Zakaria Hussain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zakaria Hussain has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Saiful Zaimy Yahaya
Universiti Teknologi MARA Cawangan Pulau Pinang, Universiti in Permatang Pauh
6 shared publications - Rozan Boudville
Faculty of Electrical Engineering, Universiti Teknologi MARA, Malaysia
4 shared publications - Adi Izhar Che Ani
Universiti Teknologi MARA
3 shared publications - Emilia Noorsal
Universiti Teknologi MARA
3 shared publications - Khairul Azman Ahmad
Universiti Teknologi MARA
3 shared publications - Saharul Arof
Universiti Kuala Lumpur, Malaysian Spanish Institute
3 shared publications
Latest Publications
- Open Access
- 1 June 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 34 (3) , 1566-1581
Pole placement tuning of proportional integral derivative feedback controller for knee extension model
Functional electrical stimulation (FES) has shown potential in rehabilitative exercises for patients recovering from spinal cord injuries. In recent developments, conventional open-loop FES control techniques have evolved into closed-loop systems that employ feedback controllers for automation. However, closed-loop FES systems often face challenges due to muscle non-linear effects, such as fatigue, time delays, stiffness, and spasticity. Therefore, an accurate non-linear knee model is required during the design stage, and precise tuning of the feedback controller parameters is vital. A proportional– integral–derivative (PID) controller is commonly used as a feedback controller due to its simplicity and ease of implementation. However, most PID tuning methods are complex and time consuming. This paper investigates the viability of employing the pole placement technique for tuning a PID controller that regulates the non-linear knee extension model. The pole placement method aims to improve the control and adaptability of the PID controller in closed-loop FES systems, specifically by facilitating knee extension exercises. MATLAB Simulink was used to assess the effectiveness of this tuning approach. Results showed that the PID controller performed satisfactorily without non-linearities, but performance varied with the inclusion of specific non-linearities. The pole placement tuning method facilitated preliminary assessments of PID controller performance, preceding highly advanced optimization.
- 1 June 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 34 (3) , 1566-1581
Open AccessPole placement tuning of proportional integral derivative feedback controller for knee extension model
Functional electrical stimulation (FES) has shown potential in rehabilitative exercises for patients recovering from spinal cord injuries. In recent developments, conventional open-loop FES control techniques have evolved into closed-loop systems that employ feedback controllers for automation. However, closed-loop FES systems often face challenges due to muscle non-linear effects, such as fatigue, time delays, stiffness, and spasticity. Therefore, an accurate non-linear knee model is required during the design stage, and precise tuning of the feedback controller parameters is vital. A proportional– integral–derivative (PID) controller is commonly used as a feedback controller due to its simplicity and ease of implementation. However, most PID tuning methods are complex and time consuming. This paper investigates the viability of employing the pole placement technique for tuning a PID controller that regulates the non-linear knee extension model. The pole placement method aims to improve the control and adaptability of the PID controller in closed-loop FES systems, specifically by facilitating knee extension exercises. MATLAB Simulink was used to assess the effectiveness of this tuning approach. Results showed that the PID controller performed satisfactorily without non-linearities, but performance varied with the inclusion of specific non-linearities. The pole placement tuning method facilitated preliminary assessments of PID controller performance, preceding highly advanced optimization.
- Open Access
- 2 October 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 32 (3) , 199-216
Convolutional Neural Network for Transmission Line Fault Diagnosis Based on Signal Segmentation Approach
Convolutional Neural Network (CNN) is a Deep Learning algorithm that can take in an input signal, assign importance (learnable weights and biases) to various aspects of the signals and distinguish between them. The CNN algorithm trains a sample and obtains a CNN model capable of identifying different fault types to analyse transmission line faults. Fault analysis methods typically require feature extraction to synthesise the relevant and non-redundant information from the raw signals. However, these traditional methods are time-consuming and inconsistent, and they can produce biased results due to the reliance on human expertise and experience. Hence, this research focused on developing an intelligent system for fault detection in a three-phase transmission line using CNN. This research aims to develop a CNN model for automatic fault detection in a three-phase transmission line and evaluate the performance of the CNN model for analysing transmission line faults. The three-phase transmission line model was developed using MATLAB-Simulink. CNN was implemented to detect transmission line faults. The performance of CNN based on the signal segmentation approach was evaluated through three different types of data: ideal and noise-added signal data. The simulation result shows good performance accuracy of 99.11% for the ideal case, 99.36%, and 99.39% for 20 dB and 30 dB noise-added cases, respectively. The result shows that a higher noise value in transmission line fault current could increase the performance of CNN. In conclusion, the utilisation of CNN based on a signal segmentation approach for transmission line fault analysis has showed promising performance.
