the recording yield of our carbon fiber arrays chronically implanted in the brain typically hovered around 30%, for previously unknown reasons. In this paper we investigated fabrication process modifications aimed at increasing recording yield and longevity. Approach. We tested a new cutting method using a 532nm laser against traditional scissor methods for the creation of the electrode recording site. We verified the efficacy of improved recording sites with impedance measurements and in vivo array recording yield. Additionally, we tested potentially longer-lasting coating alternatives to PEDOT:pTS, including PtIr and oxygen plasma etching. New coatings were evaluated with accelerated soak testing and acute recording. Main results. We found that the laser created a consistent, sustainable 257 ± 13.8 µ m 2 electrode with low 1 kHz impedance (19 ± 4 kΩ with PEDOT:pTS) and low fiber-to-fiber variability. The PEDOT:pTS coated laser cut fibers were found to have high recording yield in acute (97% > 100 µ V pp , N = 34 fibers) and chronic (84% > 100 µ V pp , day 7; 71% > 100 µ V pp , day 63, N = 45 fibers) settings. The laser cut recording sites were good platforms for the PtIr coating and oxygen plasma etching, slowing the increase in 1 kHz impedance compared to PEDOT:pTS in an accelerated soak test. Significance. We have found that laser cut carbon fibers have a high recording yield that can be maintained for over two months in vivo and that alternative coatings perform better than PEDOT:pTS in accelerated aging tests. This work provides evidence to support carbon fiber arrays as a viable approach to high-density, clinically-feasible brain-machine interfaces.
- 17 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 3 (1) , 9-16
A Versatile Magnetic Exposure System for In-Vitro, Ex-Vivo, and In-Vivo Experiments Finalized to Therapeutic Applications in the IF Range
The use of magnetic fields in therapeutic applications has considerably increased in recent years. In particular, many researchers have focused their attention on the use of low intensity magnetic fields, either alone or in combination with nanoparticles for drug delivery systems in nanomedicine. Laboratory experiments aimed at defining in vitro and in vivo outcomes are required, and reliable low intensity magnetic field exposure systems are needed. In the present study, we have performed the analytical and numerical design of a novel magnetic exposure system suitable for different biological applications, such as magnetoliposome drug delivery, ex vivo experiments on brain slices and in vivo studies. This system is be able to generate intensities of the order of mT in a frequency range from ELF to 20 kHz.
- 17 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 3 (1) , 9-16
A Versatile Magnetic Exposure System for In-Vitro, Ex-Vivo, and In-Vivo Experiments Finalized to Therapeutic Applications in the IF Range
The use of magnetic fields in therapeutic applications has considerably increased in recent years. In particular, many researchers have focused their attention on the use of low intensity magnetic fields, either alone or in combination with nanoparticles for drug delivery systems in nanomedicine. Laboratory experiments aimed at defining in vitro and in vivo outcomes are required, and reliable low intensity magnetic field exposure systems are needed. In the present study, we have performed the analytical and numerical design of a novel magnetic exposure system suitable for different biological applications, such as magnetoliposome drug delivery, ex vivo experiments on brain slices and in vivo studies. This system is be able to generate intensities of the order of mT in a frequency range from ELF to 20 kHz.