Jonathan Outin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jonathan Outin has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Michel Ondarts
LOCIE Laboratory, UMR 5271, CNRS
4 shared publications - Evelyne Gonze
CNRS, LOCIE, UMR 5271, Université Savoie Mont-Blanc, 73376 Le Bourget-du-Lac, France
3 shared publications - Nolwenn Le Pierrès
Université Savoie Mont Blanc
2 shared publications - Anne-Laure Perrier
LOCIE Laboratory, Université Savoie Mont Blanc, CNRS UMR 5271, Savoie Technolac, 73376 Le Bourget du Lac, France
1 shared publication - Benoit Stutz
Université Savoie Mont Blanc, CNRS, LOCIE, Le Bourget du Lac, France
1 shared publication Delphine Bosch
Géosciences Montpellier Université de Montpellier Université des Antilles CNRS UMR 5243 Montpellier Cedex France
1 shared publication
Latest Publications
- Open Access
- 19 June 2025
- Published by American Geophysical Union (AGU) in Geochemistry, Geophysics, Geosystems
- Vol. 26 (6)
Tracking the Caribbean Magmatic Evolution: The British Virgin Islands as a Transition Between the Greater and Lesser Antilles Arcs
The British Virgin Islands (BVI) archipelago, located between the Greater Antilles and the Lesser Antilles, is a key location to study the geodynamic evolution of the Caribbean plate. Geochemistry of the studied samples reveals typical volcanic arc signatures, including a calc‐alkaline affinity, strong negative HFSE anomalies, and LILE enrichment. The ɛHf values are homogeneous, indicative of a MORB‐type mantle. Magmas were sourced from a homogeneous mantle wedge with less than 2% slab‐derived sediment inputs, dominated by aqueous fluids. A concomitant melt component has been detected in the Peter and Norman Islands. U‐Pb dating emphasizes an active magmatic period spanning over ca. 13 Myr (43–30 Ma), with a NE/SW decreasing age gradient. Thermobarometry data display a SW increasing emplacement depth from ∼6 to 13 km. Compared to the Greater and Lesser Antilles, this archipelago shows strong similarities with the extinct northern Lesser Antilles arc in terms of source and age. A geodynamical evolution model is proposed in which this archipelago represents a transition between the Greater and the Lesser Antilles arcs. The Oligocene cessation of magmatism (ca. 30 Ma) may coincide with a regionally documented lull in arc magmatic activity during which the Bahamas bank collided to the north. Paleomagnetic evidence of forearc sliver motion along the northeastern boundary of the Caribbean indicates a northward translation of the archipelago from a position above the Lesser Antilles subduction zone to its modern location along the highly oblique, strike‐slip‐dominated plate boundary, thus preventing the re‐establishment of arc magmatism in the eastern Caribbean.
- 19 June 2025
- Published by American Geophysical Union (AGU) in Geochemistry, Geophysics, Geosystems
- Vol. 26 (6)
Open AccessTracking the Caribbean Magmatic Evolution: The British Virgin Islands as a Transition Between the Greater and Lesser Antilles Arcs
The British Virgin Islands (BVI) archipelago, located between the Greater Antilles and the Lesser Antilles, is a key location to study the geodynamic evolution of the Caribbean plate. Geochemistry of the studied samples reveals typical volcanic arc signatures, including a calc‐alkaline affinity, strong negative HFSE anomalies, and LILE enrichment. The ɛHf values are homogeneous, indicative of a MORB‐type mantle. Magmas were sourced from a homogeneous mantle wedge with less than 2% slab‐derived sediment inputs, dominated by aqueous fluids. A concomitant melt component has been detected in the Peter and Norman Islands. U‐Pb dating emphasizes an active magmatic period spanning over ca. 13 Myr (43–30 Ma), with a NE/SW decreasing age gradient. Thermobarometry data display a SW increasing emplacement depth from ∼6 to 13 km. Compared to the Greater and Lesser Antilles, this archipelago shows strong similarities with the extinct northern Lesser Antilles arc in terms of source and age. A geodynamical evolution model is proposed in which this archipelago represents a transition between the Greater and the Lesser Antilles arcs. The Oligocene cessation of magmatism (ca. 30 Ma) may coincide with a regionally documented lull in arc magmatic activity during which the Bahamas bank collided to the north. Paleomagnetic evidence of forearc sliver motion along the northeastern boundary of the Caribbean indicates a northward translation of the archipelago from a position above the Lesser Antilles subduction zone to its modern location along the highly oblique, strike‐slip‐dominated plate boundary, thus preventing the re‐establishment of arc magmatism in the eastern Caribbean.