- 2 October 2023
- Published by Akademia Baru Publishing in Journal of Advanced Research in Applied Sciences and Engineering Technology
- Vol. 32 (3) , 199-216
Open AccessConvolutional Neural Network for Transmission Line Fault Diagnosis Based on Signal Segmentation Approach
Convolutional Neural Network (CNN) is a Deep Learning algorithm that can take in an input signal, assign importance (learnable weights and biases) to various aspects of the signals and distinguish between them. The CNN algorithm trains a sample and obtains a CNN model capable of identifying different fault types to analyse transmission line faults. Fault analysis methods typically require feature extraction to synthesise the relevant and non-redundant information from the raw signals. However, these traditional methods are time-consuming and inconsistent, and they can produce biased results due to the reliance on human expertise and experience. Hence, this research focused on developing an intelligent system for fault detection in a three-phase transmission line using CNN. This research aims to develop a CNN model for automatic fault detection in a three-phase transmission line and evaluate the performance of the CNN model for analysing transmission line faults. The three-phase transmission line model was developed using MATLAB-Simulink. CNN was implemented to detect transmission line faults. The performance of CNN based on the signal segmentation approach was evaluated through three different types of data: ideal and noise-added signal data. The simulation result shows good performance accuracy of 99.11% for the ideal case, 99.36%, and 99.39% for 20 dB and 30 dB noise-added cases, respectively. The result shows that a higher noise value in transmission line fault current could increase the performance of CNN. In conclusion, the utilisation of CNN based on a signal segmentation approach for transmission line fault analysis has showed promising performance.
- Open Access
Adaptive Sliding Mode Feedback Control Algorithm for a Nonlinear Knee Extension Model
Functional electrical stimulation (FES) has been widely used to treat spinal cord injury (SCI) patients. Many research studies employ a closed-loop FES system to monitor the stimulated muscle response and provide a precise amount of charge to the muscle. However, most closed-loop FES devices perform poorly and sometimes fail when muscle nonlinearity effects such as fatigue, time delay response, stiffness, spasticity, and subject change happen. The poor performance of the closed-loop FES device is mainly due to discrepancies in the feedback control algorithms. Most of the existing feedback control algorithms were not designed to adapt to new changes in patients with different nonlinearity effects, resulting in early muscle fatigue. Therefore, this research proposes an adaptive sliding mode (SM) feedback control algorithm that could adapt and fine-tune internal control settings in real-time according to the current subject’s nonlinear and time-varying muscle response during the rehabilitation (knee extension) exercise. The adaptive SM feedback controller consists mainly of system identification, direct torque control, and tunable feedback control settings. Employing the system identification unit in the feedback control algorithm enables real-time self-tuning and adjusting of the SM internal control settings according to the current patient’s condition. Initially, the patient’s knee trajectory response was identified by extracting meaningful information, which included time delay, rise time, overshoot, and steady-state error. The extracted information was used to fine-tune and update the internal SM control settings. Finally, the performance of the proposed adaptive SM feedback control algorithm in terms of system response time, stability, and rehabilitation time was analysed using a nonlinear knee model. The findings from the simulation results indicate that the adaptive SM feedback controller demonstrated the best control performance in accurately tracking the desired knee angle movement by having faster response times, smaller overshoots, and lower steady-state errors when compared with the conventional SM across four reference angle settings (20°, 30°, 40°, and 76°). The adaptive feedback SM controller was also observed to compensate for muscle nonlinearities, including fatigue, stiffness, spasticity, time delay, and other disturbances.
