Inyong Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Inyong Kwon has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Dongsuk Jeon
Seoul National University
4 shared publications - Minuk Seung
Korea Atomic Energy Research Institute (KAERI), Daejeon, South Korea
4 shared publications - Changyeop Lee
School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, Korea
2 shared publications - Jinseok Oh
Department of Nuclear Power and Radiation Safety, University of Science and Technology (UST), Daejeon, South Korea
2 shared publications Min Sun Lee
Daegu Gyeongbuk Institute of Science and Technology (DGIST)
2 shared publications- Seop Hur
Korea Atomic Energy Research Institute, Daejeon, South Korea
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 3918-3926
Analysis of Total Ionizing Dose Effect on a Linear RF Power Amplifier
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (10) , 3918-3926
Analysis of Total Ionizing Dose Effect on a Linear RF Power Amplifier
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
A Dual Active Quenching Circuit With Temperature Compensation Technique for Breakdown Voltage Shift of Single-Photon Avalanche Diodes
A front-end circuit of single-photon avalanche diode (SPAD) which achieves dual active quenching and compensates the breakdown voltage shift due to temperature is presented in this paper. A well-defined quenching circuit reduces noise signals such as dark count rate and afterpulsing probability and enhances resolutions when applied to imaging applications. Meanwhile, it requires a compact design to optimize light absorption. In addition, the inherent breakdown-voltage of SPAD is vulnerable to its temperature variation, leading to a significant performance degradation. The proposed circuit achieves dual active quenching by a common-source amplifier, controlling anode and cathode at the same time. Moreover, it mitigates the breakdown-voltage shift by exploiting the characteristic that MOSFET current and resistance decrease as temperature increases, maintaining a constant excess bias voltage for SPAD. Simulation results demonstrate that the quenching time has decreased by 45 % compared to conventional approaches. Measurement results indicate a twofold reduction in breakdown-voltage shift with temperature variation, along with a 30 % reduction in dark count rate and a 40 % reduction in afterpulsing probability. The designed circuits were fabricated using 0.18 μm complementary metal-oxide-semiconductor (CMOS) technology.
- 20 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
A Dual Active Quenching Circuit With Temperature Compensation Technique for Breakdown Voltage Shift of Single-Photon Avalanche Diodes
A front-end circuit of single-photon avalanche diode (SPAD) which achieves dual active quenching and compensates the breakdown voltage shift due to temperature is presented in this paper. A well-defined quenching circuit reduces noise signals such as dark count rate and afterpulsing probability and enhances resolutions when applied to imaging applications. Meanwhile, it requires a compact design to optimize light absorption. In addition, the inherent breakdown-voltage of SPAD is vulnerable to its temperature variation, leading to a significant performance degradation. The proposed circuit achieves dual active quenching by a common-source amplifier, controlling anode and cathode at the same time. Moreover, it mitigates the breakdown-voltage shift by exploiting the characteristic that MOSFET current and resistance decrease as temperature increases, maintaining a constant excess bias voltage for SPAD. Simulation results demonstrate that the quenching time has decreased by 45 % compared to conventional approaches. Measurement results indicate a twofold reduction in breakdown-voltage shift with temperature variation, along with a 30 % reduction in dark count rate and a 40 % reduction in afterpulsing probability. The designed circuits were fabricated using 0.18 μm complementary metal-oxide-semiconductor (CMOS) technology.
- 24 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
A Light Detector Capacitance Compensation Technique Achieving Boosted Active Quenching for Single-Photon Avalanche Diodes
The detector capacitance compensation (DCC) technique which enables double active quenching of single-photon avalanche diode (SP AD) is presented in this paper. A well-defmed active quenching circuit offers advantages such as a higher maximum photon-counting rate and lower afterpulsing probability. Also, the adjustable hold-off time caters to various demands in SP AD applications. The fast rise time, contributing to higher jitter performance, enables better resolutions when applied to medical imaging applications, such as positron emission tomography (PET). Meanwhile, the compact design of the active quenching circuit is essential for seamless integration with SP ADs. The proposed light active quenching circuit incorporates the conventional active quenching scheme with a light unity-gain amplifier for detector capacitance compensation. The employment of the DCC technique in quenching time simulation demonstrates almost three times better results compared to the conventional approach, with a mere 23 % increase in area and lower power consumption. The DCC technique is also effectively applied to a passive quenching circuit. Hold-off time is controlled by only using a current-starved inverter. The simulation results and measured data are shown in this paper. Designed circuits are fabricated using 0.18 μm complementary metal-oxide-semiconductor (CMOS) technology.