- Open Access
Permittivity Characterization of Conductive and Corrosive LiBr Water Solutions, Method Validation up to 9 GHz Using a Low-Cost SMA Probe
In this article, we present a method for extracting the complex permittivity of high-conductivity solutions up to 9 GHz. Microwave measurements were performed using a low-cost SMA connector, employed as an open-circuit coaxial probe, which was subsequently brought into contact with the liquids under characterization. Compared to state-of-the-art techniques, this method offers the advantage of good accuracy while remaining simple to implement with a low-cost sensor. The affordability of the sensor is crucial because the sensor must operate in a corrosive environment. The use of existing but expensive commercial solutions is prohibitive. Therefore, sensor replacement must be straightforward and inexpensive in case of damage. Two permittivity extraction methods were studied, both relying on a straightforward experimental approach and knowledge of the complex permittivity of reference liquids (deionized water, ethanol, methanol). The technique was initially validated on saline solutions (NaCl) known from the literature before being applied to aqueous lithium bromide (LiBr water) solutions. Eight LiBr water solutions, known to be highly corrosive, were measured for LiBr mass concentrations ranging from 1% to 54% and for conductivities up to 14 S/m. The high conductivity of these solutions brings challenges to extract the real part of the permittivity, which is underestimated by both methods. In contrast, the imaginary part exhibits consistent results with variations strongly correlated to the concentration. Notably, an inversion of the direction of variation was observed for mass concentration in LiBr exceeding 35% aligning with the conductivity curve.
Open AccessPermittivity Characterization of Conductive and Corrosive LiBr Water Solutions, Method Validation up to 9 GHz Using a Low-Cost SMA Probe
In this article, we present a method for extracting the complex permittivity of high-conductivity solutions up to 9 GHz. Microwave measurements were performed using a low-cost SMA connector, employed as an open-circuit coaxial probe, which was subsequently brought into contact with the liquids under characterization. Compared to state-of-the-art techniques, this method offers the advantage of good accuracy while remaining simple to implement with a low-cost sensor. The affordability of the sensor is crucial because the sensor must operate in a corrosive environment. The use of existing but expensive commercial solutions is prohibitive. Therefore, sensor replacement must be straightforward and inexpensive in case of damage. Two permittivity extraction methods were studied, both relying on a straightforward experimental approach and knowledge of the complex permittivity of reference liquids (deionized water, ethanol, methanol). The technique was initially validated on saline solutions (NaCl) known from the literature before being applied to aqueous lithium bromide (LiBr water) solutions. Eight LiBr water solutions, known to be highly corrosive, were measured for LiBr mass concentrations ranging from 1% to 54% and for conductivities up to 14 S/m. The high conductivity of these solutions brings challenges to extract the real part of the permittivity, which is underestimated by both methods. In contrast, the imaginary part exhibits consistent results with variations strongly correlated to the concentration. Notably, an inversion of the direction of variation was observed for mass concentration in LiBr exceeding 35% aligning with the conductivity curve.
- 1 January 2024
- Published by ISTE Group in Entropie : Thermodynamique – Énergie – Environnement – Économie
- Vol. 5 (5)
Stockage de chaleur thermochimique : expérimentation de différents matériaux composites innovants
Le stockage de chaleur par voie thermochimique est une solution d'avenir, car il permet un stockage sur des périodes aussi longues que désiré avec une densité énergétique élevée. Des sorbants (...)
- 1 January 2024
- Published by ISTE Group in Entropie : Thermodynamique – Énergie – Environnement – Économie
- Vol. 5 (5)
Stockage de chaleur thermochimique : expérimentation de différents matériaux composites innovants
Le stockage de chaleur par voie thermochimique est une solution d'avenir, car il permet un stockage sur des périodes aussi longues que désiré avec une densité énergétique élevée. Des sorbants (...)