Open AccessAdaptive Sliding Mode Feedback Control Algorithm for a Nonlinear Knee Extension Model
Functional electrical stimulation (FES) has been widely used to treat spinal cord injury (SCI) patients. Many research studies employ a closed-loop FES system to monitor the stimulated muscle response and provide a precise amount of charge to the muscle. However, most closed-loop FES devices perform poorly and sometimes fail when muscle nonlinearity effects such as fatigue, time delay response, stiffness, spasticity, and subject change happen. The poor performance of the closed-loop FES device is mainly due to discrepancies in the feedback control algorithms. Most of the existing feedback control algorithms were not designed to adapt to new changes in patients with different nonlinearity effects, resulting in early muscle fatigue. Therefore, this research proposes an adaptive sliding mode (SM) feedback control algorithm that could adapt and fine-tune internal control settings in real-time according to the current subject’s nonlinear and time-varying muscle response during the rehabilitation (knee extension) exercise. The adaptive SM feedback controller consists mainly of system identification, direct torque control, and tunable feedback control settings. Employing the system identification unit in the feedback control algorithm enables real-time self-tuning and adjusting of the SM internal control settings according to the current patient’s condition. Initially, the patient’s knee trajectory response was identified by extracting meaningful information, which included time delay, rise time, overshoot, and steady-state error. The extracted information was used to fine-tune and update the internal SM control settings. Finally, the performance of the proposed adaptive SM feedback control algorithm in terms of system response time, stability, and rehabilitation time was analysed using a nonlinear knee model. The findings from the simulation results indicate that the adaptive SM feedback controller demonstrated the best control performance in accurately tracking the desired knee angle movement by having faster response times, smaller overshoots, and lower steady-state errors when compared with the conventional SM across four reference angle settings (20°, 30°, 40°, and 76°). The adaptive feedback SM controller was also observed to compensate for muscle nonlinearities, including fatigue, stiffness, spasticity, time delay, and other disturbances.
- 16 February 2022
- Published by Elsevier in Physiotherapy
- Vol. 114, e156
The effect of thoracic spine mobility exercises on chronic neck pain and disability in young adults: A preliminary exploratory study
- 16 February 2022
- Published by Elsevier in Physiotherapy
- Vol. 114, e156
The effect of thoracic spine mobility exercises on chronic neck pain and disability in young adults: A preliminary exploratory study
- Open Access
- 18 October 2021
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 39-45
Air cavity-based vibrational piezoelectric energy harvesters
Introduction. Known vibrational energy harvesting methods use a source of vibration to harvest electric energy. Piezoelectric material works as a sensing element converted mechanical energy (vibration) to electrical energy (electric field). The existing piezoelectric energy harvesting (PEHs) devices have low sensitivity, low energy conversion, and low bandwidth. The novelty of the proposed work consists of the design of PEH’s structure. Air cavity was implemented in the design where it is located under the sensing membrane to improve sensitivity. Another novelty is also consisting in the design structure where the flexural membrane was located at the top of electrodes. The third novelty is a new design structure of printed circuit board (PCB). The purpose of improvised design is to increase the stress in between the edges of PEH and increase energy conversion. With the new structure of PCB, it will work as a substrate that absorbs surrounding vibration energy and transfers it to sensing element. Methods. Three techniques were successfully designed in PEH and fabricated namely PEH A, PEH B, and PEH C were characterized by two experiments: load and vibration. The load experiment measured load pressure towards the PEH, whereas the vibration experiment measured stress towards the PEH. Results. PEH C has the highest induced voltage for a weight of 5.2 kg at the frequency of 50 Hz and the highest stored voltage for a period of 4 min. The three techniques applied in PEHs were showed improvement in transducer sensitivity and energy conversion. Practical value. A piezoelectric acoustic generator was used in the experiment to compare the performance of the designed PEH with available piezoelectric transducers in the market. The new flexible membrane worked as a sensing element was worked as a cantilever beam. PVDF was used as a sensing element due to the flexibility of the polymer material, which is expected to improve sensitivity and operating bandwidth.
