Michel Ondarts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Michel Ondarts has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Evelyne Gonze
7 shared publications- Gaëlle Guyot
BPE Research Team, Cerema
5 shared publications - Benjamin Golly
University Grenoble Alpes, CNRS, IRD, INP-G, IGE (UMR 5001), 38000 Grenoble, France
4 shared publications Jonathan Outin
LOCIE Laboratory, UMR 5271, CNRS
4 shared publications- Jonathan Outin
Géosciences Montpellier Université de Montpellier Université des Antilles CNRS UMR 5243 Montpellier Cedex France
4 shared publications - Nolwenn Le Pierrès
Université Savoie Mont Blanc
4 shared publications
Latest Publications
- Open Access
- 20 June 2026
- Published by Elsevier in Building and Environment
- Vol. 302
Development of environmental chamber NUAGE and its digital twin for holistic indoor air quality studies in French dwellings
- 20 June 2026
- Published by Elsevier in Building and Environment
- Vol. 302
Open AccessDevelopment of environmental chamber NUAGE and its digital twin for holistic indoor air quality studies in French dwellings
- Open Access
- 31 August 2025
- Published by Elsevier in Separation and Purification Technology
- Vol. 379
A semi-analytical model for assessing nanoparticle collection efficiencies in the partial charging regime
- 31 August 2025
- Published by Elsevier in Separation and Purification Technology
- Vol. 379
Open AccessA semi-analytical model for assessing nanoparticle collection efficiencies in the partial charging regime
- 9 October 2024
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 7 (20) , 9242-9254
Improving Materials for Compact Thermal Energy Storage: Two Case Studies on Tailor-Made Polyalcohol Mixtures (PCMs) and Composites of Chlorides Confined in Gamma-Alumina or Silica-PEG (TCMs)
- 9 October 2024
- Published by American Chemical Society (ACS) in ACS Applied Energy Materials
- Vol. 7 (20) , 9242-9254
Improving Materials for Compact Thermal Energy Storage: Two Case Studies on Tailor-Made Polyalcohol Mixtures (PCMs) and Composites of Chlorides Confined in Gamma-Alumina or Silica-PEG (TCMs)
- Open Access
- 20 June 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 231
Simulation of a zeolite thermochemical heat storage reactor: Impact assessment of isotherm model selection
- 20 June 2024
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 231
Open AccessSimulation of a zeolite thermochemical heat storage reactor: Impact assessment of isotherm model selection
- 1 January 2024
- Published by ISTE Group in Entropie : Thermodynamique – Énergie – Environnement – Économie
- Vol. 5 (5)
Stockage de chaleur thermochimique : expérimentation de différents matériaux composites innovants
Le stockage de chaleur par voie thermochimique est une solution d'avenir, car il permet un stockage sur des périodes aussi longues que désiré avec une densité énergétique élevée. Des sorbants (...)
- 1 January 2024
- Published by ISTE Group in Entropie : Thermodynamique – Énergie – Environnement – Économie
- Vol. 5 (5)
Stockage de chaleur thermochimique : expérimentation de différents matériaux composites innovants
Le stockage de chaleur par voie thermochimique est une solution d'avenir, car il permet un stockage sur des périodes aussi longues que désiré avec une densité énergétique élevée. Des sorbants (...)
- 9 December 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 65
Analysis and comparison of thermal comfort indicators based on a long-term campaign in low energy residences
- 9 December 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 65
Analysis and comparison of thermal comfort indicators based on a long-term campaign in low energy residences
- Open Access
- 11 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11789
Indoor Air Quality Campaign in an Occupied Low-Energy House with a High Level of Spatial and Temporal Discretization
Background and gaps. The topic of indoor air quality (IAQ) in low-energy buildings has received increasing interest over the past few years. Often based on two measurement points and on passive measurements over one week, IAQ studies are struggling to allow the calculation of pollutants exposure. Objectives. We would like to improve the evaluation of the health impacts, through measurements able to estimate the exposure of the occupants. Methodology. This article presents detailed IAQ measurements taken in an energy-efficient occupied house in France. Two campaigns were conducted in winter and spring. Total volatile organic compounds (TVOC), formaldehyde, the particle numbers and PM2.5, carbon dioxide (CO2), relative humidity (RH), temperature (T), ventilation airflows, and weather conditions were dynamically measured in several points. Laboratory and low-cost devices were used, and an inter-comparison was carried out for them. A survey was conducted to record all the daily activities of the inhabitants. IAQ performance indicators based on the different pollutants were calculated. Results. PM2.5 cumulative exposure did not exceed the threshold available in the literature. Formaldehyde concentrations were high, in the kitchen, where the average concentrations exceeded the threshold. However, the formaldehyde cumulative exposure of the occupants did not exceed the threshold. TVOC concentrations were found to reach the threshold. With these measurements performed with high spatial and temporal discretization, we showed that such detailed data allow for a better-quality health impacts assessment and for a better understanding of the transport of pollutants between rooms.
- 11 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11789
Open AccessIndoor Air Quality Campaign in an Occupied Low-Energy House with a High Level of Spatial and Temporal Discretization
Background and gaps. The topic of indoor air quality (IAQ) in low-energy buildings has received increasing interest over the past few years. Often based on two measurement points and on passive measurements over one week, IAQ studies are struggling to allow the calculation of pollutants exposure. Objectives. We would like to improve the evaluation of the health impacts, through measurements able to estimate the exposure of the occupants. Methodology. This article presents detailed IAQ measurements taken in an energy-efficient occupied house in France. Two campaigns were conducted in winter and spring. Total volatile organic compounds (TVOC), formaldehyde, the particle numbers and PM2.5, carbon dioxide (CO2), relative humidity (RH), temperature (T), ventilation airflows, and weather conditions were dynamically measured in several points. Laboratory and low-cost devices were used, and an inter-comparison was carried out for them. A survey was conducted to record all the daily activities of the inhabitants. IAQ performance indicators based on the different pollutants were calculated. Results. PM2.5 cumulative exposure did not exceed the threshold available in the literature. Formaldehyde concentrations were high, in the kitchen, where the average concentrations exceeded the threshold. However, the formaldehyde cumulative exposure of the occupants did not exceed the threshold. TVOC concentrations were found to reach the threshold. With these measurements performed with high spatial and temporal discretization, we showed that such detailed data allow for a better-quality health impacts assessment and for a better understanding of the transport of pollutants between rooms.
- 1 December 2021
- Published by Elsevier in Journal of Building Engineering
- Vol. 44
Relevance of CO2-based IAQ indicators: Feedback from long-term monitoring of three nearly zero-energy houses
- 1 December 2021
- Published by Elsevier in Journal of Building Engineering
- Vol. 44
Relevance of CO2-based IAQ indicators: Feedback from long-term monitoring of three nearly zero-energy houses