- 24 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
A Light Detector Capacitance Compensation Technique Achieving Boosted Active Quenching for Single-Photon Avalanche Diodes
The detector capacitance compensation (DCC) technique which enables double active quenching of single-photon avalanche diode (SP AD) is presented in this paper. A well-defmed active quenching circuit offers advantages such as a higher maximum photon-counting rate and lower afterpulsing probability. Also, the adjustable hold-off time caters to various demands in SP AD applications. The fast rise time, contributing to higher jitter performance, enables better resolutions when applied to medical imaging applications, such as positron emission tomography (PET). Meanwhile, the compact design of the active quenching circuit is essential for seamless integration with SP ADs. The proposed light active quenching circuit incorporates the conventional active quenching scheme with a light unity-gain amplifier for detector capacitance compensation. The employment of the DCC technique in quenching time simulation demonstrates almost three times better results compared to the conventional approach, with a mere 23 % increase in area and lower power consumption. The DCC technique is also effectively applied to a passive quenching circuit. Hold-off time is controlled by only using a current-starved inverter. The simulation results and measured data are shown in this paper. Designed circuits are fabricated using 0.18 μm complementary metal-oxide-semiconductor (CMOS) technology.
- Open Access
- 1 April 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (4)
Observation of fast Alfvén wave in KAERI plasma beam irradiation facility using an applied-field MPD thruster
Electromagnetic fluctuations between 300 and 500 kHz were observed in both ion saturation current and magnetic field measurements in the KAERI plasma beam irradiation facility where the applied-field magnetoplasmadynamic (MPD) thruster is used as a plasma source. In this study, the plasmas were ignited with deuterium gas and the plasma current (input power) was varied from 55 A (2 kW) to 155 A (6 kW). The electron temperature and density measured downstream of the MPD thruster plasma were ∼5 eV and (2–4) × 1012 cm−3, respectively. To identify the fluctuations, the dispersion relation and the phase velocity were experimentally obtained using the Beall method and were compared to the theoretical values under warm plasma conditions. It was revealed that the observed fluctuations were fast Alfvén waves with a circularly polarized magnetic field. In addition to the fast Alfvén waves, we also observed electrostatic fluctuations at a higher frequency that was similar to the lower-hybrid frequency.
- 1 April 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (4)
Open AccessObservation of fast Alfvén wave in KAERI plasma beam irradiation facility using an applied-field MPD thruster
Electromagnetic fluctuations between 300 and 500 kHz were observed in both ion saturation current and magnetic field measurements in the KAERI plasma beam irradiation facility where the applied-field magnetoplasmadynamic (MPD) thruster is used as a plasma source. In this study, the plasmas were ignited with deuterium gas and the plasma current (input power) was varied from 55 A (2 kW) to 155 A (6 kW). The electron temperature and density measured downstream of the MPD thruster plasma were ∼5 eV and (2–4) × 1012 cm−3, respectively. To identify the fluctuations, the dispersion relation and the phase velocity were experimentally obtained using the Beall method and were compared to the theoretical values under warm plasma conditions. It was revealed that the observed fluctuations were fast Alfvén waves with a circularly polarized magnetic field. In addition to the fast Alfvén waves, we also observed electrostatic fluctuations at a higher frequency that was similar to the lower-hybrid frequency.
- Open Access
- 8 March 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (8) , 2916-2922
Radiation tolerant capacitor-SRAM without area overhead
- 8 March 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (8) , 2916-2922
Open AccessRadiation tolerant capacitor-SRAM without area overhead
- Open Access
- 5 March 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (8) , 3076-3083
Characterization of small single photon avalanche diode fabricated using standard 180 nm CMOS process for digital SiPM
- 5 March 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (8) , 3076-3083
Open AccessCharacterization of small single photon avalanche diode fabricated using standard 180 nm CMOS process for digital SiPM
- 11 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Gain-Bandwidth Product Compensation Technique by 16-Unit Tail Current Control for a Radiation Tolerant Preamplifier With 0.9% Amplitude Drop up to 5 Mrad
This article presents a self-compensated charge-sensitive amplifier (CSA) for total ionizing dose (TID) effects, which directly compensates for the nonlinearity characteristic of the preamplifier, caused by radiation. The proposed circuit is operated by monitoring on amplitude degradation of a replicated CSA from a constant pulse and compensating the main CSA from the gain bandwidth product (GBWP) equation with current steering DAC control. The proposed technique was evaluated under a gamma-ray irradiation environment using Cobalt-60 with an activity of 490 kCi at Korea Atomic Energy Research Institute (KAERI) in Korea and provided a linear output with an amplitude degradation of 0.9%. In contrast, a noncompensated CSA showed a 70% decrease in amplitude after irradiation exposed to up to 5 Mrad (SiO2). The proposed technique was fabricated in a 180-nm standard BiCMOS technology. This direct compensation approach offers a promising solution to reduce radiation effects on the preamplifier for applications of radiation-hardened electronics.