- 18 October 2021
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 39-45
Open AccessAir cavity-based vibrational piezoelectric energy harvesters
Introduction. Known vibrational energy harvesting methods use a source of vibration to harvest electric energy. Piezoelectric material works as a sensing element converted mechanical energy (vibration) to electrical energy (electric field). The existing piezoelectric energy harvesting (PEHs) devices have low sensitivity, low energy conversion, and low bandwidth. The novelty of the proposed work consists of the design of PEH’s structure. Air cavity was implemented in the design where it is located under the sensing membrane to improve sensitivity. Another novelty is also consisting in the design structure where the flexural membrane was located at the top of electrodes. The third novelty is a new design structure of printed circuit board (PCB). The purpose of improvised design is to increase the stress in between the edges of PEH and increase energy conversion. With the new structure of PCB, it will work as a substrate that absorbs surrounding vibration energy and transfers it to sensing element. Methods. Three techniques were successfully designed in PEH and fabricated namely PEH A, PEH B, and PEH C were characterized by two experiments: load and vibration. The load experiment measured load pressure towards the PEH, whereas the vibration experiment measured stress towards the PEH. Results. PEH C has the highest induced voltage for a weight of 5.2 kg at the frequency of 50 Hz and the highest stored voltage for a period of 4 min. The three techniques applied in PEHs were showed improvement in transducer sensitivity and energy conversion. Practical value. A piezoelectric acoustic generator was used in the experiment to compare the performance of the designed PEH with available piezoelectric transducers in the market. The new flexible membrane worked as a sensing element was worked as a cantilever beam. PVDF was used as a sensing element due to the flexibility of the polymer material, which is expected to improve sensitivity and operating bandwidth.
- Open Access
- 16 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (8) , 968
Design of an FPGA-Based Fuzzy Feedback Controller for Closed-Loop FES in Knee Joint Model
Functional electrical stimulation (FES) device has been widely used by spinal cord injury (SCI) patients in their rehab exercises to restore motor function to their paralysed muscles. The major challenge of muscle contraction induced by FES is early muscle fatigue due to the open-loop stimulation strategy. To reduce the early muscle fatigue phenomenon, a closed-loop FES system is proposed to track the angle of the limb’s movement and provide an accurate amount of charge according to the desired reference angle. Among the existing feedback controllers, fuzzy logic controller (FLC) has been found to exhibit good control performance in handling complex non-linear systems without developing any complex mathematical model. Recently, there has been considerable interest in the implementation of FLC in hardware embedded systems. Therefore, in this paper, a digital fuzzy feedback controller (FFC) embedded in a field-programmable gate array (FPGA) board was proposed. The digital FFC mainly consists of an analog-to-digital converter (ADC) Data Acquisition and FLC sub-modules. The FFC was designed to monitor and control the progress of knee extension movement by regulating the stimulus pulse width duration to meet the target angle. The knee is expected to extend to a maximum reference angle setting (70°, 40° or 30°) from its normal position of 0° once the stimulus charge is applied to the muscle by the FES device. Initially, the FLC was modelled using MATLAB Simulink. Then, the FLC was hardcoded into digital logic using hardware description language (HDL) Verilog codes. Thereafter, the performance of the digital FLC was tested with a knee extension model using the HDL co-simulation technique in MATLAB Simulink. Finally, for real-time verification, the designed digital FFC was downloaded to the Intel FPGA (DE2-115) board. The digital FFC utilized only 4% of the total FPGA (Cyclone IV E) logic elements (LEs) and required 238 µs to regulate stimulus pulse width data, including 3 µs for the FLC computation. The high processing speed of the digital FFC enables the stimulus pulse width duration to be updated every stimulation cycle. Furthermore, the implemented digital FFC has demonstrated good control performance in accurately controlling the stimulus pulse width duration to reach the desired reference angle with very small overshoot (1.4°) and steady-state error (0.4°). These promising results are very useful for a real-world closed-loop FES application.