- Open Access
- 11 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11789
Indoor Air Quality Campaign in an Occupied Low-Energy House with a High Level of Spatial and Temporal Discretization
Background and gaps. The topic of indoor air quality (IAQ) in low-energy buildings has received increasing interest over the past few years. Often based on two measurement points and on passive measurements over one week, IAQ studies are struggling to allow the calculation of pollutants exposure. Objectives. We would like to improve the evaluation of the health impacts, through measurements able to estimate the exposure of the occupants. Methodology. This article presents detailed IAQ measurements taken in an energy-efficient occupied house in France. Two campaigns were conducted in winter and spring. Total volatile organic compounds (TVOC), formaldehyde, the particle numbers and PM2.5, carbon dioxide (CO2), relative humidity (RH), temperature (T), ventilation airflows, and weather conditions were dynamically measured in several points. Laboratory and low-cost devices were used, and an inter-comparison was carried out for them. A survey was conducted to record all the daily activities of the inhabitants. IAQ performance indicators based on the different pollutants were calculated. Results. PM2.5 cumulative exposure did not exceed the threshold available in the literature. Formaldehyde concentrations were high, in the kitchen, where the average concentrations exceeded the threshold. However, the formaldehyde cumulative exposure of the occupants did not exceed the threshold. TVOC concentrations were found to reach the threshold. With these measurements performed with high spatial and temporal discretization, we showed that such detailed data allow for a better-quality health impacts assessment and for a better understanding of the transport of pollutants between rooms.
- 11 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11789
Open AccessIndoor Air Quality Campaign in an Occupied Low-Energy House with a High Level of Spatial and Temporal Discretization
Background and gaps. The topic of indoor air quality (IAQ) in low-energy buildings has received increasing interest over the past few years. Often based on two measurement points and on passive measurements over one week, IAQ studies are struggling to allow the calculation of pollutants exposure. Objectives. We would like to improve the evaluation of the health impacts, through measurements able to estimate the exposure of the occupants. Methodology. This article presents detailed IAQ measurements taken in an energy-efficient occupied house in France. Two campaigns were conducted in winter and spring. Total volatile organic compounds (TVOC), formaldehyde, the particle numbers and PM2.5, carbon dioxide (CO2), relative humidity (RH), temperature (T), ventilation airflows, and weather conditions were dynamically measured in several points. Laboratory and low-cost devices were used, and an inter-comparison was carried out for them. A survey was conducted to record all the daily activities of the inhabitants. IAQ performance indicators based on the different pollutants were calculated. Results. PM2.5 cumulative exposure did not exceed the threshold available in the literature. Formaldehyde concentrations were high, in the kitchen, where the average concentrations exceeded the threshold. However, the formaldehyde cumulative exposure of the occupants did not exceed the threshold. TVOC concentrations were found to reach the threshold. With these measurements performed with high spatial and temporal discretization, we showed that such detailed data allow for a better-quality health impacts assessment and for a better understanding of the transport of pollutants between rooms.
- Open Access
- 16 August 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (16) , 9199
Co-Digestion of Extended Aeration Sewage Sludge with Whey, Grease and Septage: Experimental and Modeling Determination
The potential of co-digestion mixing thickened secondary sludge (TS) from extended aeration wastewater treatment plant and locally available substrates (whey, grease and septage) has been studied in this work, using three steps. The first step was a batch test to determine the biological methane potential (BMP) of different mixtures of the three co-substrates with TS. The second step was carried out with lab-scale reactors (20 L), simulating anaerobic continuous stirred tank reactors, fed by three mixtures of co-substrates that were determined according to the previous step results. Modeling was applied in the third step, using ADM1 as a mechanistic model to help understand the co-digestion process. According to the BMP step, septage used as a co-substrate has a negative effect on performance, and the addition of 10–30% grease or whey would lead to a gain of around 60–70% in the production of methane. The results from the reactor tests did not validate the positive effects observed with the BMP assay but confirmed good biodegradation efficiency (> 85%). The main purpose of co-digestion in this scenario is to recover energy from waste and effluents that would require even more energy for their treatment. The protein and lipid percentages of particulate biodegradable COD are important variables for digester stability and methane production, as predicted by modeling. The results of simulations with the ADM1 model, adapted to co-digestion, confirmed that this model is a powerful tool to optimize the process of biogas production.