- 11 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Gain-Bandwidth Product Compensation Technique by 16-Unit Tail Current Control for a Radiation Tolerant Preamplifier With 0.9% Amplitude Drop up to 5 Mrad
This article presents a self-compensated charge-sensitive amplifier (CSA) for total ionizing dose (TID) effects, which directly compensates for the nonlinearity characteristic of the preamplifier, caused by radiation. The proposed circuit is operated by monitoring on amplitude degradation of a replicated CSA from a constant pulse and compensating the main CSA from the gain bandwidth product (GBWP) equation with current steering DAC control. The proposed technique was evaluated under a gamma-ray irradiation environment using Cobalt-60 with an activity of 490 kCi at Korea Atomic Energy Research Institute (KAERI) in Korea and provided a linear output with an amplitude degradation of 0.9%. In contrast, a noncompensated CSA showed a 70% decrease in amplitude after irradiation exposed to up to 5 Mrad (SiO2). The proposed technique was fabricated in a 180-nm standard BiCMOS technology. This direct compensation approach offers a promising solution to reduce radiation effects on the preamplifier for applications of radiation-hardened electronics.
- Open Access
- 4 November 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (2) , 568-574
Simulation-based analysis of total ionizing dose effects on low noise amplifier for wireless communications
- 4 November 2023
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (2) , 568-574
Open AccessSimulation-based analysis of total ionizing dose effects on low noise amplifier for wireless communications
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
In-Core Neutron Detection System Using a Dual-Mode Self-Reset Preamplifier With the Micro-Pocket Fission Detector
This article presents the development of an in-core neutron detector readout system utilizing a charge-sensitive amplifier (CSA) with a self-reset technique, alongside data loggers, to measure the output of the CSA. Micro-pocket fission detectors (MPFDs) were developed as in-vessel neutron detectors having many advantages in terms of portability size, reproducibility of charge deposition, usability in high neutron flux, and capability of gamma-ray discrimination. The proposed readout system for MPFDs can be operated in a dual mode which consists of integration and single event modes. The integration mode can count the number of saturated preamplifier outputs in a high-radiation environment. On the other hand, the single event mode can directly measure the analog data induced by detectors. A novel approach to dead time compensation is also introduced using an active dead time control (ADTC) method. This article shows the reactor transient test results conducted at the Transient REActor Test (TREAT) reactor. The neutron flux of 7 × 10 15 n/cm 2 · s with the full-width half maximum (FWHM) of 126 ms at the reactor power of 2.1 GWth was measured. According to the reactor power of 5.1 GWth, the neutron flux, and FWHM were obtained as 1.24 × 10 16 n/cm 2 · s and 136 ms, respectively.
- 25 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
In-Core Neutron Detection System Using a Dual-Mode Self-Reset Preamplifier With the Micro-Pocket Fission Detector
This article presents the development of an in-core neutron detector readout system utilizing a charge-sensitive amplifier (CSA) with a self-reset technique, alongside data loggers, to measure the output of the CSA. Micro-pocket fission detectors (MPFDs) were developed as in-vessel neutron detectors having many advantages in terms of portability size, reproducibility of charge deposition, usability in high neutron flux, and capability of gamma-ray discrimination. The proposed readout system for MPFDs can be operated in a dual mode which consists of integration and single event modes. The integration mode can count the number of saturated preamplifier outputs in a high-radiation environment. On the other hand, the single event mode can directly measure the analog data induced by detectors. A novel approach to dead time compensation is also introduced using an active dead time control (ADTC) method. This article shows the reactor transient test results conducted at the Transient REActor Test (TREAT) reactor. The neutron flux of 7 × 10 15 n/cm 2 · s with the full-width half maximum (FWHM) of 126 ms at the reactor power of 2.1 GWth was measured. According to the reactor power of 5.1 GWth, the neutron flux, and FWHM were obtained as 1.24 × 10 16 n/cm 2 · s and 136 ms, respectively.