- 16 August 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (8) , 968
Open AccessDesign of an FPGA-Based Fuzzy Feedback Controller for Closed-Loop FES in Knee Joint Model
Functional electrical stimulation (FES) device has been widely used by spinal cord injury (SCI) patients in their rehab exercises to restore motor function to their paralysed muscles. The major challenge of muscle contraction induced by FES is early muscle fatigue due to the open-loop stimulation strategy. To reduce the early muscle fatigue phenomenon, a closed-loop FES system is proposed to track the angle of the limb’s movement and provide an accurate amount of charge according to the desired reference angle. Among the existing feedback controllers, fuzzy logic controller (FLC) has been found to exhibit good control performance in handling complex non-linear systems without developing any complex mathematical model. Recently, there has been considerable interest in the implementation of FLC in hardware embedded systems. Therefore, in this paper, a digital fuzzy feedback controller (FFC) embedded in a field-programmable gate array (FPGA) board was proposed. The digital FFC mainly consists of an analog-to-digital converter (ADC) Data Acquisition and FLC sub-modules. The FFC was designed to monitor and control the progress of knee extension movement by regulating the stimulus pulse width duration to meet the target angle. The knee is expected to extend to a maximum reference angle setting (70°, 40° or 30°) from its normal position of 0° once the stimulus charge is applied to the muscle by the FES device. Initially, the FLC was modelled using MATLAB Simulink. Then, the FLC was hardcoded into digital logic using hardware description language (HDL) Verilog codes. Thereafter, the performance of the digital FLC was tested with a knee extension model using the HDL co-simulation technique in MATLAB Simulink. Finally, for real-time verification, the designed digital FFC was downloaded to the Intel FPGA (DE2-115) board. The digital FFC utilized only 4% of the total FPGA (Cyclone IV E) logic elements (LEs) and required 238 µs to regulate stimulus pulse width data, including 3 µs for the FLC computation. The high processing speed of the digital FFC enables the stimulus pulse width duration to be updated every stimulation cycle. Furthermore, the implemented digital FFC has demonstrated good control performance in accurately controlling the stimulus pulse width duration to reach the desired reference angle with very small overshoot (1.4°) and steady-state error (0.4°). These promising results are very useful for a real-world closed-loop FES application.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 158-162
Design of Spurs Gear for High Backdrivability Powered Knee Orthosis for FES-Assisted Knee Swing
This paper described the investigation of the fracture of the gear designed for Powered knee orthosis rotation. Powered Knee Orthosis (PKO) is an assisting device that supports knee swing activities for disabled people. The main challenge in designing the gear includes the strength of the gear and bending stress of the gear tooth with selection of suitable material. This study highlights the appropriate specifications of the material and shape of the gear tooth that are suitable for PKO when the size and thickness of the gear are reduced. The contact stress and deformation analysis were analyzed by using Finite Element Method via Solidworks software. The simulated result of Von mises stress, deformation displacement of the design, and material selected demonstrate a safe specification to support the required intensity and rigidity of spurs gear for high backdrivability of PKO for knee swing activities.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 158-162
Design of Spurs Gear for High Backdrivability Powered Knee Orthosis for FES-Assisted Knee Swing
This paper described the investigation of the fracture of the gear designed for Powered knee orthosis rotation. Powered Knee Orthosis (PKO) is an assisting device that supports knee swing activities for disabled people. The main challenge in designing the gear includes the strength of the gear and bending stress of the gear tooth with selection of suitable material. This study highlights the appropriate specifications of the material and shape of the gear tooth that are suitable for PKO when the size and thickness of the gear are reduced. The contact stress and deformation analysis were analyzed by using Finite Element Method via Solidworks software. The simulated result of Von mises stress, deformation displacement of the design, and material selected demonstrate a safe specification to support the required intensity and rigidity of spurs gear for high backdrivability of PKO for knee swing activities.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 32-37
Implementation of quadcopter as a teaching tool to enhance engineering courses
This paper proposed a new teaching technique for engineering courses based on the implementation of drone technology. In some engineering related courses, teaching and learning are difficult due to very complex theoretical and technical explanation need to be digested by the non experienced students. In Malaysia, quadcopter is one of the technologies that become popular among young generation due to its capabilities and interesting features in various application such as aerial photography, aerial monitoring as well as aerial racing tournament. The use of quadcopter thought to be one of the best ways to introduce some engineering concept through a practical exposure followed by project based learning. The concept is able to enhance the understanding as students are exposed to a practical and visual approach used during the learning process. The outcomes shows that once the student gain confidence in building the drone unit, they are ready to explore more on the engineering disciplines through the process. Open source flight software, Mission Planner, is used to configure every components used in the development.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 32-37