- 16 August 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (16) , 9199
Open AccessCo-Digestion of Extended Aeration Sewage Sludge with Whey, Grease and Septage: Experimental and Modeling Determination
The potential of co-digestion mixing thickened secondary sludge (TS) from extended aeration wastewater treatment plant and locally available substrates (whey, grease and septage) has been studied in this work, using three steps. The first step was a batch test to determine the biological methane potential (BMP) of different mixtures of the three co-substrates with TS. The second step was carried out with lab-scale reactors (20 L), simulating anaerobic continuous stirred tank reactors, fed by three mixtures of co-substrates that were determined according to the previous step results. Modeling was applied in the third step, using ADM1 as a mechanistic model to help understand the co-digestion process. According to the BMP step, septage used as a co-substrate has a negative effect on performance, and the addition of 10–30% grease or whey would lead to a gain of around 60–70% in the production of methane. The results from the reactor tests did not validate the positive effects observed with the BMP assay but confirmed good biodegradation efficiency (> 85%). The main purpose of co-digestion in this scenario is to recover energy from waste and effluents that would require even more energy for their treatment. The protein and lipid percentages of particulate biodegradable COD are important variables for digester stability and methane production, as predicted by modeling. The results of simulations with the ADM1 model, adapted to co-digestion, confirmed that this model is a powerful tool to optimize the process of biogas production.
- 6 March 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (6) , 4954-4965
Suitability of Thermal Swing Adsorption for the Treatment of Siloxanes and Toluene in Biogas: An Experimental Study
- 6 March 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (6) , 4954-4965
Suitability of Thermal Swing Adsorption for the Treatment of Siloxanes and Toluene in Biogas: An Experimental Study
- Open Access
- 1 November 2016
- Published by INIST-CNRS in Pollution atmosphérique
- No. N°231 - 23
Développement d’un procédé pour l’épuration de l’air intérieur par couplage de la décharge couronne et de l’adsorption
La dégradation d’un Composé Organique Volatil (COV), le toluène, pour des concentrations comprises entre 8 et 500 pbbv, est étudiée par couplage de la décharge couronne et de l’adsorption pour le traitement de l’air intérieur. Cette étude a permis de mettre en évidence des efficacités de dégradation dans la décharge supérieures à 90 % en polarité négative, pour des concentrations en toluène de 9 ppbv. L’utilisation d’un adsorbant en sortie du plasma, le charbon actif, permet de réduire de manière significative, d’un facteur 4, les concentrations résiduelles en toluène issues du plasma. Concernant l’ozone, composé inorganique issu du plasma, les cinétiques de dégradation sur le charbon sont lentes, mais les capacités d’adsorption importantes de ce matériau vis-à-vis de ce composé sont prometteuses. This work proposes the use of non-thermal plasma for the degradation of Volatile Organic Compounds (VOC) in indoor air. The toluene, a representative indoor air pollutant, was used as target pollutant at concentration range from 8 to 500 ppbv. Removal efficiencies higher than 90% were reached using a negative corona discharge. The adsorption allows removing significant amounts of the toluene which was not removed passing through the plasma: the amount of toluene with the combined process is reduced by a factor 4. Ozone, an inorganic compound produced by the plasma, could also be removed by the activated carbon. In spite of the low kinetic rates of adsorption, because of the high adsorption capacities of the activated carbon, the implementation of adsorption in combination with non-thermal plasma appears as a highly promising process.
- 1 November 2016
- Published by INIST-CNRS in Pollution atmosphérique
- No. N°231 - 23
Open AccessDéveloppement d’un procédé pour l’épuration de l’air intérieur par couplage de la décharge couronne et de l’adsorption
La dégradation d’un Composé Organique Volatil (COV), le toluène, pour des concentrations comprises entre 8 et 500 pbbv, est étudiée par couplage de la décharge couronne et de l’adsorption pour le traitement de l’air intérieur. Cette étude a permis de mettre en évidence des efficacités de dégradation dans la décharge supérieures à 90 % en polarité négative, pour des concentrations en toluène de 9 ppbv. L’utilisation d’un adsorbant en sortie du plasma, le charbon actif, permet de réduire de manière significative, d’un facteur 4, les concentrations résiduelles en toluène issues du plasma. Concernant l’ozone, composé inorganique issu du plasma, les cinétiques de dégradation sur le charbon sont lentes, mais les capacités d’adsorption importantes de ce matériau vis-à-vis de ce composé sont prometteuses. This work proposes the use of non-thermal plasma for the degradation of Volatile Organic Compounds (VOC) in indoor air. The toluene, a representative indoor air pollutant, was used as target pollutant at concentration range from 8 to 500 ppbv. Removal efficiencies higher than 90% were reached using a negative corona discharge. The adsorption allows removing significant amounts of the toluene which was not removed passing through the plasma: the amount of toluene with the combined process is reduced by a factor 4. Ozone, an inorganic compound produced by the plasma, could also be removed by the activated carbon. In spite of the low kinetic rates of adsorption, because of the high adsorption capacities of the activated carbon, the implementation of adsorption in combination with non-thermal plasma appears as a highly promising process.