Implementation of quadcopter as a teaching tool to enhance engineering courses
This paper proposed a new teaching technique for engineering courses based on the implementation of drone technology. In some engineering related courses, teaching and learning are difficult due to very complex theoretical and technical explanation need to be digested by the non experienced students. In Malaysia, quadcopter is one of the technologies that become popular among young generation due to its capabilities and interesting features in various application such as aerial photography, aerial monitoring as well as aerial racing tournament. The use of quadcopter thought to be one of the best ways to introduce some engineering concept through a practical exposure followed by project based learning. The concept is able to enhance the understanding as students are exposed to a practical and visual approach used during the learning process. The outcomes shows that once the student gain confidence in building the drone unit, they are ready to explore more on the engineering disciplines through the process. Open source flight software, Mission Planner, is used to configure every components used in the development.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 569-574
Design and development of an adjustable angle sensor based on rotary potentiometer for measuring finger flexion
In this paper, an adjustable angle sensor based on rotary potentiometer for measuring and monitoring finger flexion is proposed. Most of the current system is unadjustable, inaccurate, costly and hard to calibrate. The proposed system in this study consists of a rotary potentiometers and adjustable case, which makes it adjustable, compact and lightweight with the ability to produce a better measurement result. As the rotary potentiometer rotated due to the motion of the finger, the joint angles are calculated by measuring the change in resistance of the rotary potentiometer. The proposed system can widely be applied for the angle measurement systems at small and complex structure surface such as finger joint, which require to measure finger flexion for developing related device such as robotic hand control system, virtual reality or teleoperation systems. The experiment study shows that the proposed system is adjustable and has better accuracy, small repeatability error and more reliable compared to the popular flex sensor.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 569-574
Design and development of an adjustable angle sensor based on rotary potentiometer for measuring finger flexion
In this paper, an adjustable angle sensor based on rotary potentiometer for measuring and monitoring finger flexion is proposed. Most of the current system is unadjustable, inaccurate, costly and hard to calibrate. The proposed system in this study consists of a rotary potentiometers and adjustable case, which makes it adjustable, compact and lightweight with the ability to produce a better measurement result. As the rotary potentiometer rotated due to the motion of the finger, the joint angles are calculated by measuring the change in resistance of the rotary potentiometer. The proposed system can widely be applied for the angle measurement systems at small and complex structure surface such as finger joint, which require to measure finger flexion for developing related device such as robotic hand control system, virtual reality or teleoperation systems. The experiment study shows that the proposed system is adjustable and has better accuracy, small repeatability error and more reliable compared to the popular flex sensor.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 608-611
GA-tuned fuzzy logic control of knee-FES-ergometer for knee swinging exercise
Knee-FES-ergometer for knee swinging exercise is introduced as a hybrid exercise for restoration of function of the knee for stroke patients through the application of functional electrical stimulation (FES). The aim of the new knee-FES-ergometer is to provide high intensity knee swinging exercise. It is able to reduce required electrical stimulation and will able to elongate the exercise duration while avoiding early muscle fatigue. Fuzzy logic control (FLC) is used to control the knee trajectory for the purpose of smooth knee swinging exercise. However, conventional FLC rely on human experiences and trial and error for parameter identifications. In this work, a genetic algorithm (GA) is used to tune the FLC to maintain a smooth swinging exercise. The performance of the proposed GA tuned FLC is compared with a manually tuned FLC. Results shows that the GA tuned FLC offers encouragingly better performance.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 608-611
GA-tuned fuzzy logic control of knee-FES-ergometer for knee swinging exercise
Knee-FES-ergometer for knee swinging exercise is introduced as a hybrid exercise for restoration of function of the knee for stroke patients through the application of functional electrical stimulation (FES). The aim of the new knee-FES-ergometer is to provide high intensity knee swinging exercise. It is able to reduce required electrical stimulation and will able to elongate the exercise duration while avoiding early muscle fatigue. Fuzzy logic control (FLC) is used to control the knee trajectory for the purpose of smooth knee swinging exercise. However, conventional FLC rely on human experiences and trial and error for parameter identifications. In this work, a genetic algorithm (GA) is used to tune the FLC to maintain a smooth swinging exercise. The performance of the proposed GA tuned FLC is compared with a manually tuned FLC. Results shows that the GA tuned FLC offers encouragingly better